Search NASA⌕ Search

SEARCH · Search NASA

Results for “model reference control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Carbon dioxide, water vapor and methane soil efflux (soil respiration) in a Pinus palustris root exclusion in Georgetown, SC

This dataset contains processed data from a combination of survey flux chambers and long-term automated flux chambers. Soil flux measurements were conducted from June 2023 through December 2025 in a mature longleaf pine forest in Georgetown, SC. Soil respiration measurements were conducted approximately biweekly for two and a half years, before and after a root exclusion that took place on May 5, 2024. Processed, QAQC’d data for the treatment (root exclusion) and control (roots intact) before and after the root exclusion can be found in the file: 1_DATA_ESS_DOE_HR_RS_HB2_QAQC_Survey_Data_20260223.csv. Two multiday deployments were also conducted prior to the root exclusion using long-term automated chambers to continuously monitor greenhouse gas soil efflux. Processed, QAQC’d data for both long-term deployments can be found in the file: 2_DATA_ESS_DOE_HR_RS_HB2_QAQC_Longterm_Data_20260209.csv. Raw and working data files (.json, .81x, & .82z format) from LI-COR equipment are included for reference and can be accessed using SoilFluxPro software. CSV metadata files describe the raw data and modifications made using SoilFluxPro v5 and Matlab R2024b, as well as formatting and units for processed CSVs. Matlab code is included for reading in the processed CSVs, with sample figures comparing treatment and control. This research was performed as part of the project: “Improving models of stand and watershed carbon and water fluxes with more accurate representations of soil-plant-water dynamics in southern pine ecosystems”, which examines in part the effects hydraulic redistribution on soil efflux of carbon dioxide, water vapor and methane, as well as soil moisture and temperature in a southern pine ecosystem with sandy soils and high water table.

CARBON DIOXIDE FLUX↗

A model for helicopter guidance on spiral trajectories

A point mass model is developed for helicopter guidance on spiral trajectories. A fully coupled set of state equations is developed and perturbation equations suitable for 3-D and 4-D guidance are derived and shown to be amenable to conventional state variable feedback methods. Control variables are chosen to be the magnitude and orientation of the net rotor thrust. Using these variables reference controls for nonlevel accelerating trajectories are easily determined. The effects of constant wind are shown to require significant feedforward correction to some of the reference controls and to the time. Although not easily measured themselves, the controls variables chosen are shown to be easily related to the physical variables available in the cockpit.

Mendenhall, S.↗

Fuel penalties and time flexibility of 4D flight profiles under mismodeled wind conditions

A parametric sensitivity study was conducted to evaluate time flexibility and fuel penalties associated with 4D operations in the presence of mismodeled wind. The final cruise and descent segments of a flight in an advanced time-metered air traffic control environment were considered. Optimal performance of a B-737-100 airplane in known, constant winds was determined. Performance in mismodeled wind was obtained by tracking no-wind reference profiles in the presence of actual winds. The results of the analysis are presented in terms of loss of time flexibility and fuel penalties compared to the optimum performance in modeled winds.

Williams, David H.↗

Structural Acoustic Prediction and Interior Noise Control Technology

This report documents the results of Task 14, "Structural Acoustic Prediction and Interior Noise Control Technology". The task was to evaluate the performance of tuned foam elements (termed Smart Foam) both analytically and experimentally. Results taken from a three-dimensional finite element model of an active, tuned foam element are presented. Measurements of sound absorption and sound transmission loss were taken using the model. These results agree well with published data. Experimental performance data were taken in Boeing's Interior Noise Test Facility where 12 smart foam elements were applied to a 757 sidewall. Several configurations were tested. Noise reductions of 5-10 dB were achieved over the 200-800 Hz bandwidth of the controller. Accelerometers mounted on the panel provided a good reference for the controller. Configurations with far-field error microphones outperformed near-field cases.

Mathur, G. P.↗

Incorporation of Thermal Hydraulic Models for Thermal Power Dispatch into a PWR Power Plant Simulator

This report describes the development, modeling, and results of a generic pressurized water reactor power plant simulator that incorporates coupled electrical and thermal power dispatch to an industrial process located approximately one kilometer from the nuclear power plant. The simulator is a commercial PWR simulator that has been modified to include thermal power dispatch as described in past milestone reports [ , ]. The commercial PWR simulator is a generic simulator available from GSE SYSTEMS® (Sykesville, MD, USA) that is built using RELAP5-HDTM Real-Time Solution and in-house software developed by GSE Systems. This generic PWR (GPWR) simulator performs real-time simulation of the complete power plant from the reactor neutronics to the electricity generation and distribution. All primary, secondary, and auxiliary systems are modeled including all control logic in order to provide the most accurate representation of actual nuclear power plant (NPP) operation, and the simulator results have been rigorously verified by an actual NPP operating at approximately 1 GWe. This report is a continuation of worked performed in previous years, and supplemental information from previous reports is included in the appendix for reference.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantification of reactivity margin in BWR spent fuel pools

Boiling water reactor (BWR) spent fuel pool (SFP) criticality safety analyses typically use the in-core k{sub inf} criterion methodology to demonstrate margin to safety. This method models all the fuel in the SFP with a limiting lattice design at a peak reactivity just above a specific in-core k{sub inf} limit. To bound all the fuel in the pool and future fuel with reasonable margin, these limits are often set conservatively high compared to the peak reactivities of actual BWR bundle designs. When current regulatory expectations are met for the quantification of bias and uncertainty adders to the criticality analyses, some results are quantified that are close to the 0.95 in-rack reactivity limit required by 10CFR50.68. The small margins being calculated in the criticality safety analyses have resulted in concerns that SFPs have less margin to safety than was present in the past; however, inherent in the peak reactivity in-core k{sub inf} criterion methodology used to assess these margins is a very conservative model of the fuel. While it is known that all the fuel in a BWR SFP is typically burned well past its peak reactivity exposure, it has been unknown how much reactivity margin could be quantified if bundles were modeled more realistically by accounting for their actual discharge exposure profiles, operational void fractions, control histories, and depletion fuel temperatures. In this study, fuel bundles were depleted to their explicit nodal discharge exposure while accounting for actual operational conditions defined by GEH/GNF's core simulator code, PANACEA. The use of these depleted isotopics in the criticality safety analysis is commonly referred to as taking 'burn-up credit' in the analysis. This paper provides a quantification of the reactivity margin available from burn-up credit in two currently operating BWR spent fuel pools. The evaluation demonstrates that many of the bundles in these storage configurations are significantly below the in-rack reactivity limit, even with the necessary bias and uncertainty adders included. The utilization of BWR burnup credit appears to be an attractive solution to consider when evaluating options for reduced neutron absorber credit or for quantifying additional margin to the regulatory in-rack k{sub eff} limit. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Management of the decommissioning of the Thetis reactor

The Thetis research reactor on the site of the Nuclear Sciences Institute of the Ghent University has been in operation from 1967 until December 2003. This light-water moderated graphite-reflected low-enriched uranium pool-type reactor has been used for various purposes e.g. the production of radioisotopes and activation analyses. During the first years its core power was 15 kW. In the early '70, a core enlargement allowed for operation at typically 150 kW, while the maximum was allowed to be 250 kW In September 2007, Ghent University entrusted to SCK-CEN the management of the back-end of the spent fuel and the decommissioning of the reactor. In 2010, the spent fuel was removed from the reactor and transported to Belgoprocess for cementation in 400 l drums and interim storage awaiting final disposal. This activity allows tackling the decommissioning of the reactor. The objective is to complete its decommissioning by the end of 2014. In the framework of the decommissioning of the Thetis reactor, SCK-CEN set-up the final decommissioning plan and the decommissioning licensing file. These documents include among others a radiological inventory of the reactor. The graphite moderator blocks, the control and the safety pates, the liner of the pool were modeled to assess the activation products (isotopic vector and intensity). At the end of the unloading of the reactor in 2010 a brief mapping of the equipment's and internals of the reactor pool was performed. In 2012, we realized a more detailed mapping. These results confirmed those performed earlier and allowed to confirm the assumptions made in the final decommissioning plan. We set-up the terms of reference for the first decommissioning phase of the reactor namely the dismantling of the reactor i.e. reactor pool, circuits and rabbit system, equipment's and ventilation ducts. The removal of asbestos is also included into this phase. We conducted the selection process and the awarding of this decommissioning job. We gained the decommissioning license in May 2012. We also prepared the software tool allowing managing the decommissioning project by updating the inventory and recording the progress, the characterization measurements and the material and waste production. This software allows also to trace all the material streams and to report to the Authorities. This software is a simplified release of the ones developed by SCK-CEN in the framework of other decommissioning projects like BR3 and Belgonucleaire. The dismantling of the reactor i.e. reactor pool, circuits and rabbit system, will be performed in 2013. In 2014, it is planned to map all the surfaces of the infrastructure to highlight residual contamination of floor, walls and ceiling. The contaminated surfaces will be decontaminated and controlled. The objective is to reach the free release of the reactor building and laboratories by the end of 2014. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlling Intake of Uranium in the Workplace: Applications of Biokinetic Modeling and Occupational Monitoring Data

This report provides methods for interpreting and applying occupational uranium monitoring data. The methods are based on current international radiation protection guidance, current information on the chemical toxicity of uranium, and best available biokinetic models for uranium. Emphasis is on air monitoring data and three types of bioassay data: the concentration of uranium in urine; the concentration of uranium in feces; and the externally measured content of uranium in the chest. Primary Reference guidance levels for prevention of chemical effects and limitation of radiation effects are selected based on a review of current scientific data and regulatory principles for setting standards. Generic investigation levels and immediate action levels are then defined in terms of these primary guidance levels. The generic investigation and immediate actions levels are stated in terms of radiation dose and concentration of uranium in the kidneys. These are not directly measurable quantities, but models can be used to relate the generic levels to the concentration of uranium in air, urine, or feces, or the total uranium activity in the chest. Default investigation and immediate action levels for uranium in air, urine, feces, and chest are recommended for situations in which there is little information on the form of uranium taken into the body. Methods are prescribed also for deriving case-specific investigation and immediate action levels for uranium in air, urine, feces, and chest when there is sufficient information on the form of uranium to narrow the range of predictions of accumulation of uranium in the main target organs for uranium: kidneys for chemical effects and lungs for radiological effects. In addition, methods for using the information herein for alternative guidance levels, different from the ones selected for this report, are described.

59 BASIC BIOLOGICAL SCIENCES↗

Low-Speed Performance Enhancement Using Localized Active Flow Control: Localized Active Flow Control Simulations on a Reference Aircraft (2/4)

A study of the potential implementations of localized active flow control (AFC) technology onto future airplanes is presented. This collaborative investigation addresses key objectives of the NASA Advanced Air Transport Technology (AATT) Project, in terms of reduction in fuel consumption and lower emission. It specifically targets the goals set forth in a roadmap developed by the NASA/Boeing team. The roadmap is a result of a series of meetings held between the two parties over the years and it represents a shared vision for practical implementations, leading up to flight demonstrations of localized flow control. If successful, localized flow control may lead to important ramifications for next generation airplanes from both the economic and environmental perspectives. Under this contract localized AFC has been used to improve aerodynamic performance during high-lift operations using Computational Fluid Dynamics (CFD). Specifically, AFC has been applied at the aileron and at various location in the wing leading edge (LE) regions. The applications target reduced drag and enhanced lift over the range of practical angles of attack, including stall. These benefits translate to airplane performance improvements, such as longer range or larger payload. The CFD results are used to quantify potential aerodynamic benefits, as well as the input required for actuation. This helps identify the most promising candidates, which potentially provide material net airplane level enhancements using onboard fluidic sources. The airplane configuration selected for the CFD study is a representative of a future short/medium-range twin-engine airplane dubbed the Reference Aircraft. A slew of AFC applications has been explored and their aerodynamic performance enhancements were benchmarked against the baseline Reference Aircraft. Promising AFC candidates have been deemed practical and potentially suitable for both the aileron and the wing LE implementations. The findings on the Reference Aircraft are used to guide the development of the AFC-enhanced aileron for the CRM-HL. The wind-tunnel model of the CRM-HL will be used by NASA to validate the AFC concepts, complementing the CFD-based analysis and the integration study (final report document #3).

CFD↗

Modeling and Design of an Electro-Rheological Fluid Based Haptic System for Tele-Operation of Space Robots

For many years, the robotic community sought to develop robots that can eventually operate autonomously and eliminate the need for human operators. However, there is an increasing realization that there are some tasks that human can perform significantly better but, due to associated hazards, distance, physical limitations and other causes, only robot can be employed to perform these tasks. Remotely performing these types of tasks requires operating robots as human surrogates. While current "hand master" haptic systems are able to reproduce the feeling of rigid objects, they present great difficulties in emulating the feeling of remote/virtual stiffness. In addition, they tend to be heavy, cumbersome and usually they only allow limited operator workspace. In this paper a novel haptic interface is presented to enable human-operators to "feel" and intuitively mirror the stiffness/forces at remote/virtual sites enabling control of robots as human-surrogates. This haptic interface is intended to provide human operators intuitive feeling of the stiffness and forces at remote or virtual sites in support of space robots performing dexterous manipulation tasks (such as operating a wrench or a drill). Remote applications are referred to the control of actual robots whereas virtual applications are referred to simulated operations. The developed haptic interface will be applicable to IVA operated robotic EVA tasks to enhance human performance, extend crew capability and assure crew safety. The electrically controlled stiffness is obtained using constrained ElectroRheological Fluids (ERF), which changes its viscosity under electrical stimulation. Forces applied at the robot end-effector due to a compliant environment will be reflected to the user using this ERF device where a change in the system viscosity will occur proportionally to the force to be transmitted. In this paper, we will present the results of our modeling, simulation, and initial testing of such an electrorheological fluid (ERF) based haptic device.

Mavroidis, Constantinos↗

JAMES BUTTLE REVIEW: Interflow, subsurface stormflow and throughflow: A synthesis of field work and modelling

Interflow, throughflow and subsurface stormflow are interchangeable terms that refer to the lateral subsurface flow above a restricting layer of lower hydraulic conductivity that occurs during and following storm events. Interflow (used here) is a more dominant process in steeper catchments with high infiltration capacity soils overlying a more impermeable soil or geologic layer. Interflow as a runoff process was first recognised in the early 1900s, yet hydrologists still struggle to predict its occurrence, persistence, importance, interaction with other streamflow generation processes, and potential to connect to valleys and streams during and following storms. We review the history of interflow research and address some of the challenges in understanding its role in runoff production. We argue that characterising the controls on interflow initiation and occurrence relies on detailed field observations of subsurface properties, which exist only in limited experimental settings. This data shortcoming contributes to our inability to predict interflow or determine its contribution to streamflow more broadly. There remain many opportunities to advance our understanding of interflow that include both modelling and experimental or observational approaches in hydrology.

hillslope hydrology↗

Phase-controlled, heterodyne laser-induced transient grating measurements of thermal transport properties in opaque material

The methodology for a heterodyned laser-induced transient thermal grating technique for non-contact, non-destructive measurements of thermal transport in opaque material is presented here. Phase-controlled heterodyne detection allows us to isolate pure phase or amplitude transient grating signal contributions by varying the relative phase between reference and probe beams. The phase grating signal includes components associated with both transient reflectivity and surface displacement whereas the amplitude grating contribution is governed by transient reflectivity alone. By analyzing the latter with the two-dimensional thermal diffusion model, we extract the in-plane thermal diffusivity of the sample. Measurements on a 5 μm thick single crystal PbTe film yielded excellent agreement with the model over a range of grating periods from 1.6 to 2.8 μm. The measured thermal diffusivity of 1.3 × 10 -6 m 2 /s was found to be slightly lower than the bulk value.

36 MATERIALS SCIENCE↗

U.S. Department of Energy Reference Model Program RM1: Experimental Results.

The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing nonproprietary Reference Models (RM) of MHK technology designs as study objects for opensource research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN-SAFL). Reference Model 1 (RM1) is a 1:40 geometric scale dual-rotor axial flow horizontal axis device with counter-rotating rotors, each with a rotor diameter dT = 0.5m. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADVs) aligned with each rotor and the midpoint for RM1. Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Qw = 2.425m3s-1, resulting in a hub height velocity of approximately Uhub = 1.05ms-1 and blade chord length Reynolds numbers of Rec ≈ 3.0x105. Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing turbulence performance models and their ability to accurately predict device performance metrics, including computational fluid dynamics (CFD) models that can be used to predict turbulent inflow environments, reproduce wake velocity deficit, recovery and higher order turbulent statistics, as well as device performance metrics.

17 WIND ENERGY↗

The Radiative Forcing Model Intercomparison Project (RFMIP): Experimental protocol for CMIP6

The phrasing of the first of three questions motivating CMIP6 – “How does the Earth system respond to forcing?” – suggests that forcing is always well-known, yet the radiative forcing to which this question refers has historically been uncertain in coordinated experiments even as understanding of how best to infer radiative forcing has evolved. The Radiative Forcing Model Intercomparison Project (RFMIP) endorsed by CMIP6 seeks to provide a foundation for answering the question through three related activities: (i) accurate characterization of the effective radiative forcing relative to a near-preindustrial baseline and careful diagnosis of the components of this forcing; (ii) assessment of the absolute accuracy of clear-sky radiative transfer parameterizations against reference models on the global scales relevant for climate modeling; and (iii) identification of robust model responses to tightly specified aerosol radiative forcing from 1850 to present. Complete characterization of effective radiative forcing can be accomplished with 180 years (Tier 1) of atmosphere-only simulation using a sea-surface temperature and sea ice concentration climatology derived from the host model's preindustrial control simulation. Assessment of parameterization error requires trivial amounts of computation but the development of small amounts of infrastructure: new, spectrally detailed diagnostic output requested as two snapshots at present-day and preindustrial conditions, and results from the model's radiation code applied to specified atmospheric conditions. In conclusion, the search for robust responses to aerosol changes relies on the CMIP6 specification of anthropogenic aerosol properties; models using this specification can contribute to RFMIP with no additional simulation, while those using a full aerosol model are requested to perform at least one and up to four 165-year coupled ocean–atmosphere simulations at Tier 1.

54 ENVIRONMENTAL SCIENCES↗

Wind Tunnel Testing of High Efficiency Low Power (HELP) Actuation for Active Flow Control

A High Efficiency Low Power (HELP) methodology has been successfully developed and tested on an active flow control (AFC) version of the 10%-scale high-lift Common Research Model (CRM-HL) at the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel (14x22). The AFC variant of the CRM-HL, designated as CRM-SHL-AFC, was integrated with modular HELP actuator cartridges on the shoulder of its highly deflected (≥50°) simplehinged flaps. A reference conventional CRM-HL configuration equipped with Fowler flaps and a nacelle chine was chosen to provide the targeted lift enhancement goals and for comparison with the results of the CRM-SHL-AFC. The current data are presented with the Transonic Wall Interference Correction System (TWICS) method applied. The HELP actuators, which use a combination of unsteady sweeping jets and steady discrete jets in tandem, were designed to overcome strong adverse pressure gradients, while minimizing the pneumatic power usage. The power coefficient (C(sub π)), which takes account of both supply air pressure and mass flow usage for the AFC actuators, is a useful parameter for judging the actuators’ performance efficiency and perhaps for scaling-up of the AFC system. Full HELP actuation coverage with a constant spanwise nozzle pressure ratio (NPR) was able to achieve the lift enhancement goals for the entire lift curve and was found to be the most effective AFC case. For the most effective case, mass flow rates greater than ~0.91 lbm/s and NPR values greater than ~1.8 (corresponding to C(sub π) = 0.18) are needed to achieve the lift enhancement goal at α = 9°, whereas mass flow rates greater than ~1.23 lbm/s and NPR values greater than ~2.3 (corresponding to C(sub π) = 0.3) are needed to achieve the lift enhancement goal at α = 17°. Surface pressure distributions indicate that the HELP actuation on the flap shoulder increased the suction pressures (and flow circulation) globally in both the streamwise and the spanwise directions, and thereby enhanced the lift over the entire high-lift system. The CRM-SHLAFC configuration equipped with HELP actuation was able to match or exceed the lift performance of the reference conventional CRM-HL, thus meeting the objective of the research.

John C Lin↗

Procedure design of F and B operation and its impact on the risk of a nuclear power plant - 168

A feed and bleed (F and B) operation is an operator's emergency task to remove core heat from a reactor coolant system by bleeding coolant from the pressurizer, and feeding makeup water through safety injection systems under the loss of all feedwater condition. Even though the F and B operation is an important task having a significant impact on the risk of a nuclear power plant, there is a high uncertainty regarding its modeling and analysis in a PSA. This paper introduces a study on the design of an operational strategy for an F and B operation and its impact on the risk of a nuclear power plant in Korea. An intensive support analysis was conducted to understand the plant behavior and revise the success criteria for the HRA of the F and B operation. A human performance analysis on the emergency tasks was also conducted using a training simulator to generate the operator's performance time for the F and B operation. We revised the PSA model and updated the risk of the reference plant, which shows that the risk of the revised model is much higher than that of the existing model. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗