Search NASA⌕ Search

SEARCH · Search NASA

Results for “probability and statistical methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Modelling the Fluctuations of Reactive Shock Waves in Heterogeneous Solid Explosives as Stochastic Processes

Although current phenomenological burn models are useful for describing the average or bulk reactive flow behaviour of heterogeneous explosives, one fundamental weakness inherent to these models is the loss of detailed microstructural information at the scale of the calculation. In order to include the effects of the microstructure, and in particular the underlying material heterogeneities that influence the build-up to detonation, a new paradigm is put forth for modelling sub-grid, reaction-induced fluctuations (i.e. “hot spots”) at the continuum level. This modelling approach assumes that the reaction rate is stochastic, rather than deterministic, and it uses Langevin-type equations with a mathematical framework built upon Itô calculus and Lambourn's CIM model for shocked heterogeneous explosives. This approach follows directly from our previous letter, Ref. [1], and is inspired by the probability density function (pdf) methods used in turbulent reactive flows. Here, the stochastic burn model is derived, implemented, and exercised far beyond what has been shown in previous work. New hydrocode simulation results demonstrate the role of stochastic fluctuations during shock initiation; these fluctuations are approximated by collections of discrete particles, that evolve with drift (i.e. deterministic) and diffusion (i.e. stochastic) coefficients. Furthermore, the particle values are propagated and averaged to calculate the heat release, yield strength, and material impedance in each computational cell. Hydrocode simulation results further show how the fluctuating hot spot energy may or may not be transmitted to the wave front, and result in a detonation wave-like structure. The fundamental stochastic nature of this model permits simulations to have varying outcomes with the same initial conditions; this allows for go/no-go estimation (e.g., marginal or failed detonations), which might possibly be calibrated using the statistical distributions from real materials. Mesoscale calculations of shocked heterogeneous explosives also show that these fluctuations are physically justified (i.e., Ref. [2]), and it is hypothesized that the pdf functions provide a link between the meso(grain) and continuum scales for practical engineering calculations. Hence, our approach is a paradigm shift for building efficient, reduced order continuum burn models, that represent the sub-grid stochastic behaviour of shocked heterogeneous solid explosives.

42 ENGINEERING↗

Description of induced nuclear fission with Skyrme energy functionals. II. Finite temperature effects

Understanding the mechanisms of induced nuclear fission for a broad range of neutron energies could help resolve fundamental science issues, such as the formation of elements in the universe, but could have also a large impact on societal applications in energy production or nuclear waste management. The goal of this paper is to set up the foundations of a microscopic theory to study the static aspects of induced fission as a function of the excitation energy of the incident neutron, from thermal to fast neutrons. To account for the high excitation energy of the compound nucleus, we employ a statistical approach based on finite temperature nuclear density functional theory with Skyrme energy densities, which we benchmark on the 239 Pu ($n ,f$) reaction. We compute the evolution of the least-energy fission pathway across multidimensional potential energy surfaces with up to five collective variables as a function of the nuclear temperature and predict the evolution of both the inner and the outer fission barriers as a function of the excitation energy of the compound nucleus. We show that the coupling to the continuum induced by the finite temperature is negligible in the range of neutron energies relevant for many applications of neutron-induced fission. We prove that the concept of quantum localization introduced recently can be extended to T > 0 , and we apply the method to study the interaction energy and total kinetic energy of fission fragments as a function of the temperature for the most probable fission. While large uncertainties in theoretical modeling remain, we conclude that a finite temperature nuclear density functional may provide a useful framework to obtain accurate predictions of fission fragment properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On/Off State Classification of a Reactor Facility Using Gas Effluence Measurements

Inferring on/off operational state of a reactor facility using measurements from an independent monitoring system is critical to the assessment of its compliance to agreements. In this paper, we consider the problem of inferring on/off state of a reactor facility using measurements of Ar-41, Cs-138, and Xe-138 gas effluence types collected at the facility’s off-gas stack. We present classifiers based on thresholding measurements of individual effluence types, and then present fusers that combine their outputs or measurements. We present five fusers based on simple majority rule, Chow’s pattern recognition function, Fisher’s combined p-value statistic, physics-based Poisson radiation counts model, and correlation coefficient method. In addition, we also test five machine learning methods based on non-linear classifiers, which are available as R packages. Finally, our results show that: (i) these gas effluence measurements are effective in inferring on/off state of a reactor facility; for example, best fusers achieve ~97% detection at ~1% false alarm rate, and (ii) fusers that combine all effluence types based on physics-based models, correlation coefficient and Fisher’s method outperform simple majority rule, Chow’s fusers and machine learning methods, as well as when they are applied to individual and pairs of effluence types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lessons Learned in Employing Data Analytics to Predict Oxidation Kinetics and Spallation Behavior of High-Temperature NiCr-Based Alloys

Machine learning (ML) can offer many advantages in predicting material properties over traditional materials development methods based solely on limited experimental investigations or physical-based simulations with the capability to reduce development cost, risk, and time. However, so far, limited efforts have been made to predict alloy oxidation kinetics and spallation behavior via ML due to the lack of consistently measured and sufficient experimental data and the inherent complexity in oxidation behavior of multicomponent high-temperature alloys. A previous study reported the ability of ML to predict oxidation kinetics of NiCr-based alloys as a function of alloy composition and operating conditions. Here, the performance of a ML model in predicting rate constants and spallation probability was evaluated in light of the roles of the data distribution of the experimental dataset (data analytics), the alloy composition, the exposure environment and the chosen oxidation approach to extracting kinetic values from the measured mass changes (but using either a simple parabolic law or a statistical cyclic oxidation model). Potential strategies to improve the predictions and enhance the extrapolative capability of the previously trained model will be discussed.

36 MATERIALS SCIENCE↗

Applying a Hypoxia-Incorporating TCP Model to Experimental Data on Rat Sarcoma

Purpose: To verify whether a tumor control probability (TCP) model which mechanistically incorporates acute and chronic hypoxia is able to describe animal in vivo dose-response data, exhibiting tumor reoxygenation. Methods and Materials: The investigated TCP model accounts for tumor repopulation, reoxygenation of chronic hypoxia, and fluctuating oxygenation of acute hypoxia. Using the maximum likelihood method, the model is fitted to Fischer-Moulder data on Wag/Rij rats, inoculated with rat rhabdomyosarcoma BA1112, and irradiated in vivo using different fractionation schemes. This data set is chosen because two of the experimental dose-response curves exhibit an inverse dose behavior, which is interpreted as due to reoxygenation. The tested TCP model is complex, and therefore, in vivo cell survival data on the same BA1112 cell line from Reinhold were added to Fischer-Moulder data and fitted simultaneously with a corresponding cell survival function. Results: The obtained fit to the combined Fischer-Moulder-Reinhold data was statistically acceptable. The best-fit values of the model parameters for which information exists were in the range of published values. The cell survival curves of well-oxygenated and hypoxic cells, computed using the best-fit values of the radiosensitivities and the initial number of clonogens, were in good agreement with the corresponding in vitro and in situ experiments of Reinhold. The best-fit values of most of the hypoxia-related parameters were used to recompute the TCP for non-small cell lung cancer patients as a function of the number of fractions, TCP(n). Conclusions: The investigated TCP model adequately describes animal in vivo data exhibiting tumor reoxygenation. The TCP(n) curve computed for non-small cell lung cancer patients with the best-fit values of most of the hypoxia-related parameters confirms previously obtained abrupt reduction in TCP for n < 10, thus warning against the adoption of severely hypofractionated schedules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced configurational sampling with hybrid non-equilibrium molecular dynamics–Monte Carlo propagator

Molecular dynamics (MD) trajectories based on classical equations of motion can be used to sample the configurational space of complex molecular systems. However, brute-force MD often converges slowly due to the ruggedness of the underlying potential energy surface. Several schemes have been proposed to address this problem by effectively smoothing the potential energy surface. However, in order to recover the proper Boltzmann equilibrium probability distribution, these approaches must then rely on statistical reweighting techniques or generate the simulations within a Hamiltonian tempering replica-exchange scheme. The present work puts forth a novel hybrid sampling propagator combining Metropolis-Hastings Monte Carlo (MC) with proposed moves generated by non-equilibrium MD (neMD). This hybrid neMD-MC propagator comprises three elementary elements: (i) an atomic system is dynamically propagated for some period of time using standard equilibrium MD on the correct potential energy surface; (ii) the system is then propagated for a brief period of time during what is referred to as a “boosting phase,” via a time-dependent Hamiltonian that is evolved toward the perturbed potential energy surface and then back to the correct potential energy surface; (iii) the resulting configuration at the end of the neMD trajectory is then accepted or rejected according to a Metropolis criterion before returning to step 1. A symmetric two-end momentum reversal prescription is used at the end of the neMD trajectories to guarantee that the hybrid neMD-MC sampling propagator obeys microscopic detailed balance and rigorously yields the equilibrium Boltzmann distribution. The hybrid neMD-MC sampling propagator is designed and implemented to enhance the sampling by relying on the accelerated MD and solute tempering schemes. It is also combined with the adaptive biased force sampling algorithm to examine. Illustrative tests with specific biomolecular systems indicate that the method can yield a significant speedup.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subgrid modelling for two-dimensional turbulence using neural networks

Here in this investigation, a data-driven turbulence closure framework is introduced and deployed for the subgrid modelling of Kraichnan turbulence. The novelty of the proposed method lies in the fact that snapshots from high-fidelity numerical data are used to inform artificial neural networks for predicting the turbulence source term through localized grid-resolved information. In particular, our proposed methodology successfully establishes a map between inputs given by stencils of the vorticity and the streamfunction along with information from two well-known eddy-viscosity kernels. Through this we predict the subgrid vorticity forcing in a temporally and spatially dynamic fashion. Our study is both a priori and a posteriori in nature. In the former, we present an extensive hyper-parameter optimization analysis in addition to learning quantification through probability-density-function-based validation of subgrid predictions. In the latter, we analyse the performance of our framework for flow evolution in a classical decaying two-dimensional turbulence test case in the presence of errors related to temporal and spatial discretization. Statistical assessments in the form of angle-averaged kinetic energy spectra demonstrate the promise of the proposed methodology for subgrid quantity inference. In addition, it is also observed that some measure of a posteriori error must be considered during optimal model selection for greater accuracy. The results in this article thus represent a promising development in the formalization of a framework for generation of heuristic-free turbulence closures from data.

42 ENGINEERING↗

Intelligent System Development Using a Rough Sets Methodology

The purpose of this research was to examine the potential of the rough sets technique for developing intelligent models of complex systems from limited information. Rough sets a simple but promising technology to extract easily understood rules from data. The rough set methodology has been shown to perform well when used with a large set of exemplars, but its performance with sparse data sets is less certain. The difficulty is that rules will be developed based on just a few examples, each of which might have a large amount of noise associated with them. The question then becomes, what is the probability of a useful rule being developed from such limited information? One nice feature of rough sets is that in unusual situations, the technique can give an answer of 'I don't know'. That is, if a case arises that is different from the cases the rough set rules were developed on, the methodology can recognize this and alert human operators of it. It can also be trained to do this when the desired action is unknown because conflicting examples apply to the same set of inputs. This summer's project was to look at combining rough set theory with statistical theory to develop confidence limits in rules developed by rough sets. Often it is important not to make a certain type of mistake (e.g., false positives or false negatives), so the rules must be biased toward preventing a catastrophic error, rather than giving the most likely course of action. A method to determine the best course of action in the light of such constraints was examined. The resulting technique was tested with files containing electrical power line 'signatures' from the space shuttle and with decompression sickness data.

Anderson, Gray T.↗

Incidence and Correlates of Radiation Pneumonitis in Pediatric Patients With Partial Lung Irradiation

Purpose: To provide a radiation pneumonitis risk estimate and investigate the correlation of clinical and dosimetric factors in pediatric patients receiving chest irradiation. Methods and Materials: A total of 122 patients diagnosed with sarcoma or Hodgkin lymphoma who received radiotherapy to the chest were evaluated for symptomatic radiation pneumonitis (Common Toxicity Criteria Grade 1 with respiratory symptom or higher grade). Pneumonitis data were collected from either prospective toxicity screenings as part of a clinical trial or through chart review. Dosimetric parameters including V{sub 10}-V{sub 25}, mean lung dose, binned lung dose, and tissue complication probability models were used, as well as clinical features to correlate with the development of pneumonitis. Results: The 1- and 2-year cumulative incidence of symptomatic radiation pneumonitis for all patients was 8.2% and 9.1%, respectively. Nine patients experienced symptomatic Grade 1 toxicity, and 2 experienced Grade 2. From univariate analysis, chemotherapy containing bleomycin ({chi}{sup 2} test, p = 0.027) and V{sub 24} (logistic regression, p = 0.019) were the clinical and dosimetric factors that resulted in statistically significant differences in the occurrence of pneumonitis. The probability of pneumonitis increased more dramatically with increasing V{sub 24} in patients receiving bleomycin than in those who did not. Adult tissue complication models did not differentiate pediatric patients with radiation pneumonitis from those without. Conclusions: The incidence of symptomatic radiation pneumonitis in pediatric patients is low and its severity mild. Parameters frequently used in adult radiation oncology provide some guidance as to risk, but pediatric patients warrant their own specific models for risk assessment, incorporating dosimetry and clinical factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Size and the Risk of Radiation Pneumonitis

Purpose: The purpose of this study was to identify patient populations treated for non-small cell lung cancer (NSCLC) who may be more at risk of radiation pneumonitis. Methods and Materials: A total of 579 patients receiving fractionated 3D conformal or intensity modulated radiation therapy (IMRT) for NSCLC were included in the study. Statistical analysis was performed to search for cohorts of patients with higher incidences of radiation pneumonitis. In addition to conventional risk factors, total and spared lung volumes were analyzed. The Lyman-Kutcher-Burman (LKB) and cure models were then used to fit the incidence of radiation pneumonitis as a function of lung dose and other factors. Results: Total lung volumes with a sparing of less than 1854 cc at 40 Gy were associated with a significantly higher incidence of radiation pneumonitis at 6 months (38% vs 12% for patients with larger volumes, P<.001). This patient cohort was overwhelmingly female and represented 22% of the total female population of patients and nearly 30% of the cases of radiation pneumonitis. An LKB fit to normal tissue complication probability (NTCP) including volume as a dose modifying factor resulted in a dose that results in a 50% probability of complication for the smaller spared volume cohort that was 9 Gy lower than the fit to all mean lung dose data and improved the ability to predict radiation pneumonitis (P<.001). Using an effective dose parameter of n=0.42 instead of mean lung dose further improved the LKB fit. Fits to the data using the cure model produced similar results. Conclusions: Spared lung volume should be considered when treating NSCLC patients. Separate dose constraints based on smaller spared lung volume should be considered. Smaller spared lung volume patients should be followed closely for signs of radiation pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r{sup 2} = 0.382, mean r{sup 2} = 0.236). Similar trends were found for organ midpoint versus height (max r{sup 2} = 0.439, mean r{sup 2} = 0.200) and for organ volume versus height (max r{sup 2} = 0.410, mean r{sup 2} = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r{sup 2}-values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r{sup 2} = 0.842, mean r{sup 2} = 0.790; max r{sup 2} = 0.949, mean r{sup 2} = 0.894; and max r{sup 2} = 0.870, mean r{sup 2} = 0.847, respectively). Moderate linear correlations were also observed for organ axial width versus height (max r{sup 2} = 0.772, mean r{sup 2} = 0.562) and for organ volume versus height (max r{sup 2} = 0.781, mean r{sup 2} = 0.601). Conclusions: Adult patients exhibited small variations in organ volume and location with respect to height and weight, but no meaningful correlation existed between these parameters and age or BMI. Once adulthood is reached, organ morphology and positioning seem to remain static. However, clear trends are evident between pediatric organ locations versus age, height, and weight. Such information can be incorporated into a matching methodology that may provide the highest probability of representing the anatomy of a patient undergoing a clinical exam to prospectively estimate the radiation dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-50: Evaluation of Monte Carlo Simulations Performance for Pediatric Brachytherapy Dosimetry

Purpose: Pediatric tumors are generally treated with multi-modal procedures. Brachytherapy can be used with pediatric tumors, especially given that in this patient population low toxicity on normal tissues is critical as is the suppression of the probability for late malignancies. Our goal is to validate the GATE toolkit on realistic brachytherapy applications, and evaluate brachytherapy plans on pediatrics for accurate dosimetry on sensitive and critical organs of interest. Methods: The GATE Monte Carlo (MC) toolkit was used. Two High Dose Rate (HDR) 192Ir brachytherapy sources were simulated (Nucletron mHDR-v1 and Varian VS2000), and fully validated using the AAPM and ESTRO protocols. A realistic brachytherapy plan was also simulated using the XCAT anthropomorphic computational model .The simulated data were compared to the clinical dose points. Finally, a 14 years old girl with vaginal rhabdomyosarcoma was modelled based on clinical procedures for the calculation of the absorbed dose per organ. Results: The MC simulations resulted in accurate dosimetry in terms of dose rate constant (Λ), radial dose gL(r) and anisotropy function F(r,θ) for both sources.The simulations were executed using ∼1010 number of primaries resulting in statistical uncertainties lower than 2%.The differences between the theoretical values and the simulated ones ranged from 0.01% up to 3.3%, with the largest discrepancy (6%) being observed in the dose rate constant calculation.The simulated DVH using an adult female XCAT model was also compared to a clinical one resulting in differences smaller than 5%. Finally, a realistic pediatric brachytherapy simulation was performed to evaluate the absorbed dose per organ and to calculate DVH with respect to heterogeneities of the human anatomy. Conclusion: GATE is a reliable tool for brachytherapy simulations both for source modeling and for dosimetry in anthropomorphic voxelized models. Our project aims to evaluate a variety of pediatric brachytherapy schemes using a population of pediatric phantoms for several pathological cases. This study is part of a project that has received funding from the European Union Horizon2020 research and innovation programme under the MarieSklodowska-Curiegrantagreement.No691203.The results published in this study reflect only the authors view and the Research Executive Agency (REA) and the European Commission is not responsible for any use that may be madeof the information it contains.

60 APPLIED LIFE SCIENCES↗

Comparison of Intensity-Modulated Radiotherapy Planning Based on Manual and Automatically Generated Contours Using Deformable Image Registration in Four-Dimensional Computed Tomography of Lung Cancer Patients

Purpose: To evaluate the implications of differences between contours drawn manually and contours generated automatically by deformable image registration for four-dimensional (4D) treatment planning. Methods and Materials: In 12 lung cancer patients intensity-modulated radiotherapy (IMRT) planning was performed for both manual contours and automatically generated ('auto') contours in mid and peak expiration of 4D computed tomography scans, with the manual contours in peak inspiration serving as the reference for the displacement vector fields. Manual and auto plans were analyzed with respect to their coverage of the manual contours, which were assumed to represent the anatomically correct volumes. Results: Auto contours were on average larger than manual contours by up to 9%. Objective scores, D{sub 2%} and D{sub 98%} of the planning target volume, homogeneity and conformity indices, and coverage of normal tissue structures (lungs, heart, esophagus, spinal cord) at defined dose levels were not significantly different between plans (p = 0.22-0.94). Differences were statistically insignificant for the generalized equivalent uniform dose of the planning target volume (p = 0.19-0.94) and normal tissue complication probabilities for lung and esophagus (p = 0.13-0.47). Dosimetric differences >2% or >1 Gy were more frequent in patients with auto/manual volume differences {>=}10% (p = 0.04). Conclusions: The applied deformable image registration algorithm produces clinically plausible auto contours in the majority of structures. At this stage clinical supervision of the auto contouring process is required, and manual interventions may become necessary. Before routine use, further investigations are required, particularly to reduce imaging artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing computation in an i-vector speaker recognition system using a tree-structured universal background model

The majority of state-of-the-art speaker recognition systems (SR) utilize speaker models that are derived from an adapted universal background model (UBM) in the form of a Gaussian mixture model (GMM). This is true for GMM supervector systems, joint factor analysis systems, and most recently i-vector systems. In all of the identified systems, the posterior probabilities and sufficient statistics calculations represent a computational bottleneck in both enrollment and testing. We propose a multi-layered hash system, employing a tree-structured GMM–UBM which uses Runnalls’ Gaussian mixture reduction technique, in order to reduce the number of these calculations. Moreover, with this tree-structured hash, we can trade-off reduction in computation with a corresponding degradation of equal error rate (EER). As an example, we also reduce this computation by a factor of 15× while incurring less than 10% relative degradation of EER (or 0.3% absolute EER) when evaluated with NIST 2010 speaker recognition evaluation (SRE) telephone data.

42 ENGINEERING↗

SU-D-16A-04: Accuracy of Treatment Plan TCP and NTCP Values as Determined Via Treatment Course Delivery Simulations

Purpose: To to determine if tumor control probability (TCP) and normal tissue control probability (NTCP) values computed on the treatment planning image are representative of TCP/NTCP distributions resulting from probable positioning variations encountered during external-beam radiotherapy. Methods: We compare TCP/NTCP as typically computed on the planning PTV/OARs with distributions of those parameters computed for CTV/OARs via treatment delivery simulations which include the effect of patient organ deformations for a group of 19 prostate IMRT pseudocases. Planning objectives specified 78 Gy to PTV1=prostate CTV+5 mm margin, 66 Gy to PTV2=seminal vesicles+8 mm margin, and multiple bladder/rectum OAR objectives to achieve typical clinical OAR sparing. TCP were computed using the Poisson Model while NTCPs used the Lyman-Kutcher-Bruman model. For each patient, 1000 30-fraction virtual treatment courses were simulated with each fractional pseudo- time-oftreatment anatomy sampled from a principle component analysis patient deformation model. Dose for each virtual treatment-course was determined via deformable summation of dose from the individual fractions. CTVTCP/ OAR-NTCP values were computed for each treatment course, statistically analyzed, and compared with the planning PTV-TCP/OARNTCP values. Results: Mean TCP from the simulations differed by <1% from planned TCP for 18/19 patients; 1/19 differed by 1.7%. Mean bladder NTCP differed from the planned NTCP by >5% for 12/19 patients and >10% for 4/19 patients. Similarly, mean rectum NTCP differed by >5% for 12/19 patients, >10% for 4/19 patients. Both mean bladder and mean rectum NTCP differed by >5% for 10/19 patients and by >10% for 2/19 patients. For several patients, planned NTCP was less than the minimum or more than the maximum from the treatment course simulations. Conclusion: Treatment course simulations yield TCP values that are similar to planned values, while OAR NTCPs differ significantly, indicating the need for probabilistic methods or PRVs for OAR risk assessment. Presenting author receives support from Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

Clinical evaluation of a medical high dynamic range display

Purpose: Recent new medical displays do have higher contrast and higher luminance but do not have a High Dynamic Range (HDR). HDR implies a minimum luminance value close to zero. A medical HDR display prototype based on two Liquid Crystal layers has been developed. The goal of this study is to evaluate the potential clinical benefit of such display in comparison with a low dynamic range (LDR) display. Methods: The study evaluated the clinical performance of the displays in a search and detection task. Eight radiologists read chest x-ray images some of which contained simulated lung nodules. The study used a JAFROC (Jacknife Free Receiver Operating Characteristic) approach for analyzing FROC data. The calculated figure of merit (FoM) is the probability that a lesion is rated higher than all rated nonlesions on all images. Time per case and accuracy for locating the center of the nodules were also compared. The nodules were simulated using Samei’s model. 214 CR and DR images [half were “healthy images” (chest nodule-free) and half “diseased images”] were used resulting in a total number of nodules equal to 199 with 25 images with 1 nodule, 51 images with 2 nodules, and 24 images with 3 nodules. A dedicated software interface was designed for visualizing the images for each session. For the JAFROC1 statistical analysis, the study is done per nodule category: all nodules, difficult nodules, and very difficult nodules. Results: For all nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.09% of difference. For the difficult nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 1.38% of difference. The averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.71% of difference. For the true positive fraction (TPF), both displays (the HDR and the LDR ones) have similar TPF for all nodules, but looking at difficult and very difficult nodules, there are more TP for the HDR display. The true positive fraction has been also computed in function of the local average luminance around the nodules. For the lowest luminance range, there is more than 30% in favor of the HDR display. For the highest luminance range, there is less than 6% in favor of the LDR display. Conclusions: This study shows the potential benefit of using a HDR display in radiology.

60 APPLIED LIFE SCIENCES↗

Bayes Error Rate Estimation Using Classifier Ensembles

The Bayes error rate gives a statistical lower bound on the error achievable for a given classification problem and the associated choice of features. By reliably estimating th is rate, one can assess the usefulness of the feature set that is being used for classification. Moreover, by comparing the accuracy achieved by a given classifier with the Bayes rate, one can quantify how effective that classifier is. Classical approaches for estimating or finding bounds for the Bayes error, in general, yield rather weak results for small sample sizes; unless the problem has some simple characteristics, such as Gaussian class-conditional likelihoods. This article shows how the outputs of a classifier ensemble can be used to provide reliable and easily obtainable estimates of the Bayes error with negligible extra computation. Three methods of varying sophistication are described. First, we present a framework that estimates the Bayes error when multiple classifiers, each providing an estimate of the a posteriori class probabilities, a recombined through averaging. Second, we bolster this approach by adding an information theoretic measure of output correlation to the estimate. Finally, we discuss a more general method that just looks at the class labels indicated by ensem ble members and provides error estimates based on the disagreements among classifiers. The methods are illustrated for artificial data, a difficult four-class problem involving underwater acoustic data, and two problems from the Problem benchmarks. For data sets with known Bayes error, the combiner-based methods introduced in this article outperform existing methods. The estimates obtained by the proposed methods also seem quite reliable for the real-life data sets for which the true Bayes rates are unknown.

Tumer, Kagan↗

A Nomogram to Predict Radiation Pneumonitis, Derived From a Combined Analysis of RTOG 9311 and Institutional Data

Purpose: To test the Washington University (WU) patient dataset, analysis of which suggested that superior-to-inferior tumor position, maximum dose, and D35 (minimum dose to the hottest 35% of the lung volume) were valuable to predict radiation pneumonitis (RP), against the patient database from Radiation Therapy Oncology Group (RTOG) trial 9311. Methods and Materials: The entire dataset consisted of 324 patients receiving definitive conformal radiotherapy for non-small-cell lung cancer (WU = 219, RTOG 9311 = 129). Clinical, dosimetric, and tumor location parameters were modeled to predict RP in the individual datasets and in a combined dataset. Association quality with RP was assessed using Spearman's rank correlation (r) for univariate analysis and multivariate analysis; comparison between subgroups was tested using the Wilcoxon rank sum test. Results: The WU model to predict RP performed poorly for the RTOG 9311 data. The most predictive model in the RTOG 9311 dataset was a single-parameter model, D15 (r = 0.28). Combining the datasets, the best derived model was a two-parameter model consisting of mean lung dose and superior-to-inferior gross tumor volume position (r = 0.303). An equation and nomogram to predict the probability of RP was derived using the combined patient population. Conclusions: Statistical models derived from a large pool of candidate models resulted in well-tuned models for each subset (WU or RTOG 9311), which did not perform well when applied to the other dataset. However, when the data were combined, a model was generated that performed well on each data subset. The final model incorporates two effects: greater risk due to inferior lung irradiation, and greater risk for increasing normal lung mean dose. This formula and nomogram may aid clinicians during radiation treatment planning for lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗