Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Variability of Marine Aerosol Fine-Mode Fraction and Estimates of Anthropogenic Aerosol Component Over Cloud-Free Oceans from the Moderate Resolution Imaging Spectroradiometer (MODIS)

In this study, we examine seasonal and geographical variability of marine aerosol fine-mode fraction (f(sub m)) and its impacts on deriving the anthropogenic component of aerosol optical depth (tau(sub a)) and direct radiative forcing from multispectral satellite measurements. A proxy of f(sub m), empirically derived from the Moderate Resolution Imaging Spectroradiometer (MODIS) Collection 5 data, shows large seasonal and geographical variations that are consistent with the Goddard Chemistry Aerosol Radiation Transport (GOCART) and Global Modeling Initiative (GMI) model simulations. The so-derived seasonally and spatially varying f(sub m) is then implemented into a method of estimating tau(sub a) and direct radiative forcing from the MODIS measurements. It is found that the use of a constant value for fm as in previous studies would have overestimated Ta by about 20% over global ocean, with the overestimation up to 45% in some regions and seasons. The 7-year (2001-2007) global ocean average tau(sub a) is 0.035, with yearly average ranging from 0.031 to 0.039. Future improvement in measurements is needed to better separate anthropogenic aerosol from natural ones and to narrow down the wide range of aerosol direct radiative forcing.

Yu, Hongbin↗

First Direct Imaging and Profiling TOF-SIMS Studies on Cutouts from Cavities Prepared by State-of-the-Art Treatments

Small amounts of interstitial impurities in the penetra-tion depth of superconducting radio frequency (SRF) cavities have a dramatic effect on the quality factors and maximum accelerating gradients. Here we report the first TOF-SIMS studies of cutouts from cavities prepared by all modern surface treatments, which allow a direct corre-lation of the impurity distribution with the observed cavity performance. Imaging capability of our instrument allows to avoid the possible issues associated with the ‘‘ghost’’ depth profiles appearing as a consequence of particulate surface contamination, which likely caused the inconclusive SIMS results on e.g. oxygen diffusion in the past.

43 PARTICLE ACCELERATORS↗

MO-AB-206-00: Nuclear Medicine Physics and Testing

This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images for SPECT reconstructions. Become knowledgeable of items to be included in annual acceptance testing reports including CT dosimetry and PACS monitor measurements. T. Turkington, GE Healthcare.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-AB-206-01: PET Physics

This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images for SPECT reconstructions. Become knowledgeable of items to be included in annual acceptance testing reports including CT dosimetry and PACS monitor measurements. T. Turkington, GE Healthcare.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-AB-206-02: Testing Gamma Cameras Based On TG177 WG Report

This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images for SPECT reconstructions. Become knowledgeable of items to be included in annual acceptance testing reports including CT dosimetry and PACS monitor measurements. T. Turkington, GE Healthcare.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-FG-BRA-06: Systematic Study of Target Localization for Bioluminescence Tomography Guided Radiation Therapy for Preclinical Research

Purpose: To overcome the limitation of CT/CBCT in guiding radiation for soft tissue targets, we developed a bioluminescence tomography(BLT) system for preclinical radiation research. We systematically assessed the system performance in target localization and the ability of resolving two sources in simulations, phantom and in vivo environments. Methods: Multispectral images acquired in single projection were used for the BLT reconstruction. Simulation studies were conducted for single spherical source radius from 0.5 to 3 mm at depth of 3 to 12 mm. The same configuration was also applied for the double sources simulation with source separations varying from 3 to 9 mm. Experiments were performed in a standalone BLT/CBCT system. Two sources with 3 and 4.7 mm separations placed inside a tissue-mimicking phantom were chosen as the test cases. Live mice implanted with single source at 6 and 9 mm depth, 2 sources with 3 and 5 mm separation at depth of 5 mm or 3 sources in the abdomen were also used to illustrate the in vivo localization capability of the BLT system. Results: Simulation and phantom results illustrate that our BLT can provide 3D source localization with approximately 1 mm accuracy. The in vivo results are encouraging that 1 and 1.7 mm accuracy can be attained for the single source case at 6 and 9 mm depth, respectively. For the 2 sources study, both sources can be distinguished at 3 and 5 mm separations at approximately 1 mm accuracy using 3D BLT but not 2D bioluminescence image. Conclusion: Our BLT/CBCT system can be potentially applied to localize and resolve targets at a wide range of target sizes, depths and separations. The information provided in this study can be instructive to devise margins for BLT-guided irradiation and suggests that the BLT could guide radiation for multiple targets, such as metastasis. Drs. John W. Wong and Iulian I. Iordachita receive royalty payment from a licensing agreement between Xstrahl Ltd and Johns Hopkins University.

60 APPLIED LIFE SCIENCES↗

SU-E-J-215: Onboard Split PET Including the Effects of Attenuation, Scatter, and Random Events

Purpose: Positron emission tomography (PET) using split PET geometry was investigated as an on-board system for functional imaging and PET marker tracking, specifically with tomotherapy. The open dual ring PET would allow measurement of both inter and intra-fractional variation, improving the delineation of tumor volume at any stage in the radiation treatment delivery process. We present results from data obtained using Monte Carlo simulations including the effects of attenuation, random events, and scatter. Methods: PET design was accomplished via Monte Carlo simulations with GATE, the Geant4 Application for Emission Tomography. Images were reconstructed using Software for Image Reconstruction (STIR) with a fully 3D ordered subset expectation maximization (OSEM) image reconstruction technique. Results: Monte Carlo simulations of the split PET geometry indicate that including physical factors that degrade image quality such as attenuation, random events, and scatter still prove the feasibility of near real-time PET for both inter and intra-fractional radiation delivery. The image quality of scan times under 1 minute reveals that it is possible to utilize PET scanning and reconstruction during the treatment session intrafractionally. GATE also simulates the depth information but does not correct obliqueness of the path of line of response so the data is much more realistic than the data obtained with ray tracing. Conclusion: Onboard split PET with TomoTherapy can generate quality images under 1 minute scan times without the need to correct for attenuation, scatter, random events, or depth information of the interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Nanoimaging of Crystal Defects in Single Grains of Solid-State Electrolyte Li 7–3x Al x La 3 Zr 2 O 12

All-solid-state lithium batteries promise significant improvements in energy density and safety over traditional liquid electrolyte batteries. The Al-doped Li 7 La 3 Zr 2 O 12 (LLZO) solid-state electrolyte shows excellent potential given its high ionic conductivity and good thermal, chemical, and electrochemical stability. Nevertheless, further improvements on electrochemical and mechanical properties of LLZO call for an in-depth understanding of its local microstructure. Here, we employ Bragg coherent diffractive imaging to investigate the atomic displacements inside single grains of LLZO with various Al-doping concentrations, resulting in cubic, tetragonal, and cubic-tetragonal mixed structures. We observe coexisting domains of different crystallographic orientations in the tetragonal structure. We further show that Al doping leads to crystal defects such as dislocations and phase boundaries in the mixed- and cubic-phase grain. This study addresses the effect of Al doping on the nanoscale structure within individual grains of LLZO, which is informative for the future development of solid-state batteries.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Can We Rely on Satellite Visible/Infrared Microphysical Retrievals of Boundary Layer Clouds in Partially Cloudy Scenes? Implications for Climate Research

This study addresses the longstanding question of the reliability of gridded visible/infrared satellite cloud properties in partially cloudy scenes. By using in-situ cloud probes and airborne Research Scanning Polarimeter (RSP) observations, we analyze bias changes in satellite retrievals from the Spinning Enhanced Visible Infra-Red Imager (SEVIRI) geostationary sensor during the ORACLES campaign. Biases in cloud optical depth (τ) and droplet effective radius (r e ) modestly change for cloud area fraction greater than 35%. The agreement between SEVIRI and RSP r e substantially improves when the retrievals are averaged after removing pixels with τ < 3.0, yielding biases indistinguishable from overcast scenes. In addition, satellite and RSP show an excellent agreement for closed- and open-cell stratocumulus clouds, showing that the satellite retrievals capture spatial changes of r e , and confirming that satellites can faithfully reproduce real physical features for optically thick and partially cloudy scenes. We demonstrate that a simple methodology can minimize uncertainties in satellite-based climate studies.

Painemal, David [NASA Langley Research Center, Ham↗

Single-molecule reaction mapping uncovers diverse behaviours of electrocatalytic surface Pd–H intermediates

Many vital electrocatalytic transformations hinge on reactive surface metal–hydrogen intermediates (M–H*), yet the low concentration and transient nature of such intermediates present formidable challenges to in-depth investigation. Here we use single-molecule super-resolution reaction imaging to directly probe surface palladium–hydrogen (Pd–H*) intermediates on individual palladium nanocubes during electrocatalytic hydrogen evolution. Our approach visualizes hydrogen spillover from palladium to the surrounding substrate surface over hundreds of nanometres away and dissects substantial inter- and intraparticle heterogeneity. Through Gaussian-broadening kinetic analysis, we reveal that ensemble-averaged measurements systematically overestimate the stability of Pd–H*. Moreover, we resolve three subpopulations of palladium nanocubes with distinct reactivity features, uncovering critical correlations between intermediate stability, hydrogenation reactivity and transition-state properties. Finally, our findings highlight the necessity of single-particle resolution for capturing the intrinsic complexity of electrocatalysts; our approach is also broadly applicable to interrogate surface-reactive intermediates across a wide array of electrocatalytic pathways.

electrocatalysis↗

Ultrafast imaging of transient electronic plasmas produced in conditions of femtosecond waveguide writing in dielectrics

Femtosecond laser-induced plasmas in bulk dielectrics are imaged under waveguide writing conditions, for different polarizations, pulse durations, and processing depths, and their temporal evolution is measured using ultrafast pump-probe microscopy. The irradiation beam profile is elliptically shaped yielding a disklike focal volume. We demonstrate for doped phosphate glass that increasing the pulse duration improves the spatial distribution of deposited energy by minimizing beam filamentation and prefocal depletion effects. As a consequence, energy deposition in the desired volume is greatly enhanced. Our results identify key parameters for optimizing femtosecond laser processing of dielectrics and different strategies to minimize energy loss channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WISE/NEOWISE OBSERVATIONS OF COMET 103P/HARTLEY 2

We report results based on mid-infrared photometry of comet 103P/Hartley 2 taken during 2010 May 4-13 (when the comet was at a heliocentric distance of 2.3 AU, and an observer distance of 2.0 AU) by the Wide-field Infrared Survey Explorer. Photometry of the coma at 22 {mu}m and data from the University of Hawaii 2.2 m telescope obtained on 2010 May 22 provide constraints on the dust particle size distribution, d log n/d log m, yielding power-law slope values of alpha = -0.97 {+-} 0.10, steeper than that found for the inbound particle fluence during the Stardust encounter of comet 81P/Wild 2. The extracted nucleus signal at 12 {mu}m is consistent with a body of average spherical radius of 0.6 {+-} 0.2 km (one standard deviation), assuming a beaming parameter of 1.2. The 4.6 {mu}m band signal in excess of dust and nucleus reflected and thermal contributions may be attributed to carbon monoxide or carbon dioxide emission lines and provides limits and estimates of species production. Derived carbon dioxide coma production rates are 3.5({+-} 0.9) x 10{sup 24} molecules per second. Analyses of the trail signal present in the stacked image with an effective exposure time of 158.4 s yields optical-depth values near 9 x 10{sup -10} at a delta mean anomaly of 0.2 deg trailing the comet nucleus, in both 12 and 22 {mu}m bands. A minimum chi-squared analysis of the dust trail position yields a beta-parameter value of 1.0 x 10{sup -4}, consistent with a derived mean trail-grain diameter of 1.1/{rho} cm for grains of {rho} g cm{sup -3} density. This leads to a total detected trail mass of at least 4 x 10{sup 10} {rho} kg.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of enamel caries lesions in rat molars using synchrotron X-ray microtomography

Dental caries is a ubiquitous infectious disease with a nearly 100% lifetime prevalence. Rodent caries models are widely used to investigate the etiology, progression and potential prevention or treatment of the disease. To explore the suitability of these models for deeper investigations of intact surface zones during enamel caries, the structures of early-stage carious lesions in rats were characterized and compared with previous reports on white spot enamel lesions in humans. Synchrotron X-ray microcomputed tomography non-destructively mapped demineralization in carious rat molar specimens across a range of caries severity, identifying 52 lesions across the 30 teeth imaged. Of these lesions, 13 were shown to have intact surface zones. Depth profiles of fractional mineral density were qualitatively similar to lesions in human teeth. However, the thickness of the surface zone in the rat model ranges from 10 to 58 µm, and is therefore significantly thinner than in human enamel. These results indicate that a fraction of lesions in rat caries possess an intact surface zone and are qualitatively similar to human lesions at the micrometer scale. This suggests that rat caries models may be a suitable analog through which to investigate the structure of surface zone enamel and its role during dental caries.

60 APPLIED LIFE SCIENCES↗

A simple approach to using an amorphous silicon EPID to verify IMRT planar dose maps

A simplified method of verifying intensity modulated radiation therapy (IMRT) fields using a Varian aS500 amorphous silicon electronic portal imaging device (EPID) is demonstrated. Unlike previous approaches, it does not involve time consuming or complicated analytical processing of the data. The central axis pixel response of the EPID, as well as the profile characteristics obtained from images acquired with a 6 MV photon beam, was examined as a function of field size. Ion chamber measurements at various depths in a water phantom were then collected and it was found that at a specific depth d{sub ref}, the dose response and profile characteristics closely matched the results of the EPID analysis. The only manipulation required to be performed on the EPID images was the multiplication of a matrix of off axis ratio values to remove the effect of the flood field calibration. Similarly, d{sub ref} was found for 18 MV. Planar dose maps at d{sub ref} in a water phantom for a bar pattern, a strip pattern, and 14 clinical IMRT fields from two patient cases each being from a separate anatomical region, i.e., head and neck as well as the pelvis, for both energies were generated by the Pinnacle planning system (V7.4). EPID images of these fields were acquired and converted to planar dose maps and compared directly with the Pinnacle planar dose maps. Radiographic film dosimetry and a MapCHECK dosimetry device (Sun Nuclear Corporation, Melbourne, FL) were used as an independent verification of the dose distribution. Gamma analysis of the EPID, film, and Pinnacle planar dose maps generated for the clinical IMRT fields showed that approximately 97% of all points passed using a 3% dose/3mm DTA tolerance test. Based on the range of fields studied, the author's results appear to justify using this approach as a method to verify dose distributions calculated on a treatment planning system, including complex intensity modulated fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of Nitrogen Absorption Rate and Nitride Growth on SRF Cavity Grade RRR Niobium as a Function of Furnace Temperature

The current state of the art processing of niobium superconducting radio frequency cavities with nitrogen diffusion is performed at 800 C in a furnace with a partial pressure of approximately ~20 mTorr of nitrogen. Multiple studies have shown the bulk of the nitrogen absorbed by the niobium forms a thick (1-3 microns) non-superconducting nitride layer which must be removed to produce optimal RF results. The depth profiling of interstitial nitrogen and surface nitrides has already been probed using SIMS measurements for this recipe. These measurements have been successfully modelled by extrapolating data from nitride growth studies performed at atmospheric pressure and temperatures above 1000 C.1 One open question is whether there is a diffusion-only zone at lower temperature in the ~20 mTorr range in which the niobium will absorb nitrogen but not create a non-superconducting nitride layer; or is the absorption of nitrogen only possible by first forming a nitride buffer layer which then frees up nitrogen for absorption which is what has been shown down to 600 C at atmospheric pressures on long time scales. A systematic study of absorption vs. temperature and correlated SIMS measurements is required to answer this question. We report on measurements of the parabolic rate constant vs. temperature from 400 C to 900 C of cavity grade niobium with metallurgically flat witness samples. Depth profiles of witness samples using SIMS are presented together with SEM imaging for nitride crystals and correlated with N absorption.

Reece, Charles↗

Innovative computational tools for reducing exploration risk through integration of water-rock interactions and magnetotelluric surveys

Mapping permeability distributions in geothermal reservoirs is essential for reducing the cost of geothermal development. To avoid the cost and sampling bias of measuring permeability directly through drilling, we require remote methods of imaging permeability such as geophysics. Electrical resistivity (or its inverse, conductivity) is one of the most sensitive geophysical properties known to reflect long range fluid interconnection and thus the likelihood of permeability. Perhaps the most widely applied geophysical methods for imaging subsurface resistivity is magnetotellurics (MT) due to its relatively great penetration depths. A primary goal of this project is to confirm through ground truthing at existing geothermal systems that MT resistivity structure interpreted integratively is capable of revealing permeable fluid pathways into geothermal systems.

15 GEOTHERMAL ENERGY↗

The Origin of Faint Tidal Features around Galaxies in the RESOLVE Survey

We study tidal features around galaxies in the REsolved Spectroscopy Of a Local VolumE (RESOLVE) survey. Our sample consists of 1048 RESOLVE galaxies that overlap with the DECam Legacy Survey, which reaches an $r$-band 3$σ$ depth of ~27.9 mag arcsec -2 for a 100 arcsec 2 feature. Images were masked, smoothed, and inspected for tidal features such as streams, shells, or tails/arms. We find tidal features in 17± 2 % of our galaxies, setting a lower limit on the true frequency. The frequency of tidal features in the gas-poor (gas-to-stellar mass ratio <0.1) subsample is lower than in the gas-rich subsample (13± 3 % versus 19± 2 %). Within the gas-poor subsample, galaxies with tidal features have higher stellar and halo masses, ~3× closer distances to nearest neighbors (in the same group), and possibly fewer group members at fixed halo mass than galaxies without tidal features, but similar specific star formation rates. These results suggest tidal features in gas-poor galaxies are typically streams/shells from dry mergers or satellite disruption. In contrast, the presence of tidal features around gas-rich galaxies does not correlate with stellar or halo mass, suggesting these tidal features are often tails/arms from resonant interactions. Similar to tidal features in gas-poor galaxies, tidal features in gas-rich galaxies imply 1.7× closer nearest neighbors in the same group; however, they are associated with diskier morphologies, higher star formation rates, and higher gas content. In addition to interactions with known neighbors, we suggest that tidal features in gas-rich galaxies may arise from accretion of cosmic gas and/or gas-rich satellites below the survey limit.

79 ASTRONOMY AND ASTROPHYSICS↗

Forecasting the northern African dust outbreak towards Europe in April 2011: A model intercomparison

In the framework of the World Meteorological Organisation's Sand and Dust Storm Warning Advisory and Assessment System, we evaluated the predictions of five state-of-the-art dust forecast models during an intense Saharan dust outbreak affecting western and northern Europe in April 2011. We assessed the capacity of the models to predict the evolution of the dust cloud with lead times of up to 72 h using observations of aerosol optical depth (AOD) from the AErosol RObotic NETwork (AERONET) and the Moderate Resolution Imaging Spectroradiometer (MODIS) and dust surface concentrations from a ground-based measurement network. In addition, the predicted vertical dust distribution was evaluated with vertical extinction profiles from the Cloud and Aerosol Lidar with Orthogonal Polarization (CALIOP). To assess the diversity in forecast capability among the models, the analysis was extended to wind field (both surface and profile), synoptic conditions, emissions and deposition fluxes. Models predict the onset and evolution of the AOD for all analysed lead times. On average, differences among the models are larger than differences among lead times for each individual model. In spite of large differences in emission and deposition, the models present comparable skill for AOD. In general, models are better in predicting AOD than near-surface dust concentration over the Iberian Peninsula. Models tend to underestimate the long-range transport towards northern Europe. In this paper, our analysis suggests that this is partly due to difficulties in simulating the vertical distribution dust and horizontal wind. Differences in the size distribution and wet scavenging efficiency may also account for model diversity in long-range transport.

54 ENVIRONMENTAL SCIENCES↗