Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Small gas turbine combustor study: Fuel injector performance in a transpiration-cooled liner

The effect of fuel injection technique on the performance of an advanced reverse flow combustor liner constructed of Lamilloy (a multilaminate transpiration type material) was determined. Performance and emission levels are documented over a range of simulated flight conditions using simplex pressure atomizing, spill return, and splash cone airblast injectors. A parametric evaluation of the effect of increased combustor loading with each of the fuel injector types is obtained.

Riddlebaugh, S. M.↗

Small gas turbine combustor study - Fuel injector performance in a transpiration-cooled liner

The effect of fuel injection technique on the performance of an advanced reverse flow combustor liner constructed of Lamilloy (a multilaminate transpiration type material) was determined. Performance and emission levels are documented over a range of simulated flight conditions using simplex pressure atomizing, spill return, and splash cone airblast injectors. A parametric evaluation of the effect of increased combustor loading with each of the fuel injector types is obtained.

Riddlebaugh, S. M.↗

Stirling-Cycle Cooling For Tunable Diode Laser

Miniature Stirling-cycle cooler effective in continously cooling PbSnTe tunable diode laser to stable operating temperature near 80 K. Simplifies laboratory diode-laser spectroscopy and instruments for use aboard aircraft and balloons.

Durso, Santo S.↗

Optimizing a Coupled Solution for the Orion MPCV Using DPLR and NEQAIR

The goal of this project is to study the convective and radiative heat flux predictions using computational fluid dynamics (CFD) on a smooth body representation of the NASA Orion Multi-Purpose Crew Vehicle (MPCV). The Orion MPCV is designed for long duration missions in space and will play a crucial role in transporting astronauts in the upcoming Artemis missions. With Orion's aim for cost-effective reusability comes a need to study its Thermal Protection System (TPS), which allows for safe entry into the atmospheres of the Earth, Moon, and Mars. In order to study the effects of the TPS on test flights and better understand the aerothermal environment, CFD is a necessary tool used to create simulations of entry vehicles and calculate the heat load and heat flux. However, solutions are often performed using an uncoupled approach between the flow and the radiation solver. This leads to an overestimation of the overall heating effects because they do not consider radiative cooling. Furthermore, the effects of radiation on the aft-body is an area of research with significant uncertainty. Through the use of codes developed at NASA Ames, DPLR and NEQAIR, a coupled solution can be attained for the Orion capsule which will more accurately solve for the effects of radiation in both the fore and aft-body regions. This yields more accurate design margins for the TPS, which produces a better estimate of the thickness required. By developing an accurate coupled solution of the TPS on the Orion MPCV, planners will have greater flexibility in carrying out future missions to the Moon and beyond.

Design↗

High-Altitude Flight Cooling Investigation of a Radial Air-Cooled Engine

An investigation of the cooling of an 18-cylinder, twin-row, radial, air-cooled engine in a high-performance pursuit airplane has been conducted for variable engine and flight conditions at altitudes ranging from 5000 to 35,000 feet in order to provide a basis for predicting high-altitude cooling performance from sea-level or low altitude experimental results. The engine cooling data obtained were analyzed by the usual NACA cooling-correlation method wherein cylinder-head and cylinder-barrel temperatures are related to the pertinent engine and cooling-air variables. A theoretical analysis was made of the effect on engine cooling of the change of density of the cooling air across the engine (the compressibility effect), which becomes of increasing importance as altitude is increased. Good agreement was obtained between the results of the theoretical analysis and the experimental data.

Manganiello, Eugene J↗

Cooling of pulsars.

The effects of the magnetic field and superfluidity on the cooling of neutron stars during the stage when they can be observed as pulsars are considered. A neutron-star model with a stellar mass of 1.07 solar mass, a radius of 12.33 km, and a central energy density of 7.39 x 10 to the 14th power gauss/cu cm was chosen. It appears that during the earlier periods while the star cools by neutrino emission, surface temperatures are somewhat higher at a given age in the presence of stronger magnetic fields. An interesting result is that most pulsars may be very cold.

Tsuruta, S.↗

Hot streaks and phantom cooling in a turbine rotor passage. II - Combined effects and analytical modelling

Experimental documentation and analytical correlations demonstrating the effects of hot streak accumulation and phantom cooling on turbine rotor airfoil surface temperature are presented. Results are shown which quantify the impact of a nonuniform temperature profile at the entrance of a turbine due to combustor-generated hot and cold streaks, and cooling air discharged from the trailing edge of the upstream stator. Experimental results are shown for a range of controlling variables to identify where streak accumulation and phantom cooling were most likely to be strongest. These variables include streak-to-free stream density ratio, streak injection location, and coolant-to-free stream density and velocity ratios. Experimental results are shown for the combined effects of hot streak and stator coolant on the adiabatic recovery temperature of the rotor.

Roback, Richard J.↗

CHARACTERIZING THE COOL KEPLER OBJECTS OF INTERESTS. NEW EFFECTIVE TEMPERATURES, METALLICITIES, MASSES, AND RADII OF LOW-MASS KEPLER PLANET-CANDIDATE HOST STARS

We report stellar parameters for late-K and M-type planet-candidate host stars announced by the Kepler Mission. We obtained medium-resolution, K-band spectra of 84 cool (T{sub eff} {approx}< 4400 K) Kepler Objects of Interest (KOIs) from Borucki et al. We identified one object as a giant (KOI 977); for the remaining dwarfs, we measured effective temperatures (T{sub eff}) and metallicities [M/H] using the K-band spectral indices of Rojas-Ayala et al. We determine the masses (M{sub *}) and radii (R{sub *}) of the cool KOIs by interpolation onto the Dartmouth evolutionary isochrones. The resultant stellar radii are significantly less than the values reported in the Kepler Input Catalog and, by construction, correlate better with T{sub eff}. Applying the published KOI transit parameters to our stellar radius measurements, we report new physical radii for the planet candidates. Recalculating the equilibrium temperatures of the planet-candidates assuming Earth's albedo and re-radiation fraction, we find that three of the planet-candidates are terrestrial sized with orbital semimajor axes that lie within the habitable zones of their host stars (KOI 463.01, KOI 812.03, and KOI 854.01). The stellar parameters presented in this Letter serve as a resource for prioritization of future follow-up efforts to validate and characterize the cool KOI planet candidates.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of Effects of SiO{sub 2} Content and Cooling Rate on Crystallization in Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} System Using In Situ Confocal Laser Scanning Microscopy

The crystallization behaviors of the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system in a non-equilibrium state with various chemical compositions and cooling rates were investigated by confocal laser scanning. Equilibrium samples were prepared in melt states and cooled at a rate of 1 K/min to produce samples in quasi-equilibrium states. The effect of SiO{sub 2} on the phase constitution was investigated using Image Analyzer, and the changes of the phase ratios were analyzed using activity values of Fe{sub 2}O{sub 3} calculated using FactSage 7.1. The Continuous cooling transformation diagram of the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system was obtained for various cooling rates. The temperatures at which the primary phase formed for various SiO{sub 2} contents and cooling rates differed from the equilibrium temperatures, and the phase-formation temperature ranges varied with the cooling rate. In addition, the reduction degree of each sample was measured to determine the effect of SiO{sub 2} content and cooling rate on the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system. The reduction degree in the FeO{sub 3}-CaO-SiO{sub 2} system is dominantly influenced by the SiO{sub 2} bond-phase morphology (CF, C{sub 2}S, C{sub 3}S, or glass) rather than the cooling rate.

36 MATERIALS SCIENCE↗

Adiabatic Cooling of Antiprotons

Adiabatic cooling is shown to be a simple and effective method to cool many charged particles in a trap to very low temperatures. Up to 3x10{sup 6} p are cooled to 3.5 K--10{sup 3} times more cold p and a 3 times lower p temperature than previously reported. A second cooling method cools p plasmas via the synchrotron radiation of embedded e{sup -} (with many fewer e{sup -} than p) in preparation for adiabatic cooling. No p are lost during either process--a significant advantage for rare particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Buoyant AGN Bubbles in the Quasi-isothermal Potential of NGC 1399

The Fornax Cluster is a low-mass cool-core galaxy cluster. We present a deep Chandra study of NGC 1399, the central dominant elliptical galaxy of Fornax. The cluster center harbors two symmetric X-ray cavities coincident with a pair of radio lobes fed by two collimated jets along a north–south axis. A temperature map reveals that the active galactic nucleus (AGN) outburst has created a channel filled with cooler gas out to a radius of 10 kpc. The cavities are surrounded by cool bright rims and filaments that may have been lifted from smaller radii by the buoyant bubbles. X-ray imaging suggests a potential ghost bubble of ≳5 kpc diameter to the northwest. We find that the amount of gas lifted by AGN bubbles is comparable to that which would otherwise cool, demonstrating that AGN-driven outflow is effective in offsetting cooling in low-mass clusters. The cluster cooling timescale is >30 times longer than the dynamical timescale, which is consistent with the lack of cold molecular gas at the cluster center. The X-ray hydrostatic mass is consistent within 10%, with the total mass derived from the optical data. The observed entropy profile rises linearly, following a steeper slope than that observed at the centers of massive clusters; gas shed by stars in NGC 1399 may be incorporated in the hot phase. However, it is far-fetched for supernova-driven outflow to produce and maintain the thermal distribution in NGC 1399, and it is in tension with the metal content in the hot gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of film injection on performance of a cooled turbine

Some of the most dramatic increases in the performance of turbojet and turbofan aircraft engines have been obtained as a result of increased thermodynamic cycle temperatures made possible by the use of film cooling techniques. The realization of the potential performance gains, however, is only possible if the quantity of cooling air and the aerodynamic mixing losses resulting from the injection of coolant in the form of film on the flowpath surfaces are minimized. Such a minimization requires a more complete understanding of the relationship between cooling and aerodynamics. A review is conducted of tests which have been conducted to determine the effects of coolant injection on turbine performance. The results obtained in the tests are compared with an analytical technique developed for predicting coolant injection effects. Particular attention is given to the effects of turbine cooling on overall cycle thermodynamic efficiency, taking into account incremental changes in turbine thermodynamic efficiency for various incremental changes in coolant flow rate.

Mcdonel, J. D.↗

Assessing the Impact of Effective Thermal Conductivity on Gas-cooled Reactor Transients in RELAP5-3D

In block-type high-temperature gas-cooled reactors (HTGRs), coolant holes in blocks lead to a reduction in heat transfer through conduction. In systems codes like RELAP5-3D, we must account for this degradation by using an effective thermal conductivity (ETC). This presentation discusses a few ETC relationships and demonstrates the impact of ETC for the modular High-Temperature Gas-Cooled Reactor 350 MW -- a computational benchmark for HTGR modeling -- and for the High Temperature Test Facility (HTTF) -- an HTGR thermal hydraulics test facility. We demonstrate that the use of ETC leads to temperatures that are higher than the bulk thermal conductivity of the block material would yield, but these differences have no meaningful impact on the transient performance of the reactors. The ETC also reduces the cooldown rate, leading to more time at elevated temperatures. Overall, while accounting for ETC is important in capturing the physics of the reactor, it is not expected to have a meaningful impact on transient performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The effects of leading edge and downstream film cooling on turbine vane heat transfer

The progress under contract NAS3-24619 toward the goal of establishing a relevant data base for use in improving the predictive design capabilities for external heat transfer to turbine vanes, including the effect of downstream film cooling with and without leading edge showerhead film cooling. Experimental measurements were made in a two-dimensional cascade previously used to obtain vane surface heat transfer distributions on nonfilm cooled airfoils under contract NAS3-22761 and leading edge showerhead film cooled airfoils under contract NAS3-23695. The principal independent parameters (Mach number, Reynolds number, turbulence, wall-to-gas temperature ratio, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio) were maintained over ranges consistent with actual engine conditions and the test matrix was structured to provide an assessment of the independent influence of parameters of interest, namely, exit Mach number, exit Reynolds number, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio. Data provide a data base for downstream film cooled turbine vanes and extends the data bases generated in the two previous studies. The vane external heat transfer obtained indicate that considerable cooling benefits can be achieved by utilizing downstream film cooling. The data obtained and presented illustrate the interaction of the variables and should provide the airfoil designer and computational analyst the information required to improve heat transfer design capabilities for film cooled turbine airfoils.

Hylton, L. D.↗

Heating-related flows in cool solar loops

The effects of spatial and temporal variations in the heating of cool loop models are investigated in an attempt to explain the net redshifts that are observed on the sun. The response of initially static cool loops to changes in the energy input is simulated. For hot loops, it is found that spatially asymmetric changes produce a final steady state that is dynamic, and that spatially symmetric changes produce a final state that is static. Some general properties of cool loop equilibria are discussed, emphasizing the relationship between structure and energy input. The results are unable to explain the net redshifts observed in emission lines formed near 100,000 K on the sun.

Klimchuk, J. A.↗

Hot streaks and phantom cooling in a turbine rotor passage. I - Separate effects

Experimental documentation and analytical correlations demonstrating the effects of hot streak accumulation and phantom cooling on turbine rotor airfoil surface temperature. Test results are shown for a range of controlling variables to identify where streak accumulation and phantom cooling are most likely to be strongest. These variables include streak injection location, streak-to-free stream density ratio and coolant-to-free stream density and velocity ratios.

Roback, Richard J.↗

Aerosol-driven droplet concentrations dominate coverage and water of oceanic low-level clouds

A lack of reliable estimates of cloud condensation nuclei (CCN) aerosols over oceans has severely limited our ability to quantify their effects on cloud properties and extent of cooling by reflecting solar radiation—a key uncertainty in anthropogenic climate forcing. We introduce a methodology for ascribing cloud properties to CCN and isolating the aerosol effects from meteorological effects. Its application showed that for a given meteorology, CCN explains three-fourths of the variability in the radiative cooling effect of clouds, mainly through affecting shallow cloud cover and water path. This reveals a much greater sensitivity of cloud radiative forcing to CCN than previously reported, which means too much cooling if incorporated into present climate models. This suggests the existence of compensating aerosol warming effects yet to be discovered, possibly through deep clouds.

Science & Technology - Other Topics↗

Greater vulnerability of snowmelt-fed river thermal regimes to a warming climate

While the advective flux from cool melt runoff can be a significant source of thermal energy to mountainous rivers, it has been a much less addressed process in river temperature modeling and thus our understanding is limited with respect to the spatiotemporal effect of melt on river temperatures at the watershed scale. In particular, the extent and magnitude of the melt cooling effect in the context of a warming climate are not yet well understood. To address this knowledge gap, we improved a coupled hydrology and stream temperature modeling system, Distributed Hydrology Soil Vegetation Model and River Basin Model (DHSVM-RBM), to account for the thermal effect of cool snowmelt runoff on river temperatures. The model was applied to a snow-fed river basin in the Pacific Northwest to evaluate the responses of snow, hydrology, stream temperatures, and potential fish growth to future climates. Historical simulations suggest that snowmelt can notably reduce the basin-wide peak summer temperatures particularly at high-elevation tributaries, while the thermal impacts of melt water can persist through the summer along the mainstem. Ensemble climate projections suggested that a warming climate will decrease basin mean peak snow and summer streamflow by 92% and 60% by the end of the century. Due to the compounded influences of warmer temperatures, lower flows and diminished cooling from melt, rivers reaches in high elevation snow-dominated areas were projected to be most vulnerable to future climate change, showing the largest increases in summer peak temperatures. As a result, thermal habitat used by anadromous Pacific salmon was projected to exhibit substantially lower growth potential during summer in future. These results have demonstrated the necessity of accounting for snowmelt influence on stream temperature modeling in mountainous watersheds.

54 ENVIRONMENTAL SCIENCES↗