Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

High Resolution X-Ray Microangiography of 4T1 Tumor in Mouse Using Synchrotron Radiation

Angiogenesis is very important in tumor growth and metastasis. But in clinic, only vessels lager than 200 {mu}m in diameter, can be observed using conventional medical imaging. Synchrotron radiation (SR) phase contrast imaging, whose spatial resolution can reach as high as 1 {mu}m, has great advantages in imaging soft tissue structures, such as blood vessels and tumor tissues. In this paper, the morphology of newly formed micro-vessels in the mouse 4T1 tumor samples was firstly studied with contrast agent. Then, the angiogenesis in nude mice tumor window model was observed without contrast agent using the SR phase contrast imaging at the beamline for X-ray imaging and biomedical applications, Shanghai Synchrotron Radiation Facility (SSRF). The images of tumors showed dense, irregular and tortuous tumor micro-vessels with the smallest size of 20-30 {mu}m in diameter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inversion of coherent surface scattering images via deep learning network

Coherent surface scattering imaging is a powerful tool for imaging a surface/interface of a thin nanostructure deposited on an opaque substrate. A mathematical conversion of an object image from a scattering pattern is essential for coherent surface scattering imaging to visualize structures of specimens. It has been achieved by using phase retrieval algorithms requiring oversampling in scattering patterns and employing alternating projection approaches. It is a computationally challenging and time-consuming process. In this paper, we demonstrate CSSI-NN, which is a deep learning neural network model to predict images of objects from scattering intensities in coherent surface scattering imaging. This model allowing for the instant outcome from scattering patterns would be tremendously beneficial not only for effective experiments but also for data analysis of phase retrieval.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-F-CAMPUS-T-05: Replacement Computational Phantoms to Estimate Dose in Out-Of-Field Organs and Tissues

Purpose: To estimate the absorbed dose in organs and tissues at risk for radiogenic cancer for children receiving photon radiotherapy for localized brain tumors (LBTs) by supplementing their missing body anatomies with those of replacement computational phantoms. Applied beyond the extent of the RT Images collected by computed tomography simulation, these phantoms included RT Image and RT Structure Set objects that encompassed sufficient extents and contours for dosimetric calculations. Method: Nine children, aged 2 to 14 years, who received three-dimensional conformal radiotherapy for low-grade LBTs, were randomly selected for this study under Institutional-Review-Board protocol. Because the extents of their RT Images were cranial only, they were matched for size and sex with patients from a previous study with larger extents and for whom contours of organs at risk for radiogenic cancer had already been delineated. Rigid fusion was performed between the patients’ data and those of the replacement computational phantoms using commercial software. In-field dose was calculated with a clinically-commissioned treatment planning system, and out-of-field dose was estimated with an analytical model. Results: Averaged over all nine children and normalized for a therapeutic dose of 54 Gy prescribed to the PTV, where the PTV is the GTV, the highest mean organ doses were 3.27, 2.41, 1.07, 1.02, 0.24, and 0.24 Gy in the non-tumor remainder, red bone marrow, thyroid, skin, breasts, and lungs, respectively. The mean organ doses ranged by a factor of 3 between the smallest and largest children. Conclusion: For children receiving photon radiotherapy for LBTs, we found their doses in organs at risk for second cancer to be non-negligible, especially in the non-tumor remainder, red bone marrow, thyroid, skin, breasts, and lungs. This study demonstrated the feasibility for patient dosimetry studies to augment missing patient anatomy by applying size- and sex-matched replacement computational phantoms with pre-contoured organs. Funding is in part by the Fogarty International Center award K01TW008409, and the Portland Chapter of the Achievement Rewards for College Scientists. The content is solely the responsibility of the authors, and does not necessarily represent the official views of the sponsors. The authors declare no conflict of interest.

60 APPLIED LIFE SCIENCES↗

Nanoscale x-ray and electron tomography

We present that three-dimensional (3D) tomographic imaging of the structural, chemical, and physical properties of a material provides key knowledge that links the structure of a material to both its processing and structure that is central to studies across a broad spectrum of materials. For many decades, tomography using x-rays or electrons has proven to be an essential 3D characterization tool. In recent years, advances in technology have significantly pushed the envelope of these techniques in many respects, enabling new imaging capabilities at the nanometer and atomic scale. This article highlights several such developments in nanoscale x-ray and electron tomography. The five articles that appear in this issue of MRS Bulletin discuss research frontiers that include multimodal x-ray tomography at the nanoscale, x-ray spectroscopic tomography, dark-field x-ray microscopy, electron nanotomography for functional nanomaterials, and atomistic imaging by electron tomography. Lastly, these articles give a holistic view of the status of these techniques and promising future directions, as well highlighting their applications for scientific problems.

36 MATERIALS SCIENCE↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

High-resolution analogue of time-domain phonon spectroscopy in the transmission electron microscope

Femtosecond photoexcitation of semiconducting materials leads to the generation of coherent acoustic phonons (CAPs), the behaviours of which are linked to intrinsic and engineered electronic, optical and structural properties. While often studied with pump-probe spectroscopic techniques, the influence of nanoscale structure and morphology on CAP dynamics can be challenging to resolve with these all-optical methods. Here, we used ultrafast electron microscopy (UEM) to resolve variations in CAP dynamics caused by differences in the degree of crystallinity in as-prepared and annealed GaAs lamellae. Following in situ femtosecond photoexcitation, we directly imaged the generation and propagation dynamics of hypersonic CAPs in a mostly amorphous and, following an in situ photothermal anneal, a mostly crystalline lamella. Subtle differences in both the initial hypersonic velocities and the asymptotic relaxation behaviours were resolved via construction of space-time contour plots from phonon wavefronts. Comparison to bulk sound velocities in crystalline and amorphous GaAs reveals the influence of the mixed amorphous-crystalline morphology on CAP dispersion behaviours. Further, an increase in the asymptotic velocity following annealing establishes the sensitivity of quantitative UEM imaging to both structural and compositional variations through differences in bonding and elasticity. Lastly, implications of extending the methods and results reported here to elucidating correlated electronic, optical and structural behaviours in semiconducting materials are discussed.

42 ENGINEERING↗

Measuring the Burgers vector of dislocations with dark-field X-ray microscopy

The subsurface dynamics of dislocations are essential to many properties of bulk crystalline materials. However, it is challenging to characterize a bulk crystal by conventional transmission electron microscopy (TEM) due to the limited penetration depth of electrons. A novel X-ray imaging technique – dark-field X-ray microscopy (DFXM) – was developed to image hierarchical dislocation structures in bulk crystals. While today's DFXM can effectively map the line structures of dislocations, it is still challenging to quantify the Burgers vectors, the key characterization governing the dislocation behaviors. Here, we extend the 'invisibility criterion' formalism from the TEM theory to the geometrical-optics model of DFXM and demonstrate the consistency between DFXM and dark-field TEM using multi-diffraction-peak imaging for a single edge dislocation. Due to the practical difficulty of multi-peak DFXM experiments, we further study how the Burgers vector effect is encoded for a single-peak DFXM experiment. Using the geometrical-optics DFXM simulation, we explore the asymmetry of rocking tilt scans at different rolling tilts and develop a new method to characterize the Burgers vector. The conclusions of this study advance our understanding of the use of DFXM in characterizing individual dislocations, enabling the connection from bulk DFXM imaging to dislocation mechanics.

36 MATERIALS SCIENCE↗

KINEMATICS AND FINE STRUCTURE OF AN UNWINDING POLAR JET OBSERVED BY THE SOLAR DYNAMIC OBSERVATORY/ATMOSPHERIC IMAGING ASSEMBLY

We present an observational study of the kinematics and fine structure of an unwinding polar jet, with high temporal and spatial observations taken by the Atmospheric Imaging Assembly on board the Solar Dynamic Observatory and the Solar Magnetic Activity Research Telescope. During the rising period, the shape of the jet resembled a cylinder with helical structures on the surface, while the mass of the jet was mainly distributed on the cylinder's shell. In the radial direction, the jet expanded successively at its western side and underwent three distinct phases: the gradually expanding phase, the fast expanding phase, and the steady phase. Each phase lasted for about 12 minutes. The angular speed of the unwinding motion of the jet and the twist transferred into the outer corona during the eruption are estimated to be 11.1 x 10{sup -3} rad s{sup -1} (period = 564 s) and 1.17-2.55 turns (or 2.34-5.1{pi}), respectively. On the other hand, by calculating the azimuthal component of the magnetic field in the jet and comparing the free energy stored in the non-potential magnetic field with the jet's total energy, we find that the non-potential magnetic field in the jet is enough to supply the energy for the ejection. These new observational results strongly support the scenario that the jets are driven by the magnetic twist, which is stored in the twisted closed field of a small bipole, and released through magnetic reconnection between the bipole and its ambient open field.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of different fractal dimension measuring algorithms for RE-TM M-O films

Noise in magneto-optical recording devices is discussed. In general, it appears that either the divider technique or amplitude spectrum technique may be used interchangeably to measure the fractal dimension (D) in the domain wall structure of ideal images. However, some caveats must be observed for best results. The divider technique is attractive for its simplicity and relatively modest computation requirements. However, it is sensitive to noise, in that noise pixels that touch the domain boundary are interpreted as being part of the boundary, skewing the measurement. Also, it is not useful in measuring nucleation-dominated films or domains that have significant amounts of structure within the interior of the domain wall. The amplitude spectrum method is more complex, and less intuitive than the divider method, and somewhat more expensive to implement computationally. However, since the camera noise tends to be white, the noise can be avoided in the measurement of D by avoiding that portion of the curve that is flat (due to the white noise) when the least squares line is fit to the plot. Also, many image processing software packages include a Fast Fourier Transformation (FFT) facility, while the user will most likely have to write his own edge extraction routine for the divider method. The amplitude spectrum method is a true two dimensional technique that probes the interior of the domain wall, and in fact, can measure arbitrary clusters of domains. It can also be used to measure grey-level images, further reducing processing steps needed to threshold the image.

Bernacki, Bruce E.↗

Characterization of microrod arrays by image analysis

The uniformity of the properties of array elements was evaluated by statistical analysis of microscopic images of array structures, assuming that the brightness of the array elements correlates quantitatively or qualitatively with a microscopically probed quantity. Derivatives and autocorrelation functions of cumulative frequency distributions of the object brightnesses were used to quantify variations in object properties throughout arrays. Thus, different specimens, the same specimen at different stages of its fabrication or use, and different imaging conditions can be compared systematically. As an example, we analyzed scanning electron micrographs of microrod arrays and calculated the percentage of broken microrods.

36 MATERIALS SCIENCE↗

Two-color volumetric laser-induced fluorescence for 3D OH and temperature fields in turbulent reacting flows

two-color, volumetric laser-induced fluorescence (TC-VLIF) was demonstrated for three-dimensional, tomographic imaging of the structural properties of the OH radical and temperature field in a turbulent hydrogen-air flame. Two narrow-band laser sources were tuned to the Q i (5) and Q i (14) transitions of the (1,0) band in the A 2 E<—X 2 II system and illuminated a volumetric region of the flame. Images from eight unique perspectives collected simultaneously from each of the two transitions were used to reconstruct overlapping 011 fields with different Boltzmann fractions and map the 3D temperature distribution with nanosecond precision. Key strategies for minimizing sources of error, such as detector sensitivity and spatial overlap of the two fields, are discussed.

42 ENGINEERING↗

A Pilot Study on Collective Effects of 22q13.31 Deletions on Gray Matter Concentration in Schizophrenia

The association of copy number variation (CNV) with schizophrenia has been reported with evidence of increased frequency of both rare and large CNVs. Yet, little is known about the impact of CNVs in brain structure. In this pilot study, we explored collective effects of all CNVs in each cytogenetic band on the risk of schizophrenia and gray matter variation measured in structural magnetic resonance imaging. With 324 participants’ CNV profiles (151 schizophrenia patients and 173 healthy controls), we first extracted specific CNV features that differ between patients and controls using a two sample t-test, and then tested their associations with gray matter concentration using a linear regression model in a subset of 301 participants. Our data first provided evidence of population structure in CNV features where elevated rare CNV burden in schizophrenia patients was confounded by the levels associated with African American subjects. We considered this ethnic group difference in the following cytoband analyses. Deletions in one cytoband 22q13.31 were observed significantly (p < 0.05) more in patients than controls from all samples after controlling ethnicity, and the deletion load was also significantly (p = 1.44610 -4 ) associated with reduced gray matter concentration of a brain network mainly comprised of the cingulate gyrus and insula. Since 80% deletion carriers were patients, patients with deletions also showed reduced gray matter concentration compared with patients without deletions (p = 3.36610 -4 ). Our findings indicate that regional CNVs at 22q13.31, no matter the size, may influence the risk of schizophrenia with a remarkably increased mutation rate and with reduced gray matter concentration in the peri-limbic cortex. This proof-of-concept study suggests that the CNVs occurring at some ‘hotspots’ may in fact cause biological downstream effects and larger studies are important for confirming our initial results.

60 APPLIED LIFE SCIENCES↗

Characterizing filamentary magnetic structures in counter-streaming plasmas by Fourier analysis of proton images

Proton imaging is a powerful tool for probing electromagnetic fields in a plasma, providing a path-integrated map of the field topology. However, in cases where the field structure is highly inhomogeneous, inferring spatial properties of the underlying field from proton images can be difficult. This problem is exemplified by recent experiments, which used proton imaging to probe the filamentary magnetic field structures produced by the Weibel instability in collisionless counterstreaming plasmas. In this paper, we perform analytical and numerical analyses of proton images of systems containing many magnetic filaments. We find that, in general, the features observed on proton images do not directly correspond to the spacing between magnetic filaments (the magnetic wavelength) as has previously been assumed and that they instead correspond to the filament size. Furthermore, we demonstrate this result by Fourier analysis of synthetic proton images for many randomized configurations of magnetic filaments. Our results help guide the interpretation of experimental proton images of filamentary magnetic structures in plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beyond the Global Brain Differences: Intraindividual Variability Differences in 1q21.1 Distal and 15q11.2 BP1-BP2 Deletion Carriers

Carriers of the 1q21.1 distal and 15q11.2 BP1-BP2 copy number variants exhibit regional and global brain differences compared with noncarriers. However, interpreting regional differences is challenging if a global difference drives the regional brain differences. Intraindividual variability measures can be used to test for regional differences beyond global differences in brain structure. Magnetic resonance imaging data were used to obtain regional brain values for 1q21.1 distal deletion (n = 30) and duplication (n = 27) and 15q11.2 BP1-BP2 deletion (n = 170) and duplication (n = 243) carriers and matched noncarriers (n = 2350). Regional intra-deviation scores, i.e., the standardized difference between an individual’s regional difference and global difference, were used to test for regional differences that diverge from the global difference. For the 1q21.1 distal deletion carriers, cortical surface area for regions in the medial visual cortex, posterior cingulate, and temporal pole differed less and regions in the prefrontal and superior temporal cortex differed more than the global difference in cortical surface area. For the 15q11.2 BP1-BP2 deletion carriers, cortical thickness in regions in the medial visual cortex, auditory cortex, and temporal pole differed less and the prefrontal and somatosensory cortex differed more than the global difference in cortical thickness. We find evidence for regional effects beyond differences in global brain measures in 1q21.1 distal and 15q11.2 BP1-BP2 copy number variants. The results provide new insight into brain profiling of the 1q21.1 distal and 15q11.2 BP1-BP2 copy number variants, with the potential to increase understanding of the mechanisms involved in altered neurodevelopment.

15q11.2 BP1-BP2↗

Laboratory-size three-dimensional water-window x-ray microscope with Wolter type I mirror optics

We constructed a laboratory-size three-dimensional water-window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques. It consists of an electron-impact x-ray source emitting oxygen Kα x-rays, Wolter type I grazing incidence mirror optics, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit better than 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm-scale three-dimensional fine structures were resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative correlational study of microbubble-enhanced ultrasound imaging and magnetic resonance imaging of glioma and early response to radiotherapy in a rat model

Purpose: Radiotherapy remains a major treatment method for malignant tumors. Magnetic resonance imaging (MRI) is the standard modality for assessing glioma treatment response in the clinic. Compared to MRI, ultrasound imaging is low-cost and portable and can be used during intraoperative procedures. The purpose of this study was to quantitatively compare contrast-enhanced ultrasound (CEUS) imaging and MRI of irradiated gliomas in rats and to determine which quantitative ultrasound imaging parameters can be used for the assessment of early response to radiation in glioma. Methods: Thirteen nude rats with U87 glioma were used. A small thinned skull window preparation was performed to facilitate ultrasound imaging and mimic intraoperative procedures. Both CEUS and MRI with structural, functional, and molecular imaging parameters were performed at preradiation and at 1 day and 4 days postradiation. Statistical analysis was performed to determine the correlations between MRI and CEUS parameters and the changes between pre- and postradiation imaging. Results: Area under the curve (AUC) in CEUS showed significant difference between preradiation and 4 days postradiation, along with four MRI parameters, T{sub 2}, apparent diffusion coefficient, cerebral blood flow, and amide proton transfer-weighted (APTw) (all p < 0.05). The APTw signal was correlated with three CEUS parameters, rise time (r = − 0.527, p < 0.05), time to peak (r = − 0.501, p < 0.05), and perfusion index (r = 458, p < 0.05). Cerebral blood flow was correlated with rise time (r = − 0.589, p < 0.01) and time to peak (r = − 0.543, p < 0.05). Conclusions: MRI can be used for the assessment of radiotherapy treatment response and CEUS with AUC as a new technique and can also be one of the assessment methods for early response to radiation in glioma.

60 APPLIED LIFE SCIENCES↗

Systems for ultrasonic scanning, analysis and imagery

A variety of ultrasonic scanning and imagery techniques are used to investigate various aspects of materials and microstructures. Two ultrasonic scanning systems are in use by the Lewis Research Center's Structural Integrity Branch: an immersion scanner and a contact scanning system. The basic principles of scanning are reviewed, examples of images are presented, and structural features suggested by these images are discussed. Both of these systems are custom designed; their capabilities, advantages, and disadvantages are highlighted.

Stang, David B.↗