Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Deep medical image analysis with representation learning and neuromorphic computing

Deep learning is increasingly used in medical imaging, improving many steps of the processing chain, from acquisition to segmentation and anomaly detection to outcome prediction. Yet significant challenges remain: (i) image-based diagnosis depends on the spatial relationships between local patterns, something convolution and pooling often do not capture adequately; (ii) data augmentation, the de facto method for learning three-dimensional pose invariance, requires exponentially many points to achieve robust improvement; (iii) labelled medical images are much less abundant than unlabelled ones, especially for heterogeneous pathological cases; and (iv) scanning technologies such as magnetic resonance imaging can be slow and costly, generally without online learning abilities to focus on regions of clinical interest. To address these challenges, novel algorithmic and hardware approaches are needed for deep learning to reach its full potential in medical imaging.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-11: Tumor Tracking in An Iterative Volume of Interest Based 4D CBCT Reconstruction

Purpose: 4D CBCT can allow evaluation of tumor motion immediately prior to radiation therapy, but suffers from heavy artifacts that limit its ability to track tumors. Various iterative and compressed sensing reconstructions have been proposed to reduce these artifacts, but are costly time-wise and can degrade the image quality of bony anatomy for alignment with regularization. We have previously proposed an iterative volume of interest (I4D VOI) method which minimizes reconstruction time and maintains image quality of bony anatomy by focusing a 4D reconstruction within a VOI. The purpose of this study is to test the tumor tracking accuracy of this method compared to existing methods. Methods: Long scan (8–10 mins) CBCT data with corresponding RPM data was collected for 12 lung cancer patients. The full data set was sorted into 8 phases and reconstructed using FDK cone beam reconstruction to serve as a gold standard. The data was reduced in way that maintains a normal breathing pattern and used to reconstruct 4D images using FDK, low and high regularization TV minimization (λ=2,10), and the proposed I4D VOI method with PTVs used for the VOI. Tumor trajectories were found using rigid registration within the VOI for each reconstruction and compared to the gold standard. Results: The root mean square error (RMSE) values were 2.70mm for FDK, 2.50mm for low regularization TV, 1.48mm for high regularization TV, and 2.34mm for I4D VOI. Streak artifacts in I4D VOI were reduced compared to FDK and images were less blurred than TV reconstructed images. Conclusion: I4D VOI performed at least as well as existing methods in tumor tracking, with the exception of high regularization TV minimization. These results along with the reconstruction time and outside VOI image quality advantages suggest I4D VOI to be an improvement over existing methods. Funding support provided by CPRIT grant RP110562-P2-01.

60 APPLIED LIFE SCIENCES↗

Oscillating paramagnetic Meissner effect and Berezinskii-Kosterlitz-Thouless transition in underdoped Bi2Sr2CaCu2O8+δ

ABSTRACT Superconducting phase transitions in two dimensions lie beyond the description of the Ginzburg-Landau symmetry-breaking paradigm for three-dimensional superconductors. They are Berezinskii-Kosterlitz-Thouless (BKT) transitions of paired-electron condensate driven by the unbinding of topological excitations, i.e. vortices. The recently discovered monolayers of layered high-transition-temperature (${{{T}}}_{{\rm C}}$) cuprate superconductor Bi2Sr2CaCu2O8+δ (Bi2212) meant that this 2D superconductor promised to be ideal for the study of unconventional superconductivity. But inhomogeneity posed challenges for distinguishing BKT physics from charge correlations in this material. Here, we utilize the phase sensitivity of scanning superconducting quantum interference device microscopy susceptometry to image the local magnetic response of underdoped Bi2212 from the monolayer to the bulk throughout its phase transition. The monolayer segregates into domains with independent phases at elevated temperatures below ${{{T}}}_{{\rm C}}$. Within a single domain, we find that the susceptibility oscillates with flux between diamagnetism and paramagnetism in a Fraunhofer-like pattern up to ${{{T}}}_{{\rm C}}$. The finite modulation period, as well as the broadening of the peaks when approaching ${{{T}}}_{{\rm C}}$ from below, suggests well-defined vortices that are increasingly screened by the dissociation of vortex-antivortex plasma through a BKT transition. In the multilayers, the susceptibility oscillation differs in a small temperature regime below ${{{T}}}_{{\rm C}}$, consistent with a dimensional crossover led by interlayer coupling. Serving as strong evidence for BKT transition in the bulk, we observe a sharp jump in phase stiffness and paramagnetism at small fields just below ${{{T}}}_{{\rm C}}$. These results unify the superconducting phase transitions from the monolayer to the bulk underdoped Bi2212, and can be collectively referred to as the BKT transition with interlayer coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sulfur dimers adsorbed on Au(111) as building blocks for sulfur octomers formation: A density functional study

Experimental scanning tunneling microscopy (STM) studies have shown for more than two decades rectangular formations when sulfur atoms are deposited on Au(111) surfaces. The precursors have ranged from simple molecules or ions, such as SO{sub 2} gas or sulfide anions, to more complex organosulfur compounds. We investigated, within the framework of the Density Functional Theory, the structure of these rectangular patterns assuming them entirely composed of sulfur atoms as the experimental evidence suggests. The sulfur coverage at which the simulations were carried out (0.67 ML or higher) provoked that the sulfur-sulfur association had to be taken into account for achieving a good agreement between the sets of simulated and experimental STM images. A combination of four sulfur dimers per rectangular formation properly explained the trends obtained by the experimental STM analysis which were related with the rectangles' size and shape fluctuations together with sulfur-sulfur distances within these rectangles. Finally, a projected density of states analysis showed that the dimers were capable of altering the Au(5d) electronic states at the same level as atomic sulfur adsorbed at low coverage. Besides, sulfur dimers states were perfectly distinguished, whose presence near and above the Fermi level can explain both: sulfur-sulfur bond elongation and dimers stability when they stayed adsorbed on the surface at high coverage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mapping structural heterogeneity at the nanoscale with scanning nano-structure electron microscopy (SNEM)

Here, in this work, we explore the use of scanning electron diffraction (also known as 4D-STEM) coupled with electron atomic pair distribution function analysis (ePDF) to understand the local order (structure and chemistry) as a function of position in a complex multicomponent system, a hot rolled, Ni-encapsulated, Zr 65 Cu 17.5 Ni 10 Al 7.5 bulk metallic glass (BMG), with a spatial resolution of 3 nm. We show that it is possible to gain insight into the chemistry and chemical clustering/ordering tendency in different regions of the sample, including in the vicinity of nano-scale crystallites that are identified from virtual dark field images and in heavily deformed regions at the edge of the BMG. In addition to simpler analysis, unsupervised machine learning was used to extract partial PDFs from the material, modeled as a quasi-binary alloy, and map them in space. These maps allowed key insights not only into the local average composition, as validated by EELS, but also a unique insight into chemical short-range ordering tendencies in different regions of the sample during formation. The experiments are straightforward and rapid and, unlike spectroscopic measurements, don’t require energy filters on the instrument. We spatially map different quantities of interest (QoI’s), defined as scalars that can be computed directly from positions and widths of ePDF peaks or parameters refined from fits to the patterns. We developed a flexible and rapid data reduction and analysis software framework that allows experimenters to rapidly explore images of the sample on the basis of different QoI’s. The power and flexibility of this approach are explored and described in detail. Because of the fact that we are getting spatially resolved images of the nanoscale structure obtained from ePDFs we call this approach scanning nano-structure electron microscopy (SNEM), and we believe that it will be powerful and useful extension of current 4D-STEM methods.

36 MATERIALS SCIENCE↗

Nanoscale Imaging of Magnetotransport around a Circular 𝑝−𝑛 Junction in Graphene

Magnetoresistance studies of 2D systems are often shaped by the motion of electrons that occupy spatially confined wave functions, such as topological edge modes and disorder-induced bound states. Directly probing how such states form and behave in situ , under applied currents, provides a clear way of connecting microscopic physics to the macroscopic transport response. Here, in this Letter, scanning tunneling potentiometry is used to probe the local, current-induced electrochemical potential of carriers in graphene near circular 𝑝−𝑛 junctions in an out-of-plane magnetic field ranging from 0 to 1.4 T. These measurements provide detailed information about the motion of carriers at the nanometer scale, revealing how it evolves with increasing field. The electrochemical potential displays distinct patterns, such as dipoles, spirals, and concentric disks in weak, moderate, and high fields, respectively. The size and orientation of these patterns can be used to understand how local carrier dynamics change in different transport regimes as well as to directly extract physical parameters such as the electron mean free path and cyclotron diameter.

36 MATERIALS SCIENCE↗

Magnetic and magnetotransport properties of arrays of nanostructured antidots obtained by self-assembling polystyrene nanosphere lithography

A well-ordered nanopatterned structure has been obtained in sputtered magnetic thin films by self-assembling of polystyrene nanospheres. Arrays of holes in Co, Ni, and Ni{sub 80}Fe{sub 20} films having a mean size ranging in the interval of 200-400 nm depending on the experimental condition have been prepared. Sample microstructure has been studied by scanning electron microscopy and atomic force microscopy. Room-temperature hysteresis loops have been measured in the parallel and perpendicular configuration (H{sub max}=20 kOe). Magnetoresistance (MR) measurements have been performed by means of a standard four-contact technique at several angles between the current and the magnetic field (H{sub max}=70 kOe) in the temperature interval of 4-200 K. An anisotropic MR effect has been observed in all compositions independent on the hole mean dimension. The role on magnetic and magnetotransport properties of either sample microstructure or composition has been studied in such patterned structures.

36 MATERIALS SCIENCE↗

Atomistic Mechanics of Torn Back Folded Edges of Triangular Voids in Monolayer WS 2

Triangular nanovoids in 2D materials transition metal dichalcogenides have vertex points that cause stress concentration and lead to sharp crack propagation and failure. Here, the atomistic mechanics of back folding around triangular nanovoids in monolayer WS 2 sheets is examined. Combining atomic-resolution images from annular dark-field scanning transmission electron microscopy with reactive molecular modelling, it is revealed that the folding edge formation has statistical preferences under geometric conditions based on the orientation mismatch. It is further investigated how loading directions and strong interlayer friction, interplay with WS 2 lattice's crack preference, govern the deformation and fracture pattern around folding edges. Finally, these results provide fundamental insights into the combination of fracture and folding in flexible monolayer crystals and the resultant Moiré lattices.

36 MATERIALS SCIENCE↗

Serial millisecond crystallography for routine room-temperature structure determination at synchrotrons

Historically, room-temperature structure determination was succeeded by cryo-crystallography to mitigate radiation damage. Here, we demonstrate that serial millisecond crystallography at a synchrotron beamline equipped with high-viscosity injector and high frame-rate detector allows typical crystallographic experiments to be performed at room-temperature. Using a crystal scanning approach, we determine the high-resolution structure of the radiation sensitive molybdenum storage protein, demonstrate soaking of the drug colchicine into tubulin and native sulfur phasing of the human G protein-coupled adenosine receptor. Serial crystallographic data for molecular replacement already converges in 1,000–10,000 diffraction patterns, which we collected in 3 to maximally 82 minutes. Compared with serial data we collected at a free-electron laser, the synchrotron data are of slightly lower resolution, however fewer diffraction patterns are needed for de novo phasing. Overall, the data we collected by room-temperature serial crystallography are of comparable quality to cryo-crystallographic data and can be routinely collected at synchrotrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hard x-ray nanobeam characterization by coherent diffraction microscopy

We have carried out a ptychographic scanning coherent diffraction imaging experiment on a test object in order to characterize the hard x-ray nanobeam in a scanning x-ray microscope. In addition to a high resolution image of the test object, a detailed quantitative picture of the complex wave field in the nanofocus is obtained with high spatial resolution and dynamic range. Both are the result of high statistics due to the large number of diffraction patterns. The method yields a complete description of the focus, is robust against inaccuracies in sample positioning, and requires no particular shape or prior knowledge of the test object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field-driven sense elements for chirality-dependent domain wall detection and storage

A method for locally sensing and storing data of transverse domain wall chirality in planar nanowire logic and memory systems is presented. Patterned elements, in close proximity to the nanowires, respond to the asymmetry in the stray field from the domain wall to produce a chirality-dependent response. When a bias field is applied, a stray field-assisted reversal of the element magnetization results in a reversed remanent state, measurable by scanning electron microscopy with polarization analysis (SEMPA). The elements are designed as triangles with tips pointing toward the nanowire, allowing the shape anisotropy to be dominated by the base but having a portion with lower volume and lower energy barrier closest to the domain wall. Micromagnetic modeling assists in the design of the nanowire-triangle systems and experiments using SEMPA confirm the importance of aspect ratio and spacing given a constant bias field magnitude.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-G-JeP3-09: Tumor Location Prediction Using Natural Respiratory Volume for Respiratory Gated Radiation Therapy (RGRT): System Verification Study

Purpose: Respiratory gated radiation therapy (RGRT) gives accurate results when a patient’s breathing is stable and regular. Thus, the patient should be fully aware during respiratory pattern training before undergoing the RGRT treatment. In order to bypass the process of respiratory pattern training, we propose a target location prediction system for RGRT that uses only natural respiratory volume, and confirm its application. Methods: In order to verify the proposed target location prediction system, an in-house phantom set was used. This set involves a chest phantom including target, external markers, and motion generator. Natural respiratory volume signals were generated using the random function in MATLAB code. In the chest phantom, the target takes a linear motion based on the respiratory signal. After a four-dimensional computed tomography (4DCT) scan of the in-house phantom, the motion trajectory was derived as a linear equation. The accuracy of the linear equation was compared with that of the motion algorithm used by the operating motion generator. In addition, we attempted target location prediction using random respiratory volume values. Results: The correspondence rate of the linear equation derived from the 4DCT images with the motion algorithm of the motion generator was 99.41%. In addition, the average error rate of target location prediction was 1.23% for 26 cases. Conclusion: We confirmed the applicability of our proposed target location prediction system for RGRT using natural respiratory volume. If additional clinical studies can be conducted, a more accurate prediction system can be realized without requiring respiratory pattern training.

60 APPLIED LIFE SCIENCES↗

Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high resolution scanning electron microscope for in situ investigation of swift heavy ion induced modification of solid surfaces

A new in situ high resolution electron microscope (HRSEM) setup has been designed and integrated into the materials science beamline (M-branch) of the universal linear accelerator at Gesellschaft fuer Schwerionenforschung, Darmstadt for in situ investigations of swift heavy ion induced surface modifications. Special ports for in situ experiments are installed at the HRSEM chamber to connect it to the high vacuum beamline, which is equipped with suitable beam control and shaping devices. In order to demonstrate the feasibility and power of this new instrument, first experiments were performed on a 50-nm-thick Fe{sub 2}O{sub 3} film on Si substrate, which exhibited submicrometer size holes due to irradiation induced dewetting in a previous experiment. We have demonstrated that with our new instrument, the development of individual dewetting holes as a function of the ion fluence can be investigated and even the interaction between them can be studied. To illustrate pattern formation during grazing incidence, 3.6 MeV/u {sup 131}Xe ion irradiation was carried out on a 25-nm-thick NiO film on SiO{sub 2}/Si at a tilt angle of 75 deg. The SEM image sequence recorded during the experiment reveals the development of a lamellaelike structure also seen before in ex situ experiments. With our new in situ setup, however, we are able to not only investigate the overall average pattern formation, but also to track the formation and decay of individual linking structures, which would be hardly possible in a standard ex situ experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward In Situ Synchrotron Mapping of Crystal Selection Processes during Crystal Growth

In this work, we present an automated and rapid method for non-destructive mapping of crystal grains in a rod-shaped sample. The approach was designed for application to in situ float-zone crystal growth experiments at an x-ray synchrotron source, but could be useful in other applications. The methods have been tested on a TiO 2 boule grown in an optical float zone furnace. The approach applies a statistical filter to polycrystalline diffraction patterns on 2D detectors to rapidly determine the degree of powder-quality 1of the signal. When larger crystals emerge in the growth, their position, size and shape can be tracked using an automated blob-tracking algorithm that follows individual Bragg peaks as a function of position in a grid-scan, even when multiple crystals are contributing spots to diffraction images. This method is found to be robust as the same crystal shape can be independently reconstructed using different sets of Bragg reflections. Image segmentation methods are then used to map out the polycrystalline grains. We also note that other information about crystal quality, such as mosaicity or strain state, may be inferred and mapped from the intensity variation of the Bragg peaks at different locations within the sample.

36 MATERIALS SCIENCE↗

Bulk and Surface Morphologies of ABC Miktoarm Star Terpolymers Composed of PDMS, PI, and PMMA Arms

DIM miktoarm star copolymers, composed of polydimethylsiloxane [D], poly(1,4-isoprene) [I], and poly(methyl methacrylate) [M], were synthesized using a newly developed linking methodology with 4-allyl-1,1-diphenylethylene as a linking agent. The equilibrium bulk morphologies of the DIM stars were found to range from [6.6.6] tiling patterns to alternating lamellar and alternating cylindrical morphologies, as determined experimentally by small-angle X-ray scattering and transmission electron microscopy and confirmed by dissipative particle dynamics and self-consistent field theory based arguments. The thin film morphologies, which differ from those found in the bulk, were identified by scanning electron microscopy, coupled with oxygen plasma etching. Finally, square arrays of the PDMS nanodots and empty core cylinders were formed on silica after oxygen plasma removal of the poly(1,4-isoprene) and poly(methyl methacrylate) which generated nanostructured substrates decorated with these features readily observable.

36 MATERIALS SCIENCE↗

Hard x-ray phase contrast imaging using single absorption grating and hybrid semiconductor pixel detector

A method for x-ray phase contrast imaging is introduced in which only one absorption grating and a microfocus x-ray source in a tabletop setup are used. The method is based on precise subpixel position determination of the x-ray pattern projected by the grating directly from the pattern image. For retrieval of the phase gradient and absorption image (both images obtained from one exposure), it is necessary to measure only one projection of the investigated object. Thus, our method is greatly simplified compared with the phase-stepping method and our method can significantly reduce the time-consuming scanning and possibly the unnecessary dose. Furthermore, the technique works with a fully polychromatic spectrum and gives ample variability in object magnification. Consequently, the approach can open the way to further widespread application of phase contrast imaging, e.g., into clinical practice. The experimental results on a simple testing object as well as on complex biological samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic imaging of materials under unconventional circumstances

This paper reflects the contents of the plenary talk given by Nico Felicien Declercq. “Ultrasonic Imaging of materials” covers a wide technological area with main purpose to look at and to peek inside materials. In an ideal world one would manage to examine materials like a clairvoyant. Fortunately this is impossible hence nature has offered sufficient challenges to mankind to provoke curiosity and to develop science and technology. Here we focus on the appearance of certain undesired physical effects that prohibit direct imaging of materials in ultrasonic C-scans. Furthermore we try to make use of these effects to obtain indirect images of materials and therefore make a virtue of necessity. First we return to one of the oldest quests in the progress of mankind: how thick is ice? Our ancestors must have faced this question early on during migration to Northern Europe and to the America’s and Asia. If a physicist or engineer is not provided with helpful tools such as a drill or a device based on ultrasound, it is difficult to determine the ice thickness. Guided waves, similar to those used for nondestructive testing of thin plates in structural health monitoring can be used in combination with the human ear to determine the thickness of ice. To continue with plates, if an image of its interior is desired high frequency ultrasonic pulses can be applied. It is known by the physicist that the resolution depends on the wavelength and that high frequencies usually result in undesirably high damping effects inhibiting deep penetration into the material. To the more practical oriented engineer it is known that it is advantageous to polish surfaces before examination because scattering and diffraction of sound lowers the image resolution. Random scatterers cause some blurriness but cooperating scatters, causing coherent diffraction effects similar to the effects that cause DVD’s to show rainbow patterns under sunlight, can cause spooky images and erroneous measurements of material properties. However when properly understood, diffraction effects, for instance if one has no other options but to work with frequencies that are fortuitously very effectively diffracted by the surface structure of a material under investigation, can be used to obtain high contract images or to obtain information that would normally be hidden from standard C-scan techniques. Similar contrast enhancement is also obtained for oblique C-scans of composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗