Search NASA⌕ Search

SEARCH · Search NASA

Results for “stream flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Lean Premixed Combustion Stabilized by Low Swirl a Promising Concept for Practical Applications

Since its inception, the low-swirl burner (LSB) has shown to be a useful laboratory apparatus for fundamental studies of premixed turbulent flames. The LSB operates under wide ranges of equivalence ratios, flow rates, and turbulence intensities. Its flame is lifted and detached from the burner and allows easy access for laser diagnostics. The flame brush is axisymmetric and propagates normal to the incident reactants. Therefore, the LSB is well suited for investigating detailed flame structures and empirical coefficients such as flame speed, turbulence transport, and flame generated turbulence. Due to its capability to stabilize ultra-lean premixed turbulent flames (phi approx. = 0.55), the LSB has generated interest from the gas appliance industry for use as an economical low-NO(x) burner. Lean premixed combustion emits low levels of NO(x), due primarily to the low flame temperature. Therefore, it is a very effective NO(x) prevention method without involving selective catalytic reduction (SCR), fuel-air staging, or flue gas recirculation (FGR). En the gas turbine industry, substantial research efforts have already been undertaken and engines with lean premixed combustors are already in use. For commercial and residential applications, premixed pulsed combustors and premixed ceramic matrix burners are commercially available. These lean premixed combustion technologies, however, tend to be elaborate but have relatively limited operational flexibility, and higher capital, operating and maintenance costs. Consequently, these industries are continuing the development of lean premixed combustion technologies as well as exploring new concepts. This paper summarizes the research effects we have undertaken in the past few years to demonstrate the feasibility of applying the low-swirl flame stabilization method for a wide range of heating and power generation systems. The principle of flame stabilization by low-swirl is counter to the conventional high-swirl methods that rely on a recirculation zone to anchor the flame. In LSBS, flow recirculation is not promoted to allow the premixed turbulent flames to propagate freely. A LSB with an air-jet swirler is essentially an open tube with the swirler at its mid section. The small air-jets generate swirling motion only in the annular region and leaving the central core of the flow undisturbed, When this flow exits the burner tube, the angular momentum generates radial mean pressure gradient to diverge the non-swirling reactants stream. Consequently, the mean flow velocity decreases linearly. Propagating against this decelerating flow, the flame self-sustains at the position where the local flow velocity equals the flame speed, S(sub f). The LSB operates with a swirl number, S, between 0.02 to 0.1. This is much lower than the minimum S of 0.6 required for the high-swirl burners. We found that the swirl number needed for flame stabilization varies only slightly with fuel type, flow velocity, turbulent conditions and burner dimensions (i.e. throat diameter and swirl injection angle).

Cheng, R. K.↗

Isotope separation methods and systems

Methods and systems for the separation of isotopes from an aqueous stream are described as can be utilized in one embodiment to remove and recover tritium from contaminated water. Methods include counter-current flow of an aqueous stream on either side of a separation membrane. The separation membrane includes an isotope selective layer (e.g., graphene) and an ion conductive supporting layer (e.g., Nafion®). An electronic driving force encourages passage of isotopes selectively across the membrane to enrich the flow in the isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Application of Biochemical and Physiological Indicators for Assessing Recovery of Fish Populations in a Disturbed Stream

Recovery dynamics in a previously disturbed streamwere investigated to determine the influence of a series of remedial actions on stream recovery and to evaluate the potential application of bioindicators as an environmental management tool. A suite of bioindicators, representing five different functional response groups, were measured annually for a sentinel fish species over a 15 year period during which a variety of remedial and pollution abatement actions were implemented. Trends in biochemical, physiological, condition, growth, bioenergetic, and nutritional responses demonstrated that the health status of a sentinel fish species in the disturbed stream approached that of fish in the reference stream by the end of the study. Two major remedial actions, dechlorination and water flow management, had large effects on stream recovery resulting in an improvement in the bioenergetic, disease, nutritional, and organ condition status of the sentinel fish species. A subset of bioindicators responded rather dramatically to temporal trends affecting all sites, but some indicators showed little response to disturbance or to restoration activities. In assessing recovery of aquatic systems, application of appropriate integrative structural indices along with a variety of sensitive functional bioindicators should be used to understand the mechanistic basis of stress and recovery and to reduce the risk of false positives. Understanding the mechanistic processes involved between stressors, stress responses of biota, and the recovery dynamics of aquatic systems reduces the uncertainty involved in environmental management and regulatory decisions resulting in an increased ability to predict the consequences of restoration and remedial actions for aquatic systems.

54 ENVIRONMENTAL SCIENCES↗

Mean horizontal wind profiles measured in the atmospheric boundary layer about a simulated block building

Instrumented wind towers are used to measure the three components of wind about a simulated block building. The mean horizontal wind profiles over the building are compared with wind profiles measured in the absence of the building and the wind speed deficit in the wake of the building is correlated. The turbulence intensity is of the order of 20% in the undisturbed flow whereas the free stream turbulence intensity of wind-tunnel studies is generally not more than 5%. The velocity profiles measured in the undisturbed flow zones support the representation of a neutrally stable atmospheric boundary layer with a logarithmic wind profile.

Frost, W.↗

Generating Emissions Inventory for Carbon Capture and Storage Analysis for Carbon-Intensive Industrial Sectors

Decarbonizing the industrial sector is critical to achieve carbon dioxide (CO2) emissions reductions goals of the Biden Administration. Currently available decarbonization options include electrification, fuel switching to zero carbon fuels like green hydrogen (H2) and carbon capture and storage (CCS). Application of post-combustion carbon capture (PCCC) technology in the power sector, as well as research at the U.S. Department of Energy's Fossil Energy and Carbon Management (FECM) Office has shown that its application in the industrial sector could have co-benefits in the form of emissions reductions of non-CO2 regulated pollutants. For example, solvent based PCCC systems require pre-conditioning of flue gas to remove sulfur and particulate matter (PM) upstream of the CO2 absorber. However, there is a lack of understanding about the type of non-CO2 pollutants which can be captured and the amount of reduction possible. PCCC application differs across industrial sectors as it depends on the availability of decarbonization options, characteristics of industrial processes and the amount and composition of pollutant flows. Certain facilities can also have multiple effluent flows with or without a CO2 stream. As such, understanding industrial processes and their effluent flows in detail is required to quantify the co-benefits opportunities presented by PCCC. Considering this requirement, the goal of this analysis is to develop a high-resolution inventory of effluent flows from facilities of 8 industrial sectors in the U.S. These industrial sectors - ethanol, ammonia, cement, steel, natural gas processing, hydrogen, petroleum refining and wood and pulp products - have carbon-intensive effluent flows, and thus are prime candidates for PCCC applications. In this study, we map the composition of pollutant flow from flue stacks across the identified facilities. Using data available in three Environmental Protection Agency (EPA) databases - the Green House Gas Reporting Program (GHGRP), the National Emissions Inventory (NEI) and the Toxic Release Inventory (TRI), we create a combined inventory which lists the type, amount, and concentration of pollutant flows. Using total weight of the pollutant flow back calculated from observed data for CO2 concentrations in flue gas for individual sectors, we calculate the concentration of each pollutant in the flue gas stream. Thus, the resultant emissions inventory includes the following details for each facility in the sector: facility-level and if possible, process-level pollutant flows, concentrations of pollutants in the flue gas, and geographical coordinates of the facilities. A detailed statistical analysis and summary allows us to search for erroneous data and remove them from the final inventory. The generation of the inventory is achieved using a python-based framework which can recreate this inventory for other industrial sectors as well as using newer releases of emission inventories from EPA. The statistical analysis performed on the inventory is also calibrated and automated to identify outliers efficiently.

air pollutants↗

An Improved Analytical Model of the Local Interstellar Magnetic Field: The Extension to Compressibility

A previously published analytical magnetohydrodynamic model for the local interstellar magnetic field in the vicinity of the heliopause (Röken et al. 2015) is extended from incompressible to compressible, yet predominantly subsonic flow, considering both isothermal and adiabatic equations of state. Exact expressions and suitable approximations for the density and the flow velocity are derived and discussed. In addition to the stationary induction equation, these expressions also satisfy the momentum balance equation along stream lines. The practical usefulness of the corresponding, still exact, analytical magnetic field solution is assessed by comparing it quantitatively to results from a fully self-consistent magnetohydrodynamic simulation of the interstellar magnetic field draping around the heliopause.

79 ASTRONOMY AND ASTROPHYSICS↗

Karst Groundwater Hydrologic Analyses Based on Aerial Thermography

On February 23, 1999, thermal imagery of Marshall Space Flight Center, Alabama was collected using an airborne thermal camera. Ground resolution was I in. Approximately 40 km 2 of thermal imagery in and around Marshall Space Flight Center (MSFC) was analyzed to determine the location of springs for groundwater monitoring. Subsequently, forty-five springs were located ranging in flow from a few ml/sec to approximately 280 liter/sec. Groundwater temperatures are usually near the mean annual surface air temperature. On thermography collected during the winter, springs show up as very warm spots. Many of the new springs were submerged in lakes, streams, or swamps; consequently, flow measurements were difficult. Without estimates of discharge, the impacts of contaminated discharge on surface streams would be difficult to evaluate. An approach to obtaining an estimate was developed using the Environmental Protection Agency (EPA) Cornell Mixing Zone Expert System (CORMIX). The thermography was queried to obtain a temperature profile down the center of the surface plume. The spring discharge was modeled with CORMIX, and the flow adjusted until the surface temperature profile was matched. The presence of volatile compounds in some of the new springs also allowed MSFC to unravel the natural system of solution cavities of the karst aquifer. Sampling results also showed that two springs on either side of a large creek had the same water source so that groundwater was able to pass beneath the creek.

Campbell, C. Warren↗

Mass flow sensor utilizing a resistance bridge

A mass flow sensor to be mounted within a duct and measures the mass flow of a fluid stream moving through the duct. The sensor is an elongated thin quartz substrate having a plurality of platinum strips extending in a parallel relationship on the strip, with certain of the strips being resistors connected to an excitation voltage. The resistors form the legs of a Wheatstone bridge. The resistors are spaced a sufficient distance inwardly from the leading and trailing edges of the substrate to lie within the velocity recovery region so that the measured flow is the same as the actual upstream flow. The resistor strips extend at least half-way through the fluid stream to include a substantial part of the velocity profile of the stream. Certain of the resistors detect a change in temperature as the fluid stream moves across the substrate to provide an output signal from the Wheatstone bridge which is representative of the fluid flow. A heater is located in the midst of the resistor array to heat the air as it passes over the array.

Fralick, Gustave C.↗

Review: The distribution, flow, and quality of Grand Canyon Springs, Arizona (USA)

An understanding of the hydrogeology of Grand Canyon National Park (GRCA) in northern Arizona, USA, is critical for future resource protection. The ~750 springs in GRCA provide both perennial and seasonal flow to numerous desert streams, drinking water to wildlife and visitors in an otherwise arid environment, and habitat for rare, endemic and threatened species. Spring behavior and flow patterns represent local and regional patterns in aquifer recharge, reflect the geologic structure and stratigraphy, and are indicators of the overall biotic health of the canyon. These springs, however, are subject to pressures from water supply development, changes in recharge from forest fires and other land management activities, and potential contamination. Roaring Springs is the sole water supply for residents and visitors (>6 million/year), and all springs support valuable riparian habitats with very high species diversity. Most springs flow from the karstic Redwall-Muav aquifer and show seasonal patterns in flow and water chemistry indicative of variable aquifer porosities, including conduit flow. They have Ca/Mg-HCO{sub 3} dominated chemistry and trace elements consistent with nearby deep wells drilled into the Redwall-Muav aquifer. Tracer techniques and water-age dating indicate a wide range of residence times for many springs, supporting the concept of multiple porosities. A perched aquifer produces small springs which issue from the contacts between sandstone and shale units, with variable groundwater residence times. Stable isotope data suggest both an elevational and seasonal difference in recharge between North and South Rim springs. This review highlights the complex nature of the groundwater system.

54 ENVIRONMENTAL SCIENCES↗

Flow and temperature fields following injection of a jet normal to a cross stream

The interaction of a jet entering into a freestream normal to the main flow direction has been studied with particular attention directed to visualization of the large-scale flow interactions and to measurement of the film-cooling performance. Large eddies are apparent downstream of the entering jet even at moderate blowing rate (defined as the ratio of the mass velocity of the jet to the mass velocity of the freestream). At higher blowing rate, there is only intermittent contact between the mass from the jet and the downstream wall. The film cooling downstream from a single normal jet yields a lower centerline effectiveness compared to an inclined jet through a greater lateral spreading. The greater spreading provides a more uniform effectiveness across the span of the downstream wall, in particular at large blowing rate.

Goldstein, R. J.↗

Testing Installed Propulsion For Shielded Exhaust Configurations

Jet-surface interaction (JSI) can be a significant factor in the exhaust noise of installed propulsion. Tests to further understanding and prediction of the acoustic impacts of JSI have been described. While there were many objectives for the NASA JSI1044 test, the overall objective was to prepare for a 2016 test validating the design of a low-noise, low-boom supersonic commercial airliner. In this paper we explore design requirements for a partial aircraft model to be used in subscale acoustic testing, especially focusing on the amount of shielding surface that must be provided to simulate the acoustic environment between propulsion exhaust system and observer. We document the dual-stream jets, both nozzle and flow conditions, which were tested to extend JSI acoustic modeling from simple single-stream jets to realistic dual-stream exhaust nozzles. Examples of observations found as surface geometry and flow conditions were varied were provided. And we have presented initial measurements of the installation impacts of integrating the propulsion on the airframe for a supersonic airliner with realistic airframe geometries and nozzles.

engine airframe integration↗

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Shifting Trade-offs: Finding the Sustainable Nexus of Hydropower and Environmental Flows in the San Joaquin River Watershed, California

Environmental flow management in watersheds with multi-objective reservoirs is often presented as an additional constraint to an already strained and over-allocated stream system. Nevertheless, environmental flow legislation and regulatory policies are increasingly being developed and implemented globally. In California, USA, recent legislative and regulatory policies place environmental flows at the forefront of the state’s water management objectives; however, the increased reliance on hydropower to support climate change mitigation goals may complicate efforts on both issues. This study modelled alternative environmental flow strategies in the major tributaries to the San Joaquin River in California. Strategies included detailed water management rules for hydropower production, flood control, and water deliveries, and three methodological approaches to environmental flow releases: minimum instream flows (“baseline”) year-round, 40% of full natural flow (FNF) during the spring runoff season and minimum releases the remainder of the year, and functional flows year-round. Results show that environmental flow strategies affect downstream flow releases in each of the San Joaquin’s four sub-basins differently depending on infrastructure capacity, water management objectives, and hydrologic year types. While hydropower production was comparable or declined in the Stanislaus, Tuolumne, and Merced basins, functional flow and 40% FNF strategies increased hydropower production in the Upper San Joaquin basin by 11%. Uncontrolled spill of high flow events decreased when high flow releases were based on hydrologic cues rather than exclusively on flood storage capacity. Water deliveries were reduced in all years regardless of environmental flow strategy. The 40% FNF and functional flow strategies both increased water released to the river relative to baseline, but in different ways. The functional flow strategy allocated water in a holistic approach that enhanced ecological functions in all years, but particularly in moderate and wet years. In contrast, the 40% FNF strategy provided increased flows relative to baseline and some ecological benefit in dry years, but less ecological benefit in other years. This study shows that alternative environmental flow strategies will have different and important trade-offs for integrated water management, and may mutually benefit seemingly conflicting objectives.

13 HYDRO ENERGY↗

Understanding Columbia's Reentry Problems

Soon after the Space Shuttle Columbia accident occurred last year, a group of CFD analysts from NASA centers and private industry was organized to help determine the cause of the accident. This group was under the direction of the Applied Aeroscience and CFD Branch of the Aeroscience and Flight Mechanics Division at the Johnson Space Center. For external flow simulations, noncommercial CFD codes that specialize in hypersonic or high Mach number flows were used. These tools were used to determine heating rates, pressures, and temperatures for a large number of vehicle damage scenarios. Lockheed Martin Space Operations was called upon to provide CFD support in the area of internal flows within the shuttle wing cavity, and or these simulations, FLUENT 6.1 was chosen. Two large-scale, simplified models were run to understand the flow patterns once a breach of the internal wing cavity was initiated. The results were primarily used to visualize flow patterns within the wing cavity. The first CFD model included the entire left wing without the wheel. well cavity. The purpose of the first model, which did not include the reinforced carbon-carbon (RCC) cavity along the wing leading edge, was to visualize the flow field within the wing cavity immediately after the leading edge spar breach, This model assumed that the flow coming into the wing cavity was nom1 to the spar. It included all o f the primary vents that allow for flow between the main cavities of the wing. A six-inch diameter hole was modeled in the spar at the approximate location where the spar breach was judged to have occurred, which was between RCC panels 8 and 9. The results of the modeling showed that at this location, the high temperature, high velocity gas stream entering the wing cavity impinged on the outboard wheel well cavity. Instrumentation in the Shuttle wheel well cavity registered abnormal temperatures during reentry, so the FLUENT results helped support the conclusion of the accident investigation team that the spar breach was in the RCC panel 8-9 area, and that the initial spar breach was likely entering the wing cavity normal to the spar. This model also showed that the flow entering the wing cavity tended to swirl within the cavity just outboard of the wheel well, and did not initially penetrate further into the rear cavities of the wing. The second CFD model was a 2-D simulation of the left wing cavity and the RCC cavity. It was used to visualize the flow through the RCC breach, through the wing spar breach, and into the wing cavity directly outboard of the wheel well. The purpose of this model was to verify whether or not it was possible for the flow to come into the wing cavity normal to the leading edge spar. The results from this 2-D model showed that the internal structure behind the RCC panels probably deflected the flow entering the RCC cavity so that it impinged normal to the spar. As in the 3-D model, this deflected flow stream was found to impinge on the wheel well outer wall. This model again supported the conclusions regarding the location of the spar breach and how the flow behaved inside the wing cavity.

Paul, Thomas H.↗

Understanding Columbia's Reentry Problems

Soon after the Space Shuttle Columbia accident occurred last year, a group of CFD analysts from NASA centers and private industry was organized to help determine the cause of the accident. This group was under the direction of the Applied Aeroscience and CFD Branch of the Aeroscience and Flight Mechanics Division at the Johnson Space Center. For external flow simulations, noncommercia2 CFD codes that specialize in hypersonic or high Mach number flows were used. These tools were used to determine heating rates, pressures, and temperatures for a large number of vehicle damage scenarios. Lockheed Martin Space Operations was called upon to provide CFD support in the area of internal flows within the shuttle wing cavity, and for these simulations, FLUENT 6.1 was chosen. Two large-scale, simplified models were m to understand the flow patterns once a breach of the internal wing cavity was initiated. The results were primarily used to visualize flow patterns within the wing cavity. The first CFD model included the entire lee wing without the wheel well cavity. The purpose of the first model, which did not include the reinforced carbon-carbon (RCC) cavity along the wing leading edge, was to visualize the flow field within the wing cavity immediately after the leading edge spar breach, This model assumed that the flow coming into the wing cavity was normal to the spar. It included all of the primary vents that allow for flow between the main cavities of the wing. A six-inch diameter hole was modeled in the spar at the approximate location where the spar breach was judged to have occurred, which was between RCC panels 8 and 9. The results of the modeling showed that at this location, the high temperature, high velocity gas stream entering the wing cavity impinged on the outboard wheel well cavity. Instrumentation in the Shuttle wheel well cavity registered abnormal temperatures during reentry, so the FLUENT results helped support the conclusion of the accident investigation team that the spar breach was in the RCC panel 8-9 area, and that the initial spar breach was likely entering the wing cavity normal to the spar. This model also showed that the flow entering the wing cavity tended to swirl within the cavity just outboard of the wheel well, and did not initially penetrate further into the rear cavities of the wing. The second CFD model was a 2-D simulation of the left wing cavity and the RCC cavity. It was used to visualize the flow through the RCC breach, through the wing spar breach, and into the wing cavity directly outboard of the wheel well. The purpose of this model was to verify whether or not it was possible for the flow to come into the wing cavity normal to the leading edge spar. The results from this 2-D model showed that the internal structure behind the RCC panels probably deflected the flow entering the RCC cavity so that it impinged normal to the spar. As in the 3-D model, this deflected flow stream was Found to impinge on the wheel well outer wall. This model again supported the conclusions regarding the location of the spar breach and how the flow behaved inside the wing cavity.

Paul, Thomas↗

(abstract) Three Dimensional Ice-Flow Velocity Estimation Using Satellite Radar Interferometry

An understanding of the flow dynamics of an ice sheet's outlet glaciers and ice streams requires knowledge of their flow velocity and strain rates (i.e., velocity gradients). Prior to the recent advent of satellite radar interferometry, it was not possible to measure detailed ice-flow velocity over the vast featureless areas that comprise most of the ice sheets. Since the launch of ERS-1, the use of satellite radar interferometry data for making densly sampled ice-flow velocity measurements has been firmly established by several studies. We have combined data from nonparallel orbits with surface slope information to make vector ice-flow measurements for the Ryder Glacier, Greenland. Our results for the Ryder are promising and indicate that repeat-pass interferometric data can be used to make vector measurements of ice velocity.

ice sheets radar interferometry glaciers flow dyna↗

Experimental Aeroheating Study of Mid-L/D Entry Vehicle Geometries: NASA LaRC 20-Inch Mach 6 Air Tunnel Test 6966

Aeroheating data on mid lift-to-drag ratio entry vehicle configurations has been obtained through hypersonic wind tunnel testing. Vehicles of this class have been proposed for high-mass Mars missions, such as sample return and crewed exploration, for which the conventional sphere-cone entry vehicle geometries of previous Mars missions are insufficient. Several configurations were investigated, including elliptically-blunted cylinders with both circular and elliptical cross sections, biconic geometries based on launch vehicle dual-use shrouds, and parametrically-optimized analytic geometries. Testing was conducted at Mach 6 over a range of Reynolds numbers sufficient to generate laminar, transitional, and turbulent flow. Global aeroheating data were obtained using phosphor thermography. Both stream-wise and cross-flow transition occured on different configurations. Comparisons were made with laminar and turbulent computational predictions generated with an algebraic turbulence model. Predictions were generally in good agreement in regions of laminar or fully-turbulent flow; however for transitional cases, the lack of a transition onset prediction capability produced less accurate comparisons. The data obtained in this study are intended to be used for prelimary mission design studies and the development and validation of computational methods.

Hollis, Brian R.↗

Seasonal and flow-driven dynamics of particulate and dissolved mercury and methylmercury in a stream impacted by an industrial mercury source

Abstract Sediments and floodplain soils in the East Fork Poplar Creek watershed (Oak Ridge, TN, USA) are contaminated with high levels of mercury (Hg) from an industrial source at the headwaters. Although baseflow conditions have been monitored, concentrations of Hg and methylmercury (MeHg) during high-flow storm events, when the stream is more hydrologically connected to the floodplain, have yet to be assessed. The present study evaluated baseflow and event-driven Hg and MeHg dynamics in East Fork Poplar Creek, 5 km upstream of the confluence with Poplar Creek, to determine the importance of hydrology to in-stream concentrations and downstream loads and to ascertain whether the dynamics are comparable to those of systems without an industrial Hg source. Particulate Hg and MeHg were positively correlated with discharge (r2 = 0.64 and 0.58, respectively) and total suspended sediment (r2 = 0.97 and 0.89, respectively), and dissolved Hg also increased with increasing flow (r2 = 0.18) and was associated with increases in dissolved organic carbon (r2 = 0.65), similar to the dynamics observed in uncontaminated systems. Dissolved MeHg decreased with increases in discharge (r2 = 0.23) and was not related to dissolved organic carbon concentrations (p = 0.56), dynamics comparable to relatively uncontaminated watersheds with a small percentage of wetlands (<10%). Although stormflows exert a dominant control on particulate Hg, particulate MeHg, and dissolved Hg concentrations and loads, baseflows were associated with the highest dissolved MeHg concentration (0.38 ng/L) and represented the majority of the annual dissolved MeHg load. Environ Toxicol Chem 2016;35:1386–1400. Published 2015 Wiley Periodicals, Inc. on behalf of SETAC. This article is a US Government work, and as such, is in the public domain in the United States of America.

54 ENVIRONMENTAL SCIENCES↗