Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Provably accurate simulation of gauge theories and bosonic systems

Quantum many-body systems involving bosonic modes or gauge fields have infinite-dimensional local Hilbert spaces which must be truncated to perform simulations of real-time dynamics on classical or quantum computers. To analyze the truncation error, we develop methods for bounding the rate of growth of local quantum numbers such as the occupation number of a mode at a lattice site, or the electric field at a lattice link. Our approach applies to various models of bosons interacting with spins or fermions, and also to both abelian and non-abelian gauge theories. We show that if states in these models are truncated by imposing an upper limit Λ on each local quantum number, and if the initial state has low local quantum numbers, then an error at most ϵ can be achieved by choosing Λ to scale polylogarithmically with ϵ − 1 , an exponential improvement over previous bounds based on energy conservation. For the Hubbard-Holstein model, we numerically compute a bound on Λ that achieves accuracy ϵ , obtaining significantly improved estimates in various parameter regimes. We also establish a criterion for truncating the Hamiltonian with a provable guarantee on the accuracy of time evolution. Building on that result, we formulate quantum algorithms for dynamical simulation of lattice gauge theories and of models with bosonic modes; the gate complexity depends almost linearly on spacetime volume in the former case, and almost quadratically on time in the latter case. We establish a lower bound showing that there are systems involving bosons for which this quadratic scaling with time cannot be improved. By applying our result on the truncation error in time evolution, we also prove that spectrally isolated energy eigenstates can be approximated with accuracy ϵ by truncating local quantum numbers at Λ = polylog ( ϵ − 1 ) .

Tong, Yu↗

SU-E-J-151: Day-To-Day Variations in Fraction-Specific Motion Modeling Using Patient 4DCBCT Images

Purpose: The goal of this study is to quantify the interfraction reproducibility of patient-specific motion models derived from 4DCBCT acquired on the day of treatment of lung cancer stereotactic body radiotherapy (SBRT) patients. Methods: Motion models are derived from patient 4DCBCT images acquired daily over 3–5 fractions of treatment by 1) applying deformable image registration between each 4DCBCT image and a reference phase from that day, resulting in a set of displacement vector fields (DVFs), and 2) performing principal component analysis (PCA) on the DVFs to derive a motion model. The motion model from the first day of treatment is compared to motion models from each successive day of treatment to quantify variability in motion models generated from different days. Four SBRT patient datasets have been acquired thus far in this IRB approved study. Results: Fraction-specific motion models for each fraction and patient were derived and PCA eigenvectors and their associated eigenvalues are compared for each fraction. For the first patient dataset, the average root mean square error between the first two eigenvectors associated with the highest two eigenvalues, in four fractions was 0.1, while it was 0.25 between the last three PCA eigenvectors associated with the lowest three eigenvalues. It was found that the eigenvectors and eigenvalues of PCA motion models for each treatment fraction have variations and the first few eigenvectors are shown to be more stable across treatment fractions than others. Conclusion: Analysis of this dataset showed that the first two eigenvectors of the PCA patient-specific motion models derived from 4DCBCT were stable over the course of several treatment fractions. The third, fourth, and fifth eigenvectors had larger variations.

60 APPLIED LIFE SCIENCES↗

RECONSTRUCTING REDSHIFT DISTRIBUTIONS WITH CROSS-CORRELATIONS: TESTS AND AN OPTIMIZED RECIPE

Many of the cosmological tests to be performed by planned dark energy experiments will require extremely well-characterized photometric redshift measurements. Current estimates for cosmic shear are that the true mean redshift of the objects in each photo-z bin must be known to better than 0.002(1 + z), and the width of the bin must be known to {approx}0.003(1 + z) if errors in cosmological measurements are not to be degraded significantly. A conventional approach is to calibrate these photometric redshifts with large sets of spectroscopic redshifts. However, at the depths probed by Stage III surveys (such as DES), let alone Stage IV (LSST, JDEM, and Euclid), existing large redshift samples have all been highly (25%-60%) incomplete, with a strong dependence of success rate on both redshift and galaxy properties. A powerful alternative approach is to exploit the clustering of galaxies to perform photometric redshift calibrations. Measuring the two-point angular cross-correlation between objects in some photometric redshift bin and objects with known spectroscopic redshift, as a function of the spectroscopic z, allows the true redshift distribution of a photometric sample to be reconstructed in detail, even if it includes objects too faint for spectroscopy or if spectroscopic samples are highly incomplete. We test this technique using mock DEEP2 Galaxy Redshift survey light cones constructed from the Millennium Simulation semi-analytic galaxy catalogs. From this realistic test, which incorporates the effects of galaxy bias evolution and cosmic variance, we find that the true redshift distribution of a photometric sample can, in fact, be determined accurately with cross-correlation techniques. We also compare the empirical error in the reconstruction of redshift distributions to previous analytic predictions, finding that additional components must be included in error budgets to match the simulation results. This extra error contribution is small for surveys that sample large areas of sky (>{approx}10{sup 0}-100{sup 0}), but dominant for {approx}1 deg{sup 2} fields. We conclude by presenting a step-by-step, optimized recipe for reconstructing redshift distributions from cross-correlation information using standard correlation measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining Dark Energy Survey Science Verification data with near-infrared data from the ESO VISTA Hemisphere Survey

We present the combination of optical data from the Science Verification phase of the Dark Energy Survey (DES) with near-infrared (NIR) data from the European Southern Observatory VISTA Hemisphere Survey (VHS). The deep optical detections from DES are used to extract fluxes and associated errors from the shallower VHS data. Joint seven-band ( grizYJK ) photometric catalogues are produced in a single 3 sq-deg dedicated camera field centred at 02h26m-04d36m where the availability of ancillary multiwavelength photometry and spectroscopy allows us to test the data quality. Dual photometry increases the number of DES galaxies with measured VHS fluxes by a factor of ~4.5 relative to a simple catalogue level matching and results in a ~1.5 mag increase in the 80 per cent completeness limit of the NIR data. Almost 70 per cent of DES sources have useful NIR flux measurements in this initial catalogue. Photometric redshifts are estimated for a subset of galaxies with spectroscopic redshifts and initial results, although currently limited by small number statistics, indicate that the VHS data can help reduce the photometric redshift scatter at both z < 0.5 and z > 1. We present example DES+VHS colour selection criteria for high-redshift luminous red galaxies (LRGs) at z ~ 0.7 as well as luminous quasars. Using spectroscopic observations in this field we show that the additional VHS fluxes enable a cleaner selection of both populations with <10 per cent contamination from galactic stars in the case of spectroscopically confirmed quasars and <0.5 per cent contamination from galactic stars in the case of spectroscopically confirmed LRGs. The combined DES+VHS data set, which will eventually cover almost 5000 sq-deg, will therefore enable a range of new science and be ideally suited for target selection for future wide-field spectroscopic surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-E-BRE-07: Development of Dose Calculation Error Predictors for a Widely Implemented Clinical Algorithm

Purpose: Several shortcomings of the current implementation of the analytic anisotropic algorithm (AAA) may lead to dose calculation errors in highly modulated treatments delivered to highly heterogeneous geometries. Here we introduce a set of dosimetric error predictors that can be applied to a clinical treatment plan and patient geometry in order to identify high risk plans. Once a problematic plan is identified, the treatment can be recalculated with more accurate algorithm in order to better assess its viability. Methods: Here we focus on three distinct sources dosimetric error in the AAA algorithm. First, due to a combination of discrepancies in smallfield beam modeling as well as volume averaging effects, dose calculated through small MLC apertures can be underestimated, while that behind small MLC blocks can overestimated. Second, due the rectilinear scaling of the Monte Carlo generated pencil beam kernel, energy is not properly transported through heterogeneities near, but not impeding, the central axis of the beamlet. And third, AAA overestimates dose in regions very low density (< 0.2 g/cm{sup 3}). We have developed an algorithm to detect the location and magnitude of each scenario within the patient geometry, namely the field-size index (FSI), the heterogeneous scatter index (HSI), and the lowdensity index (LDI) respectively. Results: Error indices successfully identify deviations between AAA and Monte Carlo dose distributions in simple phantom geometries. Algorithms are currently implemented in the MATLAB computing environment and are able to run on a typical RapidArc head and neck geometry in less than an hour. Conclusion: Because these error indices successfully identify each type of error in contrived cases, with sufficient benchmarking, this method can be developed into a clinical tool that may be able to help estimate AAA dose calculation errors and when it might be advisable to use Monte Carlo calculations.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-16: Vulnerabilities in the Gamma Metric

Purpose: To explore vulnerabilities in the gamma index metric that undermine its wide use as a radiation therapy quality assurance tool. Methods: 2D test field pairs (images) are created specifically to achieve high gamma passing rates, but to also include gross errors by exploiting the distance-to-agreement and percent-passing components of the metric. The first set has no requirement of clinical practicality, but is intended to expose vulnerabilities. The second set exposes clinically realistic vulnerabilities. To circumvent limitations inherent to user-specific tuning of prediction algorithms to match measurements, digital test cases are manually constructed, thereby mimicking high-quality image prediction. Results: With a 3 mm distance-to-agreement metric, changing field size by ±6 mm results in a gamma passing rate over 99%. For a uniform field, a lattice of passing points spaced 5 mm apart results in a passing rate of 100%. Exploiting the percent-passing component, a 10×10 cm{sup 2} field can have a 95% passing rate when an 8 cm{sup 2}=2.8×2.8 cm{sup 2} highly out-of-tolerance (e.g. zero dose) square is missing from the comparison image. For clinically realistic vulnerabilities, an arc plan for which a 2D image is created can have a >95% passing rate solely due to agreement in the lateral spillage, with the failing 5% in the critical target region. A field with an integrated boost (e.g whole brain plus small metastases) could neglect the metastases entirely, yet still pass with a 95% threshold. All the failure modes described would be visually apparent on a gamma-map image. Conclusion: The %gamma<1 metric has significant vulnerabilities. High passing rates can obscure critical faults in hypothetical and delivered radiation doses. Great caution should be used with gamma as a QA metric; users should inspect the gamma-map. Visual analysis of gamma-maps may be impractical for cine acquisition.

60 APPLIED LIFE SCIENCES↗

Benchmarking machine learning strategies for phase-field problems

Abstract We present a comprehensive benchmarking framework for evaluating machine-learning approaches applied to phase-field problems. This framework focuses on four key analysis areas crucial for assessing the performance of such approaches in a systematic and structured way. Firstly, interpolation tasks are examined to identify trends in prediction accuracy and accumulation of error over simulation time. Secondly, extrapolation tasks are also evaluated according to the same metrics. Thirdly, the relationship between model performance and data requirements is investigated to understand the impact on predictions and robustness of these approaches. Finally, systematic errors are analyzed to identify specific events or inadvertent rare events triggering high errors. Quantitative metrics evaluating the local and global description of the microstructure evolution, along with other scalar metrics representative of phase-field problems, are used across these four analysis areas. This benchmarking framework provides a path to evaluate the effectiveness and limitations of machine-learning strategies applied to phase-field problems, ultimately facilitating their practical application.

36 MATERIALS SCIENCE↗

Dynamic Behavior of Natural Seep Vents: Analysis of Field and Laboratory Observations and Modeling (Final Scientific/Technical Report)

In this project, we have analyzed data collected by the U.S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) in a high pressure water tunnel (HPWT) and data from two research cruises to natural seeps in the Gulf of Mexico to adapt and validate a numerical model to predict the dynamics of natural seeps in the deep oceans. The HPWT data include video observations of the shrinkage rate of individual methane and natural gas bubbles under simulated deep-water conditions. Field data were collected during two cruises by the Gulf Integrated Spill Research (GISR) Consortium led by Texas A&M University and funded by the Gulf of Mexico Research Initiative (GoMRI). These data included in situ observations from a remotely operated vehicle (ROV) of gas bubbles at two natural seep sites in the Gulf and acoustic observations of the natural seep bubble flares in the ocean water column. The acoustic data were from multibeam echosounders, one mounted in a forward-looking orientation on the ROV and another mounted down-looking in the haul of the ship. All of these laboratory and field data were focused on the dynamics of natural gas bubbles at temperatures and pressures favorable for clathrate hydrate formation between the gas and water. Our analyses of this data focused on understanding the mechanisms responsible for gas bubble dissolution within the hydrate stability zone (HSZ) of the oceans. Ice-like hydrate shells may form on the bubble-water interface under these conditions, and it was unknown how this might affect the mass transfer of gas into the ocean. We were able to extract bubble shrinkage rates from the HPWT datasets. Using this data we determined that mass transfer coefficients with and without a hydrate shell match empirical values for bubbles in contaminated systems (so-called dirty bubbles contaminated by naturally occurring surfactants). We also showed that free gas, and not gas hydrate, is the dominant dissolving phase when the hydrate sub-cooling is below 11 degree Celsius (temperature difference between hydrate the hydrate formation temperature and ambient temperator) or the pressure is reducing as bubbles rise through the ocean water column. Using this mass transfer model, our numerical model of bubble dissolution matched the over 200 HPWT experiments with an average error of 10% for predicting the bubble size at the end of an experiment. From field data in the literature, we also observed that gas bubbles dissolve faster when they are initially released, following mass transfer coefficients for so-called clean-bubbles (those not yet contaminated by surfactants). Shortly after release within the HSZ, a hydrate shell forms on the bubble-water interface, and the mass transfer reduces to rates matching those of dirty bubbles. We correlated this transition time from clean to dirty bubble behavior with the initial bubble surface area and the hydrate sub-cooling. With this model for hydrate formation time and using the mass transfer coefficients deduced from the HPWT data, we validated our numerical model for predicting the rise heights of natural seep flares in the oceans. Flare heights are commonly observed in haul-mounted acoustic multibeam data. The numerical model predicts bubbles to rise high in the ocean water column owing to the slower mass transfer rates for dirty bubbles that accompany the majority of their rise time. We found that the numerical model predictions matched the observed flare heights within 5% to 10% accuracy when we compared the rise heights of the largest bubbles released from the seafloor with the bubbles acoustically visible in the multibeam data. Bubbles become acoustically transparent as they shrink to sizes of order 1 mm in diameter for the multibeam frequencies used in the field. The forward-looking multibeam on the ROV also provided data on the lateral spreading of bubbles in natural seep flares. Our analysis of this data showed that spreading follows a diffusion process, with the effective diffusivity correlating with the wobbling length scale of these ellipsoidal bubbles. When we apply this diffusivity in a random displacement model of bubble spreading, our numerical simulations match closely the lateral spread observed by the M3 in the ocean water column. Finally, we compared the seep model predictions for the acoustic properties of these natural seep plumes with that observed by the acoustic instruments in the field. The M3 and EM 302 observations were converted to relative values of target strength using a calibration we obtained in the laboratory for the M3 and using an algorithm from the manufacturer for the EM 302. Comparing the numerical seep model to these data, we obtain good agreement over the whole height of rise of these bubble flares. This further validates the numerical model. Overall, our validated seep model captures the key dynamics of gas bubbles released from natural seeps in the oceans and helps to predict the fate of methane in the water column.

03 NATURAL GAS↗

A simple finite element method for the Stokes equations

The goal of this paper is to introduce a simple finite element method to solve the Stokes equations. This method is in primal velocity-pressure formulation and is so simple such that both velocity and pressure are approximated by piecewise constant functions. Implementation issues as well as error analysis are investigated. A basis for a divergence free subspace of the velocity field is constructed so that the original saddle point problem can be reduced to a symmetric and positive definite system with much fewer unknowns. The numerical experiments indicate that the method is accurate.

97 MATHEMATICS AND COMPUTING↗

Automated design of an additive manufactured compact broadband antenna for plasma reflectometry

Broadband antennas operating in the gigahertz frequency range are regularly used for plasma reflectometry diagnostics. Due to a lack of space and unique diagnostic constraints, these antennas are often custom in design and frequency range. Recent advances in additive manufacturing of high temperature copper alloys allow for expanded freedom in design of these diagnostic antennas. In this work, a heuristic simulated annealing algorithm is used alongside 3-D finite element simulation to automate the design of a double ridged rectangular horn antenna for a reflectometry diagnostic on the DIII-D tokamak. Optimization of antenna performance given the design constraints results in a compact broadband (6-20+ GHz) antenna design. Measured transmission from the additively manufactured antenna matches simulation within reasonable error, and experimental plasma electron density profiles from the DIII-D high-field side scrape-off layer are shown.

Additive manufacturing↗

Rapid Adaptation of Chemical Named Entity Recognition Using Few-Shot Learning and LLM Distillation

Named entity recognition (NER) has been widely used in chemical text mining for the automatic identification and extraction of chemical entities. However, existing chemical NER systems primarily focus on scenarios with abundant training data, requiring significant human effort on annotations. This poses challenges for applications in the chemical field, such as catalysis, where many advancements have traditionally relied on trial-and-error investigations and incremental adjustment of variables. This hinders catalysis science and technology progress in addressing emerging energy and environmental crises. In this work, we propose a few-shot NER model that can quickly adapt to extract new types of chemical entities by using only a limited number of annotated examples. Our model employs a metric-learning approach to transfer entity similarity knowledge from high-resource chemical domains (with abundant annotations) to enable effective entity recognition in low-resource specialized domains (limited annotation). We validate the effectiveness of our model on a few-shot chemical NER benchmark built based on six existing chemical NER data sets. Experiments show that the proposed few-shot NER model can achieve reasonable performance with only 5 examples per entity type and shows consistent improvement as the number of examples increases. Furthermore, we demonstrate how the proposed model can be trained with large language model (LLM) annotated data, opening a new pathway for rapid adaptation of NER systems. Furthermore, our approach leverages the knowledge broadness of large language models for chemistry while distilling this knowledge into a lightweight model suitable for efficient and in-house use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generalization in quantum machine learning from few training data

Modern quantum machine learning (QML) methods involve variationally optimizing a parameterized quantum circuit on a training data set, and subsequently making predictions on a testing data set (i.e., generalizing). In this work, we provide a comprehensive study of generalization performance in QML after training on a limited number N of training data points. We show that the generalization error of a quantum machine learning model with T trainable gates scales at worst as $\sqrt{T/N}$. When only K$\ll$T gates have undergone substantial change in the optimization process, we prove that the generalization error improves to $\sqrt{K/N}$. Our results imply that the compiling of unitaries into a polynomial number of native gates, a crucial application for the quantum computing industry that typically uses exponential-size training data, can be sped up significantly. We also show that classification of quantum states across a phase transition with a quantum convolutional neural network requires only a very small training data set. Other potential applications include learning quantum error correcting codes or quantum dynamical simulation. Our work injects new hope into the field of QML, as good generalization is guaranteed from few training data.

97 MATHEMATICS AND COMPUTING↗

Effects of electron inertia in collisionless magnetic reconnection

We present a study of collisionless magnetic reconnection within the framework of full two-fluid MHD for a completely ionized hydrogen plasma, retaining the effects of the Hall current, electron pressure and electron inertia. We performed 2.5D simulations using a pseudo-spectral code with no dissipative effects. We check that the ideal invariants of the problem are conserved down to round-off errors. Our numerical results confirm that the change in the topology of the magnetic field lines is exclusively due to the presence of electron inertia. The computed reconnection rates remain a fair fraction of the Alfvén velocity, which therefore qualifies as fast reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE YOUNG SOLAR ANALOGS PROJECT. I. SPECTROSCOPIC AND PHOTOMETRIC METHODS AND MULTI-YEAR TIMESCALE SPECTROSCOPIC RESULTS

This is the first in a series of papers presenting methods and results from the Young Solar Analogs Project, which began in 2007. This project monitors both spectroscopically and photometrically a set of 31 young (300–1500 Myr) solar-type stars with the goal of gaining insight into the space environment of the Earth during the period when life first appeared. From our spectroscopic observations we derive the Mount Wilson S chromospheric activity index (S{sub MW}), and describe the method we use to transform our instrumental indices to S{sub MW} without the need for a color term. We introduce three photospheric indices based on strong absorption features in the blue-violet spectrum—the G-band, the Ca i resonance line, and the Hydrogen-γ line—with the expectation that these indices might prove to be useful in detecting variations in the surface temperatures of active solar-type stars. We also describe our photometric program, and in particular our “Superstar technique” for differential photometry which, instead of relying on a handful of comparison stars, uses the photon flux in the entire star field in the CCD image to derive the program star magnitude. This enables photometric errors on the order of 0.005–0.007 magnitude. We present time series plots of our spectroscopic data for all four indices, and carry out extensive statistical tests on those time series demonstrating the reality of variations on timescales of years in all four indices. We also statistically test for and discover correlations and anti-correlations between the four indices. We discuss the physical basis of those correlations. As it turns out, the “photospheric” indices appear to be most strongly affected by emission in the Paschen continuum. We thus anticipate that these indices may prove to be useful proxies for monitoring emission in the ultraviolet Balmer continuum. Future papers in this series will discuss variability of the program stars on medium (days–months) and short (minutes to hours) timescales.

79 ASTRONOMY AND ASTROPHYSICS↗

SPECTRAL POLARIZATION OF THE REDSHIFTED 21 cm ABSORPTION LINE TOWARD 3C 286

A reanalysis of the Stokes-parameter spectra obtained of the z = 0.692 21 cm absorption line toward 3C 286 shows that our original claimed detection of Zeeman splitting by a line-of-sight magnetic field, B{sub los} = 87 {mu}G, is incorrect. Because of an insidious software error, what we reported as Stokes V is actually Stokes U: the revised Stokes V spectrum indicates a 3{sigma} upper limit of B{sub los}< 17 {mu}G. The correct analysis reveals an absorption feature in fractional polarization that is offset in velocity from the Stokes I spectrum by -1.9 km s{sup -1}. The polarization position-angle spectrum shows a dip that is also significantly offset from the Stokes I feature, but at a velocity that differs slightly from the absorption feature in fractional polarization. We model the absorption feature with three velocity components against the core-jet structure of 3C 286. Our {chi}{sup 2} minimization fitting results in components with differing (1) ratios of H I column density to spin temperature, (2) velocity centroids, and (3) velocity dispersions. The change in polarization position angle with frequency implies incomplete coverage of the background jet source by the absorber. It also implies a spatial variation of the polarization position angle across the jet source, which is observed at frequencies higher than the 839.4 MHz absorption frequency. The multi-component structure of the gas is best understood in terms of components with spatial scales of {approx}100 pc comprised of hundreds of low-temperature (T {<=} 200 K) clouds with linear dimensions of <<100 pc. We conclude that previous attempts to model the foreground gas with a single uniform cloud are incorrect.

79 ASTRONOMY AND ASTROPHYSICS↗

Simultaneous and Constrained Calibration of Multiple Hyperspectral Images Through a New Generalized Empirical Line Model

The empirical line (EL) calibration method is commonly used for atmospheric correction of remotely sensed spectral images and recovery of surface reflectance. The current EL-based methods are applicable to calibrate only single images. Therefore, the use of the EL calibration is impractical for imaging campaigns, where many (partially overlapped) images are acquired to cover a large area. In addition, the EL results are unconstrained and an undesired reflectance with negative values or larger than 100% can be obtained. In this paper, we use the standard EL model to formulate a new generalized empirical line (GEL) model. Based on the GEL, we present a novel method for simultaneous and constrained calibration of multiple images. This new method allows for calibration through multiple image constrained empirical line (MIcEL) and three additional calibration modes. Given a set of images, we use the available ground targets and automatically extracted tie points between overlapping images to calibrate all the images in the set simultaneously. Quantitative and visual assessments of the proposed method were carried out relatively to the off-the-shelf method quick atmospheric correction (QUAC), using real hyperspectral images and field measurements. The results clearly show the superiority of MIcEL with respect to the minimization of the difference between the reflectance values of the same object in different overlapping images. An assessment of the absolute accuracy, with respect to 11 field measurement points, shows that the accuracy of MIcEL, with an average mean absolute error (MAE) of ~11%, is comparable with respect to the QUAC.

47 OTHER INSTRUMENTATION↗

Beam’s-eye-view imaging during non-coplanar lung SBRT

Purpose: Beam’s-eye-view (BEV) imaging with an electronic portal imaging device (EPID) can be performed during lung stereotactic body radiation therapy (SBRT) to monitor the tumor location in real-time. Image quality for each patient and treatment field depends on several factors including the patient anatomy and the gantry and couch angles. The authors investigated the angular dependence of automatic tumor localization during non-coplanar lung SBRT delivery. Methods: All images were acquired at a frame rate of 12 Hz with an amorphous silicon EPID. A previously validated markerless lung tumor localization algorithm was employed with manual localization as the reference. From ten SBRT patients, 12 987 image frames of 123 image sequences acquired at 48 different gantry–couch rotations were analyzed. δ was defined by the position difference of the automatic and manual localization. Results: Regardless of the couch angle, the best tracking performance was found in image sequences with a gantry angle within 20° of 250° (δ = 1.40 mm). Image sequences acquired with gantry angles of 150°, 210°, and 350° also led to good tracking performances with δ = 1.77–2.00 mm. Overall, the couch angle was not correlated with the tracking results. Among all the gantry–couch combinations, image sequences acquired at (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) led to the best tracking results with δ = 1.19–1.82 mm. The worst performing combinations were (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) with δ > 3.5 mm. However, 35% (17/48) of the gantry–couch rotations demonstrated substantial variability in tracking performances between patients. For example, the field angle (θ = 70°, ϕ = 10°) was acquired for five patients. While the tracking errors were ≤1.98 mm for three patients, poor performance was found for the other two patients with δ ≥ 2.18 mm, leading to average tracking error of 2.70 mm. Only one image sequence was acquired for all other gantry–couch rotations (δ = 1.18–10.29 mm). Conclusions: Non-coplanar beams with gantry–couch rotation of (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) have the highest accuracy for BEV lung tumor localization. Additionally, gantry angles of 150°, 210°, 250°, and 350° also offer good tracking performance. The beam geometries (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) are associated with substantial automatic localization errors. Overall, lung tumor visibility and tracking performance were patient dependent for a substantial number of the gantry–couch angle combinations studied.

60 APPLIED LIFE SCIENCES↗