Search NASA⌕ Search

SEARCH · Search NASA

Results for “random sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Detecting high-emitting methane sources in oil/gas fields using satellite observations

Methane emissions from oil/gas fields originate from a large number of relatively small and densely clustered point sources. A small fraction of high-mode emitters can make a large contribution to the total methane emission. Here we conduct observation system simulation experiments (OSSEs) to examine the potential of recently launched or planned satellites to detect and locate these high-mode emitters through measurements of atmospheric methane columns. We simulate atmospheric methane over a generic oil/gas field (20–500 production sites of different size categories in a 50 × 50 km 2 domain) for a 1-week period using the WRF-STILT meteorological model with 1.3 × 1.3 km 2 horizontal resolution. The simulations consider many random realizations for the occurrence and distribution of high-mode emitters in the field by sampling bimodal probability density functions (PDFs) of emissions from individual sites.

54 ENVIRONMENTAL SCIENCES↗

Long history of Cl-36 Assessment of Graphite Waste by EDF Engineering and the Latest Suggested Developments - 17043

Prior to 2005, the EDF initial version for the radiological inventory of graphite was based on the maximum values of the measures, namely a very pessimistic way. In 2008, a scientific method was developed by EDF to evaluate the inventory by reverse activation calculation, in order to limit the overestimation. The radiological inventory computation principles can be compared to those of all engineering studies. First, the calculation is simplified by taking margins, and if the results are not satisfactory enough, some simplifications are suppressed to reduce these margins even if computation becomes more complicated. On EDF piles, the gain obtained in 2008 represented a factor 50 relative to the initial version of Cl-36, even with a very penalizing multiplicative factor for uncertainty. Today, the accurate calculation of the uncertainty no longer justifies such a factor. A gain of about 150 now occurs compared to the initial version of Cl-36. It is more than 2 orders of magnitude, which is already enough to assess again the necessary type of disposal because Cl-36 is one of the key radionuclides. After global presentation of graphite waste management in France, the paper focuses on the inventory scientific process of EDF nuclear graphite, the purity of graphite and its consequences, its particular sampling, the lessons learned, the initial method description, the link with the demonstration of the completely random point process of chlorine in nuclear graphite and the last suggested precise uncertainty computation of inventory of Cl-36. The method confirmation for concentration assessment, the history of the EDF method development and its benefits are also emphasized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulated Contrast of Two Dislocations

A three-dimensional Monte Carlo simulation algorithm is used to study the contrast of two dislocations perpendicular to the irradiated surface of an n-doped silicon sample in the electron beam induced current mode. The dislocations are positioned in the irradiation trajectory, and each of both is considered as a cylinder where the minority carrier diffusion length varies abruptly from a low inside dislocations up to a high value outside dislocations. The EBIC contrast was obtained by simulating the random diffusion of carriers generated at point-like sources randomly distributed within the generation volume. Results are analyzed on the basis of change in the generation volume in the bulk of the sample and of carrier trapping process inside dislocations. The EBIC contrast increases with the increase of the electron beam energy. It also increases when the minority diffusion length inside dislocations, or their separating distance decreases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

Chromosome Damage and Cell Proliferation Rates in In Vitro Irradiated Whole Blood as Markers of Late Radiation Toxicity After Radiation Therapy to the Prostate

Purpose: In vitro irradiated blood samples from prostate cancer patients showing late normal tissue damage were examined for lymphocyte response by measuring chromosomal aberrations and proliferation rate. Methods and Materials: Patients were selected from a randomized trial evaluating the optimal timing of dose-escalated radiation and short-course androgen deprivation therapy. Of 438 patients, 3% experienced grade 3 late radiation proctitis and were considered to be radiosensitive. Blood samples were taken from 10 of these patients along with 20 matched samples from patients with grade 0 proctitis. The samples were irradiated at 6 Gy and, along with control samples, were analyzed for dicentric chromosomes and excess fragments per cell. Cells in first and second metaphase were also enumerated to determine the lymphocyte proliferation rate. Results: At 6 Gy, there were statistically significant differences between the radiosensitive and control cohorts for 3 endpoints: the mean number of dicentric chromosomes per cell (3.26 ± 0.31, 2.91 ± 0.32; P=.0258), the mean number of excess fragments per cell (2.27 ± 0.23, 1.43 ± 0.37; P<.0001), and the proportion of cells in second metaphase (0.27 ± 0.10, 0.46 ± 0.09; P=.0007). Conclusions: These results may be a valuable indicator for identifying radiosensitive patients and for tailoring radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hormonal contraception alters vaginal microbiota and cytokines in South African adolescents in a randomized trial

Young women in sub-Saharan Africa are disproportionally affected by HIV infection and unintended pregnancies. However, hormonal contraceptive (HC) use may influence HIV risk through changes in genital tract microbiota and inflammatory cytokines. To investigate this, 130 HIV negative adolescent females aged 15–19 years were enrolled into a substudy of UChoose, an open-label randomized crossover study (NCT02404038), comparing acceptability and contraceptive product preference as a proxy for HIV prevention delivery methods. Participants were randomized to injectable norethisterone enanthate (Net-En), combined oral contraceptives (COC) or etonorgesterol/ethinyl estradiol combined contraceptive vaginal ring (CCVR) for 16 weeks, then crossed over to another HC for 16 weeks. Cervicovaginal samples were collected at baseline, crossover and exit for characterization of the microbiota and measurement of cytokine levels; primary endpoints were cervical T cell activation, vaginal microbial diversity and cytokine concentrations. Adolescents randomized to COCs had lower vaginal microbial diversity and relative abundance of HIV risk-associated taxa compared to Net-En or CCVR. Cervicovaginal inflammatory cytokine concentrations were significantly higher in adolescents randomized to CCVR compared to COC and Net-En. This suggests that COC use may induce an optimal vaginal ecosystem by decreasing bacterial diversity and inflammatory taxa, while CCVR use is associated with genital inflammation.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental Design for a Sponge-Wipe Study to Relate the Recovery Efficiency and False Negative Rate to the Concentration of a Bacillus anthracis Surrogate for Six Surface Materials

Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the probability of correct detection (PCD) (or equivalently the false negative rate FNR = 1 - PCD). The PCD/FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5) sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method. A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not PCD/FNR (which left a major gap in available information). Quantifying the PCD/FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in PCD/FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The study will investigate the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and PCD/FNR. The experimental design involves 16 test runs, to be performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) will be tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations will be very low and may present challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and PCD/FNR over the full range of concentrations of interest. In each run, there will be 10 test coupons of each of the three surface materials. A positive control sample will be generated prior to each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and PCD-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the PCD for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting PCD-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in PCD and RE predictions made with the fitted equations.

59 BASIC BIOLOGICAL SCIENCES↗

High Entropy Protected Sharp Magnetic Transitions in Highly Disordered Spinel Ferrites

How disorder affects magnetic ordering is always an intriguing question, and it becomes even more interesting in the recently rising high entropy oxides due to the extremely high disorder density. However, due to the lack of high-quality single crystal samples, the strong compositional disorder effect on magnetic transition has not been deeply investigated. In this work, we have successfully synthesized high-quality single crystalline high entropy spinel ferrites (Mg 0.2 Mn 0.2 Fe 0.2 Co 0.2 Ni 0.2 ) x Fe 3-x O 4 . Our findings from high-temperature magnetization and neutron diffraction experiments showed ferrimagnetic transitions at 748, 694, and 674 K for x values of 1, 1.5, and 1.8, respectively. Notably, the magnetic transition almost showed no broadening for x values of 1 and 1.5, compared to Fe 3 O 4 . Extended X-ray absorption fine structure measurements provided insights into the elemental distribution among the octahedral and tetrahedral sites. The random distribution of elements across these sites reduced the formation of local clusters and short-range orders, enhancing sample homogeneity and preserving the sharpness of the magnetic transition, despite bond length variation. Here, our study not only marks the first successful synthesis of an HEO bulk single crystal exhibiting long-range magnetic order but also sheds light on the interaction between high configurational entropy and magnetic orderings. This opens new avenues for future research and applications of magnetic high entropy oxides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ca II TRIPLET SPECTROSCOPY OF SMALL MAGELLANIC CLOUD RED GIANTS. I. ABUNDANCES AND VELOCITIES FOR A SAMPLE OF CLUSTERS

We have obtained near-infrared spectra covering the Ca II triplet lines for a large number of stars associated with 16 Small Magellanic Cloud (SMC) clusters using the VLT + FORS2. These data compose the largest available sample of SMC clusters with spectroscopically derived abundances and velocities. Our clusters span a wide range of ages and provide good areal coverage of the galaxy. Cluster members are selected using a combination of their positions relative to the cluster center as well as their location in the color-magnitude diagram, abundances, and radial velocities (RVs). We determine mean cluster velocities to typically 2.7 km s{sup -1} and metallicities to 0.05 dex (random errors), from an average of 6.4 members per cluster. By combining our clusters with previously published results, we compile a sample of 25 clusters on a homogeneous metallicity scale and with relatively small metallicity errors, and thereby investigate the metallicity distribution, metallicity gradient, and age-metallicity relation (AMR) of the SMC cluster system. For all 25 clusters in our expanded sample, the mean metallicity [Fe/H] = -0.96 with {sigma} = 0.19. The metallicity distribution may possibly be bimodal, with peaks at {approx}-0.9 dex and -1.15 dex. Similar to the Large Magellanic Cloud (LMC), the SMC cluster system gives no indication of a radial metallicity gradient. However, intermediate age SMC clusters are both significantly more metal-poor and have a larger metallicity spread than their LMC counterparts. Our AMR shows evidence for three phases: a very early (>11 Gyr) phase in which the metallicity reached {approx}-1.2 dex, a long intermediate phase from {approx}10 to 3 Gyr in which the metallicity only slightly increased, and a final phase from 3 to 1 Gyr ago in which the rate of enrichment was substantially faster. We find good overall agreement with the model of Pagel and Tautvaisiene, which assumes a burst of star formation at 4 Gyr. Finally, we find that the mean RV of the cluster system is 148 km s{sup -1}, with a velocity dispersion of 23.6 km s{sup -1} and no obvious signs of rotation amongst the clusters. Our result is similar to what has been found from a wide variety of kinematic tracers in the SMC, and shows that the SMC is best represented as a pressure supported system.

79 ASTRONOMY AND ASTROPHYSICS↗

Structural Studies of Amorphous Materials by Fluctuation Electron Microscopy

Fluctuation Electron Microscopy (FEM) is a technique that examines the fluctuations in electron scattering across a uniformly thin amorphous sample. The statistics of the intensity fluctuations, mean and variance, reveal any underlying medium-range order present in the structure. The goals of this project were: (1) To determine the fundamentals of the scattering physics that gives rise to the variance signal in fluctuation electron microscopy (FEM); (2) To use these discoveries to find ways to quantify FEM; (3) To apply the FEM method to interesting and technologically important families of amorphous materials, particularly those with important applications in energy-related processes. Excellent progress was made in items (1) and (2). In stage (3) we did not examine the metamict zircons, as proposed. Instead, we examined films of polycrystalline and amorphous semi-conducting diamond. Significant accomplishments are: (1) A Reverse Monte Carlo procedure was successfully implemented to invert FEM data into a structural model. This is computer-intensive, but it demonstrated that diffraction and FEM data from amorphous silicon are most consistent with a paracrystallite model. This means that there is more diamond-like topology present in amorphous silicon than is predicted by the continuous random network model. (2) There is significant displacement decoherence arising in diffraction from amorphous silicon and carbon. The samples are being bombarded by the electron beam and atoms do not stay still while being irradiated – much more than was formerly understood. The atom motions cause the destructive and constructive interferences in the diffraction pattern to fluctuate with time, and it is the time-averaged speckle that is being measured. The variance is reduced by a factor m, 4 ≤ m ≤ 1000, relative to that predicted by kinematical scattering theory. (3) Speckle intensity obeys a gamma distribution, where the mean intensity $ \overline{I}\ $ and m are the two parameters governing the shape of the gamma distribution profile. m is determined by the illumination spatial coherence, which is normally very high, and mostly by the displacement decoherence within the sample. (4) Amorphous materials are more affected by the electron beam than are crystalline materials. Different samples exhibit different disruptibility, as measured by the effective values of m that fit the data. (5) Understanding the origin of the displacement decoherence better should lead to efficient methods for computing the observed variance from amorphous materials.

36 MATERIALS SCIENCE↗

Tools for Water Ingress Testing

The Safety Storage and Engineering Team, as part of the Production Support Services division (PSS-2), is tasked with ensuring the safety of containers used for handling and storage of nuclear materials. As part of this work, water ingress tests are conducted to evaluate the water-tightness of containers intended for in-glovebox use. In collaboration, the statistics group of the Computer and Computational Sciences Division (CCS-6) provided support in developing a statistically defensible approach for determining appropriate sample sizes for water ingress testing. Water ingress testing involves multiple measurements on multiple containers. Our approach uses a simple random effects model to analyze a pilot data set, implementing prediction limits to evaluate the efficacy of collecting additional data. Although this study capitalizes on available data, our approach can be used with estimates of the ratio of between and within variability and average values, often available from past testing or expert knowledge. An interactive Shiny tool was developed as a final user-friendly product for future testing. The Shiny interface is an open-source package providing a framework for building web applications. Raw data exploration and prediction interval-based sample size assessments can quickly be conducted by the engineering team without needing to interact with the underlying code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimal sampling efficiency in Monte Carlo sampling with an approximate potential

Building on the work of Iftimie et al., Boltzmann sampling of an approximate potential (the 'reference' system) is used to build a Markov chain in the isothermal-isobaric ensemble. At the endpoints of the chain, the energy is evaluated at a higher level of approximation (the 'full' system) and a composite move encompassing all of the intervening steps is accepted on the basis of a modified Metropolis criterion. For reference system chains of sufficient length, consecutive full energies are statistically decorrelated and thus far fewer are required to build ensemble averages with a given variance. Without modifying the original algorithm, however, the maximum reference chain length is too short to decorrelate full configurations without dramatically lowering the acceptance probability of the composite move. This difficulty stems from the fact that the reference and full potentials sample different statistical distributions. By manipulating the thermodynamic variables characterizing the reference system (pressure and temperature, in this case), we maximize the average acceptance probability of composite moves, lengthening significantly the random walk between consecutive full energy evaluations. In this manner, the number of full energy evaluations needed to precisely characterize equilibrium properties is dramatically reduced. The method is applied to a model fluid, but implications for sampling high-dimensional systems with ab initio or density functional theory (DFT) potentials are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Bi-functional nonlinearities in monodisperse ZnO nano-grains – Self-consistent transport and random lasing

We report a quantum field theoretical description of light transport and random lasing. The Bethe-Salpeter equation is solved including maximally crossed diagrams and non-elastic scattering. This is the first theoretical framework that combines so called off-shell scattering and lasing in random media. We present results for the self-consistent scattering mean free path that varies over the width of the sample. Further we discuss the density dependent correlation length of self-consistent transport in disordered media composed of semi-conductor Mie scatterers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absence of long-range chemical ordering in equimolar FeCoCrNi

Equimolar FeCoCrNi alloys have been the topic of recent research as 'high-entropy alloys,' where the name is derived from the high configurational entropy of mixing for a random solid solution. Despite their name, no systematic study of ordering in this alloy system has been performed to date. Here, we present results from anomalous x-ray scattering and neutron scattering on quenched and annealed samples. An alloy of FeNi{sub 3} was prepared in the same manner to act as a control. Evidence of long-range chemical ordering is clearly observed in the annealed FeNi{sub 3} sample from both experimental techniques. The FeCoCrNi sample given the same heat treatment lacks long-range chemical order.

36 MATERIALS SCIENCE↗

BINARY FORMATION MECHANISMS: CONSTRAINTS FROM THE COMPANION MASS RATIO DISTRIBUTION

We present a statistical comparison of the mass ratio distribution of companions, as observed in different multiplicity surveys, to the most recent estimate of the single-object mass function. The main goal of our analysis is to test whether or not the observed companion mass ratio distribution (CMRD) as a function of primary star mass and star formation environment is consistent with having been drawn from the field star initial mass function (IMF). We consider samples of companions for M dwarfs, solar-type stars, and intermediate-mass stars, both in the field as well as clusters or associations, and compare them with populations of binaries generated by random pairing from the assumed IMF for a fixed primary mass. With regard to the field we can reject the hypothesis that the CMRD was drawn from the IMF for different primary mass ranges: the observed CMRDs show a larger number of equal-mass systems than predicted by the IMF. This is in agreement with fragmentation theories of binary formation. For the open clusters {alpha} Persei and the Pleiades we also reject the IMF random-pairing hypothesis. Concerning young star-forming regions, currently we can rule out a connection between the CMRD and the field IMF in Taurus but not in Chamaeleon I. Larger and different samples are needed to better constrain the result as a function of the environment. We also consider other companion mass functions and we compare them with observations. Moreover the CMRD both in the field and clusters or associations appears to be independent of separation in the range covered by the observations. Combining therefore the CMRDs of M (1-2400 AU) and G (28-1590 AU) primaries in the field and intermediate-mass primary binaries in Sco OB2 (29-1612 AU) for mass ratios, q = M{sub 2}/M{sub 1}, from 0.2 to 1, we find that the best chi-square fit follows a power law dN/dq{proportional_to}q {sup {beta}}, with {beta} = -0.50 {+-} 0.29, consistent with previous results. Finally, we note that the Kolmogorov-Smirnov test gives a {approx}1% probability of the observed CMRD in the Pleiades and Taurus being consistent with that observed for solar-type primaries in the field over comparable primary mass range. This highlights the value of using CMRDs to understand which star formation events contribute most to the field.

79 ASTRONOMY AND ASTROPHYSICS↗

Organic doping of rotated double layer graphene

Charge transfer techniques have been extensively used as knobs to tune electronic properties of two- dimensional systems, such as, for the modulation of conductivity \ mobility of single layer graphene and for opening the bandgap in bilayer graphene. The charge injected into the graphene layer shifts the Fermi level away from the minimum density of states point (Dirac point). In this work, we study charge transfer in rotated double-layer graphene achieved by the use of organic dopant, Tetracyanoquinodimethane. Naturally occurring bilayer graphene has a well-defined A-B stacking whereas in rotated double-layer the two graphene layers are randomly stacked with different rotational angles. This rotation is expected to significantly alter the interlayer interaction. Double-layer samples are prepared using layer-by-layer assembly of chemical vapor deposited single-layer graphene and they are identified by characteristic resonance in the Raman spectrum. The charge transfer and distribution of charges between the two graphene layers is studied using Raman spectroscopy and the results are compared with that for single-layer and A-B stacked bilayer graphene doped under identical conditions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Critical behavior and non-universal low-field magnetic scaling in La{sub 1-x}Bi{sub x}MnO{sub 3} (x=0.4 & 0.6) perovskite manganite oxide

We report on critical behavior in La{sub 1-x}Bi{sub x}MnO{sub 3} (x=0.4 & 0.6) perovskite manganite oxide by studying AC susceptibility, χ, measured at randomly chosen low magnetic fields (H=9.45 Oe to 0.95 Oe) at fixed frequency of f=131 Hz. The samples exhibit non-uniformity in their magnetic spin interactions around paramagnetic-to-ferromagnetic transition temperature (T{sub C}). By non-universal low-field magnetic scaling of AC χ given as, χ{sup −1}-χ{sup −1}(T{sub C}) ∼ (T/T{sub C}−1){sup γ} ≡ τ{sup γ} the magnetic interactions in the samples around T{sub C} has been studied. The linear fit to ln (χ{sup −1} - χ{sub C}{sup −1}) vs. ln (T/T{sub C}-1) gives the values of critical exponent ‘γ’ under applied magnetic fields. The values of γ is found to be ∼1.48±0.007 for the sample with x=0.4 and ∼1.36±0.004 for x=0.6 at 0.95 Oe lie in the context of 3D Heisenberg type spin interactions. The profound 3D Heisenberg type spin interactions arises due to the phase separation effect for x=0.4 and breaking of ferromagnetic order and induced Bi{sup 3+} (6S{sup 2}) − O{sup 2−} (2P{sup 6}) lattice distortions for x=0.6 as discussed in manuscript.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗