Search NASA⌕ Search

SEARCH · Search NASA

Results for “limiting techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

ON PULSAR DISTANCE MEASUREMENTS AND THEIR UNCERTAINTIES

Accurate distances to pulsars can be used for a variety of studies of the Galaxy and its electron content. However, most distance measures to pulsars have been derived from the absorption (or lack thereof) of pulsar emission by Galactic H I gas, which typically implies that only upper or lower limits on the pulsar distance are available. We present a critical analysis of all measured H I distance limits to pulsars and other neutron stars, and translate these limits into actual distance estimates through a likelihood analysis that simultaneously corrects for statistical biases. We also apply this analysis to parallax measurements of pulsars in order to obtain accurate distance estimates and find that the parallax and H I distance measurements are biased in different ways, because of differences in the sampled populations. Parallax measurements typically underestimate a pulsar's distance because of the limited distance to which this technique works and the consequential strong effect of the Galactic pulsar distribution (i.e., the original Lutz-Kelker bias), in H I distance limits, however, the luminosity bias dominates the Lutz-Kelker effect, leading to overestimated distances because the bright pulsars on which this technique is applicable are more likely to be nearby given their brightness.

79 ASTRONOMY AND ASTROPHYSICS↗

Dosimetric quality, accuracy, and deliverability of modulated radiotherapy treatments for spinal metastases

Cancer often metastasizes to the vertebra, and such metastases can be treated successfully using simple, static posterior or opposed-pair radiation fields. However, in some cases, including when re-irradiation is required, spinal cord avoidance becomes necessary and more complex treatment plans must be used. This study evaluated 16 sample intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans designed to treat 6 typical vertebral and paraspinal volumes using a standard prescription, with the aim of investigating the advantages and limitations of these treatment techniques and providing recommendations for their optimal use in vertebral treatments. Treatment plan quality and beam complexity metrics were evaluated using the Treatment And Dose Assessor (TADA) code. A portal-imaging–based quality assurance (QA) system was used to evaluate treatment delivery accuracy, and radiochromic film measurements were used to provide high-resolution verification of treatment plan dose accuracy, especially in the steep dose gradient regions between each vertebral target and spinal cord. All treatment modalities delivered approximately the same doses and the same levels of dose heterogeneity to each planning target volume (PTV), although the minimum PTV doses in the vertebral plans were substantially lower than the prescription, because of the requirement that the plans meet a strict constraint on the dose to the spinal cord and cord planning risk volume (PRV). All plans met required dose constraints on all organs at risk, and all measured PTV-cord dose gradients were steeper than planned. Beam complexity analysis suggested that the IMRT treatment plans were more deliverable (less complex, leading to greater QA success) than the VMAT treatment plans, although the IMRT plans also took more time to deliver. The accuracy and deliverability of VMAT treatment plans were found to be substantially increased by limiting the number of monitor units (MU) per beam at the optimization stage, and thereby limiting beam modulation complexity. The VMAT arcs that were optimized with MU limitation had higher QA pass rates as well as higher modulation complexity scores (less complexity), lower modulation indices (less modulation), lower MU per beam, larger beam segments, and fewer small apertures than the VMAT arcs that were optimized without MU limitation. It is recommended that VMAT treatments for vertebral volumes, where the PTV abuts or surrounds the spinal cord, should be optimized with MU limitation. IMRT treatments may be preferable to the VMAT treatments, for dosimetry and deliverability reasons, but may be inappropriate for some patients because of their increased treatment delivery time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Early Results of Chimney Technique for Type B Aortic Dissections Extending to the Aortic Arch

ObjectiveTo summarize our early experience gained from the chimney technique for type B aortic dissection (TBAD) extending to the aortic arch and to evaluate the aortic remodeling in the follow-up period.MethodsFrom September 2011 to July 2014, 27 consecutive TBAD patients without adequate proximal landing zones were retrograde analyzed. Chimney stent-grafts were deployed parallel to the main endografts to reserve flow to branch vessels while extending the landing zones. In the follow-up period, aortic remodeling was observed with computed tomography angiography.ResultsThe technical success rate was 100 %, and endografts were deployed in zone 0 (n = 3, 11.1 %), zone 1 (n = 18, 66.7 %), and zone 2 (n = 6, 22.2 %). Immediately, proximal endoleaks were detected in 5 patients (18.5 %). During a mean follow-up period of 17.6 months, computed tomography angiography showed all the aortic stent-grafts and chimney grafts to be patent. Favorable remodeling was observed at the level of maximum descending aorta and left subclavian artery with expansion of true lumen (from 18.4 ± 4.8 to 25 ± 0.86 mm, p < 0.001 and 27.1 ± 0.62 to 28.5 ± 0.37 mm, p < 0.001) and depressurization of false lumen (from 23.7 ± 2.7 to 8.7 ± 3.8 mm, p < 0.001, from 5.3 ± 1.2 to 2.1 ± 2.1 mm, p < 0.001). While at the level of maximum abdominal aorta, suboptimal remodeling of the total aorta (from 24.1 ± 0.4 to 23.6 ± 1.5 mm, p = 0.06) and true lumen (from 13.8 ± 0.6 to 14.5 ± 0.4 mm, p = 0.08) was observed.ConclusionBased on our limited experience, the chimney technique with thoracic endovascular repair is demonstrated to be promising for TBAD extending to the arch with favorable aortic remodeling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Model based atomic resolution tomography

Electron tomography is a valuable three-dimensional characterization method, but the technique has so far been limited to a nanometer scale resolution, and therefore complementary two-dimensional structural analysis is generally performed using other techniques. In this paper, computer simulations of the latest transmission electron microscope technologies are performed on a CeO{sub 2} supercell to investigate the extension of electron tomography to the atomic scale resolution, from a tilt series of high resolution electron microscopy (HREM) images. We showed that high-voltage and aberration-corrected microscopes were both capable of retrieving adjacent oxygen and Ce atoms for a thickness up to 2.5 nm. In the case where only a few tilt angle projections are in zone-axis orientations, we introduced a hybrid tomography method, whereby a lattice-resolved tomogram obtained from a few zone-axis projections is combined with the external shape reconstruction of the crystal from binary projections. Finally, we discussed some experimental challenges related to the proposed HREM tomography technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nuclear Decontamination Evolution and Revolution - 20349

Decontamination, one of the oldest practices in the nuclear industry, is about to change. While no single approach to decontamination is appropriate in all situations, decontamination of highly contaminated surfaces is historically viewed as difficult and/or marginally effective and fixatives and strippable coatings are often called on to manage time sensitive contamination control issues. The deferral of proper decontamination can lead to accumulated concentrations of radioactive material increasing the risk of cross-contamination of workers and equipment while also increasing radiation levels, which further discourages decontamination. The results of the subject testing demonstrate that superior decontamination factors are readily achievable and the ALARA benefit of decontamination is viable through advanced decontamination technologies in conjunction with innovative application techniques. The collateral benefits will save countless radiological man-hours and personnel radiological exposure. The appropriate use of radiological decontamination techniques can prevent or limit the adverse effects of highly radioactive contamination in the work area. High levels of radiological contamination are typically associated with some of the most physically demanding work in the nuclear industry. Additionally, working in highly contaminated environments increases the risk of exposure to elevated levels of airborne radioactivity and radiation from the source term of the contamination, particularly in hard to reach areas or complex equipment. Veolia's Alaron Nuclear Services (Alaron), a fully integrated nuclear facility, has provided the nuclear industry waste treatment, consolidation, repackaging, and broad decontamination services for almost 35 years. In looking at solutions for its customers, as well as for their own facility, Alaron has recently collaborated with Environmental Alternatives, Inc. (EAI), which has provided innovative solutions addressing difficult nuclear decontamination and industrial cleaning challenges since 1989. This broad range of experience along with the products to support the work created an ideal partner for Alaron's needs at their facility. The benefits of collaboration were immediately recognizable to the management of both companies although the decontamination challenge was significant. Due to the nature of the services offered, contamination at the Alaron facility is routine. The recent decontamination experience at Alaron utilized an innovative surfactant process that quickly produces remarkably higher decontamination factors for both removable surface contamination and fixed contamination. Considering the time to decontaminate areas historically designated for high radiological hazard work, the results from this decontamination effort not only reduced contamination levels but also significantly lowered exposure rates in the working environment. The relative ease with which the surfactant is applied, combined with extraordinary decontamination test results, indicates the potential to alter current radiological work processes in a way that improves worker comfort, and removes radiological engineering barriers, allowing Alaron to complete complex radiological tasks more efficiently and effectively. In a series of two simple applications of the decontamination agent to contaminated high bay vertical surfaces, as well as a variety of horizontal and vertical surfaces with variable porousness and surface sealants, there was an overall reduction in removable contamination of approximately 73% with a reduction in area dose of approximately 93%. The results indicate additional reduction in fixed contamination with application of the surfactant. These values are much higher than experienced with more traditional decontamination agents. In conjunction with demonstrating EAI's surfactant on room surfaces, additional studies were conducted on complex geometry equipment including waste processing equipment, tools, and heavily contaminated parts normally handled from Alaron's customers. Evaluations were made with straight application of EAI's surfactant as well as adding additional techniques to the treatment which afforded revolutionary improvements in the levels of contamination removed. Successful decontamination with up to 95% reduction in removable contamination with just one application were demonstrated in several of the trials. This paper outlines the planned approach to use this technology, the variety of surfaces and equipment treated, and the results of the decontamination efforts. Furthermore, this paper discusses options for pretreatment of certain heavily contaminated equipment prior to employees handling and/or working with the equipment. The potential for dose saving and the reduced risk of cross-contamination with the added benefit of lower PPE requirements, produces an enormous potential for cost and time savings. Attendees will benefit from Alaron's experiences and more fully understand the capabilities of EAI's decontamination process. With the variety of contamination agents, forms and surfaces on which the technology was demonstrated, the information will be valuable to a broad cross-section of industry users. The significance of this report demonstrates superior decontamination factors are achievable utilizing the next evolution of decontamination technology and that the ALARA benefits of decontamination are available through advanced and modern decontamination efforts. The collateral benefits will save countless radiological man-hours and valuable personnel radiological exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

[Compton GRO Cycle 7]

The goals of this project were to use the improved location accuracy of combined BATSE/Ulysses-IPN gamma-ray burst (GRB) data to search for small-angle clustering within the burst population and to search for possible correlations between bursts and catalogs of known astrophysical objects. The research was completed in several phases due to the length of time needed to process the basic BATSE/Ulysses data and to develop the appropriate analysis algorithms. In the first phase, BATSE/Ulysses data were gathered from their respective sources and processed to yield, final BATSE burst catalog locations and final BATSE/Ulysses IPN timing annuli. The final data are published. In the next phase, traditional statistical analysis techniques were used to search a subset of the data for small-angle clustering and. correlations, and to produce upper limits. Next, the unique analysis techniques and software described in the proposal were developed and,applied to the final set of data (corresponding to the 4B catalog). The final search did not find any significant self-clustering or correlations with supernovae, AGN, or near by galaxy clusters. The investigation ruled-out earlier findings that indicated (with marginal significance) such results, and. provided stringent limits on the allowable fraction of bursts that are self-clustered and associated with selected known objects. An added benefit of this research came in 1998 when it was suggested that some gamma-ray bursts may be associated with supernova (SN) explosions. We responded rapidly and applied the tools of this investigation to study this possibility. Using combined BATSE/Ulysses data, we were able to completely rule out any association between bright bursts and known supernovae, thereby questioning the validity of any GRB/SN association. If a GRB/SN association exists, it must be only with a small fraction of weak bursts.

Kippen, R. Marc↗

Additive manufacturing of continuous carbon fiber-reinforced SiC ceramic composite with multiple fiber bundles by an extrusion-based technique

Due to the high cost, complex preparation process and difficulty in structural design, the traditional methods for carbon fiber-reinforced SiC ceramic composite preparation have great limitations. This paper presents a technique for the additive manufacturing multiple continuous carbon fiber bundle-reinforced SiC ceramic composite with core-shell structure using an extrusion-based technique. A conventional nozzle system was modified to print simultaneously a water-based SiC paste with continuous carbon fibers. Different levels of binder contents were investigated to optimize the stickiness, viscosity, thixotropy and viscoelasticity of the paste. After sintering, SiC whiskers were generated on the surface of fiber, which is conjectured to be due to the reaction between SiO and carbon fiber at high temperature. The continuous carbon fiber-reinforced SiC ceramic composite exhibited non-brittle fracture. In conclusion, the flexural strength of the additively manufactured Cf/SiC composites improved from 162 MPa with no fiber bundles to a maximum of 219 MPa with three fiber bundles.

36 MATERIALS SCIENCE↗

Use of Gas Adsorption and Inversion Methods for Shale Pore Structure Characterization

The analysis of porosity and pore structure of shale rocks has received special attention in the last decades as unconventional reservoir hydrocarbons have become a larger parcel of the oil and gas market. A variety of techniques are available to provide a satisfactory description of these porous media. Some techniques are based on saturating the porous rock with a fluid to probe the pore structure. In this sense, gases have played an important role in porosity and pore structure characterization, particularly for the analysis of pore size and shapes and storage or intake capacity. In this review, we discuss the use of various gases, with emphasis on N2 and CO2, for characterization of shale pore architecture. We describe the state of the art on the related inversion methods for processing the corresponding isotherms and the procedure to obtain surface area and pore-size distribution. The state of the art is based on the collation of publications in the last 10 years. Limitations of the gas adsorption technique and the associated inversion methods as well as the most suitable scenario for its application are presented in this review. Finally, we discuss the future of gas adsorption for shale characterization, which we believe will rely on hybridization with other techniques to overcome some of the limitations.

04 OIL SHALES AND TAR SANDS↗

Impact of Dilute DIO Additive on Local Microstructure of Fluorinated, pNDI‐Based Polymer Solar Cells

The performance of all‐polymer solar cells is often enhanced by incorporating solvent additives during solution processing. Here, in particular, blends based on the model all‐polymer system PBDBT:N2200 have been shown to have increased short‐circuit current and fill factor when processed with dilute diiodooctane (DIO). However, the morphological mechanism that drives the increase in performance is often not well understood due to limitations in common characterization techniques. In this study, it is shown that a combination of X‐ray techniques with cryogenic high‐resolution transmission electron microscopy (HRTEM) analysis can provide a quantitative and spatially resolved picture of polymer chain orientation and alignment in all‐polymer blends. It is found that DIO induces vertical phase separation in PBDBT‐2F:F‐N2200 and increases donor crystallite thickness in the pi‐stacking direction leading to an acceptor‐rich film surface. However, it is also shown that DIO does not disrupt the formation of face‐on donor–acceptor interfaces. These findings suggest that dilute DIO primarily affects crystalline domain formation in single component regions as opposed to mixed regions; thus, dilute DIO can impact vertical charge transport pathways without sacrificing donor–acceptor interfacial connectivity.

Cheng, Christina↗

Cell-Free Protein Synthesis for High-Throughput Biosynthetic Pathway Prototyping

Biological systems provide a sustainable and complimentary approach to synthesizing useful chemical products. Metabolic engineers seeking to establish economically viable biosynthesis platforms strive to increase product titers, rates, and yields. Despite continued advances in genetic tools and metabolic engineering techniques, cellular workflows remain limited in throughput. It may take months to test dozens of unique pathway designs even in a robust model organism, such as Escherichia coli. In contrast, cell-free protein synthesis enables the rapid generation of enzyme libraries that can be combined to reconstitute metabolic pathways in vitro for biochemical synthesis in days rather than weeks. Cell-free reactions thereby enable comparison of hundreds to thousands of unique combinations of enzyme homologs and concentrations, which can quickly identify the most productive pathway variants to test in vivo or further characterize in vitro. Furthermore, this cell-free pathway prototyping strategy provides a complementary approach to accelerate cellular metabolic engineering efforts toward highly productive strains for metabolite production.

59 BASIC BIOLOGICAL SCIENCES↗

Additively manufactured heat exchangers: a review on opportunities and challenges

Heat Exchangers (HXs) are crucial engineering components for thermal management. The broad range of applications and the current limits of traditional manufacturing techniques has directed designers and researchers to utilize additive manufacturing (AM) technologies to open a new chapter in HXs design and development. AM has created a world of opportunity to redesign HXs in pioneering forms, shapes, and sizes. In other words, AM technologies provides significant opportunities to increase surface area to volume ratio in heat transfer devices. On the other hand, there are certain challenges to overcome in order to fully grasp the benefits of AM technologies. This thorough review study is different from other published review as it intends to highlight the challenges and opportunities in design and manufacturing of HXs. In addition, part of this study is dedicated to investigate the experimental characterization of additively manufactured HXs. Furthermore, the significant details associated with experimental characterization are normally overlooked in review studies.

42 ENGINEERING↗

Outer Wall Segmentation of Abdominal Aortic Aneurysm by Variable Neighborhood Search Through Intensity and Gradient Spaces

Aortic aneurysm segmentation remains a challenge. Manual segmentation is a time-consuming process which is not practical for routine use. To address this limitation, several automated segmentation techniques for aortic aneurysm have been developed, such as edge detection-based methods, partial differential equation methods, and graph partitioning methods. However, automatic segmentation of aortic aneurysm is difficult due to high pixel similarity to adjacent tissue and a lack of color information in the medical image, preventing previous work from being applicable to difficult cases. This paper uses uses a variable neighborhood search that alternates between intensity-based and gradient-based segmentation techniques. By alternating between intensity and gradient spaces, the search can escape from local optima of each space. The experimental results demonstrate that the proposed method outperforms the other existing segmentation methods in the literature, based on measurements of dice similarity coefficient and jaccard similarity coefficient at the pixel level. In addition, it is shown to perform well for cases that are difficult to segment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An empirical investigation of organic software product lines

Abstract Software product line engineering is a best practice for managing reuse in families of software systems that is increasingly being applied to novel and emerging domains. In this work we investigate the use of software product line engineering in one of these new domains, synthetic biology. In synthetic biology living organisms are programmed to perform new functions or improve existing functions. These programs are designed and constructed using small building blocks made out of DNA. We conjecture that there are families of products that consist of common and variable DNA parts, and we can leverage product line engineering to help synthetic biologists build, evolve, and reuse DNA parts. In this paper we perform an investigation of domain engineering that leverages an open-source repository of more than 45,000 reusable DNA parts. We show the feasibility of these new types of product line models by identifying features and related artifacts in up to 93.5% of products, and that there is indeed both commonality and variability. We then construct feature models for four commonly engineered functions leading to product lines ranging from 10 to 7.5 × 10 20 products. In a case study we demonstrate how we can use the feature models to help guide new experimentation in aspects of application engineering. Finally, in an empirical study we demonstrate the effectiveness and efficiency of automated reverse engineering on both complete and incomplete sets of products. In the process of these studies, we highlight key challenges and uncovered limitations of existing SPL techniques and tools which provide a roadmap for making SPL engineering applicable to new and emerging domains.

97 MATHEMATICS AND COMPUTING↗

Planar measurements of soot volume fraction and OH in a JP-8 pool fire

The simultaneous measurement of soot volume fraction by laser induced incandescence (LII) and qualitative imaging of OH by laser induced fluorescence (LIF) was performed in a JP-8 pool fire contained in a 152 mm diameter pan. Line of sight extinction was used to calibrate the LII system in a laminar flame, and to provide an independent method of measuring average soot volume fraction in the turbulent flame. The presence of soot in the turbulent flame was found to be approximately 50% probable, resulting in high levels of optical extinction, which increased slightly through the flame from approximately 30% near the base, to approximately 50% at the tip. This high soot loading pushes both techniques toward their detection limit. Nevertheless, useful accuracy was obtained, with the LII measurement of apparent extinction in the turbulent flame being approximately 21% lower than a direct measurement, consistent with the influence of signal trapping. The axial and radial distributions of soot volume fraction are presented, along with PDFs of volume fraction, and new insight into the behavior of soot sheets in pool fires are sought from the simultaneous measurements of OH and LII. (author)

02 PETROLEUM↗

Adapting Optimal Velocity Tracking Control to Account for WEC Constraints and Power-Take-Off Efficiencies: Preprint

Wave energy converters (WECs) come in many different forms, from point absorbers, oscillating water columns, to bulge wave devices. This paper focuses on the control of point absorber WECs, which typically have a narrow-banded frequency response and, therefore, control is well placed to improve the energy capture of such WECs. The acausal nature of the control problem means that theoretically optimal control is almost impossible to achieve inpractice; however optimal velocity tracking (OVT) offers a simple and robust approximation to optimal control that can achieve better power capture than passive linear damping methods, albeit with necessarily higher force demands. OVT is a form of impedance matching and the magnitude of the power-take off (PTO) force demand is often not linearly proportional to the WEC velocity, which can lead to PTO force and speed combinations far from the optimalPTO efficiency. The highly non-linear PTO force and speed to efficiency mapping can, without remedial measures, severely diminish the effectiveness of OVT techniques. In this paper, limits to the movement and force of the PTO are demonstrated, allowing OVT to be more easily applied in practice. The effect of PTO efficiency is explored, and a potential solution to the problem of adapting control to account for efficiency is presented. Both aspects of the work presented highlight the requirement for co-design of the WEC, PTO, and controller.

conversion efficiency↗

Macro copper-graphene composites with enhanced electrical conductivity

Composites demonstrating simultaneously enhanced-electrical conductivity, current density and lowered-temperature coefficient of resistance (TCR) compared to copper have been highly sought after for their advantages in efficient energy transport behavior. While such conductors have been demonstrated in 1D (nanowires) and 2D (films) samples, achieving similar behavior in 3D has been challenging owing to the limitations of the synthesis techniques used. In this paper, novel macro-scale 3D copper conductors were demonstrated with simultaneously increased electrical conductivity and decreased temperature coefficient of resistance (TCR) through the addition of graphene. Hot-extrusion was used to manufacture over 1-m-long, 2-mm-diameter copper-graphene composites with varying graphene content and defect density. Results showed that the electrical conductivity and current density in composites with low defect density graphene increased monotonically as a function of graphene content. They also demonstrated a significant decrease of over 17% in TCR with the addition of only 15 ppm graphene along with over 52% improvement in current density. Comparatively composites with high defect density graphene demonstrated lower electrical conductivity and current density. This study provides first-of-its-kind evidence of 3D metal composites whose bulk electrical performance has been enhanced using graphene additive in minute quantities. Further developments in this area are essential to achieve high performance composite conductors that can improve energy transport efficiency and pave way for industrial adoption of such materials in the future.

36 MATERIALS SCIENCE↗