Search NASA⌕ Search

SEARCH · Search NASA

Results for “range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Increasing the energy dynamic range of solid-state nuclear track detectors using multiple surfaces

Solid-state nuclear track detectors, such as CR-39, are widely used in physics and in many inertial confinement fusion (ICF) experiments. In the ICF experiments, the particles of interest, such as D{sup 3}He-protons, have ranges of order of the detector thickness. In this case, the dynamic range of the detector can be extended by recording data on both the front and back sides of the detector. Higher energy particles which are undetectable on the front surface can then be measured on the back of the detector. Studies of track formation under the conditions on the front and back of the detector reveal significant differences. Distinct front and back energy calibrations of CR-39 are therefore necessary and are presented for protons. Utilizing multiple surfaces with additional calibrations can extend the range of detectable energies on a single piece of CR-39 by up to 7-8 MeV. The track formation process is explored with a Monte Carlo code, which shows that the track formation difference between front and back is due to the non-uniform ion energy deposition in matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Seesaw actuation of atomic force microscope probes for improved imaging bandwidth and displacement range

The authors describe a method of actuation for atomic force microscope (AFM) probes to improve imaging speed and displacement range simultaneously. Unlike conventional piezoelectric tube actuation, the proposed method involves a lever and fulcrum ''seesaw'' like actuation mechanism that uses a small, fast piezoelectric transducer. The lever arm of the seesaw mechanism increases the apparent displacement range by an adjustable gain factor, overcoming the standard tradeoff between imaging speed and displacement range. Experimental characterization of a cantilever holder implementing the method is provided together with comparative line scans obtained with contact mode imaging. An imaging bandwidth of 30 kHz in air with the current setup was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-energy inverse photoemission spectroscopy using a high-resolution grating spectrometer in the near ultraviolet range

An inverse photoemission spectroscopy (IPES) apparatus using a Czerny-Turner grating spectrometer is demonstrated. Previous IPES instruments based on grating spectrometers used a concave grating and operated in the vacuum ultraviolet range. The reflectance of such gratings is lower than 20% and the aberration cannot be finely corrected leading to an energy resolution of up to 0.1 eV. In the present study, employing the low energy IPES regime [H. Yoshida, Chem. Phys. Lett. 539–540, 180 (2012)], incident electrons with a kinetic energy below 5 eV are used, while photon emission in the range of between 250 and 370 nm is analyzed with a 10-cm Czerny-Turner grating spectrometer. The signal intensity is at least 30 times higher than the previous apparatus. The resolution of photon detection is set at 0.07 eV though the ultimate resolution is one order of magnitude higher. The experiment is performed both by sweeping the electron energy (isochromat mode) and by simultaneously analyzing the photon of whole wavelength range (tunable photon energy mode)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A synchrotron-radiation-based variable angle ellipsometer for the visible to vacuum ultraviolet spectral range

A rotating analyzer spectroscopic polarimeter and ellipsometer with a wide-range θ-2θ goniometer installed at the Insertion Device Beamline of the Metrology Light Source in Berlin is presented. With a combination of transmission- and reflection-based polarizing elements and the inherent degree of polarization of the undulator radiation, this ellipsometer is able to cover photon energies from about 2 eV up to 40 eV. Additionally, a new compensator design based on a CaF{sub 2} Fresnel rhomb is presented. This compensator allows ellipsometric measurements with circular polarization in the vacuum ultraviolet spectral range and thus, for example, the characterization of depolarizing samples. The new instrument was initially used for the characterization of the polarization of the beamline. The technical capabilities of the ellipsometer are demonstrated by a cohesive wide-range measurement of the dielectric function of epitaxially grown ZnO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, performance, and grounding aspects of the International Thermonuclear Experimental Reactor ion cyclotron range of frequencies antenna

ITER's Ion Cyclotron Range of Frequencies (ICRF) system [Lamalle et al., Fusion Eng. Des. 88, 517–520 (2013)] comprises two antenna launchers designed by CYCLE (a consortium of European associations listed in the author affiliations above) on behalf of ITER Organisation (IO), each inserted as a Port Plug (PP) into one of ITER's Vacuum Vessel (VV) ports. Each launcher is an array of 4 toroidal by 6 poloidal RF current straps specified to couple up to 20 MW in total to the plasma in the frequency range of 40 to 55 MHz but limited to a maximum system voltage of 45 kV and limits on RF electric fields depending on their location and direction with respect to, respectively, the torus vacuum and the toroidal magnetic field. A crucial aspect of coupling ICRF power to plasmas is the knowledge of the plasma density profiles in the Scrape-Off Layer (SOL) and the location of the RF current straps with respect to the SOL. The launcher layout and details were optimized and its performance estimated for a worst case SOL provided by the IO. The paper summarizes the estimated performance obtained within the operational parameter space specified by IO. Aspects of the RF grounding of the whole antenna PP to the VV port and the effect of the voids between the PP and the Blanket Shielding Modules (BSM) surrounding the antenna front are discussed. These blanket modules, whose dimensions are of the order of the ICRF wavelengths, together with the clearance gaps between them will constitute a corrugated structure which will interact with the electromagnetic waves launched by ICRF antennas. The conditions in which the grooves constituted by the clearance gaps between the blanket modules can become resonant are studied. Simple analytical models and numerical simulations show that mushroom type structures (with larger gaps at the back than at the front) can bring down the resonance frequencies, which could lead to large voltages in the gaps between the blanket modules and perturb the RF properties of the antenna if they are in the ICRF operating range. The effect on the wave propagation along the wall structure, which is acting as a spatially periodic (toroidally and poloidally) corrugated structure, and hence constitutes a slow wave structure modifying the wall boundary condition, is examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dielectric function in the spectral range (0.5–8.5)eV of an (Al{sub x}Ga{sub 1−x}){sub 2}O{sub 3} thin film with continuous composition spread

We determined the dielectric function of the alloy system (Al{sub x}Ga{sub 1−x}){sub 2}O{sub 3} by spectroscopic ellipsometry in the wide spectral range from 0.5 eV to 8.5 eV and for Al contents ranging from x = 0.11 to x = 0.55. For the composition range x < 0.4, we observe single phase material in the β-modification and for larger Al content also the occurrence of γ-(Al,Ga){sub 2}O{sub 3}. We derived spectra of the refractive index and the absorption coefficient as well as energy parameters of electronic band-band transitions by model analysis of the dielectric function. The dependence of the dielectric functions lineshape and the energy parameters on x is highly continuous, reflecting theoretical expectations. The data presented here provide a basis for a deeper understanding of the electronic properties of this material system and may be useful for device engineering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of different frequency ranges in scanning electron microscope images

We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dissociation and ionization equilibria of deuterium fluid over a wide range of temperatures and densities

We investigate the dissociation and ionization equilibria of deuterium fluid over a wide range of temperatures and densities. The partition functions for molecular and atomic species are evaluated, in a statistical-mechanically consistent way, implementing recent developments in the literature and taking high-density effects into account. A new chemical model (free energy function) is introduced in which the fluid is considered as a mixture of diatomic molecules, atoms, ions, and free electrons. Intensive short range hard core repulsion is taken into account together with partial degeneracy of free electrons and Coulomb interactions among charged particles. Samples of computational results are presented as a set of isotherms for the degree of ionization, dissociated fraction of molecules, pressure, and specific internal energy for a wide range of densities and temperatures. Predictions from the present model calculations show an improved and sensible physical behavior compared to other results in the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Narrow-band near-field nanoscopy in the spectral range from 1.3 to 8.5 THz

Nano-spectroscopy in the terahertz frequency range remains challenging despite recent technological progress in developing both THz emitter sources and near-field optical microscopy (SNOM). Here, we combine scattering-type SNOM with a free-electron laser light source, to tune into the 1.3–8.5 THz range. A significant portion of this range, namely, the frequencies above ∼3 THz, is not covered by previously reported near-field microscopy systems. However, it constitutes an indispensable regime where many elementary processes in solids including collective lattice excitations, charge, and spin transport occur. Our approach of nano-spectroscopy and nano-imaging provides a versatile analysis of nanostructures as small as 50 nm, hence beating the optical diffraction limit by λ/4600.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validating data analysis of broadband laser ranging

Broadband laser ranging combines spectral interferometry and a dispersive Fourier transform to achieve high-repetition-rate measurements of the position of a moving surface. Telecommunications fiber is a convenient tool for generating the large linear dispersions required for a dispersive Fourier transform, but standard fiber also has higher-order dispersion that distorts the Fourier transform. Imperfections in the dispersive Fourier transform significantly complicate the ranging signal and must be dealt with to make high-precision measurements. Here, we describe in detail an analysis process for interpreting ranging data when standard telecommunications fiber is used to perform an imperfect dispersive Fourier transform. This analysis process is experimentally validated over a 27-cm scan of static positions, showing an accuracy of 50 μm and a root-mean-square precision of 4.7 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-range forces: atmospheric neutrino oscillation at a magnetized detector

Among the combinations L{sub e}-L{sub μ}, L{sub e}-L{sub τ} and L{sub μ}-L{sub τ} any one can be gauged in anomaly free way with the standard model gauge group. The masses of these gauge bosons can be so light that it can induce long-range forces on the Earth due to the electrons in the Sun. This type of forces can be constrained significantly from neutrino oscillation. As the sign of the potential is opposite for neutrinos and antineutrinos, a magnetized iron calorimeter detector (ICAL) would be able to produce strong constraint on it. We have made conservative studies of these long-range forces with atmospheric neutrinos at ICAL considering only the muons of charge current interactions. We find stringent bounds on the couplings α{sub eμ,eτ} ∼< 1.65 × 10{sup −53} at 3σ CL with an exposure of 1 Mton·yr if there is no such force. For nonzero input values of the couplings we find that the potential V{sub eμ} opposes and V{sub eτ} helps to discriminate the mass hierarchy. However, both potentials help significantly to discriminate the octant of θ{sub 23}. The explanation of the anomaly in recent MINOS data (the difference of Δm{sub 32}{sup 2} for neutrinos and antineutrinos), using long-range force originated from the mixing of the gauge boson Z' of L{sub μ}-L{sub τ} with the standard model gauge boson Z, can be tested at ICAL at more than 5σ CL. We have also discussed how to disentangle this from the solution with CPT violation using the seasonal change of the distance between the Earth and the Sun.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exchange functional by a range-separated exchange hole

An approximation to the exchange-hole density is proposed for the evaluation of the exact exchange energy in electronic structure calculations within the density-functional theory and the Kohn-Sham scheme. Based on the localized nature of density matrix, the exchange hole is divided into the short-range (SR) and long-range (LR) parts by using an adequate filter function, where the LR part is deduced by matching of moments with the exactly calculated SR counterpart, ensuring the correct asymptotic -1/r behavior of the exchange potential. With this division, the time-consuming integration is truncated at a certain interaction range, largely reducing the computation cost. The total energies, exchange energies, exchange potentials, and eigenvalues of the highest-occupied orbitals are calculated for the noble-gas atoms. The close agreement of the results with the exact values suggests the validity of the approximation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New consistency tests for high-accuracy measurements of X-ray mass attenuation coefficients by the X-ray extended-range technique

An extension of the X-ray extended-range technique is described for measuring X-ray mass attenuation coefficients by introducing absolute measurement of a number of foils - the multiple independent foil technique. Illustrating the technique with the results of measurements for gold in the 38-50 keV energy range, it is shown that its use enables selection of the most uniform and well defined of available foils, leading to more accurate measurements; it allows one to test the consistency of independently measured absolute values of the mass attenuation coefficient with those obtained by the thickness transfer method; and it tests the linearity of the response of the counter and counting chain throughout the range of X-ray intensities encountered in a given experiment. In light of the results for gold, the strategy to be ideally employed in measuring absolute X-ray mass attenuation coefficients, X-ray absorption fine structure and related quantities is discussed.

58 GEOSCIENCES↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Characteristics of an OSLD in the diagnostic energy range

Purpose: Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. Methods: NanoDot OSL dosimeters (OSLDs) were used in this study, which started with testing the homogeneity of a new packet of nanoDots. Reproducibility and the effect of optical treatment (bleaching) were then examined, followed by an investigation of the effect of accumulated dose on the OSLD indicated doses. OSLD linearity, angular dependence, and energy dependence were also studied. Furthermore, comparison with LiF:Mg,Ti TLD chips using standard CT dose phantoms at 80 and 120 kVp settings was performed. Results: Batch homogeneity showed a coefficient of variation of <5%. Single-irradiation measurements with bleaching after each OSL readout was found to be associated with a 3.3% reproducibility (one standard deviation measured with a 8 mGy test dose), and no systematic change in OSLDs sensitivity could be noted from measurement to measurement. In contrast, the multiple-irradiation readout without bleaching in between measurements was found to be associated with an uncertainty (using a 6 mGy test dose) that systematically increased with accumulated dose, reaching 42% at 82 mGy. Good linearity was shown by nanoDots under general x-ray, CT, and mammography units with an R{sup 2} > 0.99. The angular dependence test showed a drop of approximately 70% in the OSLD response at 90 deg. in mammography (25 kVp). With the general radiography unit, the maximum drop was 40% at 80 kVp and 20% at 120 kVp, and it was only 10% with CT at both 80 and 120 kVp. The energy dependence study showed a range of ion chamber-to-OSLDs ratios between 0.81 and 1.56, at the energies investigated (29-62 keV). A paired t-test for comparing the OSLDs and TLDs showed no significant variation (p > 0.1). Conclusions: OSLDs exhibited good batch homogeneity (<5%) and reproducibility (3.3%), as well as a linear response. In addition, they showed no statistically significant difference with TLDs in CT measurements (p > 0.1). However, high uncertainty (42%) in the dose estimate was found as a result of relatively high accumulated dose. Furthermore, nanoDots showed high angular dependence (up to 70%) in low kVp techniques. Energy dependence of about 60% was found, and correction factors were suggested for the range of energies investigated. Therefore, if angular and energy dependences are taken into consideration and the uncertainty associated with accumulated dose is avoided, OSLDs (nanoDots) can be suitable for use as point dosimeters in diagnostic settings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP2-13: Patient-Specific Reduction of Range Uncertainties in Proton Therapy by Proton Radiography with a Multi-Layer Ionization Chamber

Purpose: The conversion from Hounsfield units (HU) to stopping powers is a major source of range uncertainty in proton therapy (PT). Our contribution shows how proton radiographs (PR) acquired with a multi-layer ionization chamber in a PT center can be used for accurate patient positioning and subsequently for patient-specific optimization of the conversion from HU to stopping powers. Methods: A multi-layer ionization chamber was used to measure the integral depth-dose (IDD) of 220 MeV pencil beam spots passing through several anthropomorphic phantoms. The whole area of interest was imaged by repositioning the couch and by acquiring a 45×45 mm{sup 2} frame for each position. A rigid registration algorithm was implemented to correct the positioning error between the proton radiographs and the planning CT. After registration, the stopping power map obtained from the planning CT with the calibration curve of the treatment planning system was used together with the water equivalent thickness gained from two proton radiographs to generate a phantom-specific stopping power map. Results: Our results show that it is possible to make a registration with submillimeter accuracy from proton radiography obtained by sending beamlets separated by more than 1 mm. This was made possible by the complex shape of the IDD due to the presence of lateral heterogeneities along the path of the beam. Submillimeter positioning was still possible with a 5 mm spot spacing. Phantom specific stopping power maps obtained by minimizing the range error were cross-verified by the acquisition of an additional proton radiography where the phantom was positioned in a random but known manner. Conclusion: Our results indicate that a CT-PR registration algorithm together with range-error based optimization can be used to produce a patient-specific stopping power map. Sylvain Deffet reports financial funding of its PhD thesis by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work. Francois Vander Stappen reports being employed by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work.

60 APPLIED LIFE SCIENCES↗

Poster - 16: Time-resolved diode dosimetry for in vivo proton therapy range verification: calibration through numerical modeling

Purpose: A method to refine the implementation of an in vivo, adaptive proton therapy range verification methodology was investigated. Simulation experiments and in-phantom measurements were compared to validate the calibration procedure of a time-resolved diode dosimetry technique. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification by correlating properties of the detector signal to the water equivalent path length (WEPL). The implementation of this system requires a set of calibration measurements to establish a beam-specific diode response to WEPL fit for the selected ‘scout’ beam in a solid water phantom. This process is both tedious, as it necessitates a separate set of measurements for every ‘scout’ beam that may be appropriate to the clinical case, as well as inconvenient due to limited access to the clinical beamline. The diode response to WEPL relationship for a given ‘scout’ beam may be determined within a simulation environment, facilitating the applicability of this dosimetry technique. Measurements for three ‘scout’ beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). Results: Detector response in water equivalent plastic was successfully validated against simulation for spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) with adjusted R{sup 2} of 0.998. Conclusion: Feasibility has been shown for performing calibration of detector response for a given ‘scout’ beam through simulation for the time resolved diode dosimetry technique.

60 APPLIED LIFE SCIENCES↗

An Investigation of the Transmission of Iron-Doped Zinc Selenide in the Terahertz-Frequency Range

We present the results of our experimental investigation of the transmission of plates of zinc-selenide crystal doped with iron at a level of 0.23 mass % in the terahertz-frequency range and compare them with the transmission of undoped samples. We show that the presence of iron impurities in a zinc-selenide sample makes the medium more transparent in the frequency range from 0.35 to 0.5 THz. The transmission of a doped sample in this range increases to 20% compared to pure ZnSe. This result can be used in the future to create efficient devices for controlling terahertz radiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗