Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Shell model analysis of the B ( E 2,2 + → 0 + ) values in the A = 70, T = 1 triplet 70 Kr, 70 Br, and 70 Se

The B(E2, 2 + → 0 + ) transition strengths of the T=1 isobaric triplet 70 Kr, 70 Br, 70 Se, recently measured at the RIKEN Radioactive Isotope Beam Factory (RIBF), are discussed in terms of state-of-the-art large scale shell model calculations using the JUN45 and JUN45 + LNPS plus Coulomb interactions. In this Letter we argue that, depending on the effective charges used, the calculations are either in line with the experimental data within statistical uncertainties, or the anomaly happens in 70 Br, rather than 70 Kr. In the latter case, we suggest that it can be due to the presence of a hitherto undetected 1 + T = 0 state below the yrast 2 + T = 1 state. Furthermore, our results do not support a shape change of 70 Kr with respect to the other members of the isobaric multiplet.

59 ≤ A ≤ 89↗

Measurements of jet quenching using semi-inclusive hadron+jet distributions in 𝑝⁢𝑝 and central Pb-Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

The ALICE Collaboration reports measurements of the semi-inclusive distribution of charged-particle jets recoiling from a high transverse momentum (high pT) charged hadron, in pp and central Pb-Pb collisions at center-of-mass energy per nucleon–nucleon collision $\sqrt{s_{NN}}$ = 5.02 TeV. The large uncorrelated background in central Pb-Pb collisions is corrected using a data-driven statistical approach which enables precise measurement of recoil jet distributions over a broad range in p T,ch jet and jet resolution parameter R. Recoil jet yields are reported for R = 0.2, 0.4, and 0.5 in the range 7 < p T,ch jet < 140 GeV/c and π/2 < φ < π, where φ is the azimuthal angular separation between hadron trigger and recoil jet. The low-p T,ch jet reach of the measurement explores unique phase space for studying jet quenching, the interaction of jets with the quark–gluon plasma generated in high-energy nuclear collisions. Comparison of p T,ch jet distributions from pp and central Pb-Pb collisions probes medium-induced jet energy loss and intra-jet broadening, while comparison of their acopla narity distributions explores in-medium jet scattering and medium response. The measurements are compared to theoretical calculations incorporating jet quenching.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative constraints on the transport properties of hot partonic matter from semi-inclusive single high transverse momentum pion suppression in Au+Au collisions at {radical}(s{sub NN})=200 GeV

The PHENIX experiment has measured the suppression of semi-inclusive single high-transverse-momentum {pi}{sup 0}'s in Au+Au collisions at {radical}(s{sub NN})=200 GeV. The present understanding of this suppression is in terms of energy loss of the parent (fragmenting) parton in a dense color-charge medium. We have performed a quantitative comparison between various parton energy-loss models and our experimental data. The statistical point-to-point uncorrelated as well as correlated systematic uncertainties are taken into account in the comparison. We detail this methodology and the resulting constraint on the model parameters, such as the initial color-charge density dN{sup g}/dy, the medium transport coefficient <q-circumflex>, or the initial energy-loss parameter {epsilon}{sub 0}. We find that high-transverse-momentum {pi}{sup 0} suppression in Au+Au collisions has sufficient precision to constrain these model-dependent parameters at the {+-}20-25% (one standard deviation) level. These constraints include only the experimental uncertainties, and further studies are needed to compute the corresponding theoretical uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved measurements of the β -decay response of liquid xenon with the LUX detector

Here, we report results from an extensive set of measurements of the β-decay response in liquid xenon. These measurements are derived from high-statistics calibration data from injected sources of both 3 H and 14 C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lightest scalar and tensor resonances in {gamma}{gamma}{yields}{pi}{pi} after the Belle experiment

New high statistics Belle data on the {gamma}{gamma}{yields}{pi}{sup +}{pi}{sup -} reaction cross section measured in the range of pion-pair invariant masses {radical}(s) between 0.8 GeV and 1.5 GeV are analyzed to clarify the current situation around the {sigma}(600), f{sub 0}(980), and f{sub 2}(1270) resonances in {gamma}{gamma} collisions. The present analysis shows that the direct coupling constants of the {sigma}(600) and f{sub 0}(980) resonances to {gamma}{gamma} are small, and the {sigma}(600){yields}{gamma}{gamma} and f{sub 0}(980){yields}{gamma}{gamma} decays are four-quark transitions caused by the {pi}{sup +}{pi}{sup -} and K{sup +}K{sup -} loop mechanisms, respectively. The chiral shielding of the {sigma}(600) resonance takes place in the reactions {gamma}{gamma}{yields}{pi}{pi} as well as in {pi}{pi} scattering. Some results of a simultaneous description of the {gamma}{gamma}{yields}{pi}{sup +}{pi}{sup -} and {gamma}{gamma}{yields}{pi}{sup 0}{pi}{sup 0} Belle data are also presented. In particular, the following tentative estimate of the f{sub 2}(1270){yields}{gamma}{gamma} decay width is obtained: {gamma}{sub f{sub 2}}{sub {r_reversible}}{sub {gamma}}{sub {gamma}}(m{sub f{sub 2}}{sup 2}){approx_equal}3.68 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nature of the a{sub 0}(980) meson in the light of photon-photon collisions

New high-statistics Belle data on the reaction {gamma}{gamma}{yields}{pi}{sup 0{eta}} are analyzed to clarify the two-photon production mechanisms and the nature of the a{sub 0}(980) meson. The obtained solution for the amplitude {gamma}{gamma}{yields}{pi}{sup 0{eta}} is consistent with the chiral theory expectation for the {pi}{eta} scattering length, with the strong coupling of the a{sub 0}(980) to the {pi}{eta}, KK, and {pi}{eta}{sup '} channels, and with a key role of the rescattering mechanisms a{sub 0}(980){yields}(KK+{pi}{sup 0{eta}}+{pi}{sup 0{eta}'}){yields}{gamma}{gamma} in the a{sub 0}(980){yields}{gamma}{gamma} decay. Such a picture argues in favor of the q{sup 2}q{sup 2} nature of the a{sub 0}(980) meson and is in agreement with the properties of its partners, the {sigma}{sub 0}(600) and f{sub 0}(980) mesons, in particular, with those that manifest themselves in {gamma}{gamma}{yields}{pi}{pi}. An important role of the vector meson exchanges in the formation of the nonresonant background in {gamma}{gamma}{yields}{pi}{sup 0{eta}} is also revealed. The preliminary information on the reaction {pi}{sup 0{eta}{yields}{pi}0{eta}} is obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of Medium-Induced Yield Enhancement and Acoplanarity Broadening of Low-𝑝T Jets from Measurements in 𝑝⁢𝑝 and Central Pb-Pb Collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

The ALICE Collaboration reports the measurement of semi-inclusive distributions of charged-particle jets recoiling from a high transverse momentum (high p T ) hadron trigger in proton-proton and central Pb-Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV. A data-driven statistical method is used to mitigate the large uncorrelated background in central Pb-Pb collisions. Recoil jet distributions are reported for jet resolution parameter R = 0.2, 0.4, and 0.5 in the range 7 < p T.jet < 140 GeV=c and trigger-recoil jet azimuthal separation π/2 < Δφ < π. The measurements exhibit a marked medium-induced jet yield enhancement at low p T and at large azimuthal deviation from Δφ ~ π. The enhancement is characterized by its dependence on Δφ, which has a slope that differs from zero by 4.7σ. Comparisons to model calculations incorporating different formulations of jet quenching are reported. These comparisons indicate that the observed yield enhancement arises from the response of the QGP medium to jet propagation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Massive compression for high data rate macromolecular crystallography (HDRMX): impact on diffraction data and subsequent structural analysis

New higher-count-rate, integrating, large-area X-ray detectors with framing rates as high as 17400 images per second are beginning to be available. These will soon be used for specialized macromolecular crystallography experiments but will require optimal lossy compression algorithms to enable systems to keep up with data throughput. Some information may be lost. Can we minimize this loss with acceptable impact on structural information? To explore this question, we have considered several approaches: summing short sequences of images, binning to create the effect of larger pixels, use of JPEG-2000 lossy wavelet-based compression, and use of Hcompress, which is a Haar-wavelet-based lossy compression borrowed from astronomy. We also explore the effect of the combination of summing, binning, and Hcompress or JPEG-2000. In each of these last two methods one can specify approximately how much one wants the result to be compressed from the starting file size. These provide particularly effective lossy compressions that retain essential information for structure solution from Bragg reflections.

47 OTHER INSTRUMENTATION↗

Structural Differences between Morning and Evening Peak in Optimized Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grids and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak, depending on controllability of devices. But while controlling water heaters does allow to shift peak, it also results in rebound effects, which require additional understanding before water heater fleets can be used on a large scale. We attempt to investigate the nature of peak behaviors of water heaters and demonstrate that water heaters are not homogenous in their behavior. Depending on the overall intensity of the use of water, part of the population has higher rebound effect, while part of the population has little or no rebound effect. Even though we do not have sufficient data to statistically evaluate our findings, we use a sample of 42 water heaters in a connected neighborhood to provide an early attempt at discovering and reporting this diversity.

Tsybina, Eve↗

Sizing Considerations for EV Dynamic Wireless Charging Systems with Integrated Energy Storage

Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.

Lewis, Donovin D.↗

Interannual variability of ecosystem carbon exchange: From observation to prediction

Here, terrestrial ecosystems have sequestered, on average, the equivalent of 30% of anthropogenic carbon (C) emissions during the past decades, but annual sequestration varies from year to year. For effective C management, it is imperative to develop a predictive understanding of the interannual variability (IAV) of terrestrial net ecosystem C exchange (NEE). Location: Global terrestrial ecosystems. Furthermore, we conducted a comprehensive review to examine the IAV of NEE at global, regional and ecosystem scales. Then we outlined a conceptual framework for understanding how anomalies in climate factors impact ecological processes of C cycling and thus influence the IAV of NEE through biogeochemical regulation. As a result, the phenomenon of IAV in land NEE has been ubiquitously observed at global, regional and ecosystem scales. Global IAV is often attributable to either tropical or semi-arid regions, or to some combination thereof, which is still under debate. Previous studies focus on identifying climate factors as driving forces of IAV, whereas biological mechanisms underlying the IAV of ecosystem NEE are less clear. We found that climate anomalies affect the IAV of NEE primarily through their differential impacts on ecosystem C uptake and respiration. Moreover, recent studies suggest that the carbon uptake period makes less contribution than the carbon uptake amplitude to IAV in NEE. Although land models incorporate most processes underlying IAV, their efficacy to predict the IAV in NEE remains low. In conclusion, to improve our ability to predict future IAV of the terrestrial C cycle, we have to understand biological mechanisms through which anomalies in climate factors cause the IAV of NEE. Future research needs to pay more attention not only to the differential effects of climate anomalies on photosynthesis and respiration but also to the relative importance of the C uptake period and amplitude in causing the IAV of NEE. Ultimately, we need multiple independent approaches, such as benchmark analysis, data assimilation and time-series statistics, to integrate data, modelling frameworks and theory to improve our ability to predict future IAV in the terrestrial C cycle.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-248: Near Real-Time Analysis of Radiation Delivery and Imaging, Accuracy to Ensure Patient Safety

Purpose: To develop and optimize an effective software method for comparing planned to delivered control point machine parameters for all VARIAN TrueBeam treatments so as to permit (1) assessment of a large patient pool throughout their treatment course to quantify treatment technique specific systematic and random uncertainty of observables, (2) quantify the site specific daily imaging shifts required for target alignment, and (3) define tolerance levels for mechanical parameters and imaging parameters based on statistical analysis data gathered, and the dosimetric impact of variations. Methods: Treatment and imaging log files were directly compared to plan parameters for Eclipse and Pinnacle planned treatments via 3D, IMRT, control point, RapidArc, and electrons. Each control point from all beams/arcs (7984) for all fractions (1940) of all patients treated over six months were analyzed. At each control point gantry angle, collimator angle, couch angle, jaw positions, MLC positions, MU were compared. Additionally per-treatment isocenter shifts were calculated. Results were analyzed as a whole in treatment type subsets: IMRT, 3D, RapidArc; and in treatment site subsets: brain, chest/mediastinum, esophagus, H and N, lung, pelvis, prostate. Results: Daily imaging isocenter shifts from initial external tattoo alignment were dependent on the treatment site with < 0.5 cm translational shifts for H and N, Brain, and lung SBRT, while pelvis, esophagus shifts were ∼1 cm. Mechanical delivery parameters were within tolerance levels for all sub-beams. The largest variations were for RapidArc plans: gantry angle 0.11±0.12,collimator angle 0.00±0.00, jaw positions 0.48±0.26, MLC leaf positions 0.66±0.08, MU 0.14±0.34. Conclusion: Per-control point validation reveals deviations between planned and delivered parameters. If used in a near real-time error checking system, patient safety can be improved by equipping the treatment delivery system with additional forcing functions which by-pass human error avenues.

60 APPLIED LIFE SCIENCES↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal growth of phosphopantetheine adenylyltransferase, carboxypeptidase t, and thymidine phosphorylase on the international space station by the capillary counter-diffusion method

Crystals of phosphopantetheine adenylyltransferase from Mycobacterium tuberculosis, thymidine phosphorylase from Escherichia coli, carboxypeptidase T from Thermoactinomyces vulgaris and its mutant forms, and crystals of complexes of these proteins with functional ligands and inhibitors were grown by the capillary counter-diffusion method in the Japanese Experimental Module Kibo on the International Space Station. The high-resolution X-ray diffraction data sets suitable for the determination of high-resolution three-dimensional structures of these proteins were collected from the grown crystals on the SPring-8 synchrotron radiation facility. The conditions of crystal growth for the proteins and the data-collection statistics are reported. The crystals grown in microgravity diffracted to a higher resolution than crystals of the same proteins grown on Earth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Isolating causal pathways between flow and fish in the regulated river hierarchy

Unregulated river systems are organized in a hierarchy in which large-scale factors (i.e., landscape and segment scales) influence local habitats (i.e., reach, meso-, and microhabitat scales), and both differentially exert selective pressures on biota. Dams, however, create discontinua in these processes and change the hierarchical structure. We examined the relative roles of hydrology and other instream factors, within a hierarchical landscape context, in organizing fish communities in regulated and unregulated tributaries to the Upper Tennessee River, USA. We also used multivariate regression trees to identify factors that partition fish assemblages based on trait similarities, irrespective of spatial scale. Then, we used classical path analysis and structural equation modeling to evaluate the most plausible hierarchical causal structure of specific trait-based community components, given the data. Both statistical approaches suggested that river regulation affects stream fishes through a variety of reach-scale variables, not always through hydrology itself. Though we observed different changes in flow, temperature, and biotic responses according to regulation types, the most predominant path in which dam regulation affected biota was via temperature alterations. Diversion dams had the strongest effects on fish assemblages. Diversion dams reduced flow magnitudes, leading to declines in fish richness but increased temperatures, leading to lower abundances in equilibrium species and nest guarders. Peaking and run-of-river dams increased flow variability, leading to lower abundances in nest-guarding fishes. Flow displayed direct relationships with biotic responses; however, results indicated that changes in temperature and substrate had equal, if not stronger, effects on fish assemblage composition. The strength and nature of relationships depended on whether flow metrics were standardized for river size. Here, we suggest that restoration efforts in regulated rivers focus on improving flow conditions in conjunction with temperature and substrate restoration.

58 GEOSCIENCES↗

Probing the strange content of the proton with charm production in charged current at LHeC

Abstract We study charm production in charged-current deep-inelastic scattering (DIS) using the xFitter framework. Recent results from the LHC have focused renewed attention on the determination of the strange-quark parton distribution function (PDF), and the DIS charm process provides important complementary constraints on this quantity. We examine the current PDF uncertainty and use LHeC pseudodata to estimate the potential improvement from this proposed facility. As xFitter implements both fixed-flavor- and variable-flavor-number schemes, we can compare the impact of these different theoretical choices; this highlights some interesting aspects of multi-scale calculations. We find that the high-statistics LHeC data covering a wide kinematic range could substantially reduce the strange PDF uncertainty.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for a critical point of strongly-interacting matter in central \(^{40}\)Ar + \(^{45}\)Sc collisions at 13 A–75 A GeV/c beam momentum

The critical point of strongly interacting matter is searched for at the CERN SPS by the NA61/SHINE experiment in central \(^{40}\)Ar + \(^{45}\)Sc collisions at 13 A, 19 A, 30 A, 40 A, and 75 A GeV/c. The dependence of the second-order scaled factorial moments of proton multiplicity distributions on the number of subdivisions in transverse momentum space is measured. The intermittency analysis uses statistically independent data sets for every subdivision in transverse and cumulative-transverse momentum variables. The results obtained do not indicate the searched intermittent pattern. An upper limit on the fraction of correlated protons and the intermittency index is obtained based on a comparison with the Power-law Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stokhos v 1.0

A Trilinos package for applying stochastic Galerkin uncertainty quantification methods to large-scale C++ application codes, primarily stochastic partial differential equations. Stokhos is intended for use in estimating uncertainties for general scientific computations and is based on published algorithms. It provides no capability for implementing those computations itself. Estimating uncertainties and errors from solution algorithms or simulations, primarily simulations of partial differential equations, arising from uncertainties or errors in solution algorithm or simulation input data, including statistical moments, probabilities, and coefficients of variation.

Source record↗