Search NASA⌕ Search

SEARCH · Search NASA

Results for “kernel method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

MO-FG-204-04: How Iterative Reconstruction Algorithms Affect the NPS of CT Images

Purpose: To evaluate how the third generation model based iterative reconstruction (MBIR) compares with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASiR), and the second generation MBIR based on noise power spectrum (NPS) analysis over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP515 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 19mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 0.984 pitch and reconstructed thickness 2.5mm (VEO3.0: Abd/Pelvis with Texture and NR05). At each CTDIvol level, 10 repeated scans were acquired for achieving sufficient data sampling. The images were reconstructed using Standard kernel with FBP; 20%, 40% and 70% ASiR; and two versions of MBIR (VEO2.0 and 3.0). For evaluating the effect of the ROI spatial location to the Result of NPS, 4 ROI groups were categorized based on their distances from the center of the phantom. Results: VEO3.0 performed inferiorly comparing to VEO2.0 over all dose levels. On the other hand, at low dose levels (less than 3 mGy), it clearly outperformed ASiR and FBP, in NPS values. Therefore, the lower the dose level, the relative performance of MBIR improves. However, the shapes of the NPS show substantial differences in horizontal and vertical sampling dimensions. These differences may determine the characteristics of the noise/texture features in images, and hence, play an important role in image interpretation. Conclusion: The third generation MBIR did not improve over the second generation MBIR in term of NPS analysis. The overall performance of both versions of MBIR improved as compared to other reconstruction algorithms when dose was reduced. The shapes of the NPS curves provided additional value for future characterization of the image noise/texture features.

60 APPLIED LIFE SCIENCES↗

Coaction and double-copy properties of configuration-space integrals at genus zero

We investigate configuration-space integrals over punctured Riemann spheres from the viewpoint of the motivic Galois coaction and double-copy structures generalizing the Kawai-Lewellen-Tye (KLT) relations in string theory. For this purpose, explicit bases of twisted cycles and cocycles are worked out whose orthonormality simplifies the coaction. We present methods to efficiently perform and organize the expansions of configuration-space integrals in the inverse string tension α' or the dimensional-regularization parameter ϵ of Feynman integrals. Generating-function techniques open up a new perspective on the coaction of multiple polylogarithms in any number of variables and analytic continuations in the unintegrated punctures. We present a compact recursion for a generalized KLT kernel and discuss its origin from intersection numbers of Stasheff polytopes and its implications for correlation functions of two-dimensional conformal field theories. We find a non-trivial example of correlation functions in (p, 2) minimal models, which can be normalized to become uniformly transcendental in the p → ∞ limit.

Conformal Field Theory↗

Accurately simulating core-collapse self-interacting dark matter halos

The properties of satellite halos provide a promising probe for dark matter (DM) physics. Observations have motivated current efforts to explain surprisingly compact DM halos. If DM is not collisionless, but has strong self-interactions, halos can undergo gravothermal collapse, leading to higher densities in the central region of the halo. However, it is challenging to model this collapse phase from first principles. To improve on this, we sought to better understand the numerical challenges and convergence properties of self-interacting dark matter (SIDM) N-body simulations in the collapse phase. Especially, our aim was to better understand the evolution of satellite halos. To do so, we ran SIDM N-body simulations of a low-mass halo in isolation and within an external gravitational potential. The simulation set-up was motivated by the perturber of the stellar stream GD-1. We find that the halo evolution is very sensitive to energy conservation errors, and a SIDM kernel size that is too large can artificially speed up the collapse. Moreover, we demonstrate that the King model can describe the density profile at small radii for the late stages that we have simulated. Furthermore, for our most highly resolved simulation (N = 5 × 10 7 ) we have made the data public. It can serve as a benchmark. Overall, we find that the current numerical methods do not suffer from convergence problems in the late collapse phase and provide guidance on how to choose numerical parameters, for example that the energy conservation error is better kept well below 1%. This allows simulations to be run of halos that become concentrated enough to explain observations of GD-1-like stellar streams or strong gravitational lensing systems.

dark matter↗

Point Spread Function Estimation and Uncertainty Quantification

An important component of analyzing images quantitatively is modeling image blur due to effects from the system for image capture. When the effect of image blur is assumed to be translation invariant and isotropic, it can be generally modeled as convolution with a radially symmetric kernel, called the point spread function (PSF). Standard techniques for estimating the PSF involve imaging a bright point source, but this is not always feasible (e.g. high energy radiography). This work provides a novel non-parametric approach to estimating the PSF from a calibration image of a vertical edge. Moreover, the approach is within a hierarchical Bayesian framework that in addition to providing a method for estimation, also gives a quantification of uncertainty in the estimate by Markov Chain Monte Carlo methods.

97 MATHEMATICS AND COMPUTING↗

Key results from irradiation and post-irradiation examination of AGR-1 UCO TRISO fuel

The AGR-1 irradiation experiment was performed as the first test of tristructural isotropic (TRISO) fuel in the US Advanced Gas Reactor Fuel Development and Qualification Program. The experiment consisted of 72 right cylinder fuel compacts containing approximately 3 × 105 coated fuel particles with uranium oxide/uranium carbide (UCO) fuel kernels. The fuel was irradiated in the Advanced Test Reactor for a total of 620 effective full power days. Fuel burnup ranged from 11.3 to 19.6% fissions per initial metal atom and time-average, volume-average irradiation temperatures of the individual compacts ranged from 955 to 1136 °C. This paper focuses on key results from the irradiation and post-irradiation examination, which revealed a robust fuel with excellent performance characteristics under the conditions tested and have significantly improved the understanding of UCO coated particle fuel irradiation behavior. The fuel exhibited zero TRISO coating failures (failure of all three dense coating layers) during irradiation and post-irradiation safety testing at temperatures up to 1700 °C. Advanced PIE methods have allowed particles with SiC coating failure that were discovered to be present in a very-low population to be isolated and meticulously examined, which has elucidated the specific causes of SiC failure in these specimens. The level of fission product release from the fuel during irradiation and post-irradiation safety testing has been studied in detail. Results indicated very low release of krypton and cesium through intact SiC and modest release of europium and strontium, while also confirming the potential for significant silver release through the coatings depending on irradiation conditions. Focused study of fission products within the coating layers of irradiated particles down to nanometer length scales has provided new insights into fission product transport through the coating layers and the role various fission products may have on coating integrity. The broader implications of these results and the application of lessons learned from AGR-1 to fuel fabrication and post-irradiation examination for subsequent fuel irradiation experiments as part of the US fuel program are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Xyce parallel electronic simulator : users' guide. Version 5.1.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: (1) Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). Note that this includes support for most popular parallel and serial computers. (2) Improved performance for all numerical kernels (e.g., time integrator, nonlinear and linear solvers) through state-of-the-art algorithms and novel techniques. (3) Device models which are specifically tailored to meet Sandia's needs, including some radiation-aware devices (for Sandia users only). (4) Object-oriented code design and implementation using modern coding practices that ensure that the Xyce Parallel Electronic Simulator will be maintainable and extensible far into the future. Xyce is a parallel code in the most general sense of the phrase - a message passing parallel implementation - which allows it to run efficiently on the widest possible number of computing platforms. These include serial, shared-memory and distributed-memory parallel as well as heterogeneous platforms. Careful attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The development of Xyce provides a platform for computational research and development aimed specifically at the needs of the Laboratory. With Xyce, Sandia has an 'in-house' capability with which both new electrical (e.g., device model development) and algorithmic (e.g., faster time-integration methods, parallel solver algorithms) research and development can be performed. As a result, Xyce is a unique electrical simulation capability, designed to meet the unique needs of the laboratory.

99 GENERAL AND MISCELLANEOUS↗

Xyce Parallel Electronic Simulator : users' guide, version 4.1.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: (1) Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). Note that this includes support for most popular parallel and serial computers. (2) Improved performance for all numerical kernels (e.g., time integrator, nonlinear and linear solvers) through state-of-the-art algorithms and novel techniques. (3) Device models which are specifically tailored to meet Sandia's needs, including some radiation-aware devices (for Sandia users only). (4) Object-oriented code design and implementation using modern coding practices that ensure that the Xyce Parallel Electronic Simulator will be maintainable and extensible far into the future. Xyce is a parallel code in the most general sense of the phrase - a message passing parallel implementation - which allows it to run efficiently on the widest possible number of computing platforms. These include serial, shared-memory and distributed-memory parallel as well as heterogeneous platforms. Careful attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The development of Xyce provides a platform for computational research and development aimed specifically at the needs of the Laboratory. With Xyce, Sandia has an 'in-house' capability with which both new electrical (e.g., device model development) and algorithmic (e.g., faster time-integration methods, parallel solver algorithms) research and development can be performed. As a result, Xyce is a unique electrical simulation capability, designed to meet the unique needs of the laboratory.

99 GENERAL AND MISCELLANEOUS↗

Quantitative comparison of noise texture across CT scanners from different manufacturers

Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm{sup 2} (0.002 mm{sup -1}) to 0.29 mm{sup 2} (0.74 mm{sup -1}). The GE kernels 'Soft,''Standard,''Chest,' and 'Lung' closely matched the Siemens kernels 'B35f,''B43f,''B41f,' and 'B80f' (RMSD < 0.05 mm{sup 2}, |PFD| < 0.02 mm{sup -1}, respectively). The GE 'Bone,''Bone+,' and 'Edge' kernels all matched most closely with Siemens 'B75f' kernel but with sizeable RMSD and |PFD| values up to 0.18 mm{sup 2} and 0.41 mm{sup -1}, respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.

60 APPLIED LIFE SCIENCES↗

Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS were found to be different due to the difference in the tomosynthesis image reconstruction algorithms. Conclusions: It is feasible to simultaneously generate x-ray differential phase contrast, phase contrast, and absorption contrast tomosynthesis images using a grating-based data acquisition setup. The method shows promise in improving the visibility of several low-density materials and therefore merits further investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Perspective on information fusion problems, Extended Abstract, Journal of Distributed Sensor Neworks

Information fusion problems have a rich history spanning four centuries and several disciplines as diverse as political economy, reliability engineering, target tracking, bioinformatics, forecasting, distributed detection, robotics, cyber security, nuclear engineering, distributed sensor networks, and others. Over the past decade, the area of information fusion has been established as a discipline by itself with several contributions to its foundations as well as applications. In a basic formulation of the information fusion problem, each component is characterized by a probability distribution. The goal is to estimate a fusion rule for combining the outputs of components to achieve a specified objective such as better performance or functionality compared to the components. If the sensor error distributions are known, several fusion rule estimation problems have been formulated and solved using deterministic methods. In the area of pattern recognition a weighted majority fuser was shown to be optimal in combining outputs from pattern recognizers under statistical independence conditions. A simpler version of this problem corresponds to the Condorcet Jury theorem proposed in 1786. This result was rediscovered since then in other disciplines including by von Neumann in 1959 in building reliable computing devices. The distributed detection problem, studied extensively in the target tracking area, can be viewed as a generalization of the above two problems. In these works, the underlying distributions are assumed to be known, which is quite reasonable in the areas these methods are applied. In a different formulation, we consider estimating the fuser based on empirical data when no information is available about the underlying distributions of components. Using the empirical estimation methods, this problem is shown to be solvable in principle, and the fuser performance may be sharpened based on the specific formulation. The isolation fusers perform at least as good as best component, and the projective fusers perform as good as best combination of components. In a special case of function estimation, each component could be a potential function estimator, radial basis function, nearest neighbor estimator, regressogram, kernel estimator, regression tree or another estimator. A projective fuser based on a nearest neighbor concept has been proposed based on Voronoi regions in this case. Under fairly general smoothness and non-smoothness conditions on the individual estimators, the expected fuser error is close to optimal with a specified probability. This result is purely sample-based and distribution-free in that it does not require the knowledge of underlying distributions and can be computed only using measurements.

99 GENERAL AND MISCELLANEOUS↗

Polarization of bremsstrahlung at electron scattering in an anisotropic medium

Bremsstrahlung from relativistic electrons is considered under conditions when some transverse direction of momentum transfer is statistically preferred. It is shown that in the dipole approximation all the medium anisotropy effects can be accumulated into a special modulus-bound transverse vector, N. To exemplify a target with N{sup 2}{approx}1, we calculate radiation from an electron incident at a small angle on an atomic row in an oriented crystal. Radiation intensity and polarization dependencies on the emission angle and frequency for constant N are investigated. Net polarization for the angle-integral cross section is evaluated, which appears to be proportional to N{sup 2}/2, and decreases with the increase of the photon energy fraction. A prominent feature of the radiation angular distribution is the existence of an angle at which the radiation may be completely polarized, in spite of the target complete or partial isotropy; that owes to existence of an origin-centered tangential circle for polarization in the fully differential radiation probability kernel. Possibilities for utilizing various properties of the polarized bremsstrahlung flux for preparation of polarized photon beams and for probing intrinsic anisotropy of the medium are analyzed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Xyce parallel electronic simulator : users' guide.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: (1) Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). Note that this includes support for most popular parallel and serial computers; (2) Improved performance for all numerical kernels (e.g., time integrator, nonlinear and linear solvers) through state-of-the-art algorithms and novel techniques. (3) Device models which are specifically tailored to meet Sandia's needs, including some radiation-aware devices (for Sandia users only); and (4) Object-oriented code design and implementation using modern coding practices that ensure that the Xyce Parallel Electronic Simulator will be maintainable and extensible far into the future. Xyce is a parallel code in the most general sense of the phrase - a message passing parallel implementation - which allows it to run efficiently on the widest possible number of computing platforms. These include serial, shared-memory and distributed-memory parallel as well as heterogeneous platforms. Careful attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The development of Xyce provides a platform for computational research and development aimed specifically at the needs of the Laboratory. With Xyce, Sandia has an 'in-house' capability with which both new electrical (e.g., device model development) and algorithmic (e.g., faster time-integration methods, parallel solver algorithms) research and development can be performed. As a result, Xyce is a unique electrical simulation capability, designed to meet the unique needs of the laboratory.

99 GENERAL AND MISCELLANEOUS↗

MO-E-18C-04: Advanced Computer Simulation and Visualization Tools for Enhanced Understanding of Core Medical Physics Concepts

Purpose: Most medical physics programs emphasize proficiency in routine clinical calculations and QA. The formulaic aspect of these calculations and prescriptive nature of measurement protocols obviate the need to frequently apply basic physical principles, which, therefore, gradually decay away from memory. E.g. few students appreciate the role of electron transport in photon dose, making it difficult to understand key concepts such as dose buildup, electronic disequilibrium effects and Bragg-Gray theory. These conceptual deficiencies manifest when the physicist encounters a new system, requiring knowledge beyond routine activities. Methods: Two interactive computer simulation tools are developed to facilitate deeper learning of physical principles. One is a Monte Carlo code written with a strong educational aspect. The code can “label” regions and interactions to highlight specific aspects of the physics, e.g., certain regions can be designated as “starters” or “crossers,” and any interaction type can be turned on and off. Full 3D tracks with specific portions highlighted further enhance the visualization of radiation transport problems. The second code calculates and displays trajectories of a collection electrons under arbitrary space/time dependent Lorentz force using relativistic kinematics. Results: Using the Monte Carlo code, the student can interactively study photon and electron transport through visualization of dose components, particle tracks, and interaction types. The code can, for instance, be used to study kerma-dose relationship, explore electronic disequilibrium near interfaces, or visualize kernels by using interaction forcing. The electromagnetic simulator enables the student to explore accelerating mechanisms and particle optics in devices such as cyclotrons and linacs. Conclusion: The proposed tools are designed to enhance understanding of abstract concepts by highlighting various aspects of the physics. The simulations serve as virtual experiments that give deeper and long lasting understanding of core principles. The student can then make sound judgements in novel situations encountered beyond routine clinical activities.

60 APPLIED LIFE SCIENCES↗

Verification of a Configuration Space Method for Evaluating the All-Orders Linear Kinetic Plasma Response to RF Power

Progress towards verification of a configuration space algorithm for evaluating the linear kinetic plasma current response to applied radio-frequency power is presented. This follows a previously published [1] verification of the parallel-only response, by verifying the perpendicular response required for much of the ion-and electron-cyclotron range of frequencies. In particular, we use the Colestock-Kashuba fast-wave to ion-Bernstein-wave benchmark [2] where we show that the Kinetic-J computational kernel is able to reproduce a known reference solution calculated via the AORSA full-wave code [3]. We also discuss the computational and scaling aspects of this novel approach, as well as the difficulties presented by the temporal scales in this multi-species problem.

Green, David↗

THE ADJOINT METHOD APPLIED TO TIME-DISTANCE HELIOSEISMOLOGY

For a given misfit function, a specified optimality measure of a model, its gradient describes the manner in which one may alter properties of the system to march toward a stationary point. The adjoint method, arising from partial-differential-equation-constrained optimization, describes a means of extracting derivatives of a misfit function with respect to model parameters through finite computation. It relies on the accurate calculation of wavefields that are driven by two types of sources, namely, the average wave-excitation spectrum, resulting in the forward wavefield, and differences between predictions and observations, resulting in an adjoint wavefield. All sensitivity kernels relevant to a given measurement emerge directly from the evaluation of an interaction integral involving these wavefields. The technique facilitates computation of sensitivity kernels (Frechet derivatives) relative to three-dimensional heterogeneous background models, thereby paving the way for nonlinear iterative inversions. An algorithm to perform such inversions using as many observations as desired is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal relaxation and the complete set of second-order transport coefficients for the unitary Fermi gas from kinetic theory

We compute the complete set of second-order transport coefficients of the unitary Fermi gas, a dilute gas of spin-1/2 particles interacting via an 𝑠 -wave interaction tuned to infinite scattering length. The calculation is based on kinetic theory and the Chapman-Enskog method at second order in the Knudsen expansion. We take into account the exact two-body collision integral. We extend previous results on second-order coefficients related to shear stress by including terms related to heat flow and gradients of the fugacity. We confirm that the thermal relaxation time is given by the simple estimate 𝜏 𝜅 = 𝜅⁢𝑚/(𝑐 𝑃 ⁢𝑇) even if the full collision kernel is taken into account. Furthermore, 𝜅 is the thermal conductivity, 𝑚 is the mass of the particles, 𝑐𝑃 is the specific heat at constant pressure, and 𝑇 is the temperature.

Kinetic theory↗

Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei in preparation of clinical application

Purpose: The purpose of this study is to develop a new calculation algorithm that is satisfactory in terms of the requirements for both accuracy and calculation time for a simulation of imaging of the proton-irradiated volume in a patient body in clinical proton therapy. Methods: The activity pencil beam algorithm (APB algorithm), which is a new technique to apply the pencil beam algorithm generally used for proton dose calculations in proton therapy to the calculation of activity distributions, was developed as a calculation algorithm of the activity distributions formed by positron emitter nuclei generated from target nuclear fragment reactions. In the APB algorithm, activity distributions are calculated using an activity pencil beam kernel. In addition, the activity pencil beam kernel is constructed using measured activity distributions in the depth direction and calculations in the lateral direction. {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei were determined as the major target nuclei that constitute a human body that are of relevance for calculation of activity distributions. In this study, ''virtual positron emitter nuclei'' was defined as the integral yield of various positron emitter nuclei generated from each target nucleus by target nuclear fragment reactions with irradiated proton beam. Compounds, namely, polyethylene, water (including some gelatin) and calcium oxide, which contain plenty of the target nuclei, were irradiated using a proton beam. In addition, depth activity distributions of virtual positron emitter nuclei generated in each compound from target nuclear fragment reactions were measured using a beam ON-LINE PET system mounted a rotating gantry port (BOLPs-RGp). The measured activity distributions depend on depth or, in other words, energy. The irradiated proton beam energies were 138, 179, and 223 MeV, and measurement time was about 5 h until the measured activity reached the background level. Furthermore, the activity pencil beam data were made using the activity pencil beam kernel, which was composed of the measured depth data and the lateral data including multiple Coulomb scattering approximated by the Gaussian function, and were used for calculating activity distributions. Results: The data of measured depth activity distributions for every target nucleus by proton beam energy were obtained using BOLPs-RGp. The form of the depth activity distribution was verified, and the data were made in consideration of the time-dependent change of the form. Time dependence of an activity distribution form could be represented by two half-lives. Gaussian form of the lateral distribution of the activity pencil beam kernel was decided by the effect of multiple Coulomb scattering. Thus, the data of activity pencil beam involving time dependence could be obtained in this study. Conclusions: The simulation of imaging of the proton-irradiated volume in a patient body using target nuclear fragment reactions was feasible with the developed APB algorithm taking time dependence into account. With the use of the APB algorithm, it was suggested that a system of simulation of activity distributions that has levels of both accuracy and calculation time appropriate for clinical use can be constructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Shortwave Radiative Kernels of Marine Boundary-layer Clouds Using Scanning Radar/Lidar and Array Spectroradiometer

This project set out to use synergetic measurements from the ARM program to observe 3D cloud field observations, and to investigate how inadequate treatment of the observed 3D characteristics of clouds in models may impact estimates of low-cloud feedback magnitude. The project comprises three components, including 1) retrieving cloud and precipitation properties, 2) developing fast radiative transfer code incorporating 3D cloud effects, and 3) estimating 3D effects/impacts on a global scale. This report documents our main research outcomes. Specifically, a novel cloud retrieval method is developed, allowing us to better characterize cloud population and sizes, drizzle properties and precipitation formation, and to better understand their interactions with aerosols. These observed 3D cloud fields were used in a fast radiative transfer code, helping discover non-negligible 3D radiative effects in the longwave spectral region. The retrieved cloud properties were also used to investigate several hypothesized cloud feedback processes.

47 OTHER INSTRUMENTATION↗