Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Risk of decompression sickness in the presence of circulating microbubbles

In this study, we examined the association between microbubbles formed in the circulation from a free gas phase and symptoms of altitude decompression sickness (DCS). In a subgroup of 59 males of mean (S.D) age 31.2 (5.8) years who developed microbubbles during exposure to 26.59 kPa (4.3 psi) under simulated extravehicular activities (EVA), symptoms of DCS occurred in 24 (41 percent) individuals. Spencer grade 1 microbubbles occurred in 4 (7 percent), grade 2 in 9 (15 percent), grade 3 in 15 (25 percent), and grade 4 in 31 (53 percent) of subjects. Survival analysis using Cox proportional hazards regression showed that individuals with less than grade 3 CMB showed 2.46 times (95 percent confidence interval = 1.26 to 5.34) higher risk of symptoms. This information is crucial for defining the risk of DCS for inflight Doppler monitoring under space EVA. Altitude decompression sickness (DCS) occurs when there is acute reduction in ambient pressure. The symptoms of DCS are due to the formation of a free gas phase (in the form of gas microbubbles) in tissues during decompression. Musculo-skeletal pain of bends is the commonest form of DCS in altitude exposures. In the space flight environment, there is a risk of DCS when astronauts decompress from the normobaric shuttle pressure into the hypobaric space suit pressure (currently about 29.65 kPa (4.3 psi) for extra-vehicular activities (EVA). This risk is counterbalanced by a judicious combination of prior denitrogenation and staged decompression. Studies of DCS are limited by the duration of the test at reduced pressure. Since only a proportion of subjects tested develop symptoms, the information on DCS is generally incomplete or 'censored'. Many studies employ Doppler ultrasound monitoring of the precordial area for detecting circulating microbubbles (CMB). Although the association between CMB and bends pain is not causal, CMB are frequently monitored during decompression. In this paper, we examine the association between CMB and symptoms of DCS under simulated EVA profiles.

Kumar, K. Vasantha↗

Access NASA Satellite Global Precipitation Data Visualization on YouTube

Since the satellite era began, NASA has collected a large volume of Earth science observations for research and applications around the world. The collected and archived satellite data at 12 NASA data centers can also be used for STEM education and activities such as disaster events, climate change, etc. However, accessing satellite data can be a daunting task for non-professional users such as teachers and students because of unfamiliarity of terminology, disciplines, data formats, data structures, computing resources, processing software, programming languages, etc. Over the years, many efforts including tools, training classes, and tutorials have been developed to improve satellite data access for users, but barriers still exist for non-professionals. In this presentation, we will present our latest activity that uses a very popular online video sharing Web site, YouTube (https://www.youtube.com/), for accessing visualizations of our global precipitation datasets at the NASA Goddard Earth Sciences (GES) Data and Information Services Center (DISC). With YouTube, users can access and visualize a large volume of satellite data without the necessity to learn new software or download data. The dataset in this activity is a one-month animation for the GPM (Global Precipitation Measurement) Integrated Multi-satellite Retrievals for GPM (IMERG). IMERG provides precipitation on a near-global (60 deg. N-S) coverage at half-hourly time interval, providing more details on precipitation processes and development compared to the 3-hourly TRMM (Tropical Rainfall Measuring Mission) Multisatellite Precipitation Analysis (TMPA, 3B42) product. When the retro-processing of IMERG during the TRMM era is finished in 2018, the entire video will contain more than 330,000 files and will last ~3.6 hours. Future plans include development of flyover videos for orbital data for an entire satellite mission or project. All videos, including the one-month animation, will be uploaded and available at the GES DISC site on YouTube (https://www.youtube.com/user/NASAGESDISC).

precipitation↗

Atmospheric Correction at AERONET Locations: A New Science and Validation Data Set

This paper describes an AERONET-based Surface Reflectance Validation Network (ASRVN) and its dataset of spectral surface bidirectional reflectance and albedo based on MODIS TERRA and AQUA data. The ASRVN is an operational data collection and processing system. It receives 50x50 square kilometer subsets of MODIS L1B data from MODAPS and AERONET aerosol and water vapor information. Then it performs an accurate atmospheric correction for about 100 AERONET sites based on accurate radiative transfer theory with high quality control of the input data. The ASRVN processing software consists of L1B data gridding algorithm, a new cloud mask algorithm based on a time series analysis, and an atmospheric correction algorithm. The atmospheric correction is achieved by fitting the MODIS top of atmosphere measurements, accumulated for 16-day interval, with theoretical reflectance parameterized in terms of coefficients of the LSRT BRF model. The ASRVN takes several steps to ensure high quality of results: 1) cloud mask algorithm filters opaque clouds; 2) an aerosol filter has been developed to filter residual semi-transparent and sub-pixel clouds, as well as cases with high inhomogeneity of aerosols in the processing area; 3) imposing requirement of consistency of the new solution with previously retrieved BRF and albedo; 4) rapid adjustment of the 16-day retrieval to the surface changes using the last day of measurements; and 5) development of seasonal back-up spectral BRF database to increase data coverage. The ASRVN provides a gapless or near-gapless coverage for the processing area. The gaps, caused by clouds, are filled most naturally with the latest solution for a given pixels. The ASRVN products include three parameters of LSRT model (k(sup L), k(sup G), k(sup V)), surface albedo, NBRF (a normalized BRF computed for a standard viewing geometry, VZA=0 deg., SZA=45 deg.), and IBRF (instantaneous, or one angle, BRF value derived from the last day of MODIS measurement for specific viewing geometry) for MODIS 500m bands 1-7. The results are produced daily at resolution of 1 km in gridded format. We also provide cloud mask, quality flag and a browse bitmap image. The new dataset can be used for a wide range of applications including validation analysis and science research.

Wang, Yujie↗

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Discovery of Activities via Statistical Clustering of Fixation Patterns

Human behavior often consists of a series of distinct activities, each characterized by a unique pattern of interaction with the visual environment. This is true even in a restricted domain, such as a pilot flying an airplane; in this case, activities with distinct visual signatures might be things like communicating, navigating, monitoring, etc. We propose a novel analysis method for gaze-tracking data, to perform blind discovery of these hypothetical activities. We compare, not individual fixations, but groups of fixations aggregated over a fixed time interval (Tau). We assume that the environment has been divided into a finite set of discrete areas-of-interest (AOIs). For a given time interval, we compute the proportion of time spent fixating each AOI, resulting in an N-dimensional vector, where N is the number of AOIs. These proportions can be converted to integer counts by multiplying by Tau divided by the average fixation duration, a parameter that we fix at 283 milliseconds. We compare different intervals by computing the chi-squared statistic. The p-value associated with the statistic is the likelihood of observing the data under the hypothesis that the data in the two intervals were generated by a single process with a single set of probabilities governing the fixation of each AOI. We cluster the intervals, first by merging adjacent intervals that are sufficiently similar, optionally shifting the boundary between non-merged intervals to maximize the difference. Then we compare and cluster non-adjacent intervals. The method is evaluated using synthetic data generated by a hand-crafted set of activities. While the method generally finds more activities than put into the simulation, we have obtained agreement as high as 80 percent between the inferred activity labels and ground truth.

Eye Movements↗

Occupancy schedules learning process through a data mining framework

Building occupancy is a paramount factor in building energy simulations. Specifically, lighting, plug loads, HVAC equipment utilization, fresh air requirements and internal heat gain or loss greatly depends on the level of occupancy within a building. Developing the appropriate methodologies to describe and reproduce the intricate network responsible for human-building interactions are needed. Extrapolation of patterns from big data streams is a powerful analysis technique which will allow for a better understanding of energy usage in buildings. A three-step data mining framework is applied to discover occupancy patterns in office spaces. First, a data set of 16 offices with 10 minute interval occupancy data, over a two year period is mined through a decision tree model which predicts the occupancy presence. Then a rule induction algorithm is used to learn a pruned set of rules on the results from the decision tree model. Finally, a cluster analysis is employed in order to obtain consistent patterns of occupancy schedules. Furthermore, the identified occupancy rules and schedules are representative as four archetypal working profiles that can be used as input to current building energy modeling programs, such as EnergyPlus or IDA-ICE, to investigate impact of occupant presence on design, operation and energy use in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Role of Radiotherapy Alone in Patients With Merkel Cell Carcinoma: Reporting the Australian Experience of 43 Patients

Purpose: To review the role of radiotherapy (RTx) alone in patients with Merkel cell carcinoma (MCC). Methods and Materials: The records of 43 patients with MCC treated with RTx alone between 1993 and 2007 at the Westmead and Royal Brisbane/Mater Hospitals, Australia, were reviewed. Multivariate analysis was performed by use of Cox regression analysis. Results: The median age was 79 years (range, 48-91 years) in 19 women (44%) and 24 men (56%). All patients were white, and 5 (12%) had immunosuppression. A majority (56%) underwent irradiation at initial diagnosis, with the remainder (44%) treated in the relapse setting. The median duration of follow-up was 39 months. The head and neck comprised the most frequently treated site (47%). The median maximum lesion size was 30 mm (range, 5-130 mm). Relapse developed in 60% of patients, with most being out-of-field relapses. The in-field control rate was 75%. Most out-of-field relapses were to visceral organs. Relapse developed outside the irradiated field in 53% of patients. On multivariate analysis, only nodal status (negative nodes vs. nodes present) was significantly associated with relapse-free survival, with p = 0.005 (hazard ratio, 0.25; 95% confidence interval, 0.96-0.663). Overall survival at 2 and 5 years was 58% and 37%, respectively. Conclusions: Patients with MCC treated with RTx have a high likelihood of obtaining in-field control. Doses of 50 to 55 Gy in 20 to 25 fractions are recommended. A minority of patients are cured, with many dying of systemic relapse. Lower dose fractionation schedules (e.g., 25 Gy in 5 fractions) may be considered in patients with a very poor performance status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sources of error in detonation calorimeters and error analysis for neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB)

Here, a calorimeter for measuring heats of detonation at Lawrence Livermore National Laboratory is described. A calibration precision of 0.2 % at the 95 % confidence interval (CI) is reported. Sources of uncertainty are discussed, including nonequivalent sources, which are those arising from differences between calibration and experimental tests. The systematic error due to nonequivalent sources is bounded to 0.19–0.22 % of the measured heat for a standard detonation test where the confinement material is gold. The recommendation is to correct for the systematic error by adding 0.19 % to the reported value and adding 0.03 % to the uncertainty. It is demonstrated that the precision of a detonation test is variable with testing duration because a source of uncertainty resides in the thermodynamic correction factor k6, which accounts for the contribution to heat by stirring; the generated power is additive and therefore highly impacted by total test time. The relative proportion also varies with the magnitude of heat release and sample size, adding variance to the weight of the error arising from the correction factor. A full error analysis based on the described sources of uncertainty is developed. The methodology is applied to a test series on neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB), demonstrating an ultimate precision of 0.7 % (single test) for materials testing and a relative standard deviation of 1.8 %.

47 OTHER INSTRUMENTATION↗

SU-F-T-386: Analysis of Three QA Methods for Predicting Dose Deviation Pass Percentage for Lung SBRT VMAT Plans

Purpose: To investigate the significance of using pinpoint ionization chambers (IC) and RadCalc (RC) in determining the quality of lung SBRT VMAT plans with low dose deviation pass percentage (DDPP) as reported by ScandiDos Delta4 (D4). To quantify the relationship between DDPP and point dose deviations determined by IC (ICDD), RadCalc (RCDD), and median dose deviation reported by D4 (D4DD). Methods: Point dose deviations and D4 DDPP were compiled for 45 SBRT VMAT plans. Eighteen patients were treated on Varian Truebeam linear accelerators (linacs); the remaining 27 were treated on Elekta Synergy linacs with Agility collimators. A one-way analysis of variance (ANOVA) was performed to determine if there were any statistically significant differences between D4DD, ICDD, and RCDD. Tukey’s test was used to determine which pair of means was statistically different from each other. Multiple regression analysis was performed to determine if D4DD, ICDD, or RCDD are statistically significant predictors of DDPP. Results: Median DDPP, D4DD, ICDD, and RCDD were 80.5% (47.6%–99.2%), −0.3% (−2.0%–1.6%), 0.2% (−7.5%–6.3%), and 2.9% (−4.0%–19.7%), respectively. The ANOVA showed a statistically significant difference between D4DD, ICDD, and RCDD for a 95% confidence interval (p < 0.001). Tukey’s test revealed a statistically significant difference between two pairs of groups, RCDD-D4DD and RCDD-ICDD (p < 0.001), but no difference between ICDD-D4DD (p = 0.485). Multiple regression analysis revealed that ICDD (p = 0.04) and D4DD (p = 0.03) are statistically significant predictors of DDPP with an adjusted r{sup 2} of 0.115. Conclusion: This study shows ICDD predicts trends in D4 DDPP; however this trend is highly variable as shown by our low r{sup 2}. This work suggests that ICDD can be used as a method to verify DDPP in delivery of lung SBRT VMAT plans. RCDD may not validate low DDPP discovered in D4 QA for small field SBRT treatments.

60 APPLIED LIFE SCIENCES↗

Design and analysis of an integrated pulse modulated s-band power amplifier in gallium nitride process

The design of power amplifiers in any semi-conductor process is not a trivia exercise and it is often encountered that the simulated solution is qualitatively different than the results obtained. Phenomena such as oscillation occurring either in-band or out of band and sometimes at subharmonic intervals, continuous spectrum noticed in some frequency bands, often referred to as chaos, and jumps and hysteresis effects can all be encountered and render a design useless. All of these problems might have been identified through a more rigorous approach to stability analysis. Designing for stability is probably the one area of amplifier design that receives the least amount of attention but incurs the most catastrophic of effects if it is not performed properly. Other parameters such as gain, power output, frequency response and even matching may suitable mitigation paths. But the lack of stability in an amplifier has no mitigating path. In addition to of loss of the design completely there are the increased production cycle costs, costs involved with investigating and resolving the problem and the costs involved with schedule slips or delays resulting from it. The Linville or Rollett stability criteria that many microwave engineers follow and rely exclusively on is not sufficient by itself to ensure a stable and robust design. It will be shown that the universal belief that unconditional stability is obtained through an analysis of the scattering matrix S to determine if 1 and |{Delta}{sub S}| < 1 is only part of the procedure and other tools must be used to validate the criteria. The research shown contributes to the state of the art by developing a more thorough stability design technique for designing amplifiers of any class, whether that be current mode or switch mode, than is currently undertaken with the goal of obtaining first pass design success.

42 ENGINEERING↗

Dose-Escalated Stereotactic Body Radiation Therapy for Patients With Intermediate- and High-Risk Prostate Cancer: Initial Dosimetry Analysis and Patient Outcomes

Purpose: To report the short-term clinical outcomes and acute and late treatment-related genitourinary (GU) and gastrointestinal (GI) toxicities in patients with intermediate- and high-risk prostate cancer treated with dose-escalated stereotactic body radiation therapy (SBRT). Methods and Materials: Between 2011 and 2014, 24 patients with prostate cancer were treated with SBRT to the prostate gland and proximal seminal vesicles. A high-dose avoidance zone (HDAZ) was created by a 3-mm expansion around the rectum, urethra, and bladder. Patients were treated to a minimum dose of 36.25 Gy in 5 fractions, with a simultaneous dose escalation to a dose of 50 Gy to the target volume away from the HDAZ. Acute and late GU and GI toxicity outcomes were measured according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 4. Results: The median follow-up was 25 months (range, 18-45 months). Nine patients (38%) experienced an acute grade 2 GU toxicity, which was medically managed, and no patients experienced an acute grade 2 GI toxicity. Two patients (8%) experienced late grade 2 GU toxicity, and 2 patients (8%) experienced late grade 2 GI toxicity. No acute or late grade ≥3 GU or GI toxicities were observed. The 24-month prostate-specific antigen relapse-free survival outcome for all patients was 95.8% (95% confidence interval 75.6%-99.4%), and both biochemical failures occurred in patients with high-risk disease. All patients are currently alive at the time of this analysis and continue to be followed. Conclusions: A heterogeneous prostate SBRT planning technique with differential treatment volumes (low dose: 36.25 Gy; and high dose: 50 Gy) with an HDAZ provides a safe method of dose escalation. Favorable rates of biochemical control and acceptably low rates of acute and long-term GU and GI toxicity can be achieved in patients with intermediate- and high-risk prostate cancer treated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture Analysis of Cohesive Zone Models for Modeling Residual Stress Induced Delamination in Composite Structures

A fracture study of coupon-scale composite cylinders with embedded defects was conducted with an objective to assess and validate a modeling approach using two available cohesive material models. The study included experimental and simulation evaluations of initiation of crack growth and progression. Interrupted thermal experiments used acoustic emissions monitoring to identify the onset of crack progression during each cooling interval and ultrasonic scanning provided images of defect growth. Verification, validation, and uncertainty quantification (VVUQ) processes were performed in the assessment of the simulation predicted temperature at which crack propagation begins (quantity of interest). The Sobol sensitivity analysis identified the hoop direction elastic modulus in the carbon fiber reinforced polymer (CFRP) plies as the most influential parameter for simulations using both cohesive models, accounting for at least 70% of the variation in the temperature at crack propagation. The UQ temperature range for the Tvergaard-Hutchinson model was higher (more conservative) than the experimental acoustic measurement indicators of crack progression, while the temperature range for the Thouless-Parmigiani model enveloped the experimental data points for the primary defect size of 0.75 x 1 in. The simulations could not capture the stable crack growth indicated in the experiments. This is likely due to the models’ inability to represent anisotropic fracture toughness attributed to the structure of the orthotropic fiber weave in a woven composite laminate.

42 ENGINEERING↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

Cluster analysis based on dimensional information with applications to feature selection and classification

A new clustering algorithm is presented that is based on dimensional information. The algorithm includes an inherent feature selection criterion, which is discussed. Further, a heuristic method for choosing the proper number of intervals for a frequency distribution histogram, a feature necessary for the algorithm, is presented. The algorithm, although usable as a stand-alone clustering technique, is then utilized as a global approximator. Local clustering techniques and configuration of a global-local scheme are discussed, and finally the complete global-local and feature selector configuration is shown in application to a real-time adaptive classification scheme for the analysis of remote sensed multispectral scanner data.

Eigen, D. J.↗

Ion cyclotron waves near L = 4.6 - A ground-satellite correlation study

Results are presented of the first ground-satellite correlation study of ion cyclotron wave events inside geosynchronous orbit. Several intervals are found during which waves at the same frequency were observed simultaneously by the DE 1 Goddard Space Flight Center Fluxgate Magnetometer and by the Air Force Geophysics Laboratory Magnetometer Network. This represents about 33 percent of the intervals during which waves were seen on the ground and DE 1 was in a favorable location (near the geomagnetic equator around L = 4.6) to observe the wave generation region. Three of seven simultaneous events showed a positive correlation when a detailed correlation analysis was performed. Peaks in the the cross-correlation function occurred at delays of 30-100 s and are interpreted as the group delay time of signals from space to the ground station. The small number of events seen in space during conjunction intervals results from the satellite's path missing the source region.

Ludlow, G. R.↗

Computer based imaging and analysis of root gravitropism

Two key issues in studies of the nature of the gravitropic response in roots have been the determination of the precise pattern of differential elongation responsible for downward bending and the identification of the cells that show the initial motor response. The main approach for examining patterns of differential growth during root gravitropic curvature has been to apply markers to the root surface and photograph the root at regular intervals during gravitropic curvature. Although these studies have provided valuable information on the characteristics of the gravitropic motor response in roots, their labor intensive nature limits sample size and discourages both high frequency of sampling and depth of analysis of surface expansion data. In this brief review we describe the development of computer-based video analysis systems for automated measurement of root growth and shape change and discuss some key features of the root gravitropic response that have been revealed using this methodology. We summarize the capabilities of several new pieces of software designed to measure growth and shape changes in graviresponding roots and describe recent progress in developing analysis systems for studying the small, but experimentally popular, primary roots of Arabidopsis. A key finding revealed by such studies is that the initial gravitropic response of roots of maize and Arabidopsis occurs in the distal elongation zone (DEZ) near the root apical meristem, not in the main elongation zone. Another finding is that the initiation of rapid elongation in the DEZ following gravistimulation appears to be related to rapid membrane potential changes in this region of the root. These observations have provided the incentive for ongoing studies examining possible links between potential growth modifying factors (auxin, calcium, protons) and gravistimulated changes in membrane potential and growth patterns in the DEZ.

NASA Discipline Plant Biology↗

Moving Beyond Mortality: Development and Application of a Desirability of Outcome Ranking (DOOR) Endpoint for Hospital-Acquired Bacterial Pneumonia and Ventilator-Associated Bacterial Pneumonia

Abstract Background Hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) are frequently caused by multidrug-resistant organisms. Patient-centered endpoints in clinical trials are needed to develop new antibiotics for HABP/VABP. Desirability of outcome ranking (DOOR) is a paradigm for the design, analysis, and interpretation of clinical trials based on a patient-centered, benefit-risk evaluation. Methods A multidisciplinary committee created an infectious diseases DOOR endpoint customized for HABP/VABP, incorporating infectious complications, serious adverse events, and mortality. We applied this to 2 previously completed, large randomized controlled trials for HABP/VABP. ZEPHyR compared vancomycin to linezolid and VITAL compared linezolid to tedizolid. For each trial, we evaluated the DOOR distribution and probability, including DOOR component and partial credit analyses. We also applied DOOR in subgroup analyses. Results In both trials, the HABP/VABP DOOR demonstrated similar overall clinical outcomes between treatment groups. In ZEPHyR, the probability that a participant treated with linezolid would have a more desirable outcome than a participant treated with vancomycin was 50.2% (95% confidence interval [CI], 45.1%­−55.3%). In VITAL, the probability that a participant treated with tedizolid would have a more desirable outcome than a participant treated with linezolid was 48.7% (95% CI, 44.8%–52.6%). The DOOR component analysis revealed that participants treated with tedizolid had a less desirable outcome than those treated with linezolid when considering clinical response alone. However, participants with decreased renal function had improved overall outcomes with tedizolid. Conclusions The HABP/VABP DOOR provided more granular information about clinical outcomes than is typically presented in clinical trials. HABP/VABP trials would benefit from prospectively using DOOR.

Immunology↗

Clinical Usefulness of [(18)F]Fluoro-2-Deoxy-D-Glucose Uptake in 178 Head-and-Neck Cancer Patients With Nodal Metastasis Treated With Definitive Chemoradiotherapy: Consideration of Its Prognostic Value and Ability to Provide Guidance for Optimal Selection of Patients for Planned Neck Dissection

Purpose: To evaluate the clinical effectiveness of pretreatment [(18)F]fluoro-2-deoxy-D-glucose-positron emission tomography for head-and-neck squamous cell carcinoma patients with nodal metastasis treated with chemoradiotherapy. Methods and Materials: Between March 2002 and December 2006, 178 patients with head-and-neck squamous cell carcinoma and nodal metastasis underwent fluoro-2-deoxy-D-glucose positron emission tomography before chemoradiotherapy. Fluoro-2-deoxy-D-glucose uptake by both the primary lesion and the neck node was measured using the standard uptake value (SUV). The overall survival, disease-free survival, local control, nodal progression-free survival, and distant metastasis-free survival rates were calculated, and several prognostic factors were evaluated. Results: The patients with a nodal SUV {>=}6.00 had a significantly lower 3-year disease-free survival rate than those with a lower SUV (44% vs. 69%, p = .004). On multivariate analysis, a high SUV of nodal disease also proved to be a significantly unfavorable factor for disease-free survival (p = .04, 95% confidence interval [CI], 1.02-3.23), nodal progression-free survival (p = .05; 95% CI, 1.00-4.15), and distant metastasis-free survival (p = .016; 95% CI, 1.25-8.92). Among the patients with a greater nodal SUV ({>=}6.00), those treated with planned neck dissection had better nodal progression-free survival than those in the observation group (p = .04, hazard ratio, 2.36; 95% CI, 1.00-5.85). Conclusion: Among head-and-neck squamous cell carcinoma patients treated with chemoradiotherapy, the pretreatment SUV of nodal disease was one of the strongest prognostic factors and also provided important information for the selection of patients suitable for planned neck dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗