Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Testing and operating a multiprocessor chip with processor redundancy

A system and method for improving the yield rate of a multiprocessor semiconductor chip that includes primary processor cores and one or more redundant processor cores. A first tester conducts a first test on one or more processor cores, and encodes results of the first test in an on-chip non-volatile memory. A second tester conducts a second test on the processor cores, and encodes results of the second test in an external non-volatile storage device. An override bit of a multiplexer is set if a processor core fails the second test. In response to the override bit, the multiplexer selects a physical-to-logical mapping of processor IDs according to one of: the encoded results in the memory device or the encoded results in the external storage device. On-chip logic configures the processor cores according to the selected physical-to-logical mapping.

97 MATHEMATICS AND COMPUTING↗

Stability of CIGS Solar Cells and Component Materials Evaluated by a Step-Stress Accelerated Degradation Test Method: Preprint

A step-stress accelerated degradation testing (SSADT) method was employed for the first time to evaluate the stability of CuInGaSe2 (CIGS) solar cells and device component materials in four Al-framed test structures encapsulated with an edge sealant and three kinds of backsheet or moisture barrier film for moisture ingress control. The SSADT exposure used a 15 degrees C and then a 15% relativehumidity (RH) increment step, beginning from 40 degrees C/40%RH (T/RH = 40/40) to 85 degrees C/70%RH (85/70) as of the moment. The voluminous data acquired and processed as of total DH = 3956 h with 85/70 = 704 h produced the following results. The best CIGS solar cells in sample Set-1 with a moisture-permeable TPT backsheet showed essentially identical I-V degradation trend regardless of theAl-doped ZnO (AZO) layer thickness ranging from standard 0.12 um to 0.50 um on the cells. No clear 'stepwise' feature in the I-V parameter degradation curves corresponding to the SSADT T/RH/time profile was observed. Irregularity in I-V performance degradation pattern was observed with some cells showing early degradation at low T/RH < 55/55 and some showing large Voc, FF, and efficiency degradation due to increased series Rs (ohm-cm2) at T/RH = 70/70. Results of (electrochemical) impedance spectroscopy (ECIS) analysis indicate degradation of the CIGS solar cells corresponded to increased series resistance Rs (ohm) and degraded parallel (minority carrier diffusion/recombination) resistance Rp, capacitance C, overall time constant Rp*C, and 'capacitor quality' factor (CPE-P), whic were related to the cells' p-n junction properties. Heating at 85/70 appeared to benefit the CIGS solar cells as indicated by the largely recovered CPE-P factor. Device component materials, Mo on soda lime glass (Mo/SLG), bilayer ZnO (BZO), AlNi grid contact, and CdS/CIGS/Mo/SLG in test structures with TPT showed notable to significant degradation at T/RH = 70/70. At T/RH = 85/70, substantial blistering of BZO layers on CIGS cell pieces was observed that was not seen on BZO/glass, and a CdS/CIGS sample displayed a small darkening and then flaking feature. Additionally, standard AlNi grid contact was less stable than thin Ni grid contact at T/RH = 70/70. The edge sealant and moisture-blocking films were effective to block moisture ingress, as evidenced by the good stability of most CIGS solar cells and device components at T/RH = 85/70 for 704 h, and by preservation of the initial blue color on the RH indicator strips. The SSADT experiment is ongoing to be completed at T/RH = 85/85.

14 SOLAR ENERGY↗

Ultra-High Efficiency and Stable All-Perovskite Tandem Solar Cells

In the project period, the research team has fabricated more than 6,000 single-junction wide-bandgap (wide-E g ) and low-bandgap (low-E g ) perovskite solar cells (PSCs) and more than 2,000 all-perovskite tandem solar cells (APTSCs). The best-performing wide-E g and low-E g PSCs and APTSCs showed PCEs greater than 19%, 23%, and 30%, respectively. The average PCEs for wide-E g and low-E g PSCs and APTSCs fabricated by the benchmark processes are (18.5 ± 0.4)%, (21.9 ± 0.8)%, and (26.8 ± 2.1)%, respectively. We have demonstrated APTSCs with T 80 lifetime of more than 1,000 h, which were measured by maximum power point tracking (MPPT) under one sun operation in the air. The team has also utilized various advanced characterization techniques to study the optical and electrical properties of wide-E g and low-E g perovskite materials and devices, developing a better understanding of the unique working principle and degradation mechanism of APTSCs. The team has met most GNG decision criteria except for the stability goal of APTSCs under 85 °C/85 RH accelerated lifetime test (ALT). The shortfall of the device ALT stability is mainly limited by the intrinsic instability of Sn-Pb perovskites under illumination at elevated temperatures. The team discussed with stakeholders in the PV academic and industry about these durability concerns and concluded that this is the major technical barrier preventing the market entry of APTSCs. Future fundamental study and R&D work are needed to advance this promising technology.

14 SOLAR ENERGY↗

Development of 3D diamond detectors for detector applications at ultra high luminosity facilities

During this project our group has succeeded in producing and measuring a number of 3D diamond devices. We have worked with manufacturers and shown that poly-crystalline CVD (pCVD) diamond can be grown reliably with a 5% uniformity in industry. We have produced 3D diamond devices and scaled up the production technology from roughly 100 cells on a device to 4000 cells on a device. We have increased the column yield from 92% to 99%. We have reduced the cell size from our safe initial choice 150μm x 150μm cells to the HL-LHC size of 50μm x 50μm cells. We have reduced the column diameter from 6-10 μm to 2.6 μm. In beam tests we have quantified the amount of charge each 3D device yields for minimizing ionizing particles and compared this to that produced by a planar diamond device. Very recently, we produced the first 3D diamond pixel devices read out with both ATLAS and CMS pixel electronics, tested them in particle beams at CERN and PSI. Finally we have successfully tested the first irradiated 3Ddiamond device after a fluence of 3.5 x 10 15 800 MeV p/cm 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioactive Contamination Tenacity on Building Substrate - 17417

Radiological decontamination is an essential enterprise that has become more important over the last four decades due to unfortunate accidents and the threat of terrorist actions. Decontamination can be an effective, beneficial alternative for the cleanup of radiological contamination events; however, the costs and benefits need to be balanced against those for complete removal and demolition of contaminated areas or facilities. Demolition and removal are often the first options considered in such circumstances as decontamination may be thought of as slow and costly. Decontamination has advantages, including significant waste reduction over demolition. In areas with buildings of cultural or societal importance, demolition may not be an option. Three decontamination evaluation test series are the focus of this article: SIMCON 1 and 2 (i.e., simulated contamination), and Urban RDD (radiological dispersal device, i.e., a dirty bomb detonation). These test series revealed that different contaminants respond differently during decontamination. This was found to be true with both SIMCON and Urban RDD simulant tests. SIMCON 2 especially demonstrated that chemically different contaminants respond differently to different decontamination methods: cesium appears to be less tenacious (more easily removed) than zirconium using chemical methods. These differences were underscored by the Urban RDD tests where americium and cobalt tended to precipitate on high pH surfaces (such as concrete), making them easier to remove, while cesium and strontium were essentially unaffected by surface pH and were imbibed more strongly into the substrate pore structure. While authorities argue over the contributions of contaminant chemistry and substrate morphology, the clear answer is that each has a contribution to the tenacity of a contaminant. Knowing how these characteristics interact will make us better at decontamination in the field. This knowledge refutes the efforts of perhaps well-meaning marketers to define our decontamination problems by what products they are trying to sell; often a 'one size fits all' type approach. Knowing even a little bit about the character of the decontamination problem will save time and money and increase the efficacy of decontamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid state streak camera prototype performance testing and future upgrades

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolving diagnostics for studying events that occur on the nanosecond to microsecond time scales. The Nevada National Security Site (NNSS) and Sandia National Laboratories (SNL) have built a 42-channel solid state streak camera (SSSC) prototype as a proof of concept for use as a streak camera replacement. This work is part of an ongoing project to develop the technology to a level competitive with analog streak cameras. This manuscript discusses the device concept, results from electronic and laser testing, and recent improvements to increase the device’s dynamic range.

Plasma diagnostics - interferometry, spectroscopy ↗

Radioactive Contamination Tenacity on Building Substrate – 17417

Radiological decontamination is an essential enterprise that has become more important over the last four decades due to unfortunate accidents and the threat of terrorist actions. Decontamination can be an effective, beneficial alternative for the cleanup of radiological contamination events; however, the costs and benefits need to be balanced against those for complete removal and demolition of contaminated areas or facilities. Demolition and removal are often the first options considered in such circumstances as decontamination may be thought of as slow and costly. Decontamination has advantages, including significant waste reduction over demolition. In areas with buildings of cultural or societal importance, demolition may not be an option. Three decontamination evaluation test series are the focus of this article: SIMCON 1 and 2 (i.e., simulated contamination), and Urban RDD (radiological dispersal device, i.e., a dirty bomb detonation). These test series revealed that different contaminants respond differently during decontamination. This was found to be true with both SIMCON and Urban RDD simulant tests. SIMCON 2 especially demonstrated that chemically different contaminants respond differently to different decontamination methods: cesium appears to be less tenacious (more easily removed) than zirconium using chemical methods. These differences were underscored by the Urban RDD tests where americium and cobalt tended to precipitate on high pH surfaces (such as concrete), making them easier to remove, while cesium and strontium were essentially unaffected by surface pH and were imbibed more strongly into the substrate pore structure. While authorities argue over the contributions of contaminant chemistry and substrate morphology, the clear answer is that each has a contribution to the tenacity of a contaminant. Knowing how these characteristics interact will make us better at decontamination in the field. This knowledge refutes the efforts of perhaps well-meaning marketers to define our decontamination problems by what products they are trying to sell; often a “one size fits all” type approach. Knowing even a little bit about the character of the decontamination problem will save time and money and increase the efficacy of decontamination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and testing of an improved dosimetry system using a backscatter shielded electronic portal imaging device

Purpose: To investigate the properties of a modified backscatter shielded electronic portal imaging device (BSS-EPID) and to develop a dose model to convert BSS-EPID images to dose in water as part of an improved system for dosimetry using EPIDs. Methods: The effectiveness of the shielding of the BSS-EPID was studied by comparing images measured with the BSS-EPID mounted on the support arm to images measured with the BSS-EPID removed from the support arm. A dose model was developed and optimized to reconstruct dose in water at different depths from measured BSS-EPID images. The accuracy of the dose model was studied using BSS-EPID images of 28 IMRT fields to reconstruct dose in water at depths of 2, 5, 10, and 20 cm and comparing to measured dose in water from a two-dimensional diode array at the same depths. The ability of the BSS-EPID system to operate independently of detector position was demonstrated by comparing the dose reconstruction of a 10 x 10 cm{sup 2} field using different detector offsets to that measured by a two-dimensional diode array. Results: The shielding of the BSS-EPID was found to be effective, with more than 99% of pixels showing less than 0.5% change due to the presence of the support arm and at most a 0.2% effect on the central axis for 2 x 2 cm{sup 2} fields to fully open 30 x 40 cm{sup 2} images. The dose model was shown to accurately reconstruct measurements of dose in water using BSS-EPID images with average {gamma} pass rates (2%, 2 mm criteria) of 92.5%, 98.7%, 97.4%, and 97.2% at depths of 2, 5, 10, and 20 cm, respectively, when compared to two-dimensional diode array measurements. When using 3%, 3 mm {gamma} criteria, the average pass rate was greater than 97% at all depths. Reconstructed dose in water for a 10 x 10 cm{sup 2} field measured with detector offsets as large as 10 cm agreed with each other and two-dimensional diode array measurements within 0.9%. Conclusions: The modified BSS-EPID and associated dose model provide an improved system for dosimetry measurements using EPIDs. Several important limitations of the current hardware and software are addressed by this system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Interface–Type Memristive Device for Artificial Synapse and Neuromorphic Computing

Interface-type (IT) metal/oxide Schottky memristive devices have attracted considerable attention over filament-type (FT) devices for neuromorphic computing because of their uniform, filament-free, and analog resistive switching (RS) characteristics. The most recent IT devices are based on oxygen ions and vacancies movement to alter interfacial Schottky barrier parameters and thereby control RS properties. However, the reliability and stability of these devices have been significantly affected by the undesired diffusion of ionic species. Herein, a reliable interface-dominated memristive device is demonstrated using a simple Au/Nb-doped SrTiO 3 (Nb:STO) Schottky structure. The Au/Nb:STO Schottky barrier modulation by charge trapping and detrapping is responsible for the analog resistive switching characteristics. Because of its interface-controlled RS, the proposed device shows low device-to-device, cell-to-cell, and cycle-to-cycle variability while maintaining high repeatability and stability during endurance and retention tests. Furthermore, the Au/Nb:STO IT memristive device exhibits versatile synaptic functions with an excellent uniformity, programmability, and reliability. A simulated artificial neural network with Au/Nb:STO synapses achieves a high recognition accuracy of 94.72% for large digit recognition from MNIST database. These results suggest that IT resistive switching can be potentially used for artificial synapses to build next-generation neuromorphic computing.

36 MATERIALS SCIENCE↗

Development and Experimental Validation of a High-Power DC Distribution Testbed for Advanced Charging Infrastructure and Energy Management

This paper presents the development of a hardware testbed for DC-distributed high-power charging (HPC) stations. As DC distributed solutions emerge as a viable solution to optimize HPC site operations, challenges such as interoperability, protection, and seamless integration of distributed energy resources (DER) persist. These issues underscore the need for a robust testing facility to investigate compliance of available commercial off-the-shelf (COTS) market devices. The developed testbed features a DC-distributed charging hub including a charger, emulated energy storage system (ESS), and site level communication and controller implementation. It facilitates the testing of COTS hardware, charger prototypes, standards validation and site energy management system (SEMS) controllers at rated power. This paper details the development of the charging infrastructure platform, implementation of communication system, validation of different SEMS algorithms, and understanding improvements required for future expansion. Using the developed testbed, interoperability gaps for SEMS implementation with multi-vehicle concurrent charging via a multi-port charger are experimentally observed. Aimed at supporting the transition to large-scale EV charging infrastructure deployment and DER integration, this testbed plays a crucial role in conformity testing of COTS device interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Noise Amplifiers and Superconducting Flex Circuits for Frequency Domain Multiplexed Readout of Detector Arrays

The next-generation ground-based cosmic microwave background (CMB) experimental program aims to provide definitive measurements of the early universe using telescopes configured with large focal plane arrays requiring ~100,000 detectors and associated readout amplifiers and interconnecting components that are currently unavailable commercially. We describe research to demonstrate the feasibility of developing low-noise cryogenic amplifiers based on series SQUID arrays that are suitable for frequency domain multiplexed readout of large numbers of CMB detectors, and the feasibility of developing robust superconducting flex cables that will simplify cryogenic systems integration for large CMB instruments. Two iterations of prototype series SQUID array amplifier designs were completed. The designs were optimized using modeling and simulation tools to meet the requirements for CMB detector readouts. Two fabrication runs were completed, and a large number of devices from each design iteration were tested and characterized at 4 K. We also completed the development of processes for the fabrication of prototype superconducting flex cables on 4" wafers. Samples were tested for strength and robustness, and to determine the critical current at 4 K as a function of trace width. The new generation of series SQUID array amplifier designs exhibit excellent performance characteristics – very smooth output characteristics that simplify tuning and operation, low input inductance, low current noise referred to the input, and low power dissipation that for the first time will enable these devices to be operated at the focal plane array stage of CMB instruments. The processes developed in Phase I to produce superconducting flex cables were used to complete the fabrication of a full wafer with several test and sample flex circuits. The 6-micron thick flex material is very strong with a breaking strength of several pounds for a 20-mm wide strip. Critical current density was reasonable and scaled with trace width as expected.

79 ASTRONOMY AND ASTROPHYSICS↗

Emulator apparatus for microgrid testing and design

An emulator apparatus that emulates entities included in a microgrid is described herein. The emulator apparatus emulates a load with time-varying inductance/resistance or an energy storage device or combination of energy storage devices. The emulator apparatus is electrically coupled to a system or device that is desirably tested/maintained/designed. The emulator apparatus emulates a particular device, and response of the system of device to the emulated device is monitored for purposes of design, testing, or maintenance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TrustDER: Trusted, Private and Scalable Coordination of Distributed Energy Resources

In this project, the Stanford and SLAC Teams have developed a Trusted, Private and Scalable platform for coordinating Coordination of Distributed Energy Resources (TrustDER). This is a layered system that ensures private, trusted and scalable coordination and monitoring of DERs. It accommodates a variety of resources, such as solar generation, gensets and loads, with a particular focus on battery systems-based resources, as they are a transformational technology experiencing fast growth in adoption by large critical facilities. The platform can be used as standalone or added to existing aggregation systems to enable trust, privacy and resilience. TrustDER consists of layers that address each of the shortcomings of the existing state of the art. Each layer in the platform can operate independently but provides information to the layers above it to enable a novel form of overall coordination architecture. The project consists of several tasks, with each task dedicated to the design of each layer. Task 2 Resource Virtualization defined a software abstraction layer for distributed energy resources (DERs). The goal of this abstraction was to simplify the implementation of algorithms utilizing cooperation of DERs resources in a variety of use cases. Task 3 is on Secure ID for Asset Authentication. Identity Management Systems (IDMS) are a foundational infrastructure for interactions between entities (organizations, users, devices, and services). Secure ID is blockchain-based a distributed identity management system allowing (1) identity provisioning, (2) authentication, (3) authorization, and (4) identity data sharing for IoT-enabled assets on the electricity grid. In this project, the SLAC team focused on designing and testing Keymaker, a protocol for authenticating device identity managed by Secure ID. Task 5 Private and Safe Integration is focused on the design and evaluation of a DER cooperation scheme which allows for the aggregation of DERs without impacting network reliability. The approach is designed based on realistic assumptions regarding data availability, communication infrastructure limitations, and privacy. Task 6 Scalable Distributed Privacy for Information explored how virtualized batteries could be managed privately. Specifically, it examined the case in which a principal provides a partitioned battery to multiple clients. Task 7 Use Cases was to ensure that this technology was applied in relevant situations and scenarios. Primarily, this means that virtualization needed to be employed in a manner that either improved flexibility, bolstered security or privacy, or decreased costs.

25 ENERGY STORAGE↗

Elements configuration of the open lead test circuit

In the field of electronics, small electronic devices are widely utilized because they are easy to carry. The devices have various functions by user’s request. Therefore, the lead’s pitch or the ball’s pitch have been narrowed and high-density printed circuit board has been used in the devices. Use of the ICs which have narrow lead pitch makes normal connection difficult. When logic circuits in the devices are fabricated with the state-of-the-art technology, some faults have occurred more frequently. It can be divided into types of open faults and short faults. We have proposed a new test method using a test circuit in the past. This paper propose elements configuration of the test circuit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a reliable, miniaturized hydrogen safety sensor prototype

In this article, the development and long-term testing of a hydrogen safety sensor for vehicle and infrastructure applications is presented. The working device is demonstrated through application of commercial and reproducible manufacturing methods and rigorous life testing results guided by materials selection, and sensor design. Fabricated using Indium Tin Oxide (ITO) as the sensing electrode, Yttria-Stabilized Zirconia (YSZ) as an oxygen ion conducting solid electrolyte and Platinum (Pt) as a pseudo-counter electrode, the device was subjected to interference studies, temperature cycling, and long-testing routine. The sensor responded in real time to varying concentrations of H{sub 2} (1000 to 20,000 ppm) monitored under a humidified condition. Among the interference gases tested such as nitric oxide (NO), nitrogen dioxide (NO{sub 2}), ammonia (NH{sub 3}), carbon monoxide (CO), and propylene (C{sub 3}H{sub 6}), the sensor showed cross-sensitivity to C{sub 3}H{sub 6}. Analyzing the overall device performance over 4000 hrs of testing for 5000 ppm of H{sub 2}, (a) the sensitivity varied {+-}21% compared to response recorded at 0 hrs, and (c) the response rise time fluctuated between 3 to 46 s. The salient features of the H{sub 2} sensor prototype designed and co-developed by Los Alamos National Laboratory (LANL) are (a) stable three phase interface (electrode/electrolyte/gas) leading to reliable sensor operation, (b) low power consumption, (b) compactness to fit into critical areas of application, (c) simple operation, (d) fast response, (e) a direct voltage read-out circumventing the need for any additional conditioning circuitry, and (f) conducive to commercialization.

30 DIRECT ENERGY CONVERSION↗

FOSWEC dynamics and controls test report

This report describes the testing of a model scale wave energy converter. This device, which uses two aps that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and ex- perimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable.

16 TIDAL AND WAVE POWER↗

High-Gradient Tests of the Single-Cell SC Cavity with a Feedback Waveguide

Use of a superconducting (SC) traveling-wave accelerating (STWA) structure with a small phase advance per cell, rather than a standing-wave structure, may provide a significant increase in the accelerating gradient in the ILC linac [1]. For the same surface electric and magnetic fields, the STWA achieves an accelerating gradient 1.2 larger than TESLA-like standing-wave cavities. In addition, the STWA allows longer acceleration cavities, reducing the number of gaps between them. However, the STWA structure requires a SC feedback waveguide to return the few hundreds of MW of circulating RF power from the structure output to the structure input. A test single-cell cavity with feedback was designed and manufactured to demonstrate the possibility of proper processing to achieve a high accelerating gradient. The first results of high-gradient tests of a prototype 1.3 GHz single-cell cavity with feedback waveguide will be presented.

43 PARTICLE ACCELERATORS↗