Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Growth condition dependence of photoluminescence polarization in (100) GaAs/AlGaAs quantum wells at room temperature

We conducted systematic measurements on the carrier lifetime (τ{sub c}), spin relaxation time (τ{sub s}), and circular polarization of photoluminescence (P{sub circ}) in (100) GaAs/AlGaAs multiple quantum wells grown by molecular beam epitaxy (MBE). The τ{sub c} values are strongly affected by MBE growth conditions (0.4–9 ns), whereas the τ{sub s} are almost constant at about 0.13 ns. The result suggests that spin detection efficiency [τ{sub s}/(τ{sub c} + τ{sub s})], which is expected to be proportional to a steady-state P{sub circ}, is largely dependent on growth condition. We confirmed that the P{sub circ} has similar dependence on growth condition to those of τ{sub s}/(τ{sub c} + τ{sub s}) values. The study thus indicates that choosing the appropriate growth condition of the QW is indispensable for obtaining a high P{sub circ} from a spin-polarized light-emitting diode (spin-LED)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A tunable path-separated electron interferometer with an amplitude-dividing grating beamsplitter

We demonstrate a tunable path-separated electron interferometer using a single amplitude-dividing beamsplitter to prepare multiple spatially isolated, coherent electron probe beams. We place four electrostatic bi-prisms in the optical column of a scanning transmission electron microscope (STEM) to achieve path separations of up to 25 μ m, the largest demonstrated within amplitude-division electron interferometers while maintaining fringe visibility of the directly observed interference fringes at the detector. We characterize the fringe visibility of this setup over a range of path separations and perform STEM holography to reconstruct the full object wave of a fabricated Si ramp test phase object. We report a quantitative object-wave measurement in this configuration and confirm with an independent off-axis electron holography measurement. This experimental design can potentially be applied to high-resolution phase imaging and fundamental physics experiments, such as an exploration of the electron wave packet coherence length and the Aharonov-Bohm effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nozzle geometry optimization for high-current aluminum ion beam acceleration via direct plasma injection scheme

We report the generation of a record aluminum ion beam current exceeding 58 mA at the Al 11+ charge state, accelerated to an energy of 5.5 MeV using the direct plasma injection scheme, which integrates a laser ion source (LIS) with a radio frequency quadrupole (RFQ) accelerator. The effect of nozzle geometry on beam extraction was systematically investigated using 8 and 12 mm tapered designs and an 18 mm cylindrical configuration. The 18 mm nozzle achieved the highest Al 11+ beam current, while the 12 mm aperture provided a favorable balance between beam intensity and current density. Beam extraction simulations confirmed effective RFQ matching across multiple charge states, and solenoidal field tuning further enhanced plasma collimation. This work not only establishes a new benchmark for high-current ion beam generation but also provides a fundamental understanding of plasma–beam interface dynamics crucial for the next generation of high-intensity particle accelerators, particularly those employing LIS-RFQ systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of correlated fragments in a sequence of images by superimposed Fourier holograms

The problem of detecting correlated fragments in a sequence of images recorded by the superimposing holograms within the Fourier holography scheme with angular multiplication of a spatially modulated reference beam is considered. The approach to the solution of this problem is based on the properties of the variance of the image sum. It is shown that this problem can be solved by providing a constant distance between the signal and reference images when recording superimposed holograms and a partial mutual correlatedness of reference images. The detection efficiency is analysed from the point of view of estimated image data capacity, the degree of mutual correlation of reference images, and the hologram recording conditions. The results of a numerical experiment under the most complicated conditions (representation of images by realisations of homogeneous random fields) confirm the theoretical conclusions. (holographic memory)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to test the coupling strength of the linear and nonlinear contributions to higher-order flow harmonics via event shape engineering

A Multi-Phase Transport (AMPT) model is used to study the efficacy of shape-engineered events to delineate the degree of coupling between the linear and nonlinear contributions to the higher-order flow harmonics v 4 and v 5 . Here, the study shows that the nonlinear contributions are strongly shape-dependent while the linear contributions are shape-independent, indicating little if any, coupling between the linear and nonlinear flow coefficients. The experimental verification of such patterns could be an invaluable tool for robust extraction of the linear and mode-coupled flow coefficients, especially for beam energies where the charged particle multiplicity and the event statistics precludes the use of current methods to establish the coupling strength.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving fast-ion confinement in high-performance discharges by suppressing Alfvén eigenmodes

Here, we show that the degradation of fast-ion confinement in steady-state DIII-D discharges is quantitatively consistent with predictions based on the effects of multiple unstable Alfven eigenmodes on beam-ion transport. Simulation and experiment show that increasing the radius where the magnetic safety factor has its minimum is effective in minimizing beam-ion transport. This is favorable for achieving high performance steady-state operation in DIII-D and future reactors. A comparison between the experiments and a critical gradient model, in which only equilibrium profiles were used to predict the most unstable modes, show that in a number of cases this model reproduces the measured neutron rate well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic evolution of ultracold electron beams from nanostructured cathodes

Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.

43 PARTICLE ACCELERATORS↗

Optical lattices as waveguides and beam splitters for atom interferometry: An analytical treatment and proposal of applications

We provide an analytical description of the dynamics of an atom in an optical lattice using the method of perturbative adiabatic expansion. A precise understanding of the lattice-atom interaction is essential to taking full advantage of the promising applications that optical lattices offer in the field of atom interferometry. One such application is the implementation of large momentum transfer (LMT) beam splitters that can potentially provide multiple order of magnitude increases in momentum space separations over current technology. We also propose interferometer geometries where optical lattices are used as waveguides for the atoms throughout the duration of the interferometer sequence. Such a technique could simultaneously provide a multiple order of magnitude increase in sensitivity and a multiple order of magnitude decrease in interferometer size for many applications as compared to current state-of-the-art atom interferometers.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electromagnetically induced conical emission

We describe theoretically a scheme for observing conical emission, a transverse nonlinear optical effect, in an atomic vapor with all excitation fields below the saturation level of the involved atomic transitions. The scheme relies on the giant Kerr nonlinearities possible under electromagnetically induced transparency to introduce a radially varying phase shift to a weak probe field by a weak signal field. The probe's far-field diffraction pattern shows multiple concentric rings around the probe beam's axis, characteristic of conical emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic prescription for optimal stimulated Raman transfer of ultracold heteronuclear molecules to the lowest rovibronic level

We show that the multiplicative product of a molecular-beam excitation spectrum and an ultracold-molecule excitation spectrum, with a frequency offset appropriate to the initial ultracold-molecule level, provides the relative rate of stimulated Raman transfer (SRT) from a given high rovibrational level to the lowest rovibronic level, i.e., the v{sup ''}=0,J{sup ''}=0 level of the ground electronic state for photoassociated (and magnetoassociated) ultracold molecules. This product spectrum clearly indicates the optimal pathways for SRT, even when the two component spectra are completely unassigned. We illustrate this specifically for the case of KRb.

74 ATOMIC AND MOLECULAR PHYSICS↗

Point group symmetry of cadmium arsenide thin films determined by convergent beam electron diffraction

Cadmium arsenide (Cd 3 As 2 ) is one of the first materials to be discovered to belong to the class of three-dimensional topological semimetals. Reported room-temperature crystal structures of Cd 3 As 2 differ subtly in the way the Cd vacancies are arranged within its antifluorite-derived structure, which determines if an inversion center is present and if Cd 3 As 2 is a Dirac or Weyl semimetal. Here, we apply convergent beam electron diffraction (CBED) to determine the point group of Cd 3 As 2 thin films grown by molecular-beam epitaxy. Using CBED patterns from multiple zone axes, high-angle annular dark-field images acquired in scanning transmission electron microscopy, and Bloch wave simulations, we show that Cd 3 As 2 belongs to the tetragonal 4/mmm point group, which is centrosymmetric. In conclusion, the results show that CBED can distinguish very subtle differences in the crystal structure of a topological semimetal, a capability that will be useful for designing materials and thin film heterostructures with topological states that depend on the presence of certain crystal symmetries.

36 MATERIALS SCIENCE↗

Fiber Front End With Multiple Phase Modulations and High-Bandwidth Pulse Shaping for High-Energy Laser-Beam Smoothing

The design and performance of a fiber front end delivering temporally shaped, phase-modulated optical pulses to a large-scale, high-energy laser system to demonstrate beam-smoothing concepts are presented.High-bandwidth LiNbO3 (lithium niobate) Mach--Zehnder modulators and arbitrary waveform generators temporally shape the power of the optical pulses. High-bandwidth, three-section LiNbO3 phase modulators precisely modulate the optical phase of the pulses at up to three microwave frequencies. Various calibration procedures and fail-safe systems are described. Sources of frequency-modulation-to-amplitude-modulation conversion, which can lead to unsafe operation of the high-energy laser system, are identified and compensated by amplitude and dispersion compensators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the Theory of the Modulation Instability in Optical Fiber and Laser Amplifiers

The modulation instability (MI) in optical fiber amplifiers and lasers with anomalous dispersion leads to CW beam breakup and the growth of multiple pulses. This can be both a detrimental effect, limiting the performance of amplifiers, and also an underlying physical mechanism in the operation of MI-based devices. Here we revisit the analytical theory of MI in fiber optical amplifiers. The results of the exact theory are compared with the previously used adiabatic approximation model, and the range of applicability of the latter is determined. The same technique is applicable to the study of spatial MI in solid state laser amplifiers and MI in non-uniform media.

42 ENGINEERING↗

Changes realized from extended bit-depth and metal artifact reduction in CT

Purpose: High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. Methods: Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc/Dosxyz (400 000 0000 histories, 6X, 10 Multiplication-Sign 10 cm{sup 2} beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%/2 mm. Results: For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 {+-} 56.6 and 13 588.5 {+-} 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was {approx}6.4% greater than 12-bit. Absolute film dosimetry in a region downstream of a stainless steel rod revealed that 16-bit calculated dose, with and without MAR, agreed more closely with film results (1%-2% less than film) as compared to 12-bit reconstructions (5.6%-6.5% less than film measurements). Gamma analysis revealed that 16-bit dose calculations were better matched to film results than 12-bit ({approx}10% higher pass rates for 16-bit). Similar results were observed in two patient cases; the largest discrepancy was observed for a femur case where 12-bit doses, both with and without MAR correction, were 6-7 Gy lower ({approx}17%-20% of the prescription dose) as compared to 16-bit dose calculations. However, when beams are not directly traversing metal, such as a prostate cancer case with bilateral hip prostheses; the impact of 16-bit reconstruction was diminished. Conclusions: These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster — Thur Eve — 46: Monte Carlo model of the Novalis Classic 6MV stereotactic linear accelerator using the GATE simulation platform

Monte Carlo (MC) simulation is accepted as the most accurate method to predict dose deposition when compared to other methods in radiation treatment planning. Current dose calculation algorithms used for treatment planning can become inaccurate when small radiation fields and tissue inhomogeneities are present. At our centre the Novalis Classic linear accelerator (linac) is used for Stereotactic Radiosurgery (SRS). The first MC model to date of the Novalis Classic linac was developed at our centre using the Geant4 Application for Tomographic Emission (GATE) simulation platform. GATE is relatively new, open source MC software built from CERN's Geometry and Tracking 4 (Geant4) toolkit. The linac geometry was modeled using manufacturer specifications, as well as in-house measurements of the micro MLC's. Among multiple model parameters, the initial electron beam was adjusted so that calculated depth dose curves agreed with measured values. Simulations were run on the European Grid Infrastructure through GateLab. Simulation time is approximately 8 hours on GateLab for a complete head model simulation to acquire a phase space file. Current results have a majority of points within 3% of the measured dose values for square field sizes ranging from 6×6 mm{sup 2} to 98×98 mm{sup 2} (maximum field size on the Novalis Classic linac) at 100 cm SSD. The x-ray spectrum was determined from the MC data as well. The model provides an investigation into GATE'S capabilities and has the potential to be used as a research tool and an independent dose calculation engine for clinical treatment plans.

60 APPLIED LIFE SCIENCES↗

Fast multipurpose Monte Carlo simulation for proton therapy using multi- and many-core CPU architectures

Purpose: Accuracy in proton therapy treatment planning can be improved using Monte Carlo (MC) simulations. However the long computation time of such methods hinders their use in clinical routine. This work aims to develop a fast multipurpose Monte Carlo simulation tool for proton therapy using massively parallel central processing unit (CPU) architectures. Methods: A new Monte Carlo, called MCsquare (many-core Monte Carlo), has been designed and optimized for the last generation of Intel Xeon processors and Intel Xeon Phi coprocessors. These massively parallel architectures offer the flexibility and the computational power suitable to MC methods. The class-II condensed history algorithm of MCsquare provides a fast and yet accurate method of simulating heavy charged particles such as protons, deuterons, and alphas inside voxelized geometries. Hard ionizations, with energy losses above a user-specified threshold, are simulated individually while soft events are regrouped in a multiple scattering theory. Elastic and inelastic nuclear interactions are sampled from ICRU 63 differential cross sections, thereby allowing for the computation of prompt gamma emission profiles. MCsquare has been benchmarked with the GATE/GEANT4 Monte Carlo application for homogeneous and heterogeneous geometries. Results: Comparisons with GATE/GEANT4 for various geometries show deviations within 2%–1 mm. In spite of the limited memory bandwidth of the coprocessor simulation time is below 25 s for 10{sup 7} primary 200 MeV protons in average soft tissues using all Xeon Phi and CPU resources embedded in a single desktop unit. Conclusions: MCsquare exploits the flexibility of CPU architectures to provide a multipurpose MC simulation tool. Optimized code enables the use of accurate MC calculation within a reasonable computation time, adequate for clinical practice. MCsquare also simulates prompt gamma emission and can thus be used also for in vivo range verification.

60 APPLIED LIFE SCIENCES↗

A unique signal of excited bosons in dijet data from pp collisions

With this note we would like to draw attention to a possible novel signal of new physics in dijet data at the hadron colliders. Usually it is accepted that almost all exotic models predict that these two jets populate the central (pseudo)rapidity region where y{sub 1,2} {approx_equal} 0. Contrary, the excited bosons do not contribute into this region, but produce an excess of dijet events over the almost flat QCD background in {chi} = exp vertical bar y{sub 1}-y{sub 2} vertical bar away from this region. For the special choice of parameters this could lead to a dip in the centrality ratio distribution over the dijet invariant mass instead of a bump, expected for the most exotic models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗