Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Solar Photovoltaic (PV) Damage Assessment After Typhoon Mawar: Findings and Recommendations for Resilient PV on Guam

A team from the National Renewable Energy Laboratory (NREL) visited Guam in August 2023 to assess failure modes of solar photovoltaic (PV) systems after Typhoon Mawar and to provide recommendations to increase the resilience of PV systems on Guam. The team visited 30 systems: commercial and utility scale, and rooftop and ground-mounted. The team observed systems with no apparent damage, as well as systems that were completely lost. Systems fared very well overall. The average failure rate of rooftop systems was 18%, with a median failure rate of 2%, meaning the few systems that suffered total loss pulled up the average. Only eight 8 of the 25 rooftop systems suffered more than 5% damage. All ground-mounted systems suffered less than 0.5% damage, aside from a carport that lost 16% of its modules. PV systems at Andersen Air Force Base suffered 5% damage on average, with a median system failure of 0.6%. In almost all cases, failures were the result of: (1) Inadequate clamping of the module frame to the mount, (2) Module mounting clamps rotating out of underlying support rail (i.e., T-bolt that rotates free at less than 60 degrees of rotation), (3) An object hitting the panel resulting in a fracture, and in some cases leading to a cascading failure of several more panels, and (4) Excessive tilt angle (in Guam, greater than 5 degrees can be a risk due to wind speed, and power production trade-offs are insignificant).

14 SOLAR ENERGY↗

Next-Generation NGV Driver Information System

Measuring the amount of fuel contained in the tank of a Natural Gas Vehicle (NGV) is not as straightforward as it is for a liquid-fueled vehicle. The fuel in an NGV is a compressed gas at pressures up to 4200psig, and its pressure changes with temperature. The current state-of-the-art, which is used on most NGVs, is a simple pressure gauge as a rough guide for remaining fuel. This presents a high degree of error because pressure varies widely depending on temperature. Immediately following refueling, the temperature in the vehicle’s cylinders is often greater than 150°F. As the driver pulls out of the fueling station and begins consuming gas, the pressure drops at a very fast rate due to expansion cooling of the gas. This pressure drop appears to the driver to be a very rapid decrease in fuel level, reducing trust in the fuel level indication and leading to concern about the distance the vehicle can travel before refueling again, which is known as “range anxiety.”

03 NATURAL GAS↗

Sierra/SD – Theory Manual – 5.22

Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD, we refer the reader to User’s Manual. Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer_notes manual, the user’s notes and of course the material in the open literature.

97 MATHEMATICS AND COMPUTING↗

Low-Cost, High-Performance Carbon Fiber for Compressed Natural Gas Storage Tanks (Final Technical Report – Down Select Report)

The aim of this project is to reduce the cost of Type IV, carbon fiber (CF) composite overwrap compressed gas storage tanks by reducing the cost of CF and CF composites. The project team worked to reduce the cost of CF by exploring and testing opportunities for a low-cost alternative precursor material for CF production to supplant market-dominant and costly polyacrylonitrile (PAN). Concurrently, the team aimed to reduce the cost of the tanks at the composite level by improving the interfacial adhesion between the fibers and the matrix resin through the incorporation of low-cost nanoparticles recycled from waste materials, which would reduce the volume of costly CF required to achieve the same tank performance. At the end of the first year, the project team selected mesophase pitch as the primary precursor candidate from a field of materials based on the superior mechanical performance and cost-saving potential. During the second year, the team produced CFs derived from mesophase pitch achieving an average tensile strength of 365.6 ksi and average tensile modulus of 40.74 Msi. Facility availability for spinning and converting these fibers at greater scale has hindered scale-up demonstration, but the team has identified opportunities to conduct this work in the near term. Cost modeling shows that these mesophase pitch-derived CFs can be up to 40% less expensive than PAN-derived CFs due to the lower cost of the feedstock material, higher throughput, greater conversion yield, and lower cost spinning method and compared to PAN. Additionally, the team has demonstrated at lab-scale that nanoparticle coating CFs can significantly increase the interfacial shear strength and load transfer efficiency of CFs in a matrix. Single filament pull-out testing showed a 27% average increase in max interfacial shear strength due to this coating. A continuous method of applying these coatings to a tow of CF has been developed for scale-up. 26 m tows of coated CFs were produced using this system and formed into composite ring samples for ASTM ring burst testing. Issues with the testing protocol have limited assessment of these results. A prototype Type IV tank was designed to meet ANSI HGV2 standards, and the design criteria set out by DOE, using the CF properties developed by the team paired with a proprietary resin matrix, a polyamide liner, and aluminum end bosses. The tank weighs 153.1 kg and with a total capacity of 5.8 kg H2 (5.6 kg usable), which yields a gravimetric capacity of 1.17 kWh/kg. Cost modeling predicts that the tank will have a projected cost of $15.73/kWh. Tank performance modeling does not include considerations for fiber-matrix load transfer efficiency improvements offered by nanoparticle coating method.

08 HYDROGEN↗

Sierra/SD – Theory Manual (V.5.24)

Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD, we refer the reader to User’s Manual. Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer_notes manual, the user’s notes and of course the material in the open literature.

42 ENGINEERING↗

Initial Testing of a Small Gamma Detector (GR1+) for Detection of Holdup in HEPA Filters

Measuring and assessing holdup is a key component of proper inventorying of a Material Balance Area (MBA). The Nuclear Material Control and Accountability (NMC&A) group at the Savannah River Site is responsible for ensuring that the methods used to determine holdup in the MBAs are valid for the conditions of that MBA. Holdup can be contained inside processing equipment or inside ventilation systems that that pulls air out of the glovebox through HEPA filters and stainless steel piping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Apptainer in a Pilot-based Distributed Workload

GlideinWMS is a pilot and pressure-based workload manager for distributed scientific computing. Many experiments like CMS and Fermilab’s Neutrino experiments use it to provision elastic clusters for their analysis and simulations, split into close to a million concurrent jobs. Most user jobs require containers, and the pilots use Apptainer to set up the desired platform. For the pilots that run as regular batch jobs, Apptainer is safer, lighter, and easier to use than other containerization solutions. Many images used by the pilots are expanded SIF images distributed via the CernVM-FS: this combination is very efficient. At Fermilab, for example, we store on GitHub Dockerfiles that mimic the platform in the worker nodes of local clusters. GitHub workflows build and push the images to Docker Hub, and a service periodically pulls and converts them to the expanded SIF images in the CernVM-FS, so the scientists can find a familiar environment everywhere. Apptainer has also been used to run services inside the pilot jobs, like benchmarks that characterize the worker node being used, or a Triton Inference Server that allows sharing a GPU with all the jobs that run in parallel on a node.

Mambelli, Marco [Fermilab] (ORCID:0000000294892681↗

Filtration of Hanford Tank 241-AW-105 Supernatant at 16 °C

Approximately 9 L of supernatant from Hanford waste tank 241-AW-105 was delivered by Hanford Tank Waste Operations and Closure (H2C) to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory (PNNL). The thirty-six 241-AW-105 sample bottles consisted of four sets of nine samples, with each set pulled from a unique tank sampling level. Prior to testing, samples from each level were composited and diluted to 5.5 M Na to provide nominally level-independent feed for dead-end filtration and ion exchange testing. The composited 241-AW-105 supernatant was chilled to 16 °C for 1 week prior to testing. Filtration testing was then conducted using a backpulse dead-end filter (BDEF) system equipped with a feed vessel and a Mott inline filter (Model 6610, Media Grade 5) in the hot cells of the RPL. The purpose of this testing was to (a) demonstrate dead-end filtration (DEF) of 241-AW-105 feed at reduced temperature to obtain prototypic Tank Side Cesium Removal (TSCR) flux rates and identify issues that may impact filtration after dilution to 5.5 M Na, and (b) provide feed for follow-on ion exchange unit operation. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft2. For most of the filtration campaign, the differential pressure required to effect filtration at 0.065 gpm/ft2 was slow to increase. After all the feed bottles had been pumped into the slurry reservoir, the bottoms of the bottles were added to the reservoir and transmembrane pressure (TMP) reached 2.0 psid (the TSCR action limit). A backpulse was performed after >50 hours of filtration to remove fouled solids and reduce the TMP. The filter was cleaned after completing filtration of the 241-AW-105 feed, and clean water flux tests showed filter performance was effectively restored. Solids concentrated from the backpulse solutions were composed of steel-like particles, uranium-bearing phases, Mn-Fe phases, a Ce-bearing phase, Zr phases, and some smaller Ca-bearing particles. The Ca-bearing and U bearing phases were identified as calcite and clarkeite, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Undissolved Solids from Salt Waste Processing Facility (SWPF) Salt Batches Collected via Filtration

SRNL researchers performed six experiments wherein 0.1 μm-grade stainless steel filters were used to filter samples pulled from salt batches 6, 9B, and 11B, without the addition of monosodium titanate. Three of these experiments were performed to collect filterable solids from each salt batch and characterize trapped solids via scanning electron microscopy. The remaining three experiments were performed to collect and then dissolve the same solids using 3.5 M nitric acid (similar to that employed in the Salt Waste Processing Facility) for characterization via Inductively-coupled plasma atomic emission spectroscopy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biofouling and Corrosion Study for a Novel Linear Guided Wave Energy Converter (Post Access Report)

The overall objective of this project was to examine the reliability and performance of antibiofouling coatings used for a wave energy converter (WEC) developed by E-Wave Technologies. The particular coatings were selected for their low toxicity and potential compatibility with aquaculture. The aim of this work was to 1) test coating solutions to prevent biofouling growth and saltwater corrosion on the static (paddle and attachment frame surface) components of the WEC that are submerged, 2) determine adhesion of the coatings to system components, and 3) assess the ease and effectiveness of biofouling cleaning to insure long term performance of the system. An analysis of commercial coatings was performed using methods to examine the prevention of biofouling and coating adhesion properties on two key materials of the WEC, which were 316L low carbon marine grade stainless steel (SS) and Ultra High Molecular Weight Polyethylene (PE). Three marine antifouling paints were selected based on their unique properties to test how different paint styles perform on different materials. The selected paints were ePaint Ecominder self-polishing paint with Zinc Omadine for slime control, Pettit ECO HRT Copper-Free ablative antifouling with Econea biocide, and Intersleek 1100SR foul release. Pacific Northwest National Laboratory (PNNL) prepared PE and SS substrates coated with the three paints and compared the performance against uncoated substrates when submerged in raw seawater for 3-, 6-, and 9-month (m) time periods. Results in adhesion testing indicated that Pettit and ePaint materials clearly bonded strongly to SS, but did not bond comparably well to PE. It was noted during adhesion testing that the Intersleek surfaces were especially difficult to test as the paint highly resists bonding to the epoxy adhesives used with the adherence testing platform. The wear rate of the coatings was not measured under this study; however, based on adhesion testing, coatings in the sliding regions of the Ewave device are expected to wear rapidly. Sandia National Laboratories (SNL) evaluated the adhesion of three different paints to PE and SS substrates which were exposed to a marine environment for time intervals of 0, 3, 6, and 9 months. From qualitative visual analysis of the 3 in2 coupons when pulled from the tank, the 3 in2 coupons generally only appeared to have biofouling consisting of filamentous algae or diatoms, which all have relatively low mass and can be easily wiped from the surface of coupons. Qualitative visual analysis indicated that ECO HRT and Unpainted were consistently worse than Intersleek and Ecominder at all time points. Results provide insight to aid with down-selection of commercial coatings under static conditions to support reliability of the WEC and potential maintenance schedules. This investigation was conducted using small coupon samples suspended in seawater and the development of testing rigs for dynamic component level testing is needed for future work. In addition, the potential toxicity of these commercial coatings on aquaculture has not been determined by this study. One recommendation is to conduct toxicity investigations at the Environmental Toxicity Laboratory at Oak Ridge National Laboratory.

16 TIDAL AND WAVE POWER↗

NETL LCA Update: Recent Highlights

The presentation was an update on impactful work completed by the NETL LCA Team during the past year. This presentation was part of a special session where DOE national laboratories are sharing updates on their LCA work. In addition to NETL, the session included presentations from Argonne National Laboratory, Lawrence Berkeley National Laboratory, the National Renewable Energy Laboratory, and the Pacific Northwest National Laboratory. This presentation from NETL includes updates on the Natural Gas Baseline, the Electricity Baseline, and Critical Mineral Collaborations/METALLIC. The figures are generally high level diagrams illustrating the scope and workflow for projects and are generally pulled from already public materials and published work.

critical minerals↗

pi-Extended Porphyrins: The Impact of Aromatic Heterocycles on the Properties of the Largely pi-Extended Structures (Final Report_UNT_SC0016766)

Largely π-extended carbon-rich materials represent fascinating yet challenging frontiers in chemistry and materials science as it offers numerous opportunities in molecular electronics. pi-Extended porphyrins possess unique set of electronic and photophysical properties and are very attractive for a wide range of applications. However, the synthesis and functionalization of pi-extended porphyrins had been very challenging. To explore and expand this intriguing research field, it is essential to develop synthetic tools to make them accessible. Funded by the Department of Energy Basic Energy Science, my laboratory addressed these synthetic challenges by developing concise and versatile methods for pi-extended porphyrins. Significant progress has been made in multiple directions, including fusing Polycyclic Aromatic Hydrocarbons (PAH), aromatic heterocycles, antiaromatic component, and cross-conjugated component to porphyrins as well as push-pull porphyrins. The availability of these methods has made it possible to rationally design and synthesize functionalized pi-extended porphyrins. Unprecedented electronic and photophysical properties have been discovered for these pi-extended porphyrins.

36 MATERIALS SCIENCE↗

Design of a remote-controlled mount for IOTA’s magnet undulator

The SLAC undulator is essential for studies of synchrotron radiation produced by a single electron in IOTA. Since IOTA is meant for different experiments, the undulator is not always needed, so it must be pushed and pulled back depending upon the nature of the experiment. Moving the undulator manually result in significant time loss about 30 minutes for the controlled access, and about 30 minutes to achieve beam injector in IOTA. Because the operation is done manually is not easy to ensure a good repeatability of the undulator position. That’s why IOTA’s team decided to set-up a completely remote-controlled mount.

42 ENGINEERING↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Legacy Devices and Interoperability: Developing a Scientific Strategy for Inclusion and Representation of Older Devices

Legacy devices across grid, transportation, and building systems present complex modernization challenges that extend far beyond simple equipment obsolescence. Pulling from presentations and break-out group discussions from this workshop on legacy devices across all three sectors, this report examines the interconnected factors driving replacement decisions, documents successful modernization initiatives from recent years, and provides strategic guidance for coordinating infrastructure transformation across these critical sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Literature Review of Selected Publications Relevant to Carbon Dioxide Pipeline and Storage Systems

The annotated bibliographies provided in this document focus on identifying and reviewing environmental impact statements (EIS), environmental assessments (EA), and scientific literature relevant to aspects of CO 2 pipeline and storage construction and operation. The purpose of these summaries is to aid stakeholders responsible for the preparation of documents compliant with the National Environmental Policy Act (NEPA) requirements to have access to a quick and comprehensive guide of the literature that can inform their activities. They aim to inform the development of EISs and EAs by identifying potential environmental concerns and mitigation strategies. The annotated bibliographies captured in this document cover the general environmental assessment and impact topics relevant to CO 2 pipeline and storage construction and operation activities, with the subject of waste creation and handling being specifically pulled out into its own section. The reasoning behind a dedicated section for waste is that many EAs and EISs focus on the description of waste and its impacts, be it caused in routine operation or as a result of an accident.

54 ENVIRONMENTAL SCIENCES↗

Iodine Speciation Effects in LAW Feeds

Tests were conducted on a DM10 vitrification system with prototypical off-gas treatment system, which includes an SBS, WESP, and evaporator based on the design of the evaporator to be installed at the WTP for concentration of the liquid effluents. This allowed determination of the partitioning and speciation of iodine between the melter and the off gas system components, including liquid effluents from the SBS and WESP as well as in the evaporator condensate and concentrate. Evaporator testing was decoupled from melter testing to permit filtration and pH adjustments of process solutions prior to evaporation. In addition, a slip stream was pulled from the exhaust downstream of the WESP and High-Efficiency Particulate Air (HEPA) filters and passed through a caustic scrubber simulating the WTP caustic scrubber to assess iodine partitioning to the caustic scrubber liquid effluent. The tests were conducted using simulated Hanford LAW from tank AP-107, which is the planned first feed for Direct Feed LAW (DFLAW) operations, at a nominal feed concentration of 5.6 molar Na over about 120 hours of testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Epitaxy of Beta-Ga2O3 on Highly-Offcut (Greater than 10 Degrees) Substrates

Beta-Ga2O3 has emerged as a leading candidate for next-generation power electronics, radio frequency (RF) switches, and extreme environment electronics due to a wide band gap (4.6 - 4.9 eV), high dopability (approximately 40 meV activation energy for an isolated silicon donor), and melt growth characteristics resulting in commercially available 4-inch substrates and commercial demonstrations of 6-inch substrates by multiple techniques. The (100) surface of Ga2O3 is highly desirable from a device and epitaxy standpoint - bulk growth of (100) material is more scalable than (010), the surface is nearly lattice-matched to p-type partner NiO, and Al2O3 incorporates at higher concentrations without phase separation. However, the epitaxial growth rate on (100) surfaces is less than 10% of other faces due to weak bonding and favorable desorption. Recent demonstrations have shown growth rate improvements from 0.4 nm/min to 1.5 nm/min by growing on (100) wafers that are offcut 6 degrees in the -c direction.1 These films show step-flow growth from (-201) step-edges and high electron mobility. Despite these exciting results, offcuts greater than 6 degrees have not been explored due to the waste associated with grinding and polishing large offcuts. In this talk we will discuss the molecular beam epitaxy (MBE) growth and properties of Beta-Ga2O3 grown on (100) substrates offcut in the -c direction up to 13.4 degrees. These large offcuts are enabled by edge-fed film-defined growth (EFG) where the offcut is grown into the surface by pulling the crystal through the EFG die with the seed crystal rotated by the desired offcut angle. We will demonstrate that 13.4 degrees offcut substrates still exhibit a terraced (100) surface, and that a >10x increase (4.8 nm/min) in growth rate is achieved. As previously reported on lower offcuts, we observe 100% reversal of substrate twin domains around the (001) direction at the substrate-epilayer interface. We will discuss electrical properties including record-low (by MBE) unintentional doping densities of < 5E15 cm-3.

36 MATERIALS SCIENCE↗