Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode separator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Study program of NASA/GSFC weld quality monitor system

The Weld Quality Monitor has provided online control through the application of linear transducers. The electronic systems must be upgraded to increase confidence level required in production. The Weld Quality Monitor has been used with a recent model solid state power supply to evaluate ability to differentiate between sound and defective weld joints. The Weld Quality Monitor has been evaluated on Dumet and Kovar to interconnect materials Nickel and Alloy 180 in weld joints used on microelectronic module fabrication. Distinct separation was achieved between low strength welds and sound welds by the Quality Monitor. Evaluation performed indicates a drift level at less than 2 percent on a series of 50 consecutive welds. Operation under shop conditions identified need for controlled electrode impact. This was achieved with pneumatic actuation.

Hutchinson, W. R.↗

Multi-Pass Quadrupole Mass Analyzer

Analysis of the composition of planetary atmospheres is one of the most important and fundamental measurements in planetary robotic exploration. Quadrupole mass analyzers (QMAs) are the primary tool used to execute these investigations, but reductions in size of these instruments has sacrificed mass resolving power so that the best present-day QMA devices are still large, expensive, and do not deliver performance of laboratory instruments. An ultra-high-resolution QMA was developed to resolve N2 +/CO+ by trapping ions in a linear trap quadrupole filter. Because N2 and CO are resolved, gas chromatography columns used to separate species before analysis are eliminated, greatly simplifying gas analysis instrumentation. For highest performance, the ion trap mode is used. High-resolution (or narrow-band) mass selection is carried out in the central region, but near the DC electrodes at each end, RF/DC field settings are adjusted to allow broadband ion passage. This is to prevent ion loss during ion reflection at each end. Ions are created inside the trap so that low-energy particles are selected by low-voltage settings on the end electrodes. This is beneficial to good mass resolution since low-energy particles traverse many cycles of the RF filtering fields. Through Monte Carlo simulations, it is shown that ions are reflected at each end many tens of times, each time being sent back through the central section of the quadrupole where ultrahigh mass filtering is carried out. An analyzer was produced with electrical length orders of magnitude longer than its physical length. Since the selector fields are sized as in conventional devices, the loss of sensitivity inherent in miniaturizing quadrupole instruments is avoided. The no-loss, multi-pass QMA architecture will improve mass resolution of planetary QMA instruments while reducing demands on the RF electronics for high-voltage/high-frequency production since ion transit time is no longer limited to a single pass. The QMA-based instrument will thus give way to substantial reductions of the mass of flight instruments.

Prestage, John D.↗

Li-Metal Anode in Dilute Electrolyte LiFSI/TMP: Electrochemical Stability Using Ab Initio Molecular Dynamics

Ab initio molecular dynamics simulations were performed for Li + conducting electrolytes based on trimethyl phosphates (TMP) and lithium bis(fluorosulfonyl)imide (Li + FSI – ) salt in contact with a Li-metal electrode. We focused on the transient-state behavior at the electrolyte, interfacial electrolyte–Li-metal electrode, and lithium reference electrode–electrolyte–Li-metal electrode to study dynamics and activation energy barriers of the Li + ion, electrochemical and thermal stability of the interface electrode-electrolyte, and potential behavior of the Li-metal electrode, respectively. Our results show that in the most stable state, Li + ions are tetrahedrally coordinated to three TMPs and one FSI – . The inner solvation shell of a Li-ion is composed of three TMP and one FSI – in one contact ion-pair and four TMPs in a solvent-separated ion-pair. On the other hand, Li-ions transport through electrolyte cages takes place when they are coordinated with three or less molecules that could be a combination of TMPs and FSI – . The decomposition pathway of the LiFSI salt when in direct contact with the Li-metal anode starts with defluorination of FSI – , rapidly losing F– to the lithium surface, forming LiF species. The remaining FSO 2 NSO 2 –2 with the addition of 2e – from the Li-metal decomposes into SO 2 –2 and NFSO 2 –2 . SO 2 –2 deposits on the Li-surface and decomposes into Li 2 O and Li 2 S. The remaining NFSO 2 –2 defluorinates, losing F – ion to the lithium surface, resulting in LiF and the remaining NSO 2 –1 deposits on the lithium surface and decomposes in the following picoseconds, forming several binary compounds such as Li 3 N, Li 2 S and Li 2 O. In contrast, when the salt is solvated by the TMP molecules, avoiding a direct contact with the Li metal electrode, only one defluorination occurs, decomposing the FSI – into FSO 2 NSO 2 –2 and a F – . The two anions remain stable as they are solvated by the TMP molecules. Furthermore, we also analyzed the open circuit potential energy (OCPE) of the Li-metal electrode during the SEI formation. OCPE is calculated from the average local potential profile difference within the Li-metal electrode and a pristine Li-crystal reference electrode (LRE). When no SEI is formed, the Li-metal electrode has an average OCPE of +0.36 eV vs LRE. Due to the formation of a SEI, the Li-metal electrode has an average OCPE between -0.07 and -0.21 eV vs LRE. The OCPE of the Li-metal electrode decreases by ~0.42 eV when a SEI is formed.

25 ENERGY STORAGE↗

Microstructure and dielectric properties of piezoelectric magnetron sputtered w-Sc{sub x}Al{sub 1-x}N thin films

Piezoelectric wurtzite Sc{sub x}Al{sub 1-x}N (x = 0, 0.1, 0.2, 0.3) thin films were epitaxially grown by reactive magnetron co-sputtering from elemental Sc and Al targets. Al{sub 2}O{sub 3}(0001) wafers with TiN(111) seed and electrode layers were used as substrates. X-ray diffraction shows that an increase in the Sc content results in the degradation of the crystalline quality. Samples grown at 400 deg. C possess true dielectric behavior with quite low dielectric losses and the leakage current is negligible. For ScAlN samples grown at 800 deg. C, the crystal structure is poor and leakage current is high. Transmission electron microscopy with energy dispersive x-ray spectroscopy mapping shows a mass separation into ScN-rich and AlN-rich domains for x {>=} 0.2 when substrate temperature is increased from 400 to 800 deg. C. The piezoelectric response of epitaxial Sc{sub x}Al{sub 1-x}N films measured by piezoresponse force microscopy and double beam interferometry shows up to 180% increase by the addition of Sc up to x = 0.2 independent of substrate temperature, in good agreement with previous theoretical predictions based on density-functional theory.

36 MATERIALS SCIENCE↗

HRTEM Imaging and Mechanistic Insights Into Carbon Nanotube Nucleation and Growth on Fe Nanocatalysts in a Thermal Plasma

Thermal plasma decomposition of natural gas is a scalable pathway for the production of hydrogen alongside high-value carbon nanotubes (CNTs). Metals evaporate from an electrode and condense to form seed nanoparticles that nucleate and grow CNTs. However, the lack of mechanistic understanding of the CNT nucleation and growth processes in thermal plasma makes control over CNT diameter, chirality, length, and yield difficult. We debundled and separated CNTs from soots produced using iron (Fe) nanocatalysts, and distributed them on monolayer graphene for high-resolution transmission electron microscopy (HRTEM) imaging to gain mechanistic insights. Full graphene encapsulation was found for relatively small Fe nanoparticles that were molten at high temperatures. Zigzag single-wall or double-wall CNTs (SWCNTs or DWCNTs) appeared to have grown out directly from the graphene covering on the conical or cylindrical bodies of small molten Fe nanodroplets with high curvature. Also, SWCNTs likely grew out from H- or O-atom etched single-wall carbon nanocones observed on conical Fe nanoparticles. A SWCNT/DWCNT could also be generated from the cracked opening of the graphene covering on a face-centered cubic (FCC) Fe nanoparticle. A simple, plausible pathway is proposed for the growth of an open, H-passivated, zigzag SWCNT involving reaction of CH 2 and CH radicals at high temperatures.

Fe nanocatalysts↗

Mitigating thermal runaway of lithium-ion battery through electrolyte displacement

Alkanes are investigated as thermal-runaway retardants (TRR) for lithium-ion battery (LIB). TRR is a chemical that can rapidly terminate exothermic reactions in LIB. Under normal working conditions, TRR is sealed in separate packages in the LIB cell, and upon mechanical abuse, it is released to suppress heat generation. The alkanes under investigation include octane, pentadecane, and icosane, among which pentadecane has the highest thermal-runaway mitigation (TRM) efficiency. In nail penetration test on coin cells, ∼4 wt. % pentadecane reduced the maximum temperature by ∼60%; in impact test on pouch cells, ∼5 wt. % pentadecane reduced the maximum temperature by ∼90%. The high TRM efficiency of pentadecane is attributed to its high wettability to separator and its immiscibility with electrolyte. By forming a physical barrier between the cathode and anode, pentadecane interrupts lithium ion (Li+) transport and increases the charge transfer resistance by nearly two orders of magnitude. The diffusion rate of pentadecane in the electrode layer stack was measured to be ∼580 μm/s.

Shi, Yang↗

Acoustooptic pulse-echo transducer system

A pulse-echo transducer system which uses an ultrasonic generating element and an optical detection technique is described. The transmitting transducer consists of a concentric ring electrode pattern deposited on a circular, X-cut quartz substrate with a circular hole in the center. The rings are independently pulsed with a sequence high voltage signals phased in such a way that the ultrasonic waves generated by the separate rings superimpose to produce a composite field which is focused at a controllable distance below the surface of the specimen. The amplitude of the field reflected from this focus position is determined by the local reflection coefficient of the medium at the effective focal point. By processing the signals received for a range of ultrasonic transducer array focal lengths, the system can be used to locate and size anomalies within solids and liquids. Applications in both nondestructive evaluation and biomedical scanning are suggested.

Claus, R. O.↗

Conductivity based on selective etch for GaN devices and applications thereof

This invention relates to methods of generating NP gallium nitride (GaN) across large areas (>1 cm.sup.2) with controlled pore diameters, pore density, and porosity. Also disclosed are methods of generating novel optoelectronic devices based on porous GaN. Additionally a layer transfer scheme to separate and create free-standing crystalline GaN thin layers is disclosed that enables a new device manufacturing paradigm involving substrate recycling. Other disclosed embodiments of this invention relate to fabrication of GaN based nanocrystals and the use of NP GaN electrodes for electrolysis, water splitting, or photosynthetic process applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiple-membrane multiple-electrolyte redox flow battery design

A redox flow battery is provided. The redox flow battery involves multiple-membrane (at least one cation exchange membrane and at least one anion exchange membrane), multiple-electrolyte (one electrolyte in contact with the negative electrode, one electrolyte in contact with the positive electrode, and at least one electrolyte disposed between the two membranes) as the basic characteristic, such as a double-membrane, triple electrolyte (DMTE) configuration or a triple-membrane, quadruple electrolyte (TMQE) configuration. The cation exchange membrane is used to separate the negative or positive electrolyte and the middle electrolyte, and the anion exchange membrane is used to separate the middle electrolyte and the positive or negative electrolyte.

25 ENERGY STORAGE↗

Conductivity based on selective etch for GaN devices and applications thereof

This invention relates to methods of generating NP gallium nitride (GaN) across large areas (>1 cm2) with controlled pore diameters, pore density, and porosity. Also disclosed are methods of generating novel optoelectronic devices based on porous GaN. Additionally a layer transfer scheme to separate and create free-standing crystalline GaN thin layers is disclosed that enables a new device manufacturing paradigm involving substrate recycling. Other disclosed embodiments of this invention relate to fabrication of GaN based nanocrystals and the use of NP GaN electrodes for electrolysis, water splitting, or photosynthetic process applications.

Zhang, Yu↗

Electrodeionization Using Microseparated Bipolar Membranes

An electrochemical technique for deionizing water, now under development, is intended to overcome a major limitation of prior electrically-based water-purification techniques. The limitation in question is caused by the desired decrease in the concentration of ions during purification: As the concentration of ions decreases, the electrical resistivity of the water increases, posing an electrical barrier to the removal of the remaining ions. In the present technique, this limitation is overcome by use of electrodes, a flowfield structure, and solid electrolytes configured to provide conductive paths for the removal of ions from the water to be deionized, even when the water has already been purified to a high degree. The technique involves the use of a bipolar membrane unit (BMU), which includes a cation-exchange membrane and an anion-exchange membrane separated by a nonconductive mesh that has been coated by an ionically conductive material (see figure). The mesh ensures the desired microseparation between the ion-exchange membranes: The interstices bounded by the inner surfaces of the membranes and the outer surfaces of the coated mesh constitute a flow-field structure that allows the water that one seeks to deionize (hereafter called "process water" for short) to flow through the BMU with a low pressure drop. The flow-field structure is such that the distance between any point in the flow field and an ionically conductive material is small; thus, the flow-field structure facilitates the diffusion of molecules and ions to and from the ion-exchange membranes. The BMU is placed between an anode and a cathode, but not in direct contact with these electrodes. Instead, the space between the anion-exchange membrane and the anode is denoted the anode compartment and is filled with an ionic solution. Similarly, the space between the cation-exchange membrane and the cathode is denoted the cathode compartment and is filled with a different ionic solution. The electrodes are made of titanium coated with platinum.

Lyons, Donald↗

A Dual–Phase Electrolyte for High–Energy Lithium–Sulfur Batteries

Dissolution of lithium polysulfides (LiPSs) is essential for fast cathode kinetics, but detrimental for anode stability, especially under lean electrolyte conditions. Here in this work, the phase separation phenomenon between solvents with different polarities (tetramethyl sulfone [TMS] and dibutyl ether [DBE]) is utilized to enable the design of a dual-phase electrolyte. High-polarity, high-density TMS–lithium bis(trifluoromethanesulfonyl)imide–ammonium trifluoroacetate as the cathode electrolyte strongly solvates LiPSs, which propel the sulfur redox reaction. Moreover, the composite of DBE and a polymeric ion conductor serves as the anode electrolyte. The addition of DBE in the anode side effectively prevents the crossover of corrosive species (LiPSs and ammonia trifluoroacetate), enabling a significant improvement in Li-metal anode stability. The electrode-specific dual-phase electrolyte design provides electrochemical performance superior to conventional electrolytes. Without additional electrode engineering, pouch cells assemble with the dual-phase electrolyte cycle under a lean electrolyte (4 µL mg –1 ) and low-Li-excess condition (N/P = 3) for 120 cycles.

25 ENERGY STORAGE↗

Oblique interactions of dust density waves

Self-excited dust density waves (DDWs) are studied in a striped electrode device. In addition to the usual perpendicularly (with respect to the electrode) propagating DDWs, which have been frequently observed in dusty plasma experiments on the ground, a low-frequency oblique mode is also observed. This low-frequency oblique DDW has a frequency much lower than the dust plasma frequency and its spontaneous excitation is observed even with a very low dust density. It is found that the low-frequency oblique mode can exist either separately or together with the usual perpendicular mode. In the latter case, a new mode arises as a result of the interactions between the perpendicular and the oblique modes. The experiments show that these three modes satisfy the wave coupling conditions in both the frequencies and the wave-vectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Oblique interactions of dust density waves

Self-excited dust density waves (DDWs) are studied in a striped electrode device. In addition to the usual perpendicularly (with respect to the electrode) propagating DDWs, which have been frequently observed in dusty plasma experiments on the ground, a low-frequency oblique mode is also observed. This low-frequency oblique DDW has a frequency much lower than the dust plasma frequency and its spontaneous excitation is observed even with a very low dust density. It is found that the low-frequency oblique mode can exist either separately or together with the usual perpendicular mode. In the latter case, a new mode arises as a result of the interactions between the perpendicular and the oblique modes. The experiments show that these three modes satisfy the wave coupling conditions in both the frequencies and the wave-vectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying electrochemical processes by distribution of relaxation times in proton exchange membrane electrolyzers

Distribution of relaxation time (DRT) is used to interpret electrochemical impedance spectroscopy (EIS) for proton exchange membrane (PEM) water electrolyzers, with an attempt to separate overlapped relaxation processes in Nyquist plots. By varying operating conditions and catalyst loadings, four main relaxation peaks arising from EIS can be identified and successfully separated from low to high frequencies as (P1) mass transport, (P2) oxygen evolution reaction kinetics, (P3) reaction kinetics (with faster time constant than P2), and (P4) ionic transport. Here, the shape, height, and frequency of the DRT peaks change with different membrane electrode assembly (MEA) configurations. Electron microscopy reveals distinct features from the cross-sectioned MEAs which verify critical DRT results in that increasing the iridium (Ir)-anode loading from 0.2 mgIr/cm 2 to 1.5 mgIr/cm 2 reduces kinetic losses due to higher site-access; a thick and compacted anode, however, also triggers higher ohmic resistances from membrane/catalyst layer hydration and increases transport losses due to longer ionomer pathways. DRT provides higher resolution to EIS for deconvoluting processes with different relaxation times and the quantification of DRT peaks improves the accounting of total losses from each process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow shaping using three-dimensional microscale gas discharge

We introduce a flow shaping mechanism using surface compliant microscale gas discharge. A three-dimensional finite element-based multiscale ionized gas flow code is utilized to analyze charge separation, potential distribution, and flow inducement mechanism. For the case of quiescent flow, a horseshoe-shaped plasma generator is introduced. Due to its unusual shape, the three-dimensional electric force excites a pinching effect on the fluid inside selectively powered electrode arc. Such effect is capable of tripping the flow-ejecting fluid normal to the plane of the actuator and thus can be very useful for many applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of LEO cycling on 125 Ah advanced design IPV nickel-hydrogen battery cells

An advanced 125 Ah individual pressure vessel (IPV) nickel-hydrogen cell was designed. The primary function of the advanced cell, is to store and deliver energy for long term, low earth-orbit (LEO) spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent potassium hydroxide (KOH) electrolyte, (2) use of a patented catalyzed wall wick, (3) use of serrated edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management, and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion. Six 125 Ah flight cells based on this design were fabricated by Eagle-Picher. Three of the cells contain all of the advanced features (test cells) and three are the same as the test cells except they don't have catalyst on the wall wick (control cells). All six cells are in the process of being evaluated in a LEO cycle life test. The cells have accumulated about 4700 LEO cycles (60 percent DOD 10 C). There have been no cell failures, the catalyzed wall wick cells however, are performing better.

Smithrick, John J.↗

Effect of LEO cycling on 125 Ah advanced design IPV nickel-hydrogen battery cells

An advanced 125 Ah individual pressure vessel (IPV) nickel-hydrogen cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term, low earth-orbit (LEO) spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent potassium hydroxide (KOH) electrolyte, (2) use of a patented catalyzed wall wick, (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management, and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion. Six 125-Ah flight cells based on this design were fabricated by Eagle-Picher. Three of the cells contain all of the advanced features (test cells) and three are the same as the test cells except they don't have catalyst on the wall wick (control cells). All six cells are in the process of being evaluated in a LEO cycle life test. The cells have accumulated about 4700 LEO cycles (60 percent DOD 10 C). There have been no cell failures; the catalyzed wall wick cells, however, are performing better.

Smithrick, John J.↗