Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Synthesis, crystal structure, and optical properties of Ba{sub 2}Cu{sub 2}ThS{sub 5}, and electronic structures of Ba{sub 2}Cu{sub 2}ThS{sub 5} and Ba{sub 2}Cu{sub 2}US{sub 5}

The compound Ba{sub 2}Cu{sub 2}ThS{sub 5} has been synthesized by the reaction of BaS, S, Cu, and Th at 1173 K. It crystallizes in the monoclinic space group C{sub 2h}{sup 3}−C2/m with two formula units in a cell of dimensions a=13.5616(8) Å, b=4.1159(2) Å, c=9.3548(6) Å, β=115.89(1)° (100 K). The structure comprises Ba{sup 2+} cations and {sup 2}{sub ∞}[Cu{sub 2}ThS{sub 5}{sup 4−}] layers. The two dimensional layers are formed by the connection of ThS{sub 6} octahedra and CuS{sub 4} tetrahedra along [001] with a sequence…. oct tet tet oct tet tet…. Optical measurements performed on Ba{sub 2}Cu{sub 2}ThS{sub 5} indicate an indirect band gap of 1.86 eV. DFT calculations performed with the HSE06 functional yield band gaps of 1.7 eV for Ba{sub 2}Cu{sub 2}ThS{sub 5} and 1.5 eV for the isostructural compound Ba{sub 2}Cu{sub 2}US{sub 5}. - Graphical abstract: View of the Ba{sub 2}Cu{sub 2}ThS{sub 5} structure and its indirect band gap. DFT calculation gives 1.7 eV. Highlights: ► The new solid-state compound Ba{sub 2}Cu{sub 2}ThS{sub 5} has been synthesized from BaS, S, Cu, and Th at 1173 K. ► Single-crystal optical measurements indicate of indirect band gap of 1.86 eV for Ba{sub 2}Cu{sub 2}ThS{sub 5}. ► DFT with the HSE06 functional predict band gaps of 1.7 and 1.5 eV for Ba{sub 2}Cu{sub 2}ThS{sub 5} and Ba{sub 2}Cu{sub 2}US{sub 5}.

36 MATERIALS SCIENCE↗

Nanocomposite‐Seeded Epitaxial Growth of Single‐Domain Lithium Niobate Thin Films for Surface Acoustic Wave Devices

Epitaxial lithium niobate (LNO) thin films are an attractive material for devices across a broad range of fields, including optics, acoustics, and electronics. These applications demand high‐quality thin films without in‐plane growth domains to reduce the optical/acoustical losses and optimize efficiency. Twin‐free single‐domain‐like growth has been achieved previously, but it requires specific growth conditions that might be hard to replicate. In this work, a versatile nanocomposite‐seeded approach is demonstrated as an effective approach to grow single‐domain epitaxial lithium niobate thin films. Films are grown through a pulsed laser deposition method and growth conditions are optimized to achieve high‐quality epitaxial film. A comprehensive microstructure characterization is performed and optical properties are measured. A piezoelectric acoustic resonator device is developed to demonstrate the future potential of the nanocomposite‐seeded approach for high‐quality LNO growth for radio frequency (RF) applications.

36 MATERIALS SCIENCE↗

Generation of entangled coherent states for distant Bose-Einstein condensates via electromagnetically induced transparency

We propose a method to generate entangled coherent states between two spatially separated atomic Bose-Einstein condensates (BECs) via the technique of electromagnetically induced transparency (EIT). Two strong coupling laser beams and two entangled probe laser beams are used to cause two distant BECs to be in EIT states and to generate an atom-photon entangled state between probe lasers and distant BECs. The two BECs are initially in unentangled product coherent states while the probe lasers are initially in an entangled state. Entangled states of two distant BECs can be created through the performance of projective measurements upon the two outgoing probe lasers under certain conditions. Concretely, we propose two protocols to show how to generate entangled coherent states of the two distant BECs. One is a single-photon scheme in which an entangled single-photon state is used as the quantum channel to generate entangled distant BECs. The other is a multiphoton scheme where an entangled coherent state of the probe lasers is used as the quantum channel. Additionally, we also obtain some atom-photon entangled states of particular interest such as entangled states between a pair of optical Bell states (or quasi-Bell-states) and a pair of atomic entangled coherent states (or quasi-Bell-states)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light propagation in a neutron detector based on 6 Li glass scintillator particles in an organic matrix

Composite materials consisting of 6 Li scintillator particles in an organic matrix can enable thermal neutron detectors with excellent rejection of gamma-ray backgrounds. The efficiency of transporting scintillation light through such a composite is critical to the detector performance. This optical raytracing study of a composite thermal neutron detector quantifies the various sources of scintillation light loss and identifies favorable photomultiplier tube (PMT) readout schemes. The composite material consisted of scintillator cubes within an organic matrix shaped as a right cylinder. The cylinder surface was surrounded by an optical reflector, and the light was detected by PMTs attached to the cylinder end faces. A reflector in direct contact with the composite caused 53% loss of scintillation light. This loss was reduced 8-fold by creating an air gap between the composite and the reflector to allow a fraction of the scintillation light to propagate by total internal reflection. Replacing a liquid mineral oil matrix with a solid acrylic matrix decreased the light transport efficiency by only ~10% for the benefit of creating an all-solid-state device. The light propagation loss was found to scale exponentially with the distance between the scintillation event and the PMT along the cylinder main axis. This enabled a PMT readout scheme that corrects for light propagation loss on an event-by-event basis and achieved a 4.0% energy resolution that approached Poisson-limited performance. These results demonstrate that composite materials can enable practical thermal neutron detectors for a wide range of nuclear non-proliferation and safeguard applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructural and preliminary optical and microwave characterization of erbium-doped CaMoO 4 thin films

This work explores erbium-doped calcium molybdate (Er:CaMoO4) thin films grown on silicon and yttria stabilized zirconia (YSZ) substrates, as a potential solid state system for C-band (utilizing the ∼1.5 μm Er 3+ 4f–4f transition) quantum emitters for quantum network applications. Through molecular beam epitaxial growth experiments and electron microscopy, X-ray diffraction, and reflection electron diffraction studies, we identify an incorporation limited deposition regime that enables a 1:1 Ca:Mo ratio in the growing film leading to single phase CaMoO 4 formation that can be in situ doped with Er (typically 2–100 ppm). We further show that growth on silicon substrates is single phase but polycrystalline in morphology, while growth on YSZ substrates leads to high-quality epitaxial single crystalline CaMoO 4 films. We perform preliminary optical and microwave characterization on the suspected Y 1 –Z 1 transition of 2 ppm, 200 nm epitaxial Er:CaMoO 4 annealed thin films and extract an optical inhomogeneous linewidth of 9.1(1) GHz, an optical excited state lifetime of 6.7(2) ms, a spectral diffusion-limited homogeneous linewidth of 6.7(4) MHz, and an EPR linewidth of 1.10(2) GHz.

Masiulionis, Ignas [Univ. of Chicago, IL (United S↗

Echo-Enabled Harmonic Generation for Seeded FELs

In the x-ray wavelengths, the two leading FEL concepts are the self-amplified spontaneous emission (SASE) configuration and the high-gain harmonic generation (HGHG) scheme. While the radiation from a SASE FEL is coherent transversely, it typically has rather limited temporal coherence. Alternatively, the HGHG scheme allows generation of fully coherent radiation by up-converting the frequency of a high-power seed laser. However, due to the relatively low up-frequency conversion efficiency, multiple stages of HGHG FEL are needed in order to generate x-rays from a UV laser. The up-frequency conversion efficiency can be greatly improved with the recently proposed echo-enabled harmonic generation (EEHG) technique. In this work we will present the concept of EEHG, and address some practically important issues that affect the performance of the seeding. We show how the EEHG can be incorporated in the FEL scheme and what is the expected performance of the EEHG seeded FEL. We will then briefly describe the first proof-of-principle EEHG experiment carried out at the Next Linear Collider Test Accelerator (NLCTA) at SLAC. We will also discuss latest advances in the echo-scheme approach, and refer to subsequent modifications of the original concept.

43 PARTICLE ACCELERATORS↗

Performance measurement results for a 220 Mbps QPPM optical communication receiver with an EG/G Slik APD

The performance of a 220 Mbps quaternary pulse position modulation (QPPM) optical communication receiver with a 'Slik' silicon avalanche photodiode (APD) and a wideband transimpedance preamplifier in a small hybrid circuit module was measured. The receiver performance had been poor due to the lack of a wideband and low noise transimpedance preamplifier. With the new APB preamplifier module, the receiver achieved a bit error rate (BER) of 10 exp -6 at an average received input optical signal power of 4.2 nW, which corresponds to an average of 80 received (incident) signal photons per information bit.

Davidson, Frederic M.↗

Dynamic Characterizations of an 8-frame Half-Strip High-speed X-ray Microchannel Plate Imager

High-speed microchannel plate (MCP)–based imagers are critical detectors for x-ray diagnostics employed on Z-experiments at Sandia National Laboratories (SNL) to measure time-resolved x-ray spectra and to image dynamic hohlraums. A multiframe design using eight half strips in one imager permits recordings of radiation events in discrete temporal snapshots to yield a time-evolved movie. We present data using various facilities to characterize the performance of this design. These characterization studies include DC and pulsed-voltage biased measurements in both saturated and linear operational regimes using an intense, short-pulsed UV laser. Electrical probe measurements taken to characterize the shape of the HV pulse propagating across the strips help to corroborate the spatial gain dependence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A wide variety of injection molding technologies is now applicable to small series and mass production

Micro plastic parts open new fields for application, e. g., to electronics, sensor technologies, optics, and medical engineering. Before micro parts can go to mass production, there is a strong need of having the possibility for testing different designs and materials including material combinations. Hence, flexible individual technical and technological solutions for processing are necessary. To manufacture high quality micro parts, a micro injection moulding machine named formicaPlast based on a two-step plunger injection technology was developed. Resulting from its design, the residence time and the accuracy problems for managing small shot volumes with reproducible high accuracy are uncompromisingly solved. Due to their simple geometry possessing smooth transitions and non adherent inner surfaces, the plunger units allow to process 'all' thermoplastics from polyolefines to high performance polymers, optical clear polymers, thermally sensitive bioresorbables, highly filled systems (the so-called powder injection molding PIM), and liquid silicon rubber (LSR, here with a special kit). The applied platform strategy in the 1K and 2K version allows integrating automation for assembling, handling and packaging. A perpendicular arrangement allows encapsulation of inserts, also partially, and integration of this machine into process chains. Considering a wide variety of different parts consisting of different materials, the high potential of the technology is demonstrated. Based on challenging industrial parts from electronic applications (2K micro MID and bump mat, where both are highly structured parts), the technological solutions are presented in more detail.

36 MATERIALS SCIENCE↗

ChemCam on MSL 2009: first laser induced breakdown spectrometer for space science

ChemCam is one of the 10 instrument suites on the Mars Science Laboratory, a martian rover being built by Jet Propulsion Laboratory, for the next NASA mission to Mars (MSL 2009). ChemCam is an instrument package consisting of two remote sensing instruments: a Laser-Induced Breakdown Spectrometer (LIBS) and a Remote Micro-Imager (RMI). LIBS provides elemental compositions of rocks and soils, while the RMI places the LIBS analyses in their geomorphologic context. Both instruments rely on an autofocus capability to precisely focus on the chosen target, located at distances from the rover comprised between 1 and 9 m for LIBS, and 2 m and infinity for RMI. ChemCam will help determine which samples, within the vicinity of the MSL rover, are of sufficient interest to use the contact and in-situ instruments for further characterization. It will provide valuable analyses of samples that are inaccessible to contact and in-situ instruments, and of a much larger number of samples than can be done with this kind of instrument. ChemCam also has a capability to provide passive spectroscopy data of rocks and soils on Mars. ChemCam hardware consists of a Mast Unit (MU), provided by France, and a Body Unit (BU) built and tested in the USA. The Flight Model of the MU is assembled, tested and now available in the USA, while the BU is currently being assembled and tested. Both will be connected by the end of year '08 for end-to-end functional and performance tests, before delivery to JPL and assembly on the MSL rover. Launch is scheduled for October 09. After describing the concept of ChemCam, this presentation focuses on its French part, Mast Unit. The results presented show that Mast Unit is able to generate a plasma and collect its light, over the full applicable ranges of distances and temperatures on Mars.

47 OTHER INSTRUMENTATION↗

Array of virtual Frisch-grid CZT detectors with common cathode readout and pulse-height correction

We present our new results from testing 15-mm-long virtual Frisch-grid CdZnTe detectors with a common-cathode readout for correcting pulse-height distortions. The array employs parallelepiped-shaped CdZnTe (CZT) detectors of a large geometrical aspect ratio, with two planar contacts on the top and bottom surfaces (anode and cathode) and an additional shielding electrode on the crystal's sides to create the virtual Frisch-grid effect. We optimized the geometry of the device and improved its spectral response. We found that reducing to 5 mm the length of the shielding electrode placed next to the anode had no adverse effects on the device's performance. At the same time, this allowed corrections for electron loss by reading the cathode signals to obtain depth information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

Simulation Analysis of Mode Hopping Impacts on OFDR Sensing Performance

This article examines the impacts of mode hopping on the sensing performance of optical frequency domain reflectometry (OFDR) and explores the potential for developing economical OFDR interrogators employing low-cost distributed feedback (DFB) lasers. By conducting numerical simulations, this study reveals that mode hopping has minimal effects on distance sensing measurements in free space due to the limited duration of beat interference signal at the incorrect frequency within the coherence length. Additionally, the simulations indicate that mode hopping only slightly affects the distributed strain sensing of OFDR, resulting in an error range of less than ±1µε when 100µε is applied to the sensing fiber. These findings highlight the potential of using low-cost DFB lasers with a 1-nm wavelength sweep range and a 1-MHz linewidth as tunable laser sources in OFDR while maintaining reliable and accurate sensing performance.

Wang, Qirui (ORCID:0000000336532984)↗

Effects On Beam Alignment Due To Neutron-Irradiated CCD Images At The National Ignition Facility

The 192 laser beams in the National Ignition Facility (NIF) are automatically aligned to the target-chamber center using images obtained through charged coupled device (CCD) cameras. Several of these cameras are in and around the target chamber during an experiment. Current experiments for the National Ignition Campaign are attempting to achieve nuclear fusion. Neutron yields from these high energy fusion shots expose the alignment cameras to neutron radiation. The present work explores modeling and predicting laser alignment performance degradation due to neutron radiation effects, and demonstrates techniques to mitigate performance degradation. Camera performance models have been created based on the measured camera noise from the cumulative single-shot fluence at the camera location. We have found that the effect of the neutron-generated noise for all shots to date have been well within the alignment tolerance of half a pixel, and image processing techniques can be utilized to reduce the effect even further on the beam alignment.

42 ENGINEERING↗

Characterization Studies and Performance of Half-strip High-speed X-ray Microchannel Plate Imager

High-speed microchannel plate (MCP)–based imagers are critical detectors for x-ray diagnostics employed on Z-experiments at Sandia National Laboratories (SNL) to measure time-resolved x-ray spectra and to image dynamic hohlraums. A design using eight half-strip x-ray photocathodes in one imager permits recordings of radiation events in discrete temporal snapshots to yield a time-evolved movie. We present data using various facilities to characterize the performance of this design. These characterization studies include DC and pulsed-voltage biased measurements in both saturated and linear operational regimes using an intense, short-pulsed UV laser and Manson source. Surface voltage profile measurements using a picoprobe help to determine the gain variation across the strips. Test data from a recent SNL ZR-experiment demonstrates the flexibility and high-quality images obtained by this MCP imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

Results of Recent Microstructural Characterization of Irradiated U-Mo Dispersion Fuels with Al Alloy Matrices that Contain Si

RERTR U-Mo dispersion fuel plates are being developed for application in research reactors throughout the world. As part of this development, reactor experiments are being conducted in the Advanced Test Reactor to determine the irradiation performance of different dispersion fuels that contain U-Mo alloys with different Mo contents and Al alloy matrices with different Si contents. Of particular interest is the performance of the dispersion fuels depending on the Si content of the Al alloy matrix, since the addition of Si is being looked to for improving the performance of these dispersion fuels. This paper will describe the results of recent microstructural examinations that have been performed using optical metallography and scanning electron microscopy on as-fabricated and as-irradiated dispersion fuels with different amounts of Si added to the Al matrix. Differences in the microstructural development during irradiation as a function of the Si content in the Al matrix will be discussed, and comments will be made about the development and stability of the fuel/matrix interaction layers that are commonly present in irradiated dispersion fuels.

99 GENERAL AND MISCELLANEOUS↗