Search NASASearch

SEARCH · Search NASA

Results for “integrated operating scenarios”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,016 records · Page 57

Advances in Design Capabilities for Planetary Missions from the NASA Entry Systems Modeling and Instrumentation Portfolio

The Entry Systems Modeling project (ESM) is supported by both the NASA Space Technology and the Science Mission Directorates and focuses on developing simulation tools and validated models for characterizing the performance of entry systems tailored to planetary destinations across the Solar System. ESM is organized into six technical capability areas that together address all relevant factors related to spacecraft entry, as well as some aspects of descent: Thermal Protection System (TPS) Materials; Aerothermodynamics; Entry & Descent Vehicle Dynamics; Guidance, Navigation, and Control; Vehicle Systems Analysis; and Advanced Tools and Numerical Methods. Development within the capability areas is undertaken explicitly with a focus on transition and infusion to science missions, human exploration missions, and commercial space activities. The present talk details developments that specifically impact science missions, including simulation tool capabilities that aid in mission design and model development to understand entry system performance at a given destination. Examples of the successful infusion and transition of such project outcomes to science missions also are provided. Several simulation tool development efforts within ESM have resulted in new design capabilities for missions. One such outcome is improved toolsets for mission trajectory and concept of operations design. Specifically, an initiative to couple a leading tool for entry, ascent/descent, and orbital trajectory optimization (Program to Optimize Simulated Trajectories II or POST2) to those used within the Agency for interplanetary trajectory optimization (Copernicus and Monte) has made substantial progress, with the outcomes to date promising to allow efficient trajectory optimization across mission phases. Additionally, toolchains for the evaluation of vehicle performance during entry and descent have been developed that allow assessment of multi-dimensional aeroheating on detailed vehicle geometries, characterization of deployment and inflation of parachutes, and assessment of vehicle dynamic stability during descent. These capabilities are achieved by coupling diverse sets of physics together – material response, computational fluid dynamics, radiation, and vehicle dynamics – to suitably describe complex entry and descent phenomena. Several model development and validation efforts for specific destinations and entry regimes also are underway within the ESM project. For instance, new experimental capabilities to validate radiation models at low densities/high altitudes recently have been established with project support, specifically the Low-Density Shock Tube (LDST) at the NASA Ames Research Center Electric Arc Shock Tube (EAST) facility. The LDST is being leveraged to develop improved models of shock layer kinetics and radiation in Titan atmospheres, while future studies will be conducted in the LDST and the existing high velocity shock tube to provide validation data for radiation models of Venus, Ice Giants, and Mars atmospheres. Models describing the aerothermal and thermo-structural performance of Thermal Protection System (TPS) materials has been another focus, with multiscale modeling activities on-going for the two leading TPS materials applicable to a range of entry conditions and science missions: the Phenolic-Impregnated Carbon Ablator (PICA) and woven materials like 3D Mid-Density Carbon Phenolic (3MDCP). A continual effort is made to infuse and transition outcomes from ESM simulation tool and model development activities into relevant science missions. Significant progress has been made on this front, with missions such as Dragonfly, DAVINCI, and Mars Missions benefitting from project outcomes. The groundwork also is being laid to provide insights into forward looking missions to Gas/Ice Giants as well as for potential sample returns.

Justin Haskins

Laser–plasma amplification of an ultrabroadband laser pulse to 0.3 TW

Producing on-target laser intensities much greater than 10 23 W cm −2 with current laser technologies is a roadblock to accessing new regimes of physics such as strong-field quantum electrodynamics. Laser–plasma amplifiers show promise to realize these intensities by augmenting the final amplifier and compressor in traditional chirped-pulse-amplification architectures with a plasma-based amplification and compression stage that operates at a much higher damage threshold. Here we demonstrate amplification of an ultrabroadband (>60 nm) pulse in a laser–plasma Raman amplifier. We directly amplified seed intensities up to 3.7 × 10 15 W cm −2 and measured efficiencies up to 8.7%. Single-shot SPIDER measurements show a factor-of-2 reduction in the amplified pulse duration with final powers up to 0.3 TW, a 10× improvement over previous results. Final pulse durations of 64 fs are measured. Energy transfers greater than 220 mJ from the picosecond pump into the seed result in a 30× energy amplification of a 7.6 mJ seed. These results set the stage for a compact plasma afterburner based on Raman amplification that could extend the scientific capability of existing petawatt-class laser facilities to enable experiments at the intensity frontier.

Shaw, J. L. [Univ. of Rochester, NY (United States

Toward Trustworthy Autonomous Science: A Two-Year Community Roadmap

One year ago, the AISLE roadmap argued that autonomous laboratories operated as isolated islands and proposed a grassroots network organized around five critical dimensions. The field has since moved faster than that roadmap anticipated: multi-agent systems have produced experimentally validated hypotheses, self-driving laboratories have grown more interoperable and orchestrated, reasoning-trained and domain foundation models have raised the capability ceiling, and the Genesis Mission has placed autonomous experimentation at the center of U.S. federal science strategy, with industry emerging as a primary actor. Progress has met a sobering counter-current, including a corrected flagship discovery result, benchmarks showing that agents which rival experts on closed-ended questions still complete only a fraction of open-ended research, and fabricated citations surfacing at leading venues. We read this as the defining tension of the field: producing a candidate discovery is no longer the hard part, but verifying it is, and this asymmetry now limits autonomous science more than raw model capability. Accordingly, we update the roadmap around seven dimensions, revisiting the original five and elevating two former cross-cutting concerns, trust, verification, and reproducibility, and safety, security, and governance, to first-class status. We assess the original milestones (M1 through M14) as achieved, partially achieved, reframed, or open, add four new milestones (M15 through M18) for the elevated dimensions, and scope the path forward to a two-year horizon, with the first year concentrating on interfaces, protocol adoption, and the scaffolding of verification, and the second targeting federation, zero-trust coordination, and governance. Throughout, we position the grassroots network as the interoperability fabric that lets national programs, international initiatives, and commercial platforms connect rather than re-silo.

99 GENERAL AND MISCELLANEOUS

Plasma phosphorylated tau217 strongly associates with memory deficits in the Alzheimer’s disease spectrum

Abstract Plasma phosphorylated tau (p-tau) biomarkers open unprecedented opportunities for identifying carriers of Alzheimer’s disease pathophysiology in early disease stages using minimally invasive techniques. Plasma p-tau biomarkers are believed to reflect tau phosphorylation and secretion. However, it remains unclear to what extent the magnitude of plasma p-tau abnormalities reflects neuronal network disturbance in the form of cognitive impairment. To address this question, we included 103 cognitively unimpaired elderly and 40 cognitively impaired, amyloid-β-positive individuals from the TRIAD cohort, in addition to 336 cognitively unimpaired and 216 cognitively impaired, amyloid-β-positive older adults from the BioFINDER-2 cohort. Participants had tau PET scans, amyloid PET scans or amyloid CSF, p-tau217, p-tau181 and p-tau231 blood measures, structural T1-MRI and cognitive assessments. In this cross-sectional study, we used regression models and correlation analyses to assess the relationship between plasma biomarkers and cognitive scores. Furthermore, we applied receiver operating characteristic curves to assess cognitive impairment across plasma biomarkers. Finally, we categorized participants into amyloid (A), p-tau (T1) and tau PET (T2) positive (+) or negative (−) profiles and ran non-parametric comparisons to assess differences across cognitive domains. We found that plasma p-tau217 was more associated with cognitive performance than p-tau181 and p-tau231 and that this relationship was particularly strong for memory scores (TRIAD: βp-tau217 = −0.53, βp-tau181 = −0.35 and βp-tau231 = −0.24; BioFINDER-2: βp-tau217 = −0.52, βp-tau181 = −0.24 and βp-tau231 = −0.29). Associations in amyloid-β-positive participants resembled these results, but other cognitive scores also showed strong associations in cognitively impaired individuals. Moreover, plasma p-tau217 outperformed plasma p-tau181 and plasma p-tau231 in identifying memory impairment (area under the curve values for TRIAD: p-tau217 = 0.86, p-tau181 = 0.77 and p-tau231 = 0.75; and for BioFINDER-2: p-tau217 = 0.86, p-tau181 = 0.76 and p-tau231 = 0.81) and in identifying executive function impairment only in the BioFINDER-2 cohort (p-tau217 = 0.82, p-tau181 = 0.76 and p-tau231 = 0.76). Lastly, we showed that subtle memory deficits were present in A+T1+T2− participants for plasma p-tau217 (P = 0.007) and plasma p-tau181 (P = 0.01) in the TRIAD cohort and for all biomarkers across cognitive domains in A+T1+T2− and A+T1+T2− individuals (P < 0.001 in all) in the BioFINDER-2 cohort. The A+T1+T2− individuals showed cognitive deficits in both cohorts (P < 0.001 in all). Together, our results suggest that plasma p-tau217 stands out as a biomarker capable of identifying memory deficits attributable to Alzheimer’s disease and that memory impairment certainly occurs in amyloid-β- and plasma p-tau-positive individuals who have no significant amounts of tau in the neocortex.

Neurosciences & Neurology

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

Combined dark matter search towards dwarf spheroidal galaxies with Fermi -LAT, HAWC, H.E.S.S., MAGIC, and VERITAS

Dwarf spheroidal galaxies (dSphs) are excellent targets for indirect dark matter (DM) searches using gamma-ray telescopes because they are thought to have high DM content and a low astrophysical background. The sensitivity of these searches is improved by combining the observations of dSphs made by different gamma-ray telescopes. We present the results of a combined search by the most sensitive currently operating gamma-ray telescopes, namely: the satellite-borne Fermi -LAT telescope; the ground-based imaging atmospheric Cherenkov telescope arrays H.E.S.S., MAGIC, and VERITAS; and the HAWC water Cherenkov detector. Individual datasets were analyzed using a common statistical approach. Results were subsequently combined via a global joint likelihood analysis. We obtain constraints on the velocity-weighted cross section 〈σv〉 for DM self-annihilation as a function of the DM particle mass. This five-instrument combination allows the derivation of up to 2-3 times more constraining upper limits on 〈σv〉 than the individual results over a wide mass range spanning from 5 GeV to 100 TeV. Depending on the DM content modeling, the 95% confidence level observed limits reach 1.5×10 -24 cm 3 s -1 and 3.2×10 -25 cm 3 s -1 , respectively, in the τ + τ - annihilation channel for a DM mass of 2 TeV.

79 ASTRONOMY AND ASTROPHYSICS

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta (0vββ) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the Laboratori Nazionali del Gran Sasso, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation 0vββ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

Adams, D. Q. [University of South Carolina]

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS