Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

A direct electron detector for time-resolved MeV electron microscopy

The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here in this paper, we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.

36 MATERIALS SCIENCE↗

Multivariate statistical analysis software technologies for astrophysical research involving large data bases

We developed a package to process and analyze the data from the digital version of the Second Palomar Sky Survey. This system, called SKICAT, incorporates the latest in machine learning and expert systems software technology, in order to classify the detected objects objectively and uniformly, and facilitate handling of the enormous data sets from digital sky surveys and other sources. The system provides a powerful, integrated environment for the manipulation and scientific investigation of catalogs from virtually any source. It serves three principal functions: image catalog construction, catalog management, and catalog analysis. Through use of the GID3* Decision Tree artificial induction software, SKICAT automates the process of classifying objects within CCD and digitized plate images. To exploit these catalogs, the system also provides tools to merge them into a large, complete database which may be easily queried and modified when new data or better methods of calibrating or classifying become available. The most innovative feature of SKICAT is the facility it provides to experiment with and apply the latest in machine learning technology to the tasks of catalog construction and analysis. SKICAT provides a unique environment for implementing these tools for any number of future scientific purposes. Initial scientific verification and performance tests have been made using galaxy counts and measurements of galaxy clustering from small subsets of the survey data, and a search for very high redshift quasars. All of the tests were successful, and produced new and interesting scientific results. Attachments to this report give detailed accounts of the technical aspects for multivariate statistical analysis of small and moderate-size data sets, called STATPROG. The package was tested extensively on a number of real scientific applications, and has produced real, published results.

Djorgovski, S. George↗

Multivariate Statistical Analysis Software Technologies for Astrophysical Research Involving Large Data Bases

We developed a package to process and analyze the data from the digital version of the Second Palomar Sky Survey. This system, called SKICAT, incorporates the latest in machine learning and expert systems software technology, in order to classify the detected objects objectively and uniformly, and facilitate handling of the enormous data sets from digital sky surveys and other sources. The system provides a powerful, integrated environment for the manipulation and scientific investigation of catalogs from virtually any source. It serves three principal functions: image catalog construction, catalog management, and catalog analysis. Through use of the GID3* Decision Tree artificial induction software, SKICAT automates the process of classifying objects within CCD and digitized plate images. To exploit these catalogs, the system also provides tools to merge them into a large, complex database which may be easily queried and modified when new data or better methods of calibrating or classifying become available. The most innovative feature of SKICAT is the facility it provides to experiment with and apply the latest in machine learning technology to the tasks of catalog construction and analysis. SKICAT provides a unique environment for implementing these tools for any number of future scientific purposes. Initial scientific verification and performance tests have been made using galaxy counts and measurements of galaxy clustering from small subsets of the survey data, and a search for very high redshift quasars. All of the tests were successful and produced new and interesting scientific results. Attachments to this report give detailed accounts of the technical aspects of the SKICAT system, and of some of the scientific results achieved to date. We also developed a user-friendly package for multivariate statistical analysis of small and moderate-size data sets, called STATPROG. The package was tested extensively on a number of real scientific applications and has produced real, published results.

Djorgovski, S. G.↗

Experimental Measurements of Short-Lived Fission Products from Uranium, Neptunium, Plutonium and Americium

Fission yields are especially well characterized for long-lived fission products. Modeling techniques incorporate numerous assumptions and can be used to deduce information about the distribution of short-lived fission products. This work is an attempt to gather experimental (model-independent) data on the short-lived fission products. Fissile isotopes of uranium, neptunium, plutonium and americium were irradiated under pulse conditions at the Washington State University 1 MW TRIGA reactor to achieve ~108 fissions. The samples were placed on a HPGe (high purity germanium) detector to begin counting in less than 3 minutes post irradiation. The samples were counted for various time intervals ranging from 5 minutes to 1 hour. The data was then analyzed to determine which radionuclides could be quantified and compared to the published fission yield data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A GAMMA RAY SCANNING APPROACH TO QUANTIFY SPENT FUEL CASK RADIONUCLIDE CONTENTS

The International Atomic Energy Agency (IAEA) has outlined a need to develop methods of allowing re-verification of LWR spent fuel stored in dry storage casks without the need of a reference baseline measurement. Some scanning methods have been developed, but improvements can be made to readily provide required data for spent fuel cask verification. The scanning process should be conditioned to both confirm the contents and detect any changes due to container/contents degradation or unauthorized removal or tampering. Savannah River National Laboratory and The University of Tennessee are exploring a new method of engineering a high efficiency, cost effective detection system, capable of meeting the above defined requirements in a variety of environmental situations. An array of NaI(Tl) detectors, arranged to form a 'line scan' along with a matching array of 'honeycomb' collimators provide a precisely defined field of view with minimal degradation of intrinsic detection efficiency and with significant scatter rejection. Scanning methods are adapted to net optimum detection efficiency of the combined system. In this work, and with differing detectors, a series of experimental demonstrations are performed that map system spatial performance and counting capability before actual spent fuel cask scans are performed. The data are evaluated to demonstrate the prompt ability to identify missing fuel rods or other content abnormalities. To also record and assess cask tampering, the cask is externally examined utilizing FTIR hyper spectral and other imaging/sensing approaches. This provides dated records and indications of external abnormalities (surface deposits, smears, contaminants, corrosion) attributable to normal degradation or to tampering. This paper will describe the actual gathering of data in both an experimental climate and from an actual spent fuel dry storage cask, and how an evaluation may be performed by an IAEA facility inspector attempting to draw an independent safeguards conclusion concerning the status of the special nuclear material.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mercat

Mercat is a highly scalable property software package for robust of analysis of features in next-generation sequencing data and observed unique peptides from metaproteomic data. Mercat is offered in python 3.5/anaconda3, is multiparellel and is easily installed using bioconda/conda recipes. Mercat inputs include assembled contigs, raw sequence reads from any platform, and unique peptide files obtained from proteomics with feature abundance counts tables. Mercat is the only software available that allows for direct analysis of data properties without a data-dependent search tools such as BLAST or diamond for compositional analysis of whole community shotgun sequencing (e.g. metagenomes and/or metatranscriptomes) or metaproteomic data.

Source record↗

Mercat

Mercat is a highly scalable property software package for robust of analysis of features in next-generation sequencing data and observed unique peptides from metaproteomic data. Mercat is offered in python 3.5/anaconda3, is multiparellel and is easily installed using bioconda/conda recipes. Mercat inputs include assembled contigs, raw sequence reads from any platform, and unique peptide files obtained from proteomics with feature abundance counts tables. Mercat is the only software available that allows for direct analysis of data properties without a data-dependent search tools such as BLAST or diamond for compositional analysis of whole community shotgun sequencing (e.g. metagenomes and/or metatranscriptomes) or metaproteomic data.

Source record↗

Using Process Load Cell Information for IAEA Safeguards at Enrichment Plants

Uranium enrichment service providers are expanding existing enrichment plants and constructing new facilities to meet demands resulting from the shutdown of gaseous diffusion plants, the completion of the U.S.-Russia highly enriched uranium downblending program, and the projected global renaissance in nuclear power. The International Atomic Energy Agency (IAEA) conducts verification inspections at safeguarded facilities to provide assurance that signatory States comply with their treaty obligations to use nuclear materials only for peaceful purposes. Continuous, unattended monitoring of load cells in UF{sub 6} feed/withdrawal stations can provide safeguards-relevant process information to make existing safeguards approaches more efficient and effective and enable novel safeguards concepts such as information-driven inspections. The IAEA has indicated that process load cell monitoring will play a central role in future safeguards approaches for large-scale gas centrifuge enrichment plants. This presentation will discuss previous work and future plans related to continuous load cell monitoring, including: (1) algorithms for automated analysis of load cell data, including filtering methods to determine significant weights and eliminate irrelevant impulses; (2) development of metrics for declaration verification and off-normal operation detection ('cylinder counting,' near-real-time mass balancing, F/P/T ratios, etc.); (3) requirements to specify what potentially sensitive data is safeguards relevant, at what point the IAEA gains on-site custody of the data, and what portion of that data can be transmitted off-site; (4) authentication, secure on-site storage, and secure transmission of load cell data; (5) data processing and remote monitoring schemes to control access to sensitive and proprietary information; (6) integration of process load cell data in a layered safeguards approach with cross-check verification; (7) process mock-ups constructed to provide simulated load cell data; (8) hardware and software implementation for process load cell data collection; (9) costs associated with unattended monitoring of load cells (for both operator and inspector) weighed against the potential benefits of having access to such data; (10) results from field tests of load cell data collection systems in operating facilities; and (11) use of unattended load cell data to increase efficiency of on-site inspection schedules and activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data-optimized source modeling with the Backwards Liouville Test–Kinetic method

In the standard practice of neutron multiplicity counting , the first three sampled factorial moments of the event triggered neutron count distribution were used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. Our study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra, Italy, sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-Stream PIV Measurements of Jets With Internal Lobed Mixers

With emphasis being placed on enhanced mixing of jet plumes for noise reduction and on predictions of jet noise based upon turbulent kinetic energy, unsteady measurements of jet plumes are a very important part of jet noise studies. Given that hot flows are of most practical interest, optical techniques such as Particle Image Velocimetry (PIV) are applicable. When the flow has strong azimuthal features, such as those generated by chevrons or lobed mixers, traditional PIV, which aligns the measurement plane parallel to the dominant flow direction is very inefficient, requiring many planes of data to be acquired and stacked up to produce the desired flow cross-sections. This paper presents PIV data acquired in a plane normal to the jet axis, directly measuring the cross-stream gradients and features of an internally mixed nozzle operating at aircraft engine flow conditions. These nozzle systems included variations in lobed mixer penetration, lobe count, lobe scalloping, and nozzle length. Several cases validating the accuracy of the PIV data are examined along with examples of its use in answering questions about the jet noise generation processes in these nozzles. Of most interest is the relationship of low frequency aft-directed noise with turbulence kinetic energy and mean velocity.

Bridges, James↗

In Situ Measurement of Tritium Permeation Through Stainless Steel

The TMIST-2 irradiation experiment was conducted in the Advanced Test Reactor at Idaho National Laboratory to evaluate tritium permeation through Type 316 stainless steel (316 SS). The interior of a 316 SS seamless tube specimen was exposed to a 4He carrier gas mixed with a specified quantity of tritium (T2) to yield partial pressures of 0.1, 5, and 50 Pa at 292° and 330°C. In-situ tritium permeation measurements were made by passing a He-Ne sweep gas over the outer surface of the specimen to carry the permeated tritium to a bubbler column for liquid scintillation counting. An irradiation enhancement factor (IEF) was determined by comparing in-situ permeation data with a correlation for ex-reactor hydrogen permeation through austenitic stainless steel developed from literature data and reported by Le Claire. Nominal values for the IEF ranged between 3 and 5 for 316 SS. In-situ permeation data were also used to derive an in-reactor permeation correlation as a function of temperature and pressure. In addition, the triton recoil contribution to tritium permeation, which results from the transmutation of 3He to T, was also evaluated by introducing a 4He carrier gas mixed with 3He at a partial pressure of 1013 Pa at 330°C. Less than 3% of the tritium resulting from 3He transmutation contributed to tritium permeation.

In-Reactor↗

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Multiple Changepoint Detection for Non‐Gaussian Time Series

ABSTRACT This article combines methods from existing techniques to identify multiple changepoints in non‐Gaussian autocorrelated time series. A transformation is used to convert a Gaussian series into a non‐Gaussian series, enabling penalized likelihood methods to handle non‐Gaussian scenarios. When the marginal distribution of the data is continuous, the methods essentially reduce to the change of variables formula for probability densities. When the marginal distribution is count‐oriented, Hermite expansions and particle filtering techniques are used to quantify the scenario. Simulations demonstrating the efficacy of the methods are given and two data sets are analyzed: 1) the proportion of home runs hit by Major League Baseball batters from 1920 to 2023 and 2) a six‐dimensional series of tropical cyclone counts from the Earth's basins of generation from 1980 to 2023. In the first series, beta marginal distributions are used to describe the proportions; in the second, Poisson marginal distributions seem appropriate.

Lund, Robert [Department of Statistics University ↗

Data for: Climatic Imprint on Interfacially-Controlled Platinum-Palladium Resources

Data package for manuscript "Climatic Imprint on Interfacially-Controlled Platinum-Palladium Resources" by Emily G. Wright, Ivey Wang, Yihang Fang, Elaine D. Flynn, and Jeffrey G. Catalano. This dataset contains adsorption results from experiments designed to investigate the effect of chloride on Pd(II) adsorption to goethite and Pt(II) adsorption to hematite and goethite, including lab experiments, X-ray absorption fine structure spectroscopy, and models of retention within a laterite. See the associated manuscript for full methods information. The file "Wright2025_PtAds_data.csv" contains the target starting Pt concentration (uM), final aqueous Pt and associated error (in uM), calculated adsorbed Pt and associated error (in umol/m2), target and measured aqueous chloride (mM), target aqueous nitrate (mM), final pH, and mineral concentration/loading (g/L). Associated mineral-free controls (mineral loading = 0 g/L) are included; the aqueous Pd error was not calculated and chloride was not measured in every sample. These data appear in Figures 1, S3, S4, S5, S20, and S22 in the associated manuscript. The file "Wright2025_PdAds_data.csv" contains the target starting Pd concentration (uM), final aqueous Pd and associated error (in uM), calculated adsorbed Pd and associated error (in umol/m2), target and measured aqueous chloride (mM), and mineral concentration/loading (g/L). Associated mineral-free controls (mineral loading = 0 g/L) are included; the aqueous Pd error was not calculated and chloride was not measured in every sample. These data appear in Figures 1, S3, S4, S5, and S20 in the associated manuscript. The file "Wright2025_MineralBatches_data.csv" contains the mineral identity and BET specific surface area (m2/g) for every mineral batch synthesized and used in experiments. The annealing time used is listed for hydrothermally annealed goethite. These data appear in Table S2 in the associated manuscript. The file "Wright2025_XRD_data.csv" contains the XRD patterns for every mineral batch synthesized as the counts as a function of two theta (in degrees). See "Wright2025_MineralBatches_data.csv" for more details on specific mineral batches. These data appear in Figure S2 in the associated manuscript. The file "Wright 2025_ZetaPotential_data.csv" contains the measured zeta potentials for samples of goethite (batch G2) at pH 4 the presence of varying amounts of sodium chloride. These data appear in Table S3 in the associated manuscript. The file "Wright2025_XAFSSamples_data.csv" contains the specific mineral batch, measured final aqueous Pd or Pt (uM), measured final aqueous chloride (mM), and estimated adsorbed Pd or Pt (umol/m2) of all XAFS samples. These data appear in Tables S4, S7, S8, and S10 in the associated manuscript. The files "Wright2025_PdXAFS_data.csv" and "Wright2025_PtXAFS_data.csv" contain the normalized spectra of Pd and Pt, respectively, adsorbed to minerals at varying chloride concentrations. See "Wright2025_XAFSSamples_data.csv" for a guide to sample names. Note that "05" in a sample name is equivalent to "0.5". These data appear in Figures 2, S6, S7, S8, S12, S13, and S14 in the associated manuscript. The file "Wright2025_LateriteProfileProfileModelParameters_data.csv" include the ratio of hematite to hematite and goethite in two synthetic, modeled profiles, as well as the modeled surface areas of goethite and hematite as a function of relative depth within the modeled weathering zone. These data were used, in conjunction with equations presented in the paper, to calculate the theoretical concentrations of Pd and Pt (and the resulting Pt/Pd ratio) within the profiles. These data appear in Figure 3 in the associated manuscript. The file "Wright2025_Imagery_data.zip" is a zipped folder containing the TEM and STEM images appear in Figures S18 and S19. Individual files are labeled as either STEM (Fig. S18) or TEM (Fig. S19) with a letter representing the part of the multipart figure.

58 GEOSCIENCES↗

Calibration of the AVHRR visible and near IR channels using radiances measured over remote ocean areas

An inflight absolute calibration method has been adapted and applied to channel 1 of the AVHRR. The approach is based on AVHRR observations in channels 1, 2 and 4. A rigorous cloud screening is performed, based on the homogeneity of the data in channel 1 and 2 and on the temperature in channel 4. In a combined approach, the off-nadir view satellite count in channel 2 is used to detect the aerosol optical thickness and loading and the count of channel 1 is used to calibrate this channel, based on the predictable Rayleigh scattering component. Water vapor data are used, and the channels are intercalibrated using the ratio between channels 1 and 2 over the glint region.

Vermote, Eric F.↗

Application of modern autoradiography to nuclear forensic analysis

Modern autoradiography techniques based on phosphorimaging technology using image plates (IPs) and digital scanning can identify heterogeneities in activity distributions and reveal material properties, serving to inform subsequent analyses. Here, we have adopted these advantages for applications in nuclear forensics, the technical analysis of radioactive or nuclear materials found outside of legal control to provide data related to provenance, production history, and trafficking route for the materials. IP autoradiography is a relatively simple, non-destructive method for sample characterization that records an image reflecting the relative intensity of alpha and beta emissions from a two-dimensional surface. Such data are complementary to information gathered from radiochemical characterization via bulk counting techniques, and can guide the application of other spatially resolved techniques such as scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS). IP autoradiography can image large 2-dimenstional areas (up to 20 × 40 cm), with relatively low detection limits for actinides and other radioactive nuclides, and sensitivity to a wide dynamic range (10 5 ) of activity density in a single image. Distributions of radioactivity in nuclear materials can be generated with a spatial resolution of approximately 50 μm using IP autoradiography and digital scanning. While the finest grain silver halide films still provide the best possible resolution (down to ~10 μm), IP autoradiography has distinct practical advantages such as shorter exposure times, no chemical post-processing, reusability, rapid plate scanning, and automated image digitization. Sample preparation requirements are minimal, and the analytical method does not consume or alter the sample. These advantages make IP autoradiography ideal for routine screening of nuclear materials, and for the identification of areas of interest for subsequent micro-characterization methods. Here in this article we present a summary of our setup, as modified for nuclear forensic sample analysis and related research, and provide examples of data from select samples from the nuclear fuel cycle and historical nuclear test debris.

07 ISOTOPE AND RADIATION SOURCES↗

Wide Field Imaging of the Hubble Deep Field-South Region III: Catalog

We present 1/2 square degree uBVRI imaging around the Hubble Deep Field - South. These data have been used in earlier papers to examine the QSO population and the evolution of the correlation function in the region around the HDF-S. The images were obtained with the Big Throughput Camera at CTIO in September 1998. The images reach 5 sigma limits of u approx. 24.4, B approx. 25.6, V approx. 25.3, R approx. 24.9 and I approx. 23.9. We present a catalog of approx. 22,000 galaxies. We also present number-magnitude counts and a comparison with other observations of the same field. The data presented here are available over the world wide web.

Palunas, Povilas↗

Statistical analysis of the performance and long-term stability of unquenched LSC standards ( 3 H, 14 C) used for radiochemical measurements

Multiple sets of toluene-based unquenched standards, procured over the last 3 decades, were analyzed to determine their stability over time. A statistical analysis was performed to provide insight into the variability for tSIE and counting efficiency measurements of 3 H and 14 C isotopes. Our data suggests that standards remain viable even 30 years after the manufacturer’s recommended expiration date. Overall, these standards have shown no statistically significant sign of performance degradation. We have proven through statistical analysis that these standards can provide comparable performance over time well past their manufactured expiration date.

LSC standards↗