Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed control and optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Coordinated Model Predictive Control on Multi-Lane Roads

There are significant economic, environmental, energy, and other societal costs incurred by the road transportation sector. With the advent and penetration of connected and autonomous vehicles there are vast opportunities to optimize the control of individual vehicles for reducing energy consumption and increasing traffic flow. Model predictive control is a useful tool to achieve such goals, while accommodating ego-centric objectives typical of heterogeneous traffic and explicitly enforcing collision and other constraints. In this paper, we describe a multi-agent distributed maneuver planning and lane selection model predictive controller that includes an information sharing and coordination scheme. The energy saving potential of the proposed coordination scheme is then evaluated via large scale microscopic traffic simulations considering different penetration levels of connected and automated vehicles.

Goulet, Nathan↗

Paddle-based rotating-shield brachytherapy

Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16.6, 12.9, 7.2, 3.7, and 1.7 Gy{sub 10}, respectively. P-RSBT HR-CTV D{sub 90}-values were insensitive to the paddle size for paddles angled at less than 60°. Increasing the paddle angle from 5° to 60° resulted in only a 0.6 Gy{sub 10} decrease in HR-CTV D{sub 90} on average for five cases when the delivery times were set to 15 min/fx. The HR-CTV D{sub 90} decreased to 2.5 and 11.9 Gy{sub 10} with paddle angles of 90° and 120°, respectively. Conclusions: P-RSBT produces treatment plans that are dosimetrically and temporally superior to those of S-RSBT and D-RSBT, although P-RSBT systems may be more mechanically challenging to develop than S-RSBT or D-RSBT. A P-RSBT implementation with 4–6 shield paddles would be sufficient to outperform S-RSBT and D-RSBT if delivery times are constrained to less than 15 min/fx.

60 APPLIED LIFE SCIENCES↗

Chemical Looping Coal Gasification Sub-Pilot Unit Demonstration and Economic Assessment for IGCC applications (Final Report)

The Ohio State University (OSU) coal to syngas (CTS) technology is an advanced air separation process that can be applied for electricity production via an integrated gasification combined cycle (IGCC). The objective of the proposed project is to enable the OSU CLG technology for a commercially relevant demonstration by 2020. In order to accomplish this objective, small pilot scale demonstration of the CLG reactor system was performed. The small pilot test unit incorporates commercially scalable non-mechanical gas sealing and solids flow control components for extended operations of the integrated reactor system. A cumulative demonstration of greater than 100 hours was performed to confirm the reliability of the reactors (reducer and oxidizer) and non-mechanical devices in maintaining controlled solid circulation, gas sealing, and coal distribution in the reactor (reducer) as well as to confirm sustained syngas product performance. A comprehensive techno-economic analysis (TEA) of the OSU CLG process for IGCC application was conducted with the support of WorleyParsons, Ltd. (WP) and compared to the Department of Energy (DOE) baseline IGCC report. Using the data gained from the small pilot demonstration, a complete comprehensive techno-economic analysis (TEA) of the CLG process was conducted. The evaluation was used as basis to attract utilities and coal industries in Ohio. The project duration lasts 30 months (6 months of no cost extension). Ohio coal was used in the integrated CLG small pilot unit to convert to high hydrogen syngas. A demonstration of the integrated chemical looping reactor system at the 15 kW th scale accelerates technology commercialization in the near term. The 15 kWth demonstration addressed several major technology gaps, such as coal injection and distribution in the reducer, controllable solids circulation with the desired fuel to solids ratio, system pressure distribution for proper gas sealing, effects of contaminants and fuel/oxygen carrier residence time requirements. The fates of impurities, such as SO x and NO x was also investigated in unit demonstrations. WP conducted a comprehensive system TEA to optimize the OSU CLG process design for efficient electricity generation with greater than 90% CO 2 capture in IGCC applications. The conclusion of this project supports the further scale-up of the technology to a commercially applicable large pilot scale test unit for operation by 2020. More importantly, it benefits Ohio as it provides an economically competitive mean for power generation with carbon capture. Given the rise of natural gas usage and strict environmental regulations, the use of Ohio coal is expected to decrease and thus impact the coal economy in Ohio. The conclusion of this project provided way for Ohio coal to compete in the future and secure jobs in the energy sector.

01 COAL, LIGNITE, AND PEAT↗

Robust Optimized Pulse Schemes for Atomic Fountain Interferometry

The robustness of an atomic fountain interferometer with respect to variations in the initial velocity of the atoms and deviations from the optimal pulse amplitude is examined. We numerically simulate the dynamics of an interferometer in momentum space with a maximum separation of and map out the expected signal contrast depending on the variance of the initial velocity distribution and the value of the laser field amplitude. We show that an excitation scheme based on rapid adiabatic passage significantly enhances the expected signal contrast, compared to the commonly used scheme consisting of a series of and pulses. We demonstrate further substantial increase of the robustness by using optimal control theory to identify splitting and swapping pulses that perform well on an ensemble average of pulse amplitudes and velocities. Our results demonstrate the ability of optimal control to significantly enhance future implementations of atomic fountain interferometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

WE-G-16A-01: Evolution of Radiation Treatment Planning

Welcome and Introduction - Lawrence N. Rothenberg This symposium is one a continuing series of presentations at AAPM Annual Meetings on the historical aspects of medical physics, radiology, and radiation oncology that have been organized by the AAPM History Committee. Information on previous presentations including “Early Developments in Teletherapy” (Indianapolis 2013), “Historical Aspects of Cross-Sectional Imaging” (Charlotte 2012), “Historical Aspects of Brachytherapy” (Vancouver 2011), “50 Years of Women in Medical Physics” (Houston 2008), and “Roentgen's Early Investigations” (Minneapolis 2007) can be found in the Education Section of the AAPM Website. The Austin 2014 History Symposium will be on “Evolution of Radiation Treatment Planning.” Overview - Radhe Mohan Treatment planning is one of the most critical components in the chain of radiation therapy of cancers. Treatment plans of today contain a wide variety of sophisticated information conveying the potential clinical effectiveness of the designed treatment to practitioners. Examples of such information include dose distributions superimposed on three- or even four-dimensional anatomic images; dose volume histograms, dose, dose-volume and dose-response indices for anatomic structures of interest; etc. These data are used for evaluating treatment plans and for making treatment decisions. The current state-of-the-art has evolved from the 1940s era when the dose to the tumor and normal tissues was estimated approximately by manual means. However, the symposium will cover the history of the field from the late-1950's, when computers were first introduced for treatment planning, to the present state involving the use of high performance computing and advanced multi-dimensional anatomic, functional and biological imaging, focusing only on external beam treatment planning. The symposium will start with a general overview of the treatment planning process including imaging, structure delineation, assignment of dose requirements, consideration of uncertainties, selection of beam configurations and shaping of beams, and calculations, optimization and evaluation of dose distributions. This will be followed by three presentations covering the evolution of treatment planning, which parallels the evolution of computers, availability of advanced volumetric imaging and the development of novel technologies such as dynamic multi-leaf collimators and online image guidance. This evolution will be divided over three distinct periods - prior to 1970's, the 2D era; from 1980 to the mid-1990's, the 3D era; and from the mid 1990's to today, the IMRT era. When the World was Flat: The Two-Dimensional Radiation Therapy Era” - Jacob Van Dyk In the 2D era, anatomy was defined with the aid of solder wires, special contouring devices and projection x-rays. Dose distributions were calculated manually from single field, flat surface isodoses on transparencies. Precalculated atlases of generic dose distributions were produced by the International Atomic Energy Agency. Massive time-shared main frames and mini-computers were used to compute doses at individual points or dose distributions in a single plane. Beam shapes were generally rectangular, with wedges, missing tissue compensators and occasional blocks to shield critical structures. Dose calculations were measurement-based or they used primary and scatter calculations based on scatter-air ratio methodologies. Dose distributions were displayed on line printers as alpha-numeric character maps or isodose patterns made with pen plotters. More than Pretty Pictures: 3D Treatment Planning and Conformal Therapy - Benedick A. Fraass The introduction of computed tomography allowed the delineation of anatomy three-dimensionally and, supported partly by contracts from the National Cancer Institute, made possible the introduction and clinical use of 3D treatment planning, leading to development and use of 3D conformal therapy in the 1980's. 3D computer graphics and 3D anatomical structure definitions made possible Beam's Eye View (BEV) displays, making conformal beam shaping and much more sophisticated beam arrangements possible. These conformal plans significantly improved target dose coverage as well as normal tissue sparing. The use of dose volume histograms, gross/clinical/planning target volumes, MRI and PET imaging, multileaf collimators, and computer-controlled treatment delivery made sophisticated planning approaches practical. The significant improvements in dose distributions and analysis achievable with 3D conformal therapy made possible formal dose escalation and normal tissue tolerance clinical studies that set new and improved expectations for improved local control and decreasing complications in many clinical sites. From the Art to the State of the Art: Inverse Planning and IMRT - Thomas R. Bortfeld While the potential of intensity modulation was recognized in the mid- 1980's, intensity-modulated radiotherapy (IMRT) did not become a reality until the mid-1990's. Broad beams of photons could be sub-divided into narrow beamlets whose intensities could be determined using sophisticated optimization algorithms to appropriately balance tumor dose with normal tissue sparing. The development of dynamic multi-leaf collimators (on conventional linear accelerators as well as in helical delivery devices) enabled the efficient delivery of IMRT. The evolution of IMRT planning is continuing in the form of Volumetric Modulated Arc Therapy (VMAT) and through advanced optimization tools, such as multi-criteria optimization, automated IMRT planning, and robust optimization to protect dose distributions against uncertainties. IMRT also facilitates “dose painting” in which different sub-volumes of the target are prescribed different doses. Clearly, these advancements are being made possible by the increasing power and lower cost of computers and developments in other fields such as imaging and operations research. Summary - Radhe Mohan The history does not end here. The advancement of treatment planning is expected to continue, leading to further automation and improvements in conformality and robustness of dose distributions, particularly in the area of particle therapy. Radiobiological modeling will gain emphasis as part of the planning process. Learning Objectives: The scope of changes in technology and the capabilities of radiation treatment planning The impact of these changes in the quality of treatment plans and optimality of dose distributions The impact of development in other fields (imaging, computers, operations research, etc.) on the evolution of radiation treatment planning.

60 APPLIED LIFE SCIENCES↗

Advanced Transmission Technologies – GETs and HPCs Session 1: ATT Foundations and Dynamic Line Ratings (DLRs)

The INL TADA GETs Cohort Session 1, held on November 4, 2025, convened experts to address the integration of advanced transmission technologies, including Grid-Enhancing Technologies (GETs) and High Performance Conductors (HPCs), with a focus on digital assurance challenges. The session highlighted the growing importance of cybersecurity, supply chain transparency, reliability, and business risk management in deploying GETs, especially Dynamic Line Ratings (DLRs). Participants examined how expanded attack surfaces, limited vendor pools, and new regulatory requirements—such as FERC Orders 881, 2023, and 1920—are influencing utilities and technology providers. The workshop underscored the need for cyber-informed engineering, secure-by-design principles, and practical risk management strategies, while fostering collaboration and knowledge sharing among industry peers. Technical discussions covered the evolution from static to dynamic line ratings, complexities of cloud-based architectures, and NERC CIP compliance challenges. The session concluded with a collaborative risk exercise and a preview of future workshops on advanced power flow control and transmission topology optimization, reinforcing the cohort’s commitment to advancing digital assurance in the energy sector.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Investigation and Optimization of Biodiesel Chemistry for HCCI Combustion

Over the past 5 years, ORNL has run 95 diesel range fuels in homogene-ous charge compression ignition (HCCI), including 40 bio-diesels and associated diesel fuels in their blending. The bio-diesel blends varied in oxygen content, iodine number, cetane, boiling point distribution, chemical composition, and some contained nitrogen. All fuels were run in an HCCI engine at 1800 rpm, in the power range of 2.5 to 4.5 bar IMEP, using intake air heating for combustion phasing control, and at a compression ratio of 10.6. The engine response to fuel variables has been analyzed statistically. Generally, the engine responded well to fuels with lower nitrogen and oxygen, lower cetane, and lower aromatics. Because of the wide range of fuels combined in the model, it provides only a broad overview of the engine response. It is recommended that data be truncated and re-modeled to obtain finer resolution of engine response to particular fuel variables.

33 ADVANCED PROPULSION SYSTEMS↗

Control Co-Design Framework for Joint Optimization of PID Governor and Hydraulic Dynamics for a Hydropower Plant

This paper presents a control co-design (CCD) framework tailored to the hydraulic and mechanical subsystems of hydropower systems, aimed at enhancing their dynamic performance and responsiveness to grid demands. Conventional sequential design approaches often fall short in capturing the coupled interactions between plant dynamics and control objectives. The proposed CCD methodology enables simultaneous optimization of key hydro plant parameters - such as governor settings, penstock characteristics, and valve control - with the control system architecture. Results indicate that both CCD and sequential design approaches achieve comparable transient and steady-state performance, with minor discrepancies arising from differences in their optimized parameters. However, CCD demonstrates a distinct advantage by tripling the water time constant (Tw) while maintaining similar dynamic performance to the sequential approach. This increase in Tw enables optimization of penstock dimensions, as it is directly influenced by penstock design, thereby contributing to overall cost optimization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiphase Optimal and Non-Singular Power Flow by Successive Linear Approximations

We propose an optimal power flow method for multiphase power systems. The method works for both radial and meshed networks, and is able to accommodate different types of load/source connections such as wye, delta, and combination thereof. Moreover, the method generates a sequence of nonsingular points (i.e., associated with non-singular power-flow Jacobian) in the electrical state space and a corresponding sequence of power injections, which can be used in real-time control settings. Under certain conditions, the sequences attain the local minimum. The method has been tested using several typical networks, including the IEEE 37-bus and 123-bus test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Affinely Adjustable Robust Volt/VAr Control

Recent years have seen the increasing proliferation of distributed energy resources with intermittent power outputs, posing new challenges to the voltage management in distribution networks. To this end, this paper proposes a data-driven affinely adjustable robust Volt/VAr control (AARVVC) scheme, which modulates the smart inverter’s reactive power in an affine function of its active power, based on the voltage sensitivities with respect to real/reactive power injections. To achieve a fast and accurate estimation of voltage sensitivities, we propose a data-driven method based on deep neural network (DNN), together with a rule-based bus-selection process using the bidirectional search method. Our method only uses the operating statuses of selected buses as inputs to DNN, thus significantly improving the training efficiency and reducing information redundancy. Finally, a distributed consensus-based solution, based on the alternating direction method of multipliers (ADMM), for the AARVVC is applied to decide the inverter’s reactive power adjustment rule with respect to its active power. Only limited information exchange is required between each local agent and the central agent to obtain the slope of the reactive power adjustment rule, and there is no need for the central agent to solve any (sub)optimization problems. Finally, numerical results on the modified IEEE-123 bus system validate the effectiveness and superiority of the proposed data-driven AARVVC method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulating quantum-classical interfaces via the Lindblad master equation

In hybrid quantum systems, the interface between quantum and classical domains is essential for the generation, control, and measurement of quantum states. Quantum-classical interfaces (QCIs) are ubiquitous in devices such as optical modulators, quantum sensors, and signal processors, where classical signals influence quantum dynamics. In this paper, we employ the Lindblad master equation to simulate the evolution of a quantum system interacting with a classical control system. Our model captures both linear and nonlinear interactions by incorporating first- and second-order susceptibilities, and it quantifies the influence of externally applied control parameters on decoherence and state evolution. As an illustrative example, we analyze an optical modulator and demonstrate how variations in material response and drive conditions affect photon statistics, coherence, and phase-space distributions. In conclusion, the findings offer a path to an all-encompassing model for understanding and optimizing QCIs, with wide-ranging implications for the performance, design, and robustness of next-generation quantum devices.

Quantum engineering↗

Multi-Level Optimal Power Flow Solver in Large Distribution Networks

Solving optimal power flow (OPF) problems for large distribution networks incurs high computational complexity. We consider a large multi-phase distribution network of tree topology with a deep penetration of active devices. We divide the network into collaborating areas featuring subtree topology and subareas featuring subsubtree topology. We design a multilevel implementation of the primal-dual gradient algorithm to solve the voltage regulation OPF problems while preserving nodal voltage information and topological information within areas and subareas. Numerical results on a 4,521-node system verify that the proposed algorithm can significantly improve the computational speed without compromising any optimality.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Exploring the physics of cesium lead halide perovskite quantum dots via Bayesian inference of the photoluminescence spectra in automated experiment

The unique optoelectronic properties of metal halide perovskite quantum dots (QDs) make them promising candidates for applications in light-emitting diodes (LEDs), scintillators, and other photonic devices. The automated micropipetting synthesis platform equipped with an optical reader enables the opportunity for high throughput synthesis and photoluminescent (PL) characterization of metal halide perovskite QDs for the first time. Here, we explore the compositional dependence of the PL behavior and stability of the combinatorial library of cesium lead halide (CsPbX 3 ) perovskites QDs via the automated platform. To study the stability of synthesized QDs in the binary and ternary configurations, we study the time-dependent PL properties using previously developed machine learning analysis. Additionally, to systematically explore the PL behavior in the ternary CsPbX 3 QDs system, we introduce the Bayesian inference framework that allows the probabilistic fit of multiple models to the PL data and establishes both optimal model and model parameter robustly. Furthermore, these behaviors can be used as a control parameter for the navigation of the multidimensional compositional spaces in automated synthesis. Furthermore, this analysis shows the nonuniformity of the PL peak behavior in the ternary CsPbX 3 QDs system. Further, the analysis confirms narrow size distribution and good quality of CsPbBr 3 QDs alloyed with low concentrations of iodide and chloride. We note that Bayesian Inference fit parameters can be further used as a control signal for navigation of the chemical spaces in automated synthesis.

36 MATERIALS SCIENCE↗

Multi-Level Optimal Power Flow Solver in Large Distribution Networks: Preprint

Solving optimal power flow (OPF) problem for large distribution networks incurs high computational complexity. We consider a large multi-phase distribution networks of tree topology with deep penetration of active devices. We divide the network into collaborating areas featuring subtree topology and subareas featuring subsubtree topology. We design a multi-level implementation of the primal-dual gradient algorithm for solving the voltage regulation OPF problems while preserving nodal voltage information and topological information within areas and subareas. Numerical results on a 4,521-node system verifies that the proposed algorithm can significantly improve computational speed without compromising any optimality.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

Towards Optimal and Executable Distribution Grid Restoration Planning With a Fine-Grained Power-Communication Interdependency Model

Distribution service restoration (DSR) under natural disasters is always a critical and challenging problem for utility companies. An effective solution must not ignore the power-communication interdependency as various systems are getting increasingly connected in the Smart Grid era. In this paper, we propose a two-layer distribution system model with both power and communication components. Based on this model, we formulate the restoration process as a routing problem that schedules the path and action sequence of utility crews that involves repairing damaged components, closing power switches, and enabling communication paths between the control center and remote field devices. Further, we develop a simulation-based method to quantitatively evaluate the restoration process with public reference models of large-scale power systems. The experimental results show that our method improves the total restored energy up to 57.6% and reduces the recovery time up to 63% by considering the power-communication interdependency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Iterative Linearization for Phasor-Defined Optimal Power Dispatch

Optimal power flow (OPF) problems, which dispatch power targets to controllable generating units across a network, must generally account for non-convex constraints on power flow. Furthermore, adapting those problems so as to make them solvable with convex optimization techniques is an area of much academic and operational interest. In this paper, we present a method for solving OPF as a quadratic program by iteratively refining and re-initializing a linearized model of power flow based on the outputs of an associated nonlinear solver. The linear model on which we demonstrate this method is an adapted version of an approximation designed for use with unbalanced distribution networks. As an important benefit, the model allows for the explicit inclusion of nodal voltage phasor values in both the OPF problem's objective and its constraints, which opens the door to the idea of phasor-based control (PBC) design. We show in simulations on the IEEE 13-node test feeder that our method quickly converges to a set of phasor targets that are sufficiently precise for use in operations at the distribution level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗