Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Reception-Conversion Subsystem (RXCV) for microwave power transmission system

As part of a program to demonstrate the feasibility of power transmission from space, an approximately 25 sq m Reception-Conversion Subsystem was designed and tested. The device collects high power microwave energy, converts it into dc, and dissipates it in an instrumented demonstration load.

Raytheon Company↗

Quantitative measurement of surface contamination

Portable and highly sensitive system permits quantitative determinations on test surfaces. Device is used in normal room light and permits detection of significantly smaller samples. Digitation of output permits easy evaluation of contamination cleanup techniques.

Richmond, R. G.↗

Conference on Charge-Coupled Device Technology and Applications

Papers were presented from the conference on charge coupled device technology and applications. The following topics were investigated: data processing; infrared; devices and testing; electron-in, x-ray, radiation; and applications. The emphasis was on the advances of mutual relevance and potential significance both to industry and NASA's current and future requirements in all fields of imaging, signal processing and memory.

Source record↗

On adaptive modal control of large flexible spacecraft

A recently developed strategy for adaptive sampled-data control of distributed parameter systems based on a plant modal expansion description and modal simultaneous identification and regulation algorithms is presented with frequent reference to the annular momentum control device (AMCD) test example. The requirements of observation spillover reduction and modal eigenvector shape prespecification, which are especially crucial to the proposed adaptive control strategy, are addressed. Individual low pass time filtering of sensed AMCD particle displacements is proposed for observation spillover reduction. A layered scheme incorporating 'eigenvector' shape improvement is outlined to combat the expansion basis prespecification requirement.

Johnson, C. R., Jr.↗

Portable zero-delay assembly

Instrument is calibrated using back-to-back method. In comparison standard, S-X isolators are opposite from device being tested to permit signal flow in reverse direction. After calibration portable zero-delay assembly (PZDA) is used to set time delays of deep-space network ground-station ranging systems. Approach is also used to calibrate microwave links in other communications systems.

Franco, M. M.↗

Steady generation of aerosols with an improved constant output atomizer

It is common practice to generate laboratory aerosols of soluble materials with pneumatic atomizers. In a typical device, a solution of the substance to be aerosolized is injected into a jet of air and the liquid is broken up into very small droplets. After forced evaporation, a dry aerosol of the solute is produced. A number of commercially available devices were tested, and despite differences in design, all the atomizers tested suffered from short- and/or long-term fluctuations of their output particle number concentrations. The mechanisms responsible for atomizer instabilities are discussed and methods for alleviating these problems are considered.

Dea, J. Y.↗

Passive and Active Control of Space Structures (PACOSS)

Passive and Active Control of Space Structures (PACOSS) is a five-year program designed to investigate highly damped structures in conjunction with active control systems, and in particular to develop technology that integrates passive damping and active control to achieve precise pointing control. Major areas of research include metal matrix composites; viscoelastic materials; damping devices; dynamic test article design, fabrication and testing; and active damping.

Morosow, G.↗

Device and method for frictionally testing materials for ignitability

Test apparatus for determining ignition characteristics of various metal in oxidizer environments simulating operating conditions for materials is invented. The test apparatus has a chamber through which the oxidizing agent flows, and means for mounting a stationary test sample therein, a powered, rotating shaft in the chamber rigidly mounts a second test sample. The shaft is axially movable to bring the samples into frictional engagement and heated to the ignition point. Instrumentation connected to the apparatus provides for observation of temperatures, pressures, loads on and speeds of the rotating shaft, and torques whereby components of stressed oxygen systems can be selected which will avoid accidental fires under working conditions.

Benz, F. J.↗

Optical Detection Of Cryogenic Leaks

Conceptual system identifies leakage without requiring shutdown for testing. Proposed device detects and indicates leaks of cryogenic liquids automatically. Detector makes it unnecessary to shut equipment down so it can be checked for leakage by soap-bubble or helium-detection methods. Not necessary to mix special gases or other materials with cryogenic liquid flowing through equipment.

Wyett, Lynn M.↗

Surface temperature measurements using a thin film thermal array

A thin film device was designed and fabricated to measure surface temperatures. An array of eight integrated thermal sensors are mounted on a 0.002 inch (0.05 mm) Kapton film and multiplexed to obtain an area thermal measurement. The device was tested on a flat plate airfoil and demonstrated a temperature variation of 0.55 C maximum and 0.05 C minimum compared to embedded thermocouples. Future improvements are also discussed.

Dillon-Townes, L. A.↗

Experimental investigation of a new device to control the asymmetric flowfield on forebodies at large angles of attack

An exploratory experimental investigation of a new device to control the asymmetric flowfield on forebodies at large angles of attack has been conducted. The device is a rotatable forebody tip, which varies in cross section from circular at its base to elliptic at its tip. The device itself extends over a small portion of the aircraft or missile forebody. The device provides two important improvements. First, it replaced the normally random behavior of the nose side force as a function of nose tip orientation with a predictable and generally sinusoidal distribution and, second, the device showed promise for use as part of a vehicle control system, to be deflected in a prescribed manner to provide additional directional control for the vehicle. The device was tested on a cone/cylinder model having a 10 deg semiapex angle and on a 3.0 caliber tangent ogive model, each with a base diameter of 3.5 in, for angles of attack from 30 to 60 deg. Data were taken from 3 circumferential rows of pressure taps on each model at a Reynolds number of 84,000 based on cylinder diameter and by a helium-bubble flow visualization technique at a Reynolds number of 24,000.

Moskovitz, Cary A.↗

An approach to space power

Fusion offers the potential for a very high specific power, providing a large specific impulse that can be traded-off with thrust for mission optimization. Thus fusion is a leading candidate for missions beyond the moon. A new approach is discussed for space fusion power, namely Inertial Electrostatic Confinement (IEC). This method offers a high power density in a relatively small, simple device. It appears capable of burning aneutronic fuels which are most desirable for space applications and is well suited for direct conversion. An experimental device to test the concept is described.

Miley, G. H.↗

Planar doped barrier subharmonic mixers

The Planar Doped Barrier (PDB) diode is a device consisting of a p(+) doping spike between two intrinsic layers and n(+) ohmic contacts. This device has the advantages of controllable barrier height, diode capacitance and forward to reverse current ratio. A symmetrically designed PDB has an anti-symmetric current vs. voltage characteristic and is ideal for use as millimeter wave subharmonic mixers. We have fabricated such devices with barrier heights of 0.3, 0.5 and 0.7 volts from GaAs and InGaAs using a multijunction honeycomb structure with junction diameters between one and ten microns. Initial RF measurements are encouraging. The 0.7 volt barrier height 4 micron GaAs devices were tested as subharmonic mixers at 202 GHz with an IF frequency of 1 GHz and had 18 dB of conversion loss. The estimated mismatch loss was 7 dB and was due to higher diode capacitance. The LO frequency was 100.5 GHz and the pump power was 8 mW.

Lee, T. H.↗