Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Test Pattern for IC's

Random-fault densities measured in array of standard structures. Test pattern is array of standard circuit elements built into circuit chip along with, or in lieu of, integrated circuit objective process. Measurements on ray made and interpreted so fabrication process can be corrected as necessary.

Griswold, T. W.↗

Experiment design for the neutron irradiation of $\mathrm{PM-HIP}$ alloys for nuclear reactors

Here, this article describes the design of an Advanced Test Reactor (ATR) drop-in neutron irradiation experiment aiming to directly compare the performance of nuclear structural alloys fabricated by powder metallurgy with hot isostatic pressing (PM-HIP) against conventional casting or forging. There is growing interest in PM-HIP alloys for nuclear applications because of their microstructural uniformity, superior mechanical properties, and reduced dependence on welding and machining, compared to cast/forged alloys. Nuclear code-qualification of PM-HIP alloys requires neutron irradiation testing to demonstrate performance under relevant conditions. In this experiment, six nuclear structural alloys were irradiated: Ni-based alloys 625 and 690, Grade 91 ferritic steel, SA508 pressure vessel steel, and 304L and 316L austenitic stainless steels. The experiment is assembled into seven capsules in four test trains and irradiated in three ATR inboard A positions. Both the PM-HIP and cast/forged versions of each alloy were irradiated under nearly identical conditions for comparative purposes, to target doses of 1 ± 0.2 and 3 ± 0.2 dpa at temperatures of 300 ± 50 °C and 400 ± 50 °C. A thorough description of the experiment design and thermal, structural and neutronic analyses performed to ensure the targeted irradiation conditions are met is provided. Specimens were configured as small disks, compact tension specimens and tensile bars to facilitate post-irradiation examination (PIE) that will include mechanical testing, microstructure characterization, and fracture toughness testing. Given the considerations for ASTM standardized mechanical testing, comparative fluence and temperature across specimen pairs, and comprehensive PIE planning herein, this work serves as a template for future nuclear materials qualification experiment designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Navy Flight Testing Environmental Data Transfer Format Standard

This document outlines key elements of a data format standard for transferring Navy environmental flight test data between members of the Collaborative Environments Characterization Working Group (CECWG). The plan applies to measured data as well as analyzed or processed data. This plan is intended to foster a more productive collaboration between CECWG members by providing a common interface format such that each agency only has to receive and transmit data in one common format. Ideally, each agency is thus only responsible for translating formats between the native format of each agency’s respective database of flight measurements and this common data transfer format.

97 MATHEMATICS AND COMPUTING↗

Improved impact-resistant boron/aluminum composites for use as turbine engine fan blades

Thin-sheet Charpy and Izod impact tests and standard full-size Charpy impact tests were conducted on unidirectional and angleply composites containing 4, 5.6 and 8 mil boron in 1100, 2024, 5052 and 6061 Al matrices. Impact failure modes of B/Al are proposed to describe the mechanisms involved and to provide insight for maximizing impact resistance. The impact strength of B/Al was significantly increased by proper selection of materials and processing. The use of more ductile matrices and larger diameter boron fibers gave the highest impact strengths by allowing matrix shear deformation and multiple fiber breakage. Pendulum impact test results of improved B/Al were higher than notched titanium and indicate sufficient foreign object damage protection to warrant consideration of B/Al for application to fan blades in aircraft gas turbine engines.

Mcdanels, D. L.↗

Effect of fiber diameter and matrix alloys on impact-resistant boron/aluminum composites

Efforts to improve the impact resistance of B/Al are reviewed and analyzed. Nonstandard thin-sheet charpy and Izod impact tests and standard full-size Charpy impact tests were conducted on composites containing unidirectional 0.10mm, 0.14mm, and 0.20mm diameter boron fibers in 1100, 2024, 5052, and 6061 Al matrices. Impact failure modes of B/Al are proposed in an attempt to describe the mechanisms involved and to provide insight for maximizing impact resistance. The impact strength of B/Al was significantly increased by proper selection of materials and processing. The use of a ductile matrix and large diameter boron fibers gave the highest impact strengths. This combination resulted in improved energy absorption through matrix shear deformation and multiple fiber breakage.

Mcdanels, D. L.↗

Flight Tests of an Airplane Showing Dependence of the Maximum Lift Coefficient on the Test Conditions

Data are presented to show the extent to which the maximum lift coefficient and consequently the minimum speed of an airplane, determined by flight tests, may vary with test conditions. The data show that cl-max may vary as much as 14 percent, depending on the altitude and wing loading at which the tests were made, the position or motion of the propeller, and the rate at which the angle of attack is changing when the maximum lift coefficient is obtained. The variation of the maximum lift coefficient with these factors, which are under the control of the test engineer, shows the need of standardizing the test procedure. A further variation is shown with wing conditions as affected by weathering and vibration, factors that cannot be completely controlled.

Soule, H A↗

Comparison of the US and Russian Cycle Ergometers

The purpose of this study was to compare the U.S. and Russian cycle ergometers focusing on the mechanical differences of the devices and the physiological differences observed while using the devices. Methods: First, the mechanical loads provided by the U.S. Cycle Ergometer with Vibration Isolation System (CEVIS) and the Russian Veloergometer were measured using a calibration dynamometer. Results were compared and conversion equations were modeled to determine the actual load provided by each device. Second, ten male subjects (32.9 +/- 6.5 yrs, 180.6 +/- 4.4 cm; 81.9 +/- 6.9 kg) experienced with both cycling and exercise testing completed a standardized submaximal exercise test protocol on CEVIS and Veloergometer. The exercise protocol involved 8 sub-maximal workloads each lasting 3 minutes for a total of 24 minutes per session, or until the end of the stage when the subject reached 85% of peak oxygen consumption or age-predicted maximum heart rate (220 - age). The workload started at 50 Watts (W), increased to 100 W, and then increased 25 W every 3 minutes until reaching a peak workload of 250 W. Physiological variables were then compared at each workload by repeated measures ANOVA or paired t-tests (p<0.05). Results: While both CEVIS and Veloergometer produced significantly lower workloads than the displayed workload, CEVIS produced even lower loads than Veloergometer (p<0.05) at each indicated workload. Despite this fact, the only physiological variables that showed a significant difference between the ergometers were VE (125 - 250W), VO2 (175 and 250 W), and VCO2 (175 W). All other physiological data were not statistically different between CEVIS and Veloergometer. Conclusion: Although workloads were different between ergometers, relatively few physiological differences were observed. Therefore, CEVIS workloads of 87.5 - 262.5 W can be rounded to the nearest 25 W increment and performed on the Veloergometer.

Norcross, Jason↗

High Pressure Quick Disconnect Particle Impact Tests

NASA Johnson Space Center White Sands Test Facility (WSTF) performed particle impact testing to determine whether there is a particle impact ignition hazard in the quick disconnects (QDs) in the Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS). Testing included standard supersonic and subsonic particle impact tests on 15-5 PH stainless steel, as well as tests performed on a QD simulator. This paper summarizes the particle impact tests completed at WSTF. Although there was an ignition in Test Series 4, it was determined the ignition was caused by the presence of a machining imperfection. The sum of all the test results indicates that there is no particle impact ignition hazard in the ISS ECLSS QDs. KEYWORDS: quick disconnect, high pressure, particle impact testing, stainless steel

Rosales, Keisa R.↗

Airvolt Aircraft Electric Propulsion Test Stand

Development of an electric propulsion test stand that collects high-fidelity data of motor, inverter, and battery system efficiencies; thermal dynamics; and acoustics independent of manufacturer reported values will improve understanding of electric propulsion systems to be used in future aircraft. A buildup approach to this development reveals new areas of research and best practices in testing, and attempts to establish a standard for testing these systems.

propulsion↗

Tests of T And CPT Symmetries at the B-Factories

Precision tests of the discrete symmetries T and CPT have been performed relying on large samples of clean events from e{sup +}e{sup -} annihilations, which have been collected by the Belle and BABAR B-factories. In particular, large samples of coherently produced B-meson pairs have provided especially favorable conditions for testing the Standard Model predictions regarding indirect T and CPT violation in B-mixing. The most interesting and recent results are reported in the following.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

International Standards Development and Its Role in Transitioning D and D Technologies to Deployment - 18315

As the need to perform deactivation and decommissioning (D and D) of the most challenging nuclear facilities worldwide is growing, facilitating the integration of state-of-the-art, cutting edge technologies will be critically important to safely, effectively, and efficiently complete this mission. However, end users in the field face significant obstacles to integrating new technologies into cleanup initiatives. By leveraging the development of international standards and testing protocols, the risks associated with implementing new technologies can be mitigated and further support the need to update existing directives and guidance handbooks to account for the tremendous recent advancements in technology development. The American Society for Testing and Materials (ASTM) International's E10.03 Subcommittee on Radiological Protection for D and D of Nuclear Facilities and Components has begun the development of standard specifications and uniform testing protocols designed to support the nuclear industry's testing and evaluation requirements for D and D technologies. The vision of the E10.03 Subcommittee is to promulgate operationally relevant, uniform testing protocols that can be leveraged by the various technology innovation and development programs across the nuclear environmental management community, and support decision makers and end users with common references in the selection and employment of those standards and associated technologies. These standards could also serve as the basis for updating existing directives and guidance documents such as the various DOE handbooks to better account for the role of cutting edge technology, and facilitate / expedite lab to market efforts that result in improved returns on investment (ROIs) for technology development programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Asymmetric dark matter annihilation as a test of non-standard cosmologies

We show that the relic abundance of the minority component of asymmetric dark matter can be very sensitive to the expansion rate of the Universe and the temperature of transition between a non-standard pre-Big Bang Nucleosynthesis cosmological phase and the standard radiation dominated phase, if chemical decoupling happens before this transition. In particular, because the annihilation cross section of asymmetric dark matter is typically larger than that of symmetric dark matter in the standard cosmology, the decrease in relic density of the minority component in non-standard cosmologies with respect to the majority component may be compensated by the increase in annihilation cross section, so that the annihilation rate at present of asymmetric dark matter, contrary to general belief, could be larger than that of symmetric dark matter in the standard cosmology. Thus, if the annihilation cross section of the asymmetric dark matter candidate is known, the annihilation rate at present, if detectable, could be used to test the Universe before Big Bang Nucleosynthesis, an epoch from which we do not yet have any data.

79 ASTRONOMY AND ASTROPHYSICS↗

Novel Protocol for Acute In Situ Ecotoxicity Test Using Native Crustaceans Applied to Groundwater Ecosystems

Current standardized laboratory test protocols use model species that have limitations to accurately assess native species responses to stressors. We developed and tested a novel acute in situ protocol for testing field-collected organisms. We used Asellus aquaticus and NaCl as a reference toxicant to test for the effects of location (laboratory vs. in situ), medium (synthetic vs. field water), substrate (presence vs. absence), and protocol replicability. We further tested the protocol using groundwater-adapted isopods: Proasellus assaforensis for the effect of location, P. cavaticus of medium and P.lusitanicus of substrate. Our results showed that A.aquaticus’ lethality obtained with the novel acute in situ protocol did not significantly differ from those from laboratory testing. However, laboratory tested P.assaforensis showed a higher sensitivity, suggesting that its acclimation to laboratory conditions might have pernicious effects. A. aquaticus and P. cavaticus showed a higher mortality using synthetic medium in situ and under laboratory conditions, which overestimated the stressor’s effect. Besides, substrate use had no significant effect. The novel acute in situ protocol allows the use of native species under realistic scenarios. It is particularly well adapted for assessing the risk of groundwater ecosystems but it can be applied to a wide range of ecosystems.

Castaño-Sánchez, Andrea↗

Physics with CEBAF at 12 GeV and future opportunities

Here, we summarize the ongoing scientific program of the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) and give an outlook into future opportunities. The program addresses important topics in nuclear, hadronic, and electroweak physics, including nuclear femtography, meson and baryon spectroscopy, quarks and gluons in nuclei, precision tests of the standard model and dark sector searches. Potential upgrades of CEBAF and their impact on scientific reach are discussed, such as higher luminosity, the addition of polarized and unpolarized positron beams, and doubling the beam energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation thermometer size-of-source effect testing using aperture

Size-of-source effect is an important attribute of any radiation thermometer. The effects of this attribute may be quantified in a number of different ways to include field-of-view, distance ratio, or size-of-source effect. These parameters provide needed information for the user of a radiation thermometer, as they aid in determining whether the measured object is large enough for adequate radiation thermometry measurement. Just as important, these parameters provide needed information for calibration. This information helps to determine calibration geometry, and it is needed for calibration uncertainty determination. For determination of size-of-source effect, there are a limited number of test methods furnished by the standards available today. The test methods available may be cumbersome to perform due to the cost of the required equipment and the time needed to set-up and perform the test. Other methods have been proposed. This paper discusses one such method. This method uses a circular aperture such as that used in radiation thermometer calibration. It describes the method both theoretically and mechanically. It then discusses testing done to verify this method comparing the results to those obtained while performing steps in current standards. Finally, based on this testing, the basis for a new standard test method is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗