Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Cross-Laminated Timber Workshop: Pathways and Priorities for Cross-Laminated Timber Building Systems

A virtual workshop titled "BTO Cross-Laminated Timber Workshop: Pathways and Priorities for CLT Building Systems," was held on April 19, 2021, to identify research and development pathways, including the embodied energy content, operational energy efficiency, wall moisture profiles, structural connector durability, and health monitoring systems for CLT wall systems. In the workshop, perspectives were gathered from a wide range of stakeholders across North America from academia, the mass timber industry, trade groups, and federal government departments. The participants had knowledge in one or more areas of CLT building performance, production and construction, supply and demand dynamics of CLT panels, building codes, and recycling of CLT panels. To capture potential research opportunities from the participants in the mass timber field, the workshop was structured with the following objectives: 1. Identify the research and development opportunities to overcome technology gaps, integration issues, and market adoption challenges that are currently preventing the greater deployment of CLT, and 2. Understand what priorities and pathways are needed to advance energy efficient, high- rise CLT building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

“SLIMPLECTIC” INTEGRATORS: VARIATIONAL INTEGRATORS FOR GENERAL NONCONSERVATIVE SYSTEMS

Symplectic integrators are widely used for long-term integration of conservative astrophysical problems due to their ability to preserve the constants of motion; however, they cannot in general be applied in the presence of nonconservative interactions. In this Letter, we develop the “slimplectic” integrator, a new type of numerical integrator that shares many of the benefits of traditional symplectic integrators yet is applicable to general nonconservative systems. We utilize a fixed-time-step variational integrator formalism applied to the principle of stationary nonconservative action developed in Galley et al. As a result, the generalized momenta and energy (Noether current) evolutions are well-tracked. We discuss several example systems, including damped harmonic oscillators, Poynting–Robertson drag, and gravitational radiation reaction, by utilizing our new publicly available code to demonstrate the slimplectic integrator algorithm. Slimplectic integrators are well-suited for integrations of systems where nonconservative effects play an important role in the long-term dynamical evolution. As such they are particularly appropriate for cosmological or celestial N-body dynamics problems where nonconservative interactions, e.g., gas interactions or dissipative tides, can play an important role.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvements to CTF Code Verification and Unit Testing (FY2020)

In 2010, the U.S. Department of Energy created its first Energy Innovation Hub, which focuses on improving Light Water Reactors (LWRs) through Modeling and Simulation. This hub, named the Consortium for the Advanced Simulation of LWRs (CASL), attempts to characterize and understand LWR behavior under normal operating conditions and use any gained insights to improve their efficiency. In collaboration with North Carolina State University (NCSU), CASL has worked extensively on the thermal-hydraulic subchannel code Coolant Boiling in Rod Arrays—Three Field (COBRA-TF). The NCSU/CASL version of COBRA-TF has been rebranded as CTF. This document focuses on code verification test problems that ensure CTF converges to the correct answer for the intended application. The suite of code verification tests are mapped to the underlying conservation equations of CTF, and significant gaps are addressed. Convergence behavior and numerical errors are quantified for each of the tests. Tests that converge at the correct rate to the corresponding analytic solution are incorporated into the CTF automated regression suite. A new verification utility is created for this purpose, which enables code verification by generalizing the process. For problems that do not behave correctly, the results are reported but the problem is not included in the regression suite. In addition to verification studies, this document also quantifies the existing tests of constitutive models. A few existing gaps are addressed by adding new unit tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY20 Improvements to CTF Code Verification and Unit Testing

In 2010, the U.S. Department of Energy created its first Energy Innovation Hub, which focuses on improving Light Water Reactors (LWRs) through Modeling and Simulation. This hub, named the Consortium for the Advanced Simulation of LWRs (CASL), attempts to characterize and understand LWR behavior under normal operating conditions and use any gained insights to improve their efficiency. In collaboration with North Carolina State University (NCSU), CASL has worked extensively on the thermal-hydraulic subchannel code Coolant Boiling in Rod Arrays–Three Field (COBRA-TF). The NCSU/CASL version of COBRA-TF has been rebranded as CTF. This document focuses on code verification test problems that ensure CTF converges to the correct answer for the intended application. The suite of code verification tests are mapped to the underlying conservation equations of CTF, and significant gaps are addressed. Convergence behavior and numerical errors are quantified for each of the tests. Tests that converge at the correct rate to the corresponding analytic solution are incorporated into the CTF automated regression suite. A new verification utility is created for this purpose, which enables code verification by generalizing the process. For problems that do not behave correctly, the results are reported but the problem is not included in the regression suite. In addition to verification studies, this document also quantifies the existing tests of constitutive models. A few existing gaps are addressed by adding new unit tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data-driven model for cross ventilation potential in high-density cities based on coupled CFD simulation and machine learning

Effective urban ventilation through decent urban planning and building design can alleviate the deterioration of the urban built environment. Furthermore, natural ventilation requirements and guidelines in current building codes and standards are either qualitative or quantitative but subject to an absolute indoor airspeed threshold without considering the outdoor wind environment. To fill this gap, this paper develops an urban-scale coupled indoor and outdoor computational fluid dynamics (CFD) model and defines a novel ventilation index to assess natural ventilation potential. The index considers wind environments of both indoor and outdoor spaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Demonstration of the Brick Ontology to Scale up the Deployment of ASHRAE Guideline 36 Control Sequences

Many commercial buildings have a vast network of sensors as part of their building automation systems (BAS) that allows opportunities for energy consumption and cost savings by deploying advanced control sequences. However, this resource is often underutilized since BAS are typically programmed with simple control sequences with limited potential to deliver on these opportunities. The recent availability of ASHRAE Guideline 36 (G36) with advanced HVAC control sequences supports control retrofits in existing buildings to unlock much of the savings potential. However, barriers such as the lack of standard naming convention of building assets and data points, proprietary equipment and BAS, and the inherent uniqueness of buildings and their systems prevent building stakeholders from adopting any “plug-and-play” implementation of G36. Instead, control vendors must often undertake the manual and labor-intensive point mapping process to identify a data stream’s functional and spatial relationship within the HVAC system along with other relevant contexts and map it to the new control sequences. The vendor must carry out the point mapping process in each individual building since the mapping is unlikely to port over to another building. Even for the same building, the point mapping process can occur multiple times if various control vendors implement different control retrofits and/or multiple control retrofits happen over the lifecycle of the building. Then, there is the likelihood that G36 control sequences are programmed uniquely to the building, preventing the same implementation from being reused in another. Therefore, this paper presents a field demonstration of how we leveraged the Brick ontology with BACnet, OpenBuildingControl’s Control Description Language (CDL), and open-source support tools to implement scalable and portable advanced building controls. These tools provide standardized semantic descriptions and relationships of the building’s assets and data points (Brick), standardized communication protocol to read from and write to the building’s BAS (BACnet), and standardized code implementations (CDL) of standardized advanced control strategies (G36). We implemented G36’s hot water supply temperature setpoint reset in a Berkeley, CA building for this field demonstration. This field demonstration aims to show how integrating these tools may streamline the deployment of advanced control sequences such as G36 in a consistent manner regardless of differences found across buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variational integrators for reduced magnetohydrodynamics

Reduced magnetohydrodynamics is a simplified set of magnetohydrodynamics equations with applications to both fusion and astrophysical plasmas, possessing a noncanonical Hamiltonian structure and consequently a number of conserved functionals. We propose a new discretisation strategy for these equations based on a discrete variational principle applied to a formal Lagrangian. The resulting integrator preserves important quantities like the total energy, magnetic helicity and cross helicity exactly (up to machine precision). As the integrator is free of numerical resistivity, spurious reconnection along current sheets is absent in the ideal case. If effects of electron inertia are added, reconnection of magnetic field lines is allowed, although the resulting model still possesses a noncanonical Hamiltonian structure. After reviewing the conservation laws of the model equations, the adopted variational principle with the related conservation laws is described both at the continuous and discrete level. We verify the favourable properties of the variational integrator in particular with respect to the preservation of the invariants of the models under consideration and compare with results from the literature and those of a pseudo-spectral code.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Updraft Model for Development of Autonomous Soaring Uninhabited Air Vehicles

Large birds and glider pilots commonly use updrafts caused by convection in the lower atmosphere to extend flight duration, increase cross-country speed, improve range, or simply to conserve energy. Uninhabited air vehicles may also have the ability to exploit updrafts to improve performance. An updraft model was developed at NASA Dryden Flight Research Center (Edwards, California) to investigate the use of convective lift for uninhabited air vehicles in desert regions. Balloon and surface measurements obtained at the National Oceanic and Atmospheric Administration Surface Radiation station (Desert Rock, Nevada) enabled the model development. The data were used to create a statistical representation of the convective velocity scale, w*, and the convective mixing-layer thickness, zi. These parameters were then used to determine updraft size, vertical velocity profile, spacing, and maximum height. This paper gives a complete description of the updraft model and its derivation. Computer code for running the model is also given in conjunction with a check case for model verification.

Allen, Michael J.↗

ADVANCED INTEGRATION OF MULTI-SCALE MECHANICS AND WELDING PROCESS SIMULATION IN WELD INTEGRITY ASSESSMENT

The potential to save trillions of BTU’s in energy usage and billions of dollars in cost on an annual basis based on use of higher strength steel in major oil and gas transmission pipeline construction is a compelling opportunity recognized by both the US Department of Energy (DOE). The use of high-strength steels (X100) is expected to result in energy savings across the spectrum, from manufacturing the pipe to transportation and fabrication, including welding of line pipe. Elementary examples of energy savings include more the 25 trillion BTUs saved annually based on lower energy costs to produce the thinner-walled high-strength steel pipe, with the potential for the US part of the Alaskan pipeline alone saving more than 7 trillion BTU in production and much more in transportation and assembling. Annual production, maintenance and installation of just US domestic transmission pipeline is likely to save 5 to 10 times this amount based on current planned and anticipated expansions of oil and gas lines in North America. Among the most important conclusions from these studies were: • While computational weld models to predict residual stress and distortions are well-established and accurate, related microstructure models need improvement. • Fracture Initiation Transition Temperature (FITT) Master Curve properly predicts surface-cracked pipe brittle-to-ductile initiation temperature. It has value in developing Codes and Standards to better correlate full-scale behavior from either CTOD or Charpy test results with the proper temperature shifts from the FITT master curve method. • For stress-based flaw evaluation criteria, the new circumferentially cracked pipe limit-load solution in the 2007 API 1104 Appendix A approach is overly conservative by a factor of 4/π, which has additional implications. . • For strain-based design of girth weld defects, the hoop stress effect is the most significant parameter impacting CTOD-driving force and can increase the crack-driving force by a factor of 2 depending on strain-hardening, pressure level as a % of SMYS, and flaw size. • From years of experience in circumferential fracture analyses and experimentation, there has not been sufficient integration of work performed for other industries into analogous problems facing the oil and gas pipeline markets. Some very basic concepts and problems solved previously in these fields could have circumvented inconsistencies seen in the stress-based and strain-based analysis efforts. For example, in nuclear utility piping work, more detailed elastic-plastic fracture analyses were always validated in their ability to predict loads and displacements (stresses and strains). The eventual implementation of these methodologies will result in acceleration of the industry adoption of higher-strength line-pipe steels.

02 PETROLEUM↗

Static and Dynamic Frequency Scaling on Multicore CPUs

Dynamic voltage and frequency scaling (DVFS) adapts CPU power consumption by modifying a processor’s operating frequency (and the associated voltage). Typical approaches employing DVFS involve default strategies such as running at the lowest or the highest frequency, or observing the CPU’s runtime behavior and dynamically adapting the voltage/frequency configuration based on CPU usage. In this paper, we argue that many previous approaches suffer from inherent limitations, such as not account- ing for processor-specific impact of frequency changes on energy for different workload types. We first propose a lightweight runtime-based approach to automatically adapt the frequency based on the CPU workload, that is agnostic of the processor characteristics. We then show that further improvements can be achieved for affine kernels in the application, using a compile-time characterization instead of run-time monitoring to select the frequency and number of CPU cores to use. Our framework relies on a one-time energy characterization of CPU-specific DVFS profiles followed by a compile-time categorization of loop-based code segments in the application. These are combined to determine a priori of the frequency and the number of cores to use to execute the application so as to optimize energy or energy-delay product, outperforming runtime approach. Extensive evaluation on 60 benchmarks and five multi-core CPUs show that our approach systematically outperforms the powersave Linux governor, while improving overall performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lepton flavor asymmetries: from the early Universe to BBN

Large primordial lepton flavor asymmetries with almost vanishing total baryon-minus-lepton number can evade the usual BBN and CMB constraints if neutrino oscillations lead to perfect flavor equilibration. Solving the momentum averaged quantum kinetic equations (QKEs) describing neutrino oscillations and interactions, we perform the first systematic investigation of this scenario, uncovering a rich flavor structure in stark contradiction to the assumption of simple flavor equilibration. We find (i) a particular direction in flavor space, ∆ne ≃ – 2/3 (– 1)∆n μ for normal (inverted) neutrino mass hierarchy, in which the flavor equilibration is efficient and primordial asymmetries are essentially unconstrained, (ii) a minimal washout factor, ∆$n_{e}^{2}$| BBN ≤ 0.03 (0.016) ∑ α ∆$n_{α}^{2}$| ini yielding a conservative estimate for the allowed primordial asymmetries in a generic flavor direction, and (iii) particularly strong or weak washout if one of the initial flavor asymmetries vanishes due to non-adiabatic muon- or electron-driven MSW transitions. These results open up the possibility of a first-order QCD phase transition facilitated by large lepton asymmetries as well as baryogenesis from large and compensated ∆n e = ∆n μ asymmetries. Our systematic approach of deriving momentum averaged QKEs includes collision terms beyond the damping approximation, energy transfer between the neutrino and electron-photon plasma, and provides a fast and reliable way to investigate the impact of primordial lepton asymmetries at the time of BBN. We publicly release the Mathematica code COFLASY-M on https://github.com/mariofnavarro/COFLASY which solves the QKEs numerically.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Astrophysical Explosions Revisited: Collisionless Coupling of Debris to Magnetized Plasma

The coupling between a rapidly expanding cloud of ionized debris and an ambient magnetized plasma is revisited with a hybrid (kinetic ion/fluid electron) simulation code that allows a study over a wide range of plasma parameters. Over a specified range of hypothetical conditions, simple scaling laws in terms of the total debris mass and explosion speed are derived and verified for the maximal size of the debris cloud and the fraction of debris that free-streams from the burst along the magnetic field. Furthermore, the amount of debris that escapes from the burst with minimal coupling to the background magnetic field increases with the debris gyroradius. Test cases with two different debris species—including a heavy minority species with a relatively large gyroradius—highlight how the collisionless coupling of the debris depends on the single particle trajectories as well as the overall conservation of energy and momentum.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical properties of ideal three-dimensional Hall magnetohydrodynamics: The spectral structure of the equilibrium ensemble

The nonlinear dynamics of ideal, incompressible Hall magnetohydrodynamics (HMHD) is investigated through classical Gibbs ensemble methods applied to the finite Galerkin representation. The spectral structure of HMHD is derived in a three-dimensional periodic geometry and compared with the MHD case. This provides a general picture of spectral transfer and cascade by the assumption that ideal Galerkin HMHD follows equilibrium statistics as in the case of Euler [U. Frisch et al., J. Fluid Mech. 68, 769 (1975)] and MHD [T. Stribling and W. H. Matthaeus, Phys. Fluids B 2, 1979 (1990)] theories. In HMHD, the equilibrium ensemble is built on the conservation of three quadratic invariants: The total energy, the magnetic helicity, and the generalized helicity. The latter replaces the cross helicity in MHD. In HMHD equilibrium, several differences appear with respect to the MHD case: (i) The generalized helicity (and in a weaker way the energy and the magnetic helicity) tends to condense in the longest wavelength, as in MHD, but also admits the novel feature of spectral enhancement, not a true condensation, at the smallest scales; (ii) equipartition between kinetic and magnetic energy, typical of Alfvenic MHD turbulence, is broken; (iii) modal distributions of energy and helicities show minima due to the presence of the ion skin depth. Ensemble predictions are compared to numerical simulations with a low-order truncation Galerkin spectral code, and good agreement is seen. Implications for general turbulent states are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Evaluation of District Energy Microgrids Planning Tool for Non-Technical Users

Community Microgrids are increasingly gaining popularity worldwide for their efficiency, cost-effectiveness, and local resilience improvement. Microgrid planning tools play a crucial role in their deployment. In the process, tentative designs of the microgrid are simulated, analyzed, and optimized. Due to the complexity of the problem, planning tools must carefully balance computational efficiency while seeking the most optimal solutions. This paper investigates the impact of algorithm selection on CPU and memory utilization of a Community Microgrid planning tool that is specifically designed for non-technical users. We compare two version of the code with two alternatives for Community Microgrid planning tools: a Greedy Algorithm, and a Linear Programming Approach. This comparison examines scenarios spanning from 2 to 50 buildings. Our findings revealed a significant difference in performance between the two algorithms, underscoring the critical role of algorithm selection in optimizing the efficiency of Community Microgrid Planning Tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Energy Efficiency Design Guide for Tribal Lands

Homeowners and renters on tribal lands have historically faced a disproportionate energy burden compared to the United States as a whole. The Indian Health Service (IHS), which serves these communities, strives to meet aggressive energy performance goals when constructing their residential housing. Challenges common in rural locations can hinder progress toward those goals, such as availability of materials, access to specialized labor, and budget constraints. This guide is for architects and builders who aim to incorporate energy efficiency (EE) into their residential designs. This report presents commercially viable energy efficiency packages for a variety of locations and home inputs to help guide home builders in choosing improvements for energy performance. The intention is to provide a diverse set of packages that can be used during the design phase to achieve energy savings compared to a code minimum building design. By presenting a set of diverse options with similar expected energy savings and life-cycle costs, final decisions can be left up to the building designers who can better determine the appropriate package given local costs, materials, and labor availability. Although this guide was developed for IHS projects, it can be used to help designers and construction professionals better make cost-effective choices when a detailed, project-specific building energy analysis is not possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 4.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 4.1. The two most significant changes for HyRAM+ version 4.1 from HyRAM+ version 4.0 are direct incorporation of unconfined overpressure into the QRA calculations and modification of the models for cryogenic liquid flow through an orifice. In QRA mode, the user no longer needs to input peak overpressure and impulse values that were calculated separately; rather, the unconfined overpressure is estimated for the given system inputs, leak size, and occupant location. The orifice flow model now solves for the maximum mass flux through the orifice at constant entropy while conserving energy, which does not require a direct speed of sound calculation. This does not affect the mass flow for all-gaseous releases; the method results in the same speed of sound for choked flow. However, this method does result in a higher (and more realistic) mass flow rate for a given leak size for liquid releases than was previously calculated.

08 HYDROGEN↗

Coarse Grid Modeling of Turbine Film Cooling Flows Using Volumetric Source Terms

The recent trend in numerical modeling of turbine film cooling flows has been toward higher fidelity grids and more complex geometries. This trend has been enabled by the rapid increase in computing power available to researchers. However, the turbine design community requires fast turnaround time in its design computations, rendering these comprehensive simulations ineffective in the design cycle. The present study describes a methodology for implementing a volumetric source term distribution in a coarse grid calculation that can model the small-scale and three-dimensional effects present in turbine film cooling flows. This model could be implemented in turbine design codes or in multistage turbomachinery codes such as APNASA, where the computational grid size may be larger than the film hole size. Detailed computations of a single row of 35 deg round holes on a flat plate have been obtained for blowing ratios of 0.5, 0.8, and 1.0, and density ratios of 1.0 and 2.0 using a multiblock grid system to resolve the flows on both sides of the plate as well as inside the hole itself. These detailed flow fields were spatially averaged to generate a field of volumetric source terms for each conservative flow variable. Solutions were also obtained using three coarse grids having streamwise and spanwise grid spacings of 3d, 1d, and d/3. These coarse grid solutions used the integrated hole exit mass, momentum, energy, and turbulence quantities from the detailed solutions as volumetric source terms. It is shown that a uniform source term addition over a distance from the wall on the order of the hole diameter is able to predict adiabatic film effectiveness better than a near-wall source term model, while strictly enforcing correct values of integrated boundary layer quantities.

Heidmann, James D.↗