Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

On-orbit Performance of MODIS Solar Diffuser Stability Monitor

MODIS has 20 reflective solar bands (RSBs) in the visible (VIS), near-infrared (NIR) , and shortwave infrared (SWIR) spectral regions. MODIS RSBs are calibrated on-orbit by a solar diffuser (SD) with its on-orbit degradation tracked by a solar diffuser stability monitor (SDSM). The SDSM is an instrument by itself, consisting of a solar integration sphere (SIS) with 9 individual filtered detectors covering wavelengths from 0.41 to 0.94 micrometers. It functions as a ratioing radiometer with alternate observations made of the direct sunlight (Sun view) and that diffusely reflected from the SD panel (SD view) during each scheduled SD/SDSM calibration event. Since launch, Terra and Aqua MODIS and their SDSM have successfully operated for more than 12 and 10 years, respectively. The VIIRS, on-board the newly launched Suomi National Polar orbiting Partnership (NPP) spacecraft, has been designed and built with strong MODIS heritage and carries a similar and improved SD and SDSM calibration system. This paper provides an overview of SDSM design functions, its on-orbit calibration strategies and performance for both Terra and Aqua MODIS missions. Discussions of its on-orbit performance are focused on changes in SDSM detector responses over time and their impact on tracking SD on-orbit degradation. Also presented in this paper are lessons learned from MODIS SDSM and improvements made for the VIIRS SDSM, and preliminary comparisons of their on-orbit performance.

Xiong, Xiaoxiong↗

Spectral Effects in Albedo and Rearside Irradiance Measurement for Bifacial Performance Estimation

We investigate the impact of spectral dependence of ground surface reflectivity on albedo and rearside irradiance measurements necessary for bifacial photovoltaic (PV) module performance estimation and monitoring. Because PV modules are spectrally selective, albedo and irradiance measurements performed with common irradiance sensors may require spectral mismatch corrections when used for performance prediction. We investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystalline silicon PV reference cells in comparison to a typical crystalline-silicon bifacial PV module. Simulations are performed for nine different representative ground surface materials using simulated solar spectra together with spectral reflectivity data distributed with the SMARTS simulation software. For the materials considered, the results show that albedo spectral mismatch relative to the bifacial module is distributed over a range of ±9.2% for thermopile pyranometers versus only ±3.7% for a typical PV reference cell. We consider the impact of this spectrally-responsive albedo mismatch on bifacial PV module rearside irradiance measurements. Using synthesized rearside spectral irradiance distributions, we find that for the nine different ground surface materials the predicted rearside irradiance measurement deviates from the effective irradiance observed by the PV module by on the order of 16.5 W/m 2 for the pyranometer and 3.6 W/m 2 for the PV reference cell. We discuss the implications for bifacial albedo and irradiance measurement.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Effects of misalignment on mechanical behavior of metals in creep

Creep tests were conducted by means of a closed loop servocontrolled materials test system. The strain history prior to creep is carefully monitored. Tests were performed for aluminum alloy 6061-O at 150 C and were monitored by a PDP 11/04 minicomputer at a preset constant plastic strain rate prehistory. The results show that the plastic strain rate prior to creep plays a significant role in creep behavior. The endochronic theory of viscoplasticity was applied to describe the observed creep curves. Intrinsic time and strain rate sensitivity function concepts are employed and modified according to the present observation.

Wu, H. C.↗

Flight Test of Propulsion Monitoring and Diagnostic System

The objective of this program was to perform flight tests of the propulsion monitoring and diagnostic system (PMDS) technology concept developed by Honeywell under the NASA Advanced General Aviation Transport Experiment (AGATE) program. The PMDS concept is intended to independently monitor the performance of the engine, providing continuous status to the pilot along with warnings if necessary as well as making the data available to ground maintenance personnel via a special interface. These flight tests were intended to demonstrate the ability of the PMDS concept to detect a class of selected sensor hardware failures, and the ability to successfully model the engine for the purpose of engine diagnosis.

Gabel, Steve↗

Advanced focusing system for secondary electrons in a bunch shape monitor

Non-destructive measurements of longitudinal beam profile in non-relativistic hadron accelerators are usually performed with Bunch Shape Monitors that utilize secondary electron emission to reproduce the shape of a primary ion beam. The existing devices, however, have poor electron collection efficiency from the wire and are limited to one dimensional measurements of the phase coordinate. Here, we present the development of a bunch shape monitor with improved performance for proton beams to be used in the Spallation Neutron Source accelerator. This improvement was achieved by adding focusing optics between the wire and the entrance slit, which will also allow measurements over a much higher dynamic range. Here we present the design, simulation and experimental test results of the developed new electron beam guidance system for the existing SNS bunch shape monitor that allowed significant improvement in the collection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-I-61: Assessment and Characterization of the Built-in Internal Photometer of Primary Diagnostic Monitors

Purpose: The conformance of Primary Diagnostic Monitors (PDMs) to the DICOM GSDF is increasingly required by several state and city regulators. Our purpose was to quantitatively characterize the luminance performance of the internal, built in photometer of BARCO monitors against an externally calibrated luminance meter. Methods: Thirty one PDMs (BARCO) were included in our analysis. An externally calibrated photometer (RaySafe Solo Light) was used to measure the luminance and illuminance values. Measured monitors were located at various hospital sites, radiology physicians’ offices and radiology reading rooms. All measured PDMs were equipped with the manufacturer’s built-in photometers and connected to Barco MediCal QA web service for manual and automatic quality control measurements. PDM combinations included 1, 2 and 4 monitors depending on the location. TG-18 and SMPTE test patterns were used to evaluate monitor performance. Results: All the PDMs exceeded the luminance ratio of 250:1, as required by NYC PDM guidelines. One PDM failed the NYC requirement for the minimal luminance level of 350 cd/m2. As compared to the external photometer, the difference in measurement of the maximum luminance with the built-in photometer was found to exceed 5% on 6 of the PDM measured, with a maximum deviation of 10%. The age of the monitors that failed was on average 5 years. All monitors passed the luminance uniformity test, which was 30% from the center of the monitor to the 4 corner locations. Four PDMs failed the Gray Scale Display Function (GSDF) calibration. Conclusion: For the consistent display of medical images and continued conformance with the DICOM GSDF standard, it is essential to compare the performance of the built-in photometer with an externally calibrated photometer for monitors that are older than 5 years.

60 APPLIED LIFE SCIENCES↗

Indoor and Outdoor Test Results for 'DUSST', a Low-Cost, Low-Maintenance PV Soiling Sensor

Soiling can cause significant losses to photovoltaic systems, and therefore it is often measured for the purposes of predicting long-term energy forecasts or for monitoring real time performance and triggering maintenance events as needed. Currently, the most common soiling monitoring technologies are soiling stations that use the electrical outputs of a regularly cleaned PV device and of a naturally soiled PV device to quantify soiling. As part of a new class of low-cost and low-maintenance soiling stations NREL has previously presented 'DUSST'. DUSST projects a collimated monochromatic light source through a glass surface (exposed similarly to the PV modules that need to be monitored) and on to a light detector to measure the intensity of the transmitted light. As the glass surface naturally soils, the losses are quantified by comparing this soiled reading with a calibrated reading under baseline clean condition. This work presents the ongoing improvement of DUSST and the ongoing indoor and outdoor validation of this new soiling sensor.

14 SOLAR ENERGY↗

The Limb Infrared Monitor of the Stratosphere - Experiment description, performance, and results

An experiment and results, using a six-channel infrared radiometer aboard the Nimbus 7 spacecraft to sound the composition and structure of the middle atmosphere, are described. The measurement requirements are discussed, and critical instrument parameters are identified. Next, the instrument and its laboratory calibration are described. Temperature accuracy and precision are estimated to be 2 K and about 0.4 K respectively. Accuracy of the trace gas measurements is about 25 percent, comparable to the estimated accuracy of the in situ comparison data; their precision is about 0.25 ppmv for ozone and water vapor and 0.2 ppbv for nitric acid and nitrogen dioxide. Examples of the vertical profiles, maps, and cross sections of the data show previously unobserved variations with latitude, altitude, and time. The results demonstrate that infrared limb scanning is an extremely powerful method for sounding the middle atmosphere.

Gille, J. C.↗

The role of psychologists in future spaceflight

The need for psychologists to have a more active role in planning space missions is discussed. It is suggested that it would be beneficial if psychologists conducted research aimed at optimizing the organization, composition, and performance of crews; participated in the selection and training of crews; and monitored the actual performance and adjustment of crews during missions. The areas which require further research and the types of research strategies to be implemented are described. The desirable traits for future space personnel and the role of psychologists in mission control are examined.

Helmreich, Robert L.↗

Cognitive Performance in Operational Environments

Optimal cognition during complex and sustained operations is a critical component for success in current and future military operations. "Cognitive Performance, Judgment, and Decision-making" (CPJD) is a newly organized U.S. Army Medical Research and Materiel Command research program focused on sustaining operational effectiveness of Future Force Warriors by developing paradigms through which militarily-relevant, higher-order cognitive performance, judgment, and decision-making can be assessed and sustained in individuals, small teams, and leaders of network-centric fighting units. CPJD evaluates the impact of stressors intrinsic to military operational environments (e.g., sleep deprivation, workload, fatigue, temperature extremes, altitude, environmental/physiological disruption) on military performance, evaluates noninvasive automated methods for monitoring and predicting cognitive performance, and investigates pharmaceutical strategies (e.g., stimulant countermeasures, hypnotics) to mitigate performance decrements. This manuscript describes the CPJD program, discusses the metrics utilized to relate militarily applied research findings to academic research, and discusses how the simulated combat capabilities of a synthetic battle laboratory may facilitate future cognitive performance research.

Russo, Michael↗

Predictive Modeling and Operational Monitoring of Starlink Leo Satellite Network Performance in Maritime Environments

This thesis investigates short-term performance prediction for maritime LEO operational planning and application performance cannot anticipate available bandwidth or communication delay, which complicates variation alter signal conditions over short time scales. As a result, maritime users often fluctuations in link quality. In addition, Frequent satellite handoffs and Doppler-induced rapid satellite movement and changing atmospheric conditions cause substantial unavailable. Despite their availability, reliable operation at sea remains difficult because broadband connectivity in maritime regions where terrestrial infrastructure in

97 MATHEMATICS AND COMPUTING↗

Experimental Validation of a Resilient Monitoring and Control System

Complex, high performance, engineering systems have to be closely monitored and controlled to ensure safe operation and protect public from potential hazards. One of the main challenges in designing monitoring and control algorithms for these systems is that sensors and actuators may be malfunctioning due to malicious or natural causes. To address this challenge, this paper addresses a resilient monitoring and control (ReMAC) system by expanding previously developed resilient condition assessment monitoring systems and Kalman filter-based diagnostic methods and integrating them with a supervisory controller developed here. While the monitoring and diagnostic algorithms assess plant cyber and physical health conditions, the supervisory controller selects, from a set of candidates, the best controller based on the current plant health assessments. To experimentally demonstrate its enhanced performance, the developed ReMAC system is then used for monitoring and control of a chemical reactor with a water cooling system in a hardware-in-the-loop setting, where the reactor is computer simulated and the water cooling system is implemented by a machine condition monitoring testbed at Idaho National Laboratory. Results show that the ReMAC system is able to make correct plant health assessments despite sensor malfunctioning due to cyber attacks and make decisions that achieve best control actions despite possible actuator malfunctioning. Monitoring challenges caused by mismatches between assumed system component models and actual measurements are also identified for future work.

97 MATHEMATICS AND COMPUTING↗

Testing and Performance Validation of a Shielded Waste Segregation and Clearance Monitor Designed for the Measurement of Low Level Waste-13043

This paper describes the development, testing and validation of a shielded waste segregation and clearance monitor designed for the measurement of low-density low-level waste (LLW). The monitor is made of a measurement chamber surrounded by detectors and a shielded outer frame. The shielded chamber consists of a steel frame, which contains typically 1.5 inches (3.81 cm) of lead and 0.5 inches (1.27 cm) of steel shielding. Inside the shielding are plastic scintillator panels, which serve as gross gamma ray detectors. The detector panels, with embedded photomultipliers, completely surround the internal measurement chamber on all 6 sides. Care has been taken to distribute the plastic scintillator detectors in order to optimise both the efficiency for gamma ray detection and at the same time achieve a volumetric sensitivity, which is as uniform as possible. A common high voltage power supply provides the bias voltage for each of the six photomultipliers. The voltage signals arising from the detectors and photomultipliers are amplified by six sensitive amplifiers. Each amplifier incorporates a single channel analyser with both upper and lower thresholds and the digitised counts from each detector are recorded on six scalars. Operation of the device is by means of a microprocessor from which the scalars are controlled. An internal load cell linked to the microprocessor determines the weight of the waste object, and this information is used to calculate the specific activity of the waste. The monitor makes background measurements when the shielded door is closed and a sample, usually a bag of low-density waste, is not present in the measurement chamber. Measurements of the minimum detectable activity (MDA) of an earlier large volume prototype instrument are reported as part of the development of the Waste Segregation and Clearance Monitor (WSCM) described in the paper. For the optimised WSCM a detection efficiency of greater than 32% was measured using a small Cs-137 source placed in the centre of the measurement chamber. Small sources have also been used to determine the spatial variation of the detection efficiency for various positions within the measurement chamber. The data have been used to establish sentencing limits and different 'fingerprints' for specific waste streams including waste streams containing fission products and others based on other radionuclides including Am-241. Some of the test data that are presented have been used to validate the instrument performance. The monitor is currently in routine use at a nuclear facility for the measurement and sentencing of low-density low activity radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗