Search NASA⌕ Search

SEARCH · Search NASA

Results for “eclipse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

The clumpy absorber in the high-mass X-ray binary Vela X-1

Bright and eclipsing, the high-mass X-ray binary Vela X-1 offers a unique opportunity to study accretion onto a neutron star from clumpy winds of O/B stars and to disentangle the complex accretion geometry of these systems. In Chandra-HETGS spectroscopy at orbital phase ~0.25, when our line of sight towards the source does not pass through the large-scale accretion structure such as the accretion wake, we observe changes in overall spectral shape on timescales of a few kiloseconds. This spectral variability is, at least in part, caused by changes in overall absorption and we show that such strongly variable absorption cannot be caused by unperturbed clumpy winds of O/B stars. We detect line features from high and low ionization species of silicon, magnesium, and neon whose strengths and presence depend on the overall level of absorption. Finally, these features imply a co-existence of cool and hot gas phases in the system, which we interpret as a highly variable, structured accretion flow close to the compact object such as has been recently seen in simulations of wind accretion in high-mass X-ray binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for the most powerful thermonuclear X-ray bursts with the Neil Gehrels Swift Observatory

We searched for thermonuclear X-ray bursts from Galactic neutron stars in all event mode data of the Neil Gehrels Swift Observatory collected until March 31, 2018. In particular, we are interested in the intermediate-duration bursts (shell flashes fueled by thick helium piles) with the ill-understood phenomenon of strong flux fluctuations. Nine such bursts have been discussed in the literature to date. Swift is particularly suitable for finding additional examples. We find and list a total of 134 X-ray bursts; 44 are detected with BAT only, 41 with XRT only, and 49 with both. Twenty-eight bursts involve automatic slews. We find 12 intermediate-duration bursts, all detected in observations involving automatic slews. Five show remarkably long Eddington-limited phases in excess of 200 s. Five show fluctuations during the decay phase; four of which are first discussed in the present study. We discuss the general properties of the fluctuations, considering also 7 additional literature cases. In general two types of fluctuations are observed: fast ones, with a typical timescale of 1 s and up and downward fluctuations of up to 70%, and slow ones, with a typical timescale of 1 min and only downward fluctuations of up to 90%. The latter look like partial eclipses because the burst decay remains visible in the residual emission. We revisit the interpretation of this phenomenon in the context of the new data set and find that it has not changed fundamentally despite the expanded data set. It is thought to be due to a disturbance of the accretion disk by outflowing matter and photons, causing obscuration and reflection due to Thompson scattering in an orbiting highly ionized cloud or structure above or below the disk. Furthermore, we discuss in detail the most pronounced burster SAX J1712.6–3739. One of the bursts from this source is unusual in that it lasts longer than 5600 s, but does not appear to be a superburst.

79 ASTRONOMY AND ASTROPHYSICS↗

'In vivo' Dosimetry in Tangential and Axilosupraclavicular Radiation Fields for Breast Cancer Postmastectomy

This work is an 'in vivo' dosimetry study for breast cancer patients, treated with external radiotherapy. Patients who have suffered a modified radical mastectomy have been included in the study. Measurements will be made with thermoluminescent dosimeters and with radiochromic films. Such dosimetry will let us know the dose distribution in the zone which the applied beams overlap and compare the measureddose with that calculated one using the Eclipse 6.5 (Varian) planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fundamental Properties of Low-Mass Stars and Brown Dwarfs

Precise measurements of the fundamental properties of low-mass stars and brown dwarfs are key to understanding the physics underlying their formation and evolution. While there has been great progress over the last decade in studying the bulk spectrophotometric properties of low-mass objects, direct determination of their masses, radii, and temperatures have been very sparse. Thus, theoretical predictions of low-mass evolution and ultracool atmospheres remain to be rigorously tested. The situation is alarming given that such models are widely used, from the determination of the low-mass end of the initial mass function to the characterization of exoplanets.An increasing number of mass, radius, and age determinations are placing critical constraints on the physics of low-mass objects. A wide variety of approaches are being pursued, including eclipsing binary studies, astrometric-spectroscopic orbital solutions, interferometry, and characterization of benchmark systems. In parallel, many more systems suitable for concerted study are now being found, thanks to new capabilities spanning both the very widest (all-sky surveys) and very narrowest (diffraction-limited adaptive optics) areas of the sky. This Cool Stars 15 splinter session highlighted the current successes and limitations of this rapidly growing area of precision astrophysics.

39↗

Dosimetric comparison of volumetric modulated Arc therapy, step-and-shoot, and sliding window IMRT for prostate cancer

This study aims to evaluate treatment plans generated by Step-and-Shoot (SS), Sliding Window (SW) and Volumetric Modulated Arc Therapy (VMAT) in order to assess the differences in dose volume histograms of planning target volume (PTV) and organs at risk (OAR), conformity indices, radiobiological evaluations, and plan quality for prostate cancer cases. Six prostate cancer patients treated in our center were selected for this retrospective study. Treatment plans were generated with Eclipse version 8.9 using 10 MV photon beams. For VMAT, Varian Rapid Arc with 1 or 2 arcs, and for SS and SW IMRT, 7-9 fields were used. Each plan had three PTVs with prescription doses of 81, 59.4, and 45 Gy to prostate, to prostate and lymph nodes, and to pelvis, respectively. Doses to PTV and OAR and the conformal indices (COIN) were compared among three techniques. The equivalent uniform dose (EUD), tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated and compared. The mean doses to the PTV prostate on average were 83 Gy and the percent differences of mean dose among all techniques were below 0.28. For bladder and rectum, the percent differences of mean dose among all techniques were below 2.2. The COIN did not favour any particular delivery method over the other. The TCP was higher with SS and SW for four patients and higher with VMAT for two patients. The NTCP for the rectum was the lowest with VMAT in five out of the six patients. The results show similar target coverage in general.

61 RADIATION PROTECTION AND DOSIMETRY↗

The new solid target system at UNAM in a self-shielded 11 MeV cyclotron

A dual beam line (BL) self-shielded RDS 111 cyclotron for radionuclide production was installed at the School of Medicine of the National Autonomous University of Mexico in 2001. One of the BL's was upgraded to Eclipse HP (Siemens) in 2008 and the second BL was recently upgraded (June 2011) to the same version with the option for the irradiation of solid targets for the production of metallic radioisotopes.

43 PARTICLE ACCELERATORS↗

Torsional energy levels of CH{sub 3}OH{sup +}/CH{sub 3}OD{sup +}/CD{sub 3}OD{sup +} studied by zero-kinetic energy photoelectron spectroscopy and theoretical calculations

The torsional energy levels of CH{sub 3}OH{sup +}, CH{sub 3}OD{sup +}, and CD{sub 3}OD{sup +} have been determined for the first time using one-photon zero kinetic energy photoelectron spectroscopy. The adiabatic ionization energies for CH{sub 3}OH, CH{sub 3}OD, and CD{sub 3}OD are determined as 10.8396, 10.8455, and 10.8732 eV with uncertainties of 0.0005 eV, respectively. Theoretical calculations have also been performed to obtain the torsional energy levels for the three isotopologues using a one-dimensional model with approximate zero-point energy corrections of the torsional potential energy curves. The calculated values are in good agreement with the experimental data. The barrier height of the torsional potential energy without zero-point energy correction was calculated as 157 cm{sup −1}, which is about half of that of the neutral (340 cm{sup −1}). The calculations showed that the cation has eclipsed conformation at the energy minimum and staggered one at the saddle point, which is the opposite of what is observed in the neutral molecule. The fundamental C–O stretch vibrational energy level for CD{sub 3}OD{sup +} has also been determined. The energy levels for the combinational excitation of the torsional vibration and the fundamental C–O stretch vibration indicate a strong torsion-vibration coupling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D printer generated thorax phantom with mobile tumor for radiation dosimetry

This article describes the design, construction, and properties of an anthropomorphic thorax phantom with a moving surrogate tumor. This novel phantom permits detection of dose both inside and outside a moving tumor and within the substitute lung tissue material. A 3D printer generated the thorax shell composed of a chest wall, spinal column, and posterior regions of the phantom. Images of a computed tomography scan of the thorax from a patient with lung cancer provided the template for the 3D printing. The plastic phantom is segmented into two materials representing the muscle and bones, and its geometry closely matches a patient. A surrogate spherical plastic tumor controlled by a 3D linear stage simulates a lung tumor’s trajectory during normal breathing. Sawdust emulates the lung tissue in terms of average and distribution in Hounsfield numbers. The sawdust also provides a forgiving medium that permits tumor motion and sandwiching of radiochromic film inside the mobile surrogate plastic tumor for dosimetry. A custom cork casing shields the film and tumor and eliminates film bending during extended scans. The phantom, lung tissue surrogate, and radiochromic film are exposed to a seven field plan based on an ECLIPSE plan for 6 MV photons from a Trilogy machine delivering 230 cGy to the isocenter. The dose collected in a sagittal plane is compared to the calculated plan. Gamma analysis finds 8.8% and 5.5% gamma failure rates for measurements of large amplitude trajectory and static measurements relative to the large amplitude plan, respectively. These particular gamma analysis results were achieved using parameters of 3% dose and 3 mm, for regions receiving doses >150 cGy. The plan assumes a stationary detection grid unlike the moving radiochromic film and tissues. This difference was experimentally observed and motivated calculated dose distributions that incorporated the phase of the tumor periodic motion. These calculations modestly improve agreement between the measured and intended doses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of reflectivity of spherically bent crystals using Kα signal from hot electrons produced by laser-matter interaction

In an experiment at the laser facility ECLIPSE of the CELIA laboratory, University of Bordeaux, we measure the reflectivity of spherically bent crystals that are commonly used to investigate the propagation of fast electrons through the Kα radiation they generate in matter. The experimental reflectivity compares well with predictions from a ray-tracing code that takes into account the specific geometry, although the crystals seem to suffer from aging problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of IMRT and VMAT using Delta4 phantom and portal dosimetry as dosimetry verification tools

In this study we analyzed and compared the dose distribution of different IMRT and VMAT plans with the intent to provide pre-treatment quality assurance using two different tools. Materials/Methods: We have used the electronic portal imaging device EPID after calibration to dose and correction for the background offset signal and also the Delta4 phantom after en evaluation of angular sensitivity. The Delta4 phantom has a two-dimensional array with ionization chambers. We analyzed three plans for each anatomical site calculated by Eclipse treatment planning system. The measurements were analyzed using γ-evaluation method with passing criteria 3% absolute dose and 3 mm distance to agreement (DTA). For all the plans the range of score has been from 97% to 99% for gantry fixed at 0° while for rotational planes there was a slightly decreased pass rates and above 95%. Point measurement with a ionization chamber were done in additional to see the accuracy of portal dosimetry and to evaluate the Delta4 device to various dose rates. Conclusions: Both Delt4 and Portal dosimetry shows good results between the measured and calculated doses. While Delta4 is more accurate in measurements EPID is more time efficient. We have decided to use both methods in the first steps of IMRT and VMAT implementation and later on to decide which of the tools to use depending on the complexity of plans, how much accurate we want to be and the time we have on the machine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

True beam commissioning experience at Nordland Hospital Trust, Norway

To evaluate the measured of all photon beam data of first Varian True Beam version 2.0 slim model, recently commissioned at Nordland Hospital Trust, Bodø. To compare and evaluate the possibility of beam matching with the Clinac2300, for the energies of 6MV and 15 MV. Materials/Methods: Measurements of PDD, OAR, and Output factors were realized with the IBA Blue-phantom with different detectors and evaluated between them for all photon energies: 6MV, 15MV, 6MV FFF and 10MV FFF. The ionization chambers used were Pin Point CC01, CC04, Semiflex CC13 and photon diode by Iba dosimetry. The data were processed using Beizer algorithm with a resolution of 1 mm. The measured depth dose curves, diagonals, OAR, and output factors were imported into Eclipse in order to calculate beam data for the anisotropic analytical algorithm (AAA version 10.0.28) for both the dataset measured with CC04 and CC13 and compared. The model head of 23EX was selected as the most near model to True Beam as a restriction of our version of Aria. It was seen that better results were achieved with the CC04 measured data as a result of better resolution. For the biggest field after 10 cm depth a larger difference is seen between measured and calculated for both dataset, but it is within the criteria for acceptance. Results: The Beam analysis criteria of 2 mm at 50% dose is achieved for all the fields accept for 40x40 that is within 3%. Depth difference at maximum dose is within 1 mm for all the fields and dose difference at 100 mm and 200 mm is lower than 1% for or all the fields. The PDD between two machines for all the fields differ after Dmax with less than 1%. For profiles in the field zone and outside field the difference is within 1% for all the fields. In the penumbra region the difference is from 2% up to 12% for big fields. As for diagonals they differ as a result of the head construction at the edge of the field and the penumbra region. The output factors differ for big fields within 5% and for the small fields within 3%. MU and dose distribution does not change for plans recalculated with the new modeled machine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the “PETawatt Aquitaine Laser”

Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ab initio modeling of 2D layered organohalide lead perovskites

A number of 2D layered perovskites A{sub 2}PbI{sub 4} and BPbI{sub 4}, with A and B mono- and divalent ammonium and imidazolium cations, have been modeled with different theoretical methods. The periodic structures have been optimized (both in monoclinic and in triclinic systems, corresponding to eclipsed and staggered arrangements of the inorganic layers) at the DFT level, with hybrid functionals, Gaussian-type orbitals and dispersion energy corrections. With the same methods, the various contributions to the solid stabilization energy have been discussed, separating electrostatic and dispersion energies, organic-organic intralayer interactions and H-bonding effects, when applicable. Then the electronic band gaps have been computed with plane waves, at the DFT level with scalar and full relativistic potentials, and including the correlation energy through the GW approximation. Spin orbit coupling and GW effects have been combined in an additive scheme, validated by comparing the computed gap with well known experimental and theoretical results for a model system. Finally, various contributions to the computed band gaps have been discussed on some of the studied systems, by varying some geometrical parameters and by substituting one cation in another’s place.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Causal interaction in high frequency turbulence at the biosphere–atmosphere interface: Structural behavior

High-frequency (e.g., 10 Hz) eddy covariance measurements are typically used to estimate fluxes at the land–atmosphere interface at timescales of 15–60 min. These multivariate data contain information about the interdependency at high frequency between the interacting variables such as wind, humidity, temperature, and CO 2⁠ . We use data at 10 Hz from an eddy covariance instrument located at 25 m above agricultural land in the Midwestern US, which offers an opportunity to move beyond the traditional spectral analyses to explore causal dependency among variables. In this study, we quantify the structure of inter-dependencies of interacting variables at high frequency represented by a directed acyclic graph (DAG). We compare DAGs to investigate changes in structural differences in causal interactions. We then apply a distance-based classification and -means clustering approach to identify the evolution of the causal structure represented by a DAG. Our method selects an unbiased number of clusters of similar structures and characterizes the similarities and differences between them. We explore a range of dynamic behavior using data from a clear sky day and during a solar eclipse in 2017. Our results show well-defined clusters of similar causal dependencies as the system evolves. Furthermore, our approach provides a methodological framework to understand how causal dependence in turbulence manifests in high-frequency data when represented through a DAG.

54 ENVIRONMENTAL SCIENCES↗

Precise Measurement of the Spin Parameter of the Stellar-Mass Black Hole M33 X-7

In prior work, Chandra and Gemini-North observations of the eclipsing X-ray binary M33 X-7 have yielded measurements of the mass of its black hole primary and the system's orbital inclination angle of unprecedented accuracy. Likewise, the distance to the binary is known to a few percent. In an analysis based on these precise results, 15 Chandra and XMM-Newton X-ray spectra, and our fully relativistic accretion disk model, we find that the dimensionless spin parameter of the black hole primary is a{sub *} = 0.77 {+-} 0.05. The quoted 1 {sigma} error includes all sources of observational uncertainty. Four Chandra spectra of the highest quality, which were obtained over a span of several years, all lead to the same estimate of spin to within statistical errors (2%), and this estimate is confirmed by 11 spectra of lower quality. There are two remaining uncertainties: (1) the validity of the relativistic model used to analyze the observations, which is being addressed in ongoing theoretical work; and (2) our assumption that the black hole spin is approximately aligned with the angular momentum vector of the binary, which can be addressed by a future X-ray polarimetry mission.

79 ASTRONOMY AND ASTROPHYSICS↗

LONG-TERM PHOTOMETRIC ANALYSIS OF THE ACTIVE W UMa-TYPE SYSTEM TU BOOTIS

We present multicolor light curves for the W UMa-type eclipsing binary TU Boo for two epochs separated by 22 years. An analysis of the O - C diagram indicates the earlier observations took place right in the middle of a major period change, thus allowing for a unique study on mass transfer and period changes in this W UMa-type system. We compute model fits to our light curves, along with the only other published set, using the Wilson-Devinney program, and find temporally correlated changes in the size of the secondary component with anomalies in the O - C diagram. We investigate the cause of these changes and find support for the existence of rapid, large-scale mass transfer between the components. We postulate that this interaction allows them to maintain nearly equal surface temperatures despite having achieved only marginal contact. We also find support for the evolutionary scenario in which TU Boo has undergone a mass ratio reversal in the past, due to large-scale mass transfer so that what is presently the secondary component of TU Boo is in an advanced evolutionary state, oversized due to a helium-enriched core, with a total system age of {>=}10 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

RADIAL VELOCITY STUDIES OF CLOSE BINARY STARS. XIV

Radial velocity (RV) measurements and sine curve fits to the orbital RV variations are presented for 10 close binary systems: TZ Boo, VW Boo, EL Boo, VZ CVn, GK Cep, RW Com, V2610 Oph, V1387 Ori, AU Ser, and FT UMa. Our spectroscopy revealed two quadruple systems, TZ Boo and V2610 Oph, while three stars showing small photometric amplitudes, EL Boo, V1387 Ori, and FT UMa, were found to be triple systems. GK Cep is a close binary with a faint third component. While most of the studied eclipsing systems are contact binaries, VZ CVn and GK Cep are detached or semidetached double-lined binaries, and EL Boo, V1387 Ori, and FT UMa are close binaries of uncertain binary type. The large fraction of triple and quadruple systems found in this sample supports the hypothesis of formation of close binaries in multiple stellar systems; it also demonstrates that low photometric amplitude binaries are a fertile ground for further discoveries of multiple systems.

79 ASTRONOMY AND ASTROPHYSICS↗

WIYN OPEN CLUSTER STUDY. XXXVI. SPECTROSCOPIC BINARY ORBITS IN NGC 188

We present 98 spectroscopic binary orbits resulting from our ongoing radial velocity survey of the old (7 Gyr) open cluster NGC 188. All but 13 are high-probability cluster members based on both radial velocity and proper motion membership analyses. Fifteen of these member binaries are double lined. Our stellar sample spans a magnitude range of 10.8 {<=}V{<=} 16.5 (1.14-0.92 M {sub sun}) and extends spatially to 17 pc ({approx}13 core radii). All of our binary orbits have periods ranging from a few days to on the order of 10{sup 3} days, and thus are hard binaries that dynamically power the cluster. For each binary, we present the orbital solutions and place constraints on the component masses. Additionally, we discuss a few binaries of note from our sample, identifying a likely blue straggler-blue straggler binary system (7782), a double-lined binary with a secondary star which is underluminous for its mass (5080), two potential eclipsing binaries (4705 and 5762), and two binaries which are likely members of a quadruple system (5015a and 5015b)

79 ASTRONOMY AND ASTROPHYSICS↗