Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Remote Sensing System Requirements Development: A Simulation-Based Approach

Earth science research and application requirements for multispectral data have often been driven by currently available remote sensing technology. Few parametric studies exist that specify data required for certain applications. Consequently, data requirements are often defined based on the best data available or on what has worked successfully in the past. Since properites such as spatial resolution, swath width, spectral bands, signal-to-noise ratio (SNR), data quantization, and band-to-band registration drive sensor platform and spaceraft system architecture and cost, analysis of these criteria is important to objectively optimize system design. Remote sensing data requirements are also linked to calibration and characterization methods. Parameters such as spatial resolution, radiometric accuracy, and geopositional accuracy affect the complexity and cost of calibration methods. However, there are few studies that quantify the true accuracies required for specific problems. As calibration methods and standards are proposed, it is important that they be tied to well-known data requirements. The Application Research Toolbox (ART) developed at Stennis Space Center provides a simulation-based method for multispectral data requirements development. The ART produces simulated data sets from hyperspectral data through band synthesis. Parameters such as spectral band shape and width, SNR, data quantization, spatial resolution, and band-to-band registration can be varied to create many different simulated data products. Simulated data utility can then be assessed for different applications so that requirements can be better understood. This paper describes the ART and its applicability for rigorously deriving remote sensing data requirements.

Zanoni, Vicki↗

Kelvin Probe Force Microscopy for High-Resolution Imaging of Hydrogen in Steel and Aluminum Alloys (Q3 Progress Report)

SRNL is working with Sandia NL, Pacific Northwest NL and Oak Ridge NL in the H-Mat consortium with the objective of developing materials with a higher resistance to hydrogen attack. Understanding the mechanism of hydrogen interactions in metal alloys is continually a topic of interest for applications which involve the long-term storage of hydrogen. Atomic hydrogen segregates to regions of extended defects, such as grain and phase boundaries, and can cause stress and premature cracking through a process known as hydrogen embrittlement. Advanced microstructural imaging techniques, with minimal sample preparation needs, that are capable of resolving hydrogen segregation at the nanometer scale is needed. Current imaging technologies to aid in understanding the effects of hydrogen in metals involve primarily fractography after mechanical testing. Hydrogen segregated at the surface and particularly at surface defect sites changes the local work function of the material. This can be measured by Kelvin Probe Force Microscopy, KPFM, a variant of atomic force microscopy (AFM). KPFM produces surface potential images and is capable of measuring the local change in work function of surfaces with very high spatial resolution. The spatial resolution of KPFM is optimally ~5 nm, yielding very high hydrogen concentration/microstructure coloration capabilities. By locating the presence of hydrogen and its relationship with extended defects, it may be possible to develop microstructures less susceptible to hydrogen embrittlement. The objective of this effort is to assess the utility of KPFM to determine the H 2 concentration profiles surrounding complex microstructural features in high strength steel and aluminum alloys subjected to high pressure hydrogen exposure.

08 HYDROGEN↗

Study of SXR/EUV radiation of exploded foils and wires with spectral, spatial and temporal resolution simultaneously on KING electric discharge facility.

The results of studies of the soft X-ray and extreme ultraviolet (SXR/EUV) radiation of thin flat aluminum foils and wires under the explosion in an electric discharge on the compact high-current KING generator are presented. These studies were based on the SXR/EUV spectroscopy with a spectral resolution of 6 Å, a temporal resolution of 5 ns and a spatial resolution of 200 μm. To study the plasma radiation of exploded foils and wires in the SXR/EUV range, we used a transmission diffraction grating spectrograph which in combination with two additional slits provided spectral and spatial resolution. The spectrograph was coupled with a 4-frame recorder based on a microchannel plate for providing temporal resolution. The analysis and comparison of the spectral, spatial, temporal, and energy characteristics of the SXR/EUV radiation of plasma formed under the explosion of foils and wires of a similar mass made of aluminum was carried out. Here, the spectra were calculated as well and the plasma parameters and their changes in time and space were estimated on the basis of these calculations and comparison with relevant experimental results. Experiments have shown that when foils explode, a single intense source of SXR/EUV radiation is formed with radiated energy in the range of 10-20 J and a power of up to 100 MW in the quantum energy range from 30 to 250 eV. At the same time, the radiation power under the explosion of foils turned out to be about twice above the power under the explosion of wires of comparable mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Design and development of conical X-ray imaging mirrors

The basic principles for the design of conical optics, and the development of an arc-minute quality conical mirror are described. Computer ray tracing data for over 100 conical mirror designs are analyzed in order to study the intrinsic capabilities of conical mirrors; the intrinsic spatial resolution and approximate filling factor are considered. The procedures for the fabrication of a conical mirror for the Broad-Band X-ray Telescope experiment to be flown on the Shuttle are examined. A f/10 conical mirror with 3.8 m focal length and a filling factor of about 60 percent, consisting of 18 nested reflector pairs has been developed. The difference between the intrinsic and measured half-power radii is investigated. Methods for improving the spatial resolution of conical mirrors are being researched. The advantages and disadvantages of conical mirrors are discussed. It is noted that conical mirrors are applicable for studies in which a broad bandpass, moderate spatial resolution, and a small number of mirrors are required.

Petre, R.↗

The Critical Need for Continued Data Collection and Development of Future Thermal Satellite Sensors

There is a rich and long history of thermal infrared (TIR) remote sensing data for multidisciplinary Earth science research. The continuity of TIR data collection, however, is now in jeopardy given there are no planned future Earth observing TIR remote sensing satellite systems with moderately high spatial resolutions to replace those currently in orbit on NASA's Terra suite of sensors. This session will convene researchers who have actively worked in the field of TIR remote sensing to present results that elucidate the importance of thermal remote sensing to the wider Earth science research community. Additionally, this session will also exist as a forum for presenting concepts and ideas for new thermal sensing systems with high spatial resolutions for future Earth science satellite missions, as opposed to planned systems such as the Visible/Infrared Imager/Radiometer (VIIRS) suite of sensors on the National Polar-orbiting Operational Environmental Satellite System (NPOESS) that will collect TIR data at very coarse spatial resolutions.

Quattrochi, Dale A.↗

Advanced coal gasifier designs using large-scale simulations

Porting of the legacy code MFIX to a high performance computer (HPC) and the useof high resolution simulations for the design of a coal gasifier are described here. MFIX isbased on a continuum multiphase flow model that considers gas and solids to forminterpenetrating continua. Low resolution simulations of a commercial scale gasifier with avalidated MFIX model revealed interesting physical phenomena with implications on thegasifier design, which prompted the study reported here. To be predictive, the simulations needto model the spatiotemporal variations in gas and solids volume fractions, velocities,temperatures with any associated phase change and chemical reactions. These processes occurat various time- and length-scales requiring very high spatial resolution and large number ofiterations with small time-steps. We were able to perform perhaps the largest knownsimulations of gas-solids reacting flows, providing detailed information about the gas-solidsflow structure and the pressure, temperature and species distribution in the gasifier. One keyfinding is the new features of the coal jet trajectory revealed with the high spatial resolution,which provides information on the accuracy of the lower resolution simulations.Methodologies for effectively combining high and low resolution simulations for designstudies must be developed. From a computational science perspective, we found that globalcommunication has to be reduced to achieve scalability to 1000s of cores, hybridparallelization is required to effectively utilize the multicore chips, and the wait time in thebatch queue significantly increases the actual time-to-solution. From our experience,development is required in the following areas: efficient solvers for heterogeneous, massivelyparallel systems; data analysis tools to extract information from large data sets; andprogramming environments for easily porting legacy codes to HPC.

01 COAL, LIGNITE, AND PEAT↗

The CG-1D neutron imaging beamline at the Oak Ridge National Laboratory High Flux Isotope Reactor

The Oak Ridge National Laboratory Neutron Sciences Directorate has installed a neutron imaging beamline at the High Flux Isotope Reactor (HFIR) cold guide hall. CG-1D is one of the three instruments that make up the CG1 instrument suite. The beamline optics and detector have recently been upgraded to meet the needs of the neutron imaging community (better smoothing of guide system artifacts, higher flux or spatial resolution). These upgrades comprise a new diffuser/aperture system, two new detectors, a He-filled flight tube and silicon (Si) windows. Shielding inside the flight tube, beam scrapers and a beam stop ensure that biological dose is less than 50 Sv/hr outside of the radiation boundary. A set of diffusers and apertures (pinhole geometry) has been installed at the exit of the guide system to allow motorized L/D variation. Samples sit on a translation/rotation stage for alignment and tomography purposes. Detectors for the CG-1D beamline are (1) an ANDOR DW936 charge coupled device (CCD) camera with a field of view of approximately 7 cm x 7 cm and ~ 80 microns spatial resolution and 1 frame per second time resolution, (2) a new Micro-Channel Plate (MCP) detector with a 2.8 cm x 2.8 cm field of view and 55 microns spatial resolution, and 5 s timing capability. 6LiF/ZnS scintillators of thickness varying from 50 to 200 microns are being used at this facility. An overview of the beamline upgrade and preliminary data is presented here.

Santodonato, Louis J↗

The Design of a Remote Sensing Data Acquisition Campaign for Precision Agriculture and Some Early Results

In the 1970s NASA and the Department of Agriculture attempted to use the new Landsat MSS system for agricultural purposes. The program had relatively little success. With the advent of differential GPS, yield monitors on harvest equipment and higher spatial resolution remote sensing systems it seemed likely the situation should be reexamined. Therefore, a campaign of data acquisition involving remote sensing and other modalities with dependent research was assembled and funded by the Space Grant Consortia in Alabama and Georgia. The design of the remote sensing data acquisition was driven by the biology and physics of the crop system and limited by the available sensor platforms. Major parameters included crop stage, spatial resolution, seasonal and daily weather conditions, and which portion of the EM spectrum would actually capture the most discriminating information. Joint visible and Near IR with Thermal IR would permit use of existing indices, such as greenness, as well as phenomena driven by the plant' s evapotranspiration. Spatial resolution in the 2-5 meter range was chosen, avoiding many complexities caused by aliasing crop row spacing at, higher resolutions yet finer than the harvester's tightest recording rate. This dictates use of an airborne system. Use of an airborne system also makes scheduling around weather much simpler than use of satellite data. Active video calibration was recognized as essential if quantitative measures were ever to be obtained or reproduced. The system would also have to have onboard geoOF1 Based on these elements 3 data acquisitions have been flown. Seven flight lines were flown twice in 1998 and 16 lines flown in 1999. Total raw data is several GBytes. All of the data has now been geometrically corrected and some preliminary analysis accomplished. The thermal bands have an extremely high correlation with yield. For one@test case with corn, correlation in excess of 0.86 was obtained from a data acquisition two months prior to harvest! Soil images show significant within field variation in clay, soil brightness and emissivity. Light wind has been found to effect the reflectance and temperature of broad leaf crops, including soybeans, cotton and peanuts. Clearly, this work has already demonstrated some very important results. With continued development of the remote sensing technology there is good reason to believe this research will soon be able to help the individual farmer.

Rickmanl, D.↗

Visualizing nanoscale 3D compositional fluctuation of lithium in advanced lithium-ion battery cathodes

The distribution and concentration of lithium in Li-ion battery cathodes at different stages of cycling is a pivotal factor in determining battery performance. Non-uniform distribution of the transition metal cations has been shown to affect cathode performance; however, the Li is notoriously challenging to characterize with typical high-spatial-resolution imaging techniques. Here, for the first time, laser–assisted atom probe tomography is applied to two advanced Li-ion battery oxide cathode materials—layered Li 1.2 Ni 0.2 Mn 0.6 O 2 and spinel LiNi 0.5 Mn 1.5 O 4 —to unambiguously map the three dimensional (3D) distribution of Li at sub-nanometer spatial resolution and correlate it with the distribution of the transition metal cations (M) and the oxygen. The as-fabricated layered Li 1.2 Ni 0.2 Mn 0.6 O 2 is shown to have Li-rich Li 2 MO 3 phase regions and Li-depleted Li(Ni 0.5 Mn 0.5 )O 2 regions while in the cycled layered Li 1.2 Ni 0.2 Mn 0.6 O 2 an overall loss of Li and presence of Ni rich regions, Mn rich regions and Li rich regions are shown in addition to providing the first direct evidence for Li loss on cycling of layered LNMO cathodes. The spinel LiNi 0.5 Mn 1.5 O 4 cathode is shown to have a uniform distribution of all cations. These results were additionally validated by correlating with energy dispersive spectroscopy mapping of these nanoparticles in a scanning transmission electron microscope. Thus, we have opened the door for probing the nanoscale compositional fluctuations in crucial Li-ion battery cathode materials at an unprecedented spatial resolution of sub-nanometer scale in 3D which can provide critical information for understanding capacity decay mechanisms in these advanced cathode materials.

36 MATERIALS SCIENCE↗

High-sensitivity infrared vibrational nanospectroscopy in water

Mid-infrared vibrational spectroscopy is a universal label-free tool for identifying molecular compounds in chemical and biological samples on the basis of their ‘fingerprint’ vibrational absorption lines. Vibrational spectroscopy with nanometer spatial resolution can reveal the chemical composition of samples at the nanoscale, and several scanning-probe techniques have been developed to address this need. It is also highly desirable to study biological and chemical samples in their native aqueous environments rather than in air. In aqueous environments, however, the sensitivity of the current vibrational nanospectroscopy techniques deteriorates dramatically . Here, we report the first mid-infrared nanospectroscopy technique that retains nanoscale sensitivity and spatial resolution when the sample and the scanning probe are completely immersed in water. This method overcomes challenges including water absorption and scattering and the mechanical damping of cantilever vibrations. We further demonstrate spectroscopy and imaging of 20- to 50-nm-thick polymer samples with a 25-nm spatial resolution in the biologically relevant Amide I and II spectral regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Science Objectives of EOS-Aura's Ozone Monitoring Instrument (OMI)

OMI is a UV/VIS nadir solar backscatter spectrograph, which provides near global coverage in one day with a spatial resolution of 13 x 24 sq km. OMI is a new instrument, with a heritage from the European satellite instruments GOME, GOMOS and SCIAMACHY. OMI's unique capabilities for measuring important trace gases with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will measure solar irradiance and Earth radiances in the wavelength range of 270 to 500 nm with spectral resolution of about 0.5 nm and a spectral sampling of about 2-3 per FWHM. From these observations, total columns of O3, NO2, BrO and SO2 will be derived from the back-scattered solar radiance using differential absorption spectroscopy (DOAS). The TOMS total ozone record will also be continued by employing the well established TOMS algorithm. Because of the high accuracy and spatial resolution of the measurements, a good estimate of tropospheric amounts of ozone and NO2 are expected. Ozone profiles will be derived using the optimal estimation method. The spectral aerosol optical depth will be determined from measurements between 340 and 500 nm. This will provide information on aerosol concentration, aerosol size distribution and aerosol type. This wavelength range makes it possible to retrieve aerosol information over both land and sea. OMI observations will also allow retrievals of cloud coverage and cloud heights. From these products, the UV-B flux at the surface can then be derived with high spatial resolution.

Levelt, P. F.↗

NANCY: Next-generation All-sky Near-infrared Community surveY

The Nancy Grace Roman Space Telescope is capable of delivering an unprecedented all-sky, high-spatial resolution, multi-epoch infrared map to the astronomical community. This opportunity arises in the midst of numerous ground- and space-based surveys that will provide extensive spectroscopy and imaging together covering the entire sky (such as Rubin/LSST, Euclid, UNIONS, SPHEREx, DESI, SDSS-V, GALAH, 4MOST, WEAVE, MOONS, PFS, UVEX, NEO Surveyor, etc.). Roman can uniquely provide uniform high-spatial-resolution (~0.1 arcsec) imaging over the entire sky, vastly expanding the science reach and precision of all of these near-term and future surveys. This imaging will not only enhance other surveys, but also facilitate completely new science. By imaging the full sky over two epochs, Roman can measure the proper motions for stars across the entire Milky Way, probing 100 times fainter than Gaia out to the very edge of the Galaxy. Here, we propose NANCY: a completely public, all-sky survey that will create a high-value legacy dataset benefiting innumerable ongoing and forthcoming studies of the universe. NANCY is a pure expression of Roman's potential: it images the entire sky, at high spatial resolution, in a broad infrared bandpass that collects as many photons as possible. The majority of all ongoing astronomical surveys would benefit from incorporating observations of NANCY into their analyses, whether these surveys focus on nearby stars, the Milky Way, near-field cosmology, or the broader universe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Time-Resolved Observations of Precipitation Structure and Storm Intensity with a Constellation of Smallsats (TROPICS) Mission Applications Workshop Summary Report

The National Aeronautics and Space Administration (NASA) Time-Resolved Observations of Precipitation structure and storm Intensity with a Constellation of SmallSats (TROPICS) mission is a constellation of state-of-the-science observing platforms that will measure temperature and humidity soundings and precipitation with spatial resolution comparable to current operational passive microwave sounders but with unprecedented temporal resolution. TROPICS is a cost-capped ($30 million) Venture-class mission funded by the NASA Earth Science Division (ESD) and led by principal investigator Dr. William Blackwell from the Massachusetts Institute of Technology Lincoln Laboratory (MIT LL). The mission is comprised of a constellation of six, three-unit (3U) Cube-Sats (approximately 10 by 10 by 34 centimeters), each hosting a 12-channel passive microwave spectrometer based on the Micro-sized Microwave Atmospheric Satellite 2 (MicroMAS-2) developed at MIT LL. TROPICS will provide imagery at frequencies near 91 and 205 gigahertz, temperature sounding near 118 gigahertz, and moisture sounding near 183 gigahertz. Spatial resolution at nadir will be around 27 kilometers for temperature and 17 kilometers for moisture and precipitation with a swath width of approximately 2,000 kilometers. Both the spatial resolution and swath width are similar to the Advanced Technology Microwave Sounder (ATMS) that is being flown as part of the Suomi National Polar-Orbiting Partnership and will fly starting in 2017 on the National Oceanic and Atmospheric Administration (NOAA) Joint Polar Satellite System (JPSS). In addition, TROPICS meets many of the requirements outlined in the 2007 Decadal Survey for the Precision and All-Weather Temperature and Humidity mission, which was originally envisioned as a microwave instrument in geostationary orbit. TROPICS enables temporal resolution similar to geostationary orbit but at a much lower cost, demonstrating a technology that could impact the design of future Earth-observing missions. The satellites for the TROPICS mission are slated for delivery to NASA in 2019 for launches planned no earlier than 2020. The primary mission objective of TROPICS is to relate temperature, humidity, and precipitation structure to the evolution of tropical cyclone (TC) intensity.

applied scienc↗

Dot tracking methodology for background-oriented schlieren (BOS)

We propose here a dot tracking methodology for processing background-oriented schlieren (BOS) images. The technique improves the accuracy, precision and spatial resolution compared to conventional cross-correlation algorithms. Our methodology utilizes the prior information about the dot pattern such as the location, size and number of dots to provide near 100% yield even for high dot densities (20 dots/32 × 32 pixels) and is robust to image noise. Furthermore, we propose an improvement to the displacement estimation step in the tracking process, especially for noisy images, using a “correlation correction”, whereby we combine the spatial resolution benefit of the tracking method and the smoothing property of the correlation method to increase the dynamic range of the overall measurement process. We evaluate the performance of the method with synthetic BOS images of buoyancy-driven turbulence rendered using ray-tracing simulations, and experimental images of flow in the exit plane of a converging–diverging nozzle. The results show that the improved spatial resolution results in a better accuracy of the tracking method compared to correlation-based methods in regions with sharp displacement gradients, and the correlation correction step reduces the noise floor of the measurement, resulting in a fourfold improvement in the dynamic range.

42 ENGINEERING↗

A Combined Infrared and Microwave Technique for Studying the Diurnal Variation of Rainfall over Amazonia

Over 10 years of continuous data from the Special Sensor microwave Imager (SSM/I) aboard a series of Defense Department satellites has made it possible to construct regional rainfall climatologies at high spatial resolution. Using the Goddard Profiling Algorithm (GPROF), monthly estimates of precipitation were made over the region of northern Brazil, including the Amazon Basin, for 1987 to 1998. GPROF is a physical approach to passive microwave precipitation retrieval, which uses the Goddard Cumulus Ensemble (cloud) model to establish prior probability densities of precipitation structures. Precipitation fields from GPROF were stratified into morning and evening satellite overpasses, and accumulated at monthly intervals at 0.5 degree spatial resolution. Important diurnal effects were noted in the analysis, the most pronounced being a land/sea breeze circulation along the northern coast of Brazil and a mountain/valley circulation along the Andes. There were also indications of morning rainfall maxima along the major rivers, and evening maxima between the rivers. The addition of simultaneous geosynchronous infrared (IR) data leads to the current technique, which takes advantage of the 30 minute sampling and 4 km spatial resolution of the infrared channel and the better physics of the microwave retrieval. The resultant IR method is subsequently used to derive the diurnal variability of rainfall over the Amazon basin, and further, to investigate the relative contribution from its convective and stratiform components.

Negri, Andrew J.↗

Nanoscale thermal transport. II. 2003–2012

A diverse spectrum of technology drivers such as improved thermal barriers, higher efficiency thermoelectric energy conversion, phase-change memory, heat-assisted magnetic recording, thermal management of nanoscale electronics, and nanoparticles for thermal medical therapies are motivating studies of the applied physics of thermal transport at the nanoscale. This review emphasizes developments in experiment, theory, and computation in the past ten years and summarizes the present status of the field. Interfaces become increasingly important on small length scales. Research during the past decade has extended studies of interfaces between simple metals and inorganic crystals to interfaces with molecular materials and liquids with systematic control of interface chemistry and physics. At separations on the order of ∼1 nm, the science of radiative transport through nanoscale gaps overlaps with thermal conduction by the coupling of electronic and vibrational excitations across weakly bonded or rough interfaces between materials. Major advances in the physics of phonons include first principles calculation of the phonon lifetimes of simple crystals and application of the predicted scattering rates in parameter-free calculations of the thermal conductivity. Progress in the control of thermal transport at the nanoscale is critical to continued advances in the density of information that can be stored in phase change memory devices and new generations of magnetic storage that will use highly localized heat sources to reduce the coercivity of magnetic media. Ultralow thermal conductivity—thermal conductivity below the conventionally predicted minimum thermal conductivity—has been observed in nanolaminates and disordered crystals with strong anisotropy. Advances in metrology by time-domain thermoreflectance have made measurements of the thermal conductivity of a thin layer with micron-scale spatial resolution relatively routine. Scanning thermal microscopy and thermal analysis using proximal probes has achieved spatial resolution of 10 nm, temperature precision of 50 mK, sensitivity to heat flows of 10 pW, and the capability for thermal analysis of sub-femtogram samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-21: Dosimetric Characterization and Image Quality Evaluation of the AIRO Mobile CT Scanner

Purpose: The AIRO Mobile CT system was recently introduced which overcomes the limitations from existing CT, CT fluoroscopy, and intraoperative O-arm. With an integrated table and a large diameter bore, the system is suitable for cranial, spine and trauma procedures, making it a highly versatile intraoperative imaging system. This study is to investigate radiation dose and image quality of the AIRO and compared with those from a routine CT scanner. Methods: Radiation dose was measured using a conventional 100mm pencil ionization chamber and CT polymethylmetacrylate (PMMA) body and head phantoms. Image quality was evaluated with a CATPHAN 500 phantom. Spatial resolution, low contrast resolution (CNR), Modulation Transfer Function (MTF), and Normalized Noise Power Spectrum (NNPS) were analyzed. Results: Under identical technique conditions, radiation dose (mGy/mAs) from the AIRO mobile CT system (AIRO) is higher than that from a 64 slice CT scanner. MTFs show that both Soft and Standard filters of the AIRO system lost resolution quickly compared to the Sensation 64 slice CT. With the Standard kernel, the spatial resolutions of the AIRO system are 3lp/cm and 4lp/cm for the body and head FOVs, respectively. NNPSs show low frequency noise due to ring-like artifacts. Due to a higher dose in terms of mGy/mAs at both head and body FOV, CNR of the AIRO system is higher than that of the Siemens scanner. However detectability of the low contrast objects is poorer in the AIRO due to the presence of ring artifacts in the location of the targets. Conclusion: For image guided surgery applications, the AIRO has some advantages over a routine CT scanner due to its versatility, large bore size, and acceptable image quality. Our evaluation of the physical performance helps its future improvements.

60 APPLIED LIFE SCIENCES↗