Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Auditory evoked field measurement using magneto-impedance sensors

The magnetic field of the human brain is extremely weak, and it is mostly measured and monitored in the magnetoencephalography method using superconducting quantum interference devices. In this study, in order to measure the weak magnetic field of the brain, we constructed a Magneto-Impedance sensor (MI sensor) system that can cancel out the background noise without any magnetic shield. Based on our previous studies of brain wave measurements, we used two MI sensors in this system for monitoring both cerebral hemispheres. In this study, we recorded and compared the auditory evoked field signals of the subject, including the N100 (or N1) and the P300 (or P3) brain waves. The results suggest that the MI sensor can be applied to brain activity measurement.

60 APPLIED LIFE SCIENCES↗

Room-temperature intrinsic ferromagnetism in epitaxial CrTe 2 ultrathin films

While the discovery of two-dimensional (2D) magnets opens the door for fundamental physics and next-generation spintronics, it is technically challenging to achieve the room-temperature ferromagnetic (FM) order in a way compatible with potential device applications. Here in this paper, we report the growth and properties of single- and few-layer CrTe 2 , a van der Waals (vdW) material, on bilayer graphene by molecular beam epitaxy (MBE). Intrinsic ferromagnetism with a Curie temperature (TC) up to 300 K, an atomic magnetic moment of ~0.21 μ B /Cr and perpendicular magnetic anisotropy (PMA) constant (K u ) of 4.89 × 10 5 erg/cm 3 at room temperature in these few-monolayer films have been unambiguously evidenced by superconducting quantum interference device and X-ray magnetic circular dichroism. This intrinsic ferromagnetism has also been identified by the splitting of majority and minority band dispersions with ~0.2 eV at Г point using angle-resolved photoemission spectroscopy. The FM order is preserved with the film thickness down to a monolayer (T C ~ 200 K), benefiting from the strong PMA and weak interlayer coupling. The successful MBE growth of 2D FM CrTe 2 films with room-temperature ferromagnetism opens a new avenue for developing large-scale 2D magnet-based spintronics devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Production yield of rare-earth ions implanted into an optical crystal

Rare-earth (RE) ions doped into desired locations of optical crystals might enable a range of novel integrated photonic devices for quantum applications. With this aim, we have investigated the production yield of cerium and praseodymium by means of ion implantation. As a measure, the collected fluorescence intensity from both implanted samples and single centers was used. With a tailored annealing procedure for cerium, a yield up to 53% was estimated. Praseodymium yield amounts up to 91%. Such high implantation yield indicates a feasibility of creation of nanopatterned rare-earth doping and suggests strong potential of RE species for on-chip photonic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mitigating photorefractive effect in thin-film lithium niobate microring resonators

Thin-film lithium niobate is an attractive integrated photonics platform due to its low optical loss and favorable optical nonlinear and electro-optic properties. However, in applications such as second harmonic generation, frequency comb generation, and microwave-to-optics conversion, the device performance is strongly impeded by the photorefractive effect inherent in thin-film lithium niobate. In this paper, we show that the dielectric cladding on a lithium niobate microring resonator has a significant influence on the photorefractive effect. By removing the dielectric cladding layer, the photorefractive effect in lithium niobate ring resonators can be effectively mitigated. Our work presents a reliable approach to control the photorefractive effect on thin-film lithium niobate and will further advance the performance of integrated classical and quantum photonic devices based on thin-film lithium niobate.

42 ENGINEERING↗

Anatomy of information scrambling and decoherence in the integrable Sachdev-Ye-Kitaev model

The growth of information scrambling, captured by out-of-time-order correlation functions (OTOCs), is a central indicator of the nature of many-body quantum dynamics. Here, we compute analytically the complete time dependence of the OTOC for an integrable Sachdev-Ye-Kitaev (SYK) model, 𝑁 Majoranas with random two-body interactions of infinite range, coupled to a Markovian bath at finite temperature. In the limit of no coupling to the bath, the time evolution of scrambling experiences different stages. For 𝑡≲√𝑁, after an initial polynomial growth, the OTOC approaches saturation in a power-law fashion with oscillations superimposed. At 𝑡∼√𝑁, the OTOC reverses trend and starts to decrease linearly in time. The reason for this linear decrease is that, despite being a subleading 1/𝑁 effect, the OTOC in this region is governed by the spectral form factor of the antisymmetric couplings of the SYK model. The linear decrease stops at 𝑡∼2⁢𝑁, the Heisenberg time, where saturation occurs. The effect of the environment is an overall exponential decay of the OTOC for times longer than the inverse of the coupling strength to the bath. Here, the oscillations at 𝑡≲√𝑁 indicate lack of thermalization—a desired feature for better performance of quantum information devices.

Open quantum systems & decoherence↗

Titanium nitride as a seed layer for Heusler compounds

Titanium nitride (TiN) shows low resistivity at room temperature (27 μΩ cm), high thermal stability and thus has the potential to serve as seed layer in magnetic tunnel junctions. High quality TiN thin films with regard to the crystallographic and electrical properties were grown and characterized by x-ray diffraction and 4-terminal transport measurements. Element specific x-ray absorption spectroscopy revealed pure TiN inside the thin films. To investigate the influence of a TiN seed layer on a ferro(i)magnetic bottom electrode in magnetic tunnel junctions, an out-of-plane magnetized Mn{sub 2.45}Ga as well as in- and out-of-plane magnetized Co{sub 2}FeAl thin films were deposited on a TiN buffer, respectively. The magnetic properties were investigated using a superconducting quantum interference device and anomalous Hall effect for Mn{sub 2.45}Ga. Magneto optical Kerr effect measurements were carried out to investigate the magnetic properties of Co{sub 2}FeAl. TiN buffered Mn{sub 2.45}Ga thin films showed higher coercivity and squareness ratio compared to unbuffered samples. The Heusler compound Co{sub 2}FeAl showed already good crystallinity when grown at room temperature on a TiN seed-layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrating magnetic Co-nanopillars in a NbN-based VAN thin film as a multifunctional hybrid metamaterial

NbN thin films are considered as a promising alternative candidate to conventional Al superconducting electrodes for Josephson junction devices, superconducting qubits and quantum logic circuits. Herein, by co-growing ferromagnetic Co with superconducting NbN, self-assembled NbN–Co vertically aligned nanocomposite (VAN) thin films have been successfully deposited on a MgO substrates, with NbN in its cubic superconducting phase. The obtained VAN metamaterials exhibit epitaxial growth of NbN with uniformly dispersed Co nanoplates. Further physical property characterization reveals that the NbN–Co VAN presents ferromagnet properties with strong out-of-plane magnetic anisotropy and optical anisotropy. This hybrid metamaterial system could find future applications in superconducting spintronic devices and quantum computing devices.

Zhang, Yizhi [Purdue Univ., West Lafayette, IN (Un↗

Mapping the intrinsic photocurrent streamlines through micromagnetic heterostructure devices

Photocurrent in quantum materials is often collected at global contacts far away from the initial photoexcitation. This collection process is highly nonlocal. It involves an intricate spatial pattern of photocurrent flow (streamlines) away from its primary photoexcitation that depends sensitively on the configuration of current collecting contacts as well as the spatial nonuniformity and tensor structure of conductivity. Direct imaging to track photocurrent streamlines is challenging. Here, we demonstrate a microscopy method to image photocurrent streamlines through ultrathin heterostructure devices comprising platinum on yttrium iron garnet (YIG). We accomplish this by combining scanning photovoltage microscopy with a uniform rotating magnetic field. Here, local photocurrent is generated through a photo-Nernst type effect with its direction controlled by the external magnetic field. This enables the mapping of photocurrent streamlines in a variety of geometries that include conventional Hall bar-type devices, but also unconventional wing-shaped devices called electrofoils. In these, we find that photocurrent streamlines display contortion, compression, and expansion behavior depending on the shape and angle of attack of the electrofoil devices, much in the same way as tracers in a wind tunnel map the flow of air around an aerodynamic airfoil. This affords a powerful tool to visualize and characterize charge flow in optoelectronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Source localization of brain activity using helium-free interferometer

To detect extremely small magnetic fields generated by the human brain, currently all commercial magnetoencephalography (MEG) systems are equipped with low-temperature (low-T{sub c}) superconducting quantum interference device (SQUID) sensors that use liquid helium for cooling. The limited and increasingly expensive supply of helium, which has seen dramatic price increases recently, has become a real problem for such systems and the situation shows no signs of abating. MEG research in the long run is now endangered. In this study, we report a MEG source localization utilizing a single, highly sensitive SQUID cooled with liquid nitrogen only. Our findings confirm that localization of neuromagnetic activity is indeed possible using high-T{sub c} SQUIDs. We believe that our findings secure the future of this exquisitely sensitive technique and have major implications for brain research and the developments of cost-effective multi-channel, high-T{sub c} SQUID-based MEG systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-chip, photon-number-resolving, telecommunication-band detectors for scalable photonic information processing

Integration is currently the only feasible route toward scalable photonic quantum processing devices that are sufficiently complex to be genuinely useful in computing, metrology, and simulation. Embedded on-chip detection will be critical to such devices. We demonstrate an integrated photon-number-resolving detector, operating in the telecom band at 1550 nm, employing an evanescently coupled design that allows it to be placed at arbitrary locations within a planar circuit. Up to five photons are resolved in the guided optical mode via absorption from the evanescent field into a tungsten transition-edge sensor. The detection efficiency is 7.2{+-}0.5 %. The polarization sensitivity of the detector is also demonstrated. Detailed modeling of device designs shows a clear and feasible route to reaching high detection efficiencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bright and durable scintillation from colloidal quantum shells

Abstract Efficient, fast, and robust scintillators for ionizing radiation detection are crucial in various fields, including medical diagnostics, defense, and particle physics. However, traditional scintillator technologies face challenges in simultaneously achieving optimal performance and high-speed operation. Herein we introduce colloidal quantum shell heterostructures as X-ray and electron scintillators, combining efficiency, speed, and durability. Quantum shells exhibit light yields up to 70,000 photons MeV −1 at room temperature, enabled by their high multiexciton radiative efficiency thanks to long Auger-Meitner lifetimes (>10 ns). Radioluminescence is fast, with lifetimes of 2.5 ns and sub-100 ps rise times. Additionally, quantum shells do not exhibit afterglow and maintain stable scintillation even under high X-ray doses (>10 9 Gy). Furthermore, we showcase quantum shells for X-ray imaging achieving a spatial resolution as high as 28 line pairs per millimeter. Overall, efficient, fast, and durable scintillation make quantum shells appealing in applications ranging from ultrafast radiation detection to high-resolution imaging.

47 OTHER INSTRUMENTATION↗

Negative capacitance switching via VO{sub 2} band gap engineering driven by electric field

We report the negative capacitance behavior of an energy band gap modulation quantum well with a sandwich VO{sub 2} layer structure. The phase transition is probed by measuring its capacitance. With the help of theoretical calculations, it shows that the negative capacitance changes of the quantum well device come from VO{sub 2} band gap by continuously tuning the temperature or voltage. Experiments reveal that as the current remains small enough, joule heating can be ignored, and the insulator-metal transition of VO{sub 2} can be induced by the electric field. Our results open up possibilities for functional devices with phase transitions induced by external electric fields other than the heating or electricity-heat transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flux-coherent series SQUID array magnetometers operating above 77 K with superior white flux noise than single-SQUIDs at 4.2 K

A very promising direction to improve the sensitivity of magnetometers based on superconducting quantum interference devices (SQUIDs) is to build a series-array of N non-interacting SQUIDs operating flux-coherently, because in this case their voltage modulation depth, ΔV, linearly scales with N whereas the white flux noise S{sub Φ}{sup 1/2} decreases as 1/N{sup 1/2}. Here, we report the realization of both these improvements in an advanced layout of very large SQUID arrays made of YBa{sub 2}Cu{sub 3}O{sub 7}. Specially designed with large area narrow flux focusers for increased field sensitivity and improved flux-coherency, our arrays have extremely low values for S{sub Φ}{sup 1/2} between (0.25 and 0.44) μΦ{sub 0}/Hz{sup 1/2} for temperatures in the range (77–83) K. In this respect, they outperform niobium/aluminium trilayer technology-based single-SQUIDs operating at 4.2 K. Moreover, with values for ΔV and transimpedance in the range of (10–17) mV and (0.3–2.5) kΩ, respectively, a direct connection to a low-noise room temperature amplifier is allowed, while matching for such readout is simplified and the available bandwidth is greatly increased. These landmark performances suggest such series SQUID arrays are ideal candidates to replace single-SQUIDs operating at 4.2 K in many applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental studies and micromagnetic simulations of electrodeposited Co nanotube arrays

Magnetic hollow nanotubes of cobalt forming close-packed arrays are synthesized by controlling the growth during electrodeposition in AAO template. Superconducting quantum interference device (SQUID) magnetometry is used to experimentally measure the static magnetization of the array of nanotubes. Excellent qualitative agreements of SQUID and micromagnetic simulations for static measurements are observed. This motivates us to evaluate dynamic response measurements via micromagnetic simulations. The coercivity simulated along the longitudinal axis of the nanotube is found increase with the length of isolated as well as for array of nanotubes. The effect of interactions is also clearly observed both in static as well as in dynamic evaluations. The interactions cause reduction in coercivity along with the switching which depends upon the length of the nanotubes. The calculation for FMR modes also indicates that propagation of the spin waves are greatly influenced by the hollow centre of nanotube as compare to nanowire and support to maintain the stable vortex configuration. For array of nanotubes, multiple peaks are found over larger number of frequencies which is anticipated due the interactions between nanotubes. Simulation for bias field and angular dependence of spin wave modes also yields a significant influenced by the presence of neighbouring nanotubes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of chiral currents at the magnetic domain boundary of a topological insulator

A magnetic domain boundary on the surface of a three-dimensional topological insulator is predicted to host a chiral edge state, but direct demonstration is challenging. Here, we used a scanning superconducting quantum interference device to show that current in a magnetized EuS/Bi 2 Se 3 heterostructure flows at the edge when the Fermi level is gate-tuned to the surface band gap. We further induced micron-scale magnetic structures on the heterostructure, and detected a chiral edge current at the magnetic domain boundary. The chirality of the current was determined by magnetization of the surrounding domain and its magnitude by the local chemical potential rather than the applied current. As a result, such magnetic structures, provide a platform for detecting topological magnetoelectric effects and may enable progress in quantum information processing and spintronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron-electron interactions in low-dimensional Si:P delta layers

Scientists have long studied the physics of highly disordered conducting systems, seeking to understand the multitude of quantum phenomena that govern how electrons move through material systems. Recently, research into silicon-based quantum computing has made disordered conducting systems, such as Si:P monolayers embedded in isotopically pure Si, technically relevant. Consequently, applying and advancing the theoretical frameworks developed to describe electron behavior in disordered systems is a necessary objective in this field of research. This study investigates key components of dopant-based Si quantum computing devices: embedded regions of highly doped delta layers (δ layers). We examine the transport behavior and the electron-electron interaction (EEI) physics in embedded Si:P δ layers by means of self-consistent magnetotransport measurements. Parameters associated with the electronic transport offer a meaningful quantitative characterization of δ-layer quality and dopant diffusion. In addition, by examining EEI behaviors in a set of samples with embedded Si:P δ layers produced with different PH3 exposure procedures prior to Si encapsulation, we show how details of material synthesis affect the dimensionality of charge carrier interactions in embedded Si:P δ layers. Furthermore, the relationship between δ-layer confinement and EEI screening lengths is established here. This understanding will help validate important models used for device simulation and design and lead to improvements in the control of electrostatic gating of and tunneling transport through Si:P single atom transistors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-Shot Readout Performance of Two Heterojunction-Bipolar-Transistor Amplification Circuits at Millikelvin Temperatures

High-fidelity single-shot readout of spin qubits requires distinguishing states much faster than the T 1 time of the spin state. One approach to improving readout fidelity and bandwidth (BW) is cryogenic amplification, where the signal from the qubit is amplified before noise sources are introduced and room-temperature amplifiers can operate at lower gain and higher BW. We compare the performance of two cryogenic amplification circuits: a current-biased heterojunction bipolar transistor circuit (CB-HBT), and an AC-coupled HBT circuit (AC-HBT). Both circuits are mounted on the mixing-chamber stage of a dilution refrigerator and are connected to silicon metal oxide semiconductor (Si-MOS) quantum dot devices on a printed circuit board (PCB). The power dissipated by the CB-HBT ranges from 0.1 to 1 μW whereas the power of the AC-HBT ranges from 1 to 20 μW. Referred to the input, the noise spectral density is low for both circuits, in the 15 to 30 fA/√Hz range. The charge sensitivity for the CB-HBT and AC-HBT is 330 μe/√Hz and 400 μe/√Hz, respectively. For the single-shot readout performed, less than 10 its is required for both circuits to achieve bit error rates below 10-3, which is a putative threshold for quantum error correction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Portable MRI developed at Los Alamos

Scientists at Los Alamos National Laboratory are developing an ultra-low-field Magnetic Resonance Imaging (MRI) system that could be low-power and lightweight enough for forward deployment on the battlefield and to field hospitals in the World's poorest regions. "MRI technology is a powerful medical diagnostic tool," said Michelle Espy, the Battlefield MRI (bMRI) project leader, "ideally suited for imaging soft-tissue injury, particularly to the brain." But hospital-based MRI devices are big and expensive, and require considerable infrastructure, such as large quantities of cryogens like liquid nitrogen and helium, and they typically use a large amount of energy. "Standard MRI machines just can't go everywhere," said Espy. "Soldiers wounded in battle usually have to be flown to a large hospital and people in emerging nations just don't have access to MRI at all. We've been in contact with doctors who routinely work in the Third World and report that MRI would be extremely valuable in treating pediatric encephalopathy, and other serious diseases in children." So the Los Alamos team started thinking about a way to make an MRI device that could be relatively easy to transport, set up, and use in an unconventional setting. Conventional MRI machines use very large magnetic fields that align the protons in water molecules to then create magnetic resonance signals, which are detected by the machine and turned into images. The large magnetic fields create exceptionally detailed images, but they are difficult and expensive to make. Espy and her team wanted to see if images of sufficient quality could be made with ultra-low-magnetic fields, similar in strength to the Earth's magnetic field. To achieve images at such low fields they use exquisitely sensitive detectors called Superconducting Quantum Interference Devices, or SQUIDs. SQUIDs are among the most sensitive magnetic field detectors available, so interference with the signal is the primary stumbling block. "SQUIDs are so sensitive they'll respond to a truck driving by outside or a radio signal 50 miles away," said Al Urbaitis, a bMRI engineer. The team's first generation bMRI had to be built in a large metal housing in order to shield it from interference. Now the Los Alamos team is working in the open environment without the large metal housing using a lightweight series of wire coils that surround the bMRI system to compensate the Earth’s magnetic field. In the future, the field compensation system will also function similar to noise-cancelling headphones to eradicate invading magnetic field signals on-the-fly.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗