Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

JSPEC – An Open Source Program for IBS and Electron Cooling Simulation

The intrabeam scattering can affect the accumulation, the lifetime, and the property of a high-intensity beam. Electron cooling is a method to mitigate the intrabeam scattering effect. JSPEC (JLab Simulation Package on Electron Cooling) is an open-source program developed at Jefferson Lab, which includes various numerical models and friction force formulas for intrabeam scattering and electron cooling simulations. JSPEC has been benchmarked with BETACOOL and experimental data. In this report, we will introduce what features JSPEC provides to the users and how it carries out the computations. Numerical examples are presented to demonstrate the performance and the validity of JSPEC.

Zhang, He↗

3D modeling of the electron energy distribution function in negative hydrogen ion sources

For optimization and accurate prediction of the amount of H-ion production in negative ion sources, analysis of electron energy distribution function (EEDF) is necessary. We are developing a numerical code which analyzes EEDF in the tandem-type arc-discharge source. It is a three-dimensional Monte Carlo simulation code with realistic geometry and magnetic configuration. Coulomb collision between electrons is treated with the ''binary collision'' model and collisions with hydrogen species are treated with the ''null-collision'' method. We applied this code to the analysis of the JAEA 10 A negative ion source. The numerical result shows that the obtained EEDF is in good agreement with experimental results.

43 PARTICLE ACCELERATORS↗

Various Applications of Precision Low-Energy Nuclear Electron Spectrometry in the KATRIN Tritium Neutrino Project

The energy scale of the main spectrometer in the KATRIN tritium project is required to remain stable within ±60 meV at an electron energy of 18.6 keV for two months in order to reach the intended sensitivity of 0.2 eV for the rest mass of the electron antineutrino. A natural source of reference electrons with an energy of 17824.3 ± 0.5 eV based on K -conversion electrons of the 32-keV nuclear γ-transition in {sup 83m}Kr from the decay of parent {sup 83}Rb was developed for this purpose using precision low-energy nuclear electron spectrometry. The spectroscopic parameters of {sup 83m}Kr/{sup 83}Rb sources fabricated by ion implantation into polycrystalline platinum foils were significantly better than the parameters of vacuum-deposited sources. A large-scale study of the influence of the physicochemical environment of atoms of different radioisotopes in various matrices of vacuum-deposited and implanted radioactive sources on the energy of emitted conversion and Auger electrons and on the structure of the corresponding energy spectra was conducted in the process. The possibility of application of photoelectron sources with a metallic converter as sources of reference electrons for the KATRIN project was also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Bunch Compression for a Compact Compton Source

A compact electron accelerator suitable for Compton source applications is in design at the Center for Accelerator Science at Old Dominion University and Jefferson Lab. Here we discuss two options for transverse magnetic bunch compression and final focus, each involving a 4-dipole chicane with M_{56} tunable over a range of 1.5-2.0m with independent tuning of final focus to interaction point $\beta$*=5mm. One design has no net bending, while the other has net bending of 90 degrees and is suitable for compact corner placement.

43 PARTICLE ACCELERATORS↗

RF-driven Proton Source with a Back-streaming Electron Dump

This article describes an RF ion source with a back-streaming electron dump. A quartz tube, brazed to a metal plug at one end, is fused in the center of a flat quartz plate. RF power (at 13.6 MHz) is coupled to generate hydrogen plasma using a planar external antenna bonded to the window. Bonding the water-cooled rf antenna to the quartz window significantly lowers its temperature. The water-cooled metal plug serves as the backstreaming electron dump. At 1800W, the current density of extracted hydrogen ions reaches approximately 125 mA/cm{sup 2}.

43 PARTICLE ACCELERATORS↗

The influence of the extraction voltage on the energetic electron population of an electron cyclotron resonance ion source plasma

An influence of the extraction voltage on the high energy slope of bremsstrahlung radiation spectra has been reported in ECRIS experiments, which is not well understood so far. In order to provide more detailed data on this effect, we have measured bremsstrahlung radiation spectra accompanying especially the evolution of highly charge ions (i.e., by monitoring the Ar{sup 14+} charge state) as the extraction voltage is changed from 0 to 20 kV, in dedicated experiments at the Frankfurt 14 GHz-ECRIS.

43 PARTICLE ACCELERATORS↗

Microscopic Origin of Polarization Charges at Ga N / ( Al , Ga ) N Interfaces

Ga⁢N/(Al,Ga)⁢N heterojunctions are at the heart of high-electron-mobility transistors that are being adopted for high-power and high-frequency applications. The strong polarization fields present at this interface significantly enhance the density of the two-dimensional electron gas (2DEG) that is confined on the Ga⁢ N side of the junction. The microscopic origin of these electrons has been debated over the years: after excluding that they would be contributed by bulk donors, a model that identifies surface states on the (Al, Ga)⁢N surface as the source of electrons has become widely adopted. Recently, it has become clear, however, that the measured density of surface states is insufficient to account for the high electron density in the 2DEG. Here we demonstrate, based on state-of-the-art first-principles calculations, that the source of electrons is intrinsic to the overall structure and that the negative charge in the 2DEG is balanced by fixed charge on the surface. We perform a rigorous study of polarization, using our recently developed methodology for quantifying polarization fields within the finite-sized systems that can be addressed with density-functional calculations. The results show that the electrons that appear in the 2DEG originate locally at the interface, and that the net charge at the interface is predominantly compensated by fixed charge on the surface, rather than surface states. We elucidate the source of this fixed charge and associate it with surface reconstructions or the presence of heterovalent impurities (such as oxygen). Our results force a reassessment of the impact of surface states on the density of the 2DEG: rather than serving as a supply of electrons, the surface states mainly act to pin the Fermi level. Our conclusions allow a fresh interpretation of experimental observations and allow devising guidelines for optimizing carrier densities in the 2DEG.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron density measurement of cesium seeded negative ion source by surface wave probe

Electron density measurements of a large-scaled negative ion source were carried out with a surface wave probe. By comparison of the electron densities determined with the surface wave probe and a Langmuir probe, it was confirmed that the surface wave probe is highly available for diagnostic of the electron density in H{sup -} ion sources. In addition, it was found that the ratio of the electron density to the H{sup -} ion density dramatically decreases with increase of a bias voltage and the H{sup -} ions become dominant negative particles at the bias voltage of more than 6 V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Laser Frequency Transverse Modulation Might Compensate for the Spectral Broadening Due to Large Electron Energy Spread in Thomson Sources

Compact laser plasma accelerators generate high-energy electron beams with increasing quality. When used in inverse Compton backscattering, however, the relatively large electron energy spread jeopardizes potential applications requiring small bandwidths. We present here a novel interaction scheme that allows us to compensate for the negative effects of the electron energy spread on the spectrum, by introducing a transverse spatial frequency modulation in the laser pulse. Such a laser chirp, together with a properly dispersed electron beam, can substantially reduce the broadening of the Compton bandwidth due to the electron energy spread. We show theoretical analysis and numerical simulations for hard X-ray Thomson sources based on laser plasma accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radial characterization of the electron energy distribution in a helicon source terminated by a double layer

Electron energy probability functions (EEPFs) are measured across the radius (0{<=}r<6.85 cm) of a low pressure (0.3 mTorr) helicon plasma source terminated by a current-free double layer. The source field of about 130 G is generated using a Helmholtz coil pair and the radio frequency (rf) power is maintained at 250 W. All EEPFs exhibit a distribution with a temperature T{sub ebulk} out to a break energy {epsilon}{sub break} and a relatively depleted distribution for higher energies with a lower temperature T{sub etail}. T{sub ebulk} and T{sub etail} are about 8 eV and 5 eV, respectively, for r<4 cm and increase up to about 14 eV and 9 eV near the source wall, i.e., near the rf antenna. {epsilon}{sub break} is found to correspond to the potential drop of the double layer for the central part of the source and to the sheath potential near the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Tools For Oilfield Logging-While-Drilling Applications

Schlumberger is an international oilfield service company with nearly 80,000 employees of 140 nationalities, operating globally in 80 countries. As a market leader in oilfield services, Schlumberger has developed a suite of technologies to assess the downhole environment, including, among others, electromagnetic, seismic, chemical, and nuclear measurements. In the past 10 years there has been a radical shift in the oilfield service industry from traditional wireline measurements to logging-while-drilling (LWD) analysis. For LWD measurements, the analysis is performed and the instruments are operated while the borehole is being drilled. The high temperature, high shock, and extreme vibration environment of LWD imposes stringent requirements for the devices used in these applications. This has a significant impact on the design of the components and subcomponents of a downhole tool. Another significant change in the past few years for nuclear-based oilwell logging tools is the desire to replace the sealed radioisotope sources with active, electronic ones. These active radiation sources provide great benefits compared to the isotopic sources, ranging from handling and safety to nonproliferation and well contamination issues. The challenge is to develop electronic generators that have a high degree of reliability for the entire lifetime of a downhole tool. LWD tool testing and operations are highlighted with particular emphasis on electronic radiation sources and nuclear detectors for the downhole environment.

07 ISOTOPE AND RADIATION SOURCES↗

Cosmic ray electrons and positrons from discrete stochastic sources

The distances that galactic cosmic ray electrons and positrons can travel are severely limited by energy losses to at most a few kiloparsec, thereby rendering the local spectrum very sensitive to the exact distribution of sources in our galactic neighbourhood. However, due to our ignorance of the exact source distribution, we can only predict the spectrum stochastically. We argue that even in the case of a large number of sources the central limit theorem is not applicable, but that the standard deviation for the flux from a random source is divergent due to a long power law tail of the probability density. Instead, we compute the expectation value and characterise the scatter around it by quantiles of the probability density using a generalised central limit theorem in a fully analytical way. The uncertainty band is asymmetric about the expectation value and can become quite large for TeV energies. In particular, the predicted local spectrum is marginally consistent with the measurements by Fermi-LAT and HESS even without imposing spectral breaks or cut-offs at source. We conclude that this uncertainty has to be properly accounted for when predicting electron fluxes above a few hundred GeV from astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗

High electronegativity multi-dipolar electron cyclotron resonance plasma source for etching by negative ions

A large area plasma source based on 12 multi-dipolar ECR plasma cells arranged in a 3 x 4 matrix configuration was built and optimized for silicon etching by negative ions. The density ratio of negative ions to electrons has exceeded 300 in Ar/SF{sub 6} gas mixture when a magnetic filter was used to reduce the electron temperature to about 1.2 eV. Mass spectrometry and electrostatic probe were used for plasma diagnostics. The new source is free of density jumps and instabilities and shows a very good stability for plasma potential, and the dominant negative ion species is F{sup -}. The magnetic field in plasma volume is negligible and there is no contamination by filaments. The etching rate by negative ions measured in Ar/SF{sub 6}/O{sub 2} mixtures was almost similar with that by positive ions reaching 700 nm/min.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of 3-panel and 4-panel microscale ionization sources

Two designs of a microscale electron ionization (EI) source are analyzed herein: a 3-panel design and a 4-panel design. Devices were fabricated using microelectromechanical systems technology. Field emission from carbon nanotube provided the electrons for the EI source. Ion currents were measured for helium, nitrogen, and xenon at pressures ranging from 10{sup -4} to 0.1 Torr. A comparison of the performance of both designs is presented. The 4-panel microion source showed a 10x improvement in performance compared to the 3-panel device. An analysis of the various factors affecting the performance of the microion sources is also presented. SIMION, an electron and ion optics software, was coupled with experimental measurements to analyze the ion current results. The electron current contributing to ionization and the ion collection efficiency are believed to be the primary factors responsible for the higher efficiency of the 4-panel microion source. Other improvements in device design that could lead to higher ion source efficiency in the future are also discussed. These microscale ion sources are expected to find application as stand alone ion sources as well as in miniature mass spectrometers.

07 ISOTOPE AND RADIATION SOURCES↗

A discharge with a magnetic X-point as a negative hydrogen ion source

The study presents first results from investigations of a novel low-pressure plasma source, intended for a negative hydrogen ion production. The source utilizes a dc magnetic field, shaped to form a cusp with a magnetic null-point (X-point). Beside the common role of filtering out the high energy electrons, this magnetic field configuration ensures in the present case also an interesting mechanism of coupling the RF power to the plasma. Investigations performed using radio frequency modulation spectroscopy (RFMOS) reveal that the main power coupling to the electrons is confined in the region on one side of the X-point. The modulation of the light intensity indicates also the presence of a strong dc drift close to the plane of the X-point. Several hypothesises for its explanation are raised: an azimuthal diamagnetic drift due to strong axial gradients of the electron energy, the excitation of a standing helicon wave, which couples to the radial magnetic field in the plane of the X-point, or a Trivelpiece-Gould wave which is resonantly absorbed near the plane of the X-point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short time ion pulse extraction from the Dresden electron beam ion trap

We present measurements of the extraction of short time pulses of highly charged ions (4 keV, Ar{sup 16+}) from the Dresden electron beam ion trap. Thereby the dependence of the extractable ionic charge on the extraction regime was investigated. The ion extraction time was varied between 20 ns and 1 {mu}s. Furthermore the production of carbon ions and the influence of the extraction regime on the pulse widths was investigated to obtain information about the suitability of the Dresden EBIS-A in synchrotron based particle therapy facilities.

43 PARTICLE ACCELERATORS↗

Electron beam simulation from gun to collector: Towards a complete solution

An electron-beam simulation technique for high-resolution complete EBIS/T modelling is presented. The technique was benchmarked on the high compression HEC{sup 2} test-stand with an electron beam current, current density and energy of 10 A, 10 kA/cm{sup 2} and 49.2 keV, and on the immersed electron beam at REXEBIS for electron beam characteristics of 0.4 A, 200 A/cm{sup 2} and 4.5 keV. In both Brillouin-like and immersed beams the electron-beam radius varies from several millimeters at the gun, through some hundreds of micrometers in the ionization region to a few centimeters at the collector over a total length of several meters. We report on our approach for finding optimal meshing parameters, based on the local beam properties such as magnetic field-strength, electron energy and beam radius. This approach combined with dividing the problem domain into sub-domains, and subsequent splicing of the local solutions allowed us to simulate the beam propagation in EBISes from the gun to the collector using a conventional PC in about 24–36 h. Brillouin-like electron beams propagated through the complete EBIS were used to analyze the beam behavior within the collector region. We checked whether elastically reflected paraxial electrons from a Brillouin-like beam will escape from the collector region and add to the loss current. We have also studied the power deposition profiles as function of applied potentials using two electrode geometries for a Brillouin-like beam including the effects of backscattered electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An EBIS system for rare isotope science project in Korea

An EBIS system has been designed to be used as a charge breeder for the post accelerator of an ISOL system. An electron gun, which is designed to produce a maximum current of 3 A at the beam energy of 20 kV, will be acquired from the Budker Institute, Novosibirsk. Electron beam optics calculations of the EBIS system as well as of the gun assembly have been performed using PBGUNS and TRAK. A superconducting solenoid with a maximum field of 6 T is to be used to compress the electron beam. A test stand, which includes the gun assembly and a high-power electron beam collector, is being designed and will be ready for the gun test in the end of this year. Charge breeding simulation using EBIS0D and CBSIM has been performed for a few key isotopes.

43 PARTICLE ACCELERATORS↗