Search NASA⌕ Search

SEARCH · Search NASA

Results for “time segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Jet transport energy management for minimum fuel consumption and noise impact in the terminal area

Significant reductions in both noise and fuel consumption can be gained through careful tailoring of approach flightpath and airspeed profile, and the point at which the landing gear and flaps are lowered. For example, the noise problem has been successfully attacked in recent years with development of the 'two-segment' approach, which brings the aircraft in at a steeper angle initially, thereby achieving noise reduction through lower thrust settings and higher altitudes. A further reduction in noise and a significant reduction in fuel consumption can be achieved with the 'decelerating approach' concept. In this case, the approach is initiated at high airspeed and in a drag configuration that allows for low thrust. The landing flaps are then lowered at the appropriate time so that the airspeed slowly decelerates to V sub r at touchdown. The decelerating approach concept can be applied to constant glideslope flightpaths or segmented flightpaths such as the two-segment approach.

Bull, J. S.↗

Root Influences on Mobilization and Export of Mineral-bound Soil Organic Matter

Biogeochemical cycles within mountainous watersheds are key regulators of ecosystem carbon storage and downstream nutrient loadings, and they have shown to be particularly vulnerable to climate change impacts. Increasing temperature and persistent droughts have already dramatically changed vegetation cover across the mountainous western US, with unknown consequences for soil carbon and nutrient cycles belowground. What remains elusive is to what extent associated changes in root-soil interactions may mobilize the vast pool of organic matter (OM) that has been stabilized by associations with minerals for centuries or millennia. Although plant root-driven OM mobilization from minerals may be a central control on carbon loss and nutrient export, such mechanisms are currently missing from conceptual and numerical models. The overall objective of this Exploratory Project is to identify the biogeochemical mechanisms by which roots destabilize mineral-associated organic matter (MAOM) and the cumulative impact on carbon and nutrient fate. To accomplish this goal, we integrated well-controlled laboratory experiments with in-field measurements and a scalable modeling approach. First, we conducted model system experiments to assess the vulnerability of MAOM to exudate-mediated mechanisms. Our results show that common root exudates effectively destabilize MAOM not only through direct, ligand-driven mobilization mechanisms, but also indirect, microbially-mediated mechanisms relying on secondary metabolites and enzymes. We further found that OM bound to poorly crystalline Fe and Al (hydr)oxides is more vulnerable to exudate-induced destabilization than OM bound to more crystalline phases, particularly in response to direct, ligand-promoted mechanisms. These findings demonstrate that the stability of MAOM is not just a function of their inherent properties, but also will depend in large parts on the ability of plant roots and microbes to produce exudates capable of triggering suitable mobilization mechanisms. We further employed a well-controlled rhizobox approach, combining advanced microsensor and mass spectrometry techniques, to resolve spatiotemporal variations in the composition and availability of exudates along single growing roots of grasses. Our results show that the composition of functionally relevant exudate compounds varies at extremely short time scales, seemingly shifting from ligands such as aromatic acids around root tips to less reactive metabolites such as amino acids around mature root segments. These results suggest a prevalence of direct MAOM mobilization mechanisms around the root tip, while indirect MAOM mobilization strategies may dominate around more mature root segments. Additionally, we utilized microsensor measurements in rhizoboxes to parameterize a rhizosphere (hydro)biogeochemistry reactive transport model (eSTOMP-ROOTS). The resulting model was used to assess how root exudations affects the stability of MAOM. Model simulations show that diel pulses of root exudation are strong enough to cause oscillations in biogeochemical conditions—particularly in pH, oxygen concentrations, and microbial activity— that repeatedly disrupt MAOM. Finally, we assessed field-scale impacts of root-driven MAOM destabilization over short and long time scales. A combination of in-field incubations and field-based characterizations showed that MAOM may not only be vulnerable to seasonal variations in root activity, but also to root-driven weathering over pedogenic time scales. In sum, results from our Exploratory Award highlight the strong control plant roots exert on MAOM mobilization and, thus, on the potential for carbon and nutrient export from watersheds.

54 ENVIRONMENTAL SCIENCES↗

Less is More: Bigger Data from Compressive Measurements

Compressive sensing approaches are beginning to take hold in (scanning) transmission electron microscopy (S/TEM) [1,2,3]. Compressive sensing is a mathematical theory about acquiring signals in a compressed form (measurements) and the probability of recovering the original signal by solving an inverse problem [4]. The inverse problem is underdetermined (more unknowns than measurements), so it is not obvious that recovery is possible. Compression is achieved by taking inner products of the signal with measurement weight vectors. Both Gaussian random weights and Bernoulli (0,1) random weights form a large class of measurement vectors for which recovery is possible. The measurements can also be designed through an optimization process. The key insight for electron microscopists is that compressive sensing can be used to increase acquisition speed and reduce dose. Building on work initially developed for optical cameras, this new paradigm will allow electron microscopists to solve more problems in the engineering and life sciences. We will be collecting orders of magnitude more data than previously possible. The reason that we will have more data is because we will have increased temporal/spatial/spectral sampling rates, and we will be able ability to interrogate larger classes of samples that were previously too beam sensitive to survive the experiment. For example consider an in-situ experiment that takes 1 minute. With traditional sensing, we might collect 5 images per second for a total of 300 images. With compressive sensing, each of those 300 images can be expanded into 10 more images, making the collection rate 50 images per second, and the decompressed data a total of 3000 images [3]. But, what are the implications, in terms of data, for this new methodology? Acquisition of compressed data will require downstream reconstruction to be useful. The reconstructed data will be much larger than traditional data, we will need space to store the reconstructions during analysis, and the computational demands for analysis will be higher. Moreover, there will be time costs associated with reconstruction. Deep learning [5] is an approach to address these problems. Deep learning is a hierarchical approach to find useful (for a particular task) representations of data. Each layer of the hierarchy is intended to represent higher levels of abstraction. For example, a deep model of faces might have sinusoids, edges and gradients in the first layer; eyes, noses, and mouths in the second layer, and faces in the third layer. There has been significant effort recently in deep learning algorithms for tasks beyond image classification such as compressive reconstruction [6] and image segmentation [7]. A drawback of deep learning, however, is that training the model requires large datasets and dedicated computational resources (to reduce training time to a few days). A second issue is that deep learning is not user-friendly and the meaning behind the results is usually not interpretable. We have shown it is possible to reduce the data set size while maintaining model quality [8] and developed interpretable models for image classification [9], but the demands are still significant. The key to addressing these problems is to NOT reconstruct the data. Instead, we should design computational sensors that give answers to specific problems. A simple version of this idea is compressive classification [10], where the goal is to classify signal type from a small number of compressed measurements. Classification is a much simpler problem than reconstruction, so 1) much fewer measurements will be necessary, and 2) these measurements will probably not be useful for reconstruction. Other simple examples of computational sensing include determining object volume or the number of objects present in the field of view [11].

Stevens, Andrew↗

Detailed analysis of latencies in image-based dynamic MLC tracking

Purpose: Previous measurements of the accuracy of image-based real-time dynamic multileaf collimator (DMLC) tracking show that the major contributor to errors is latency, i.e., the delay between target motion and MLC response. Therefore the purpose of this work was to develop a method for detailed analysis of latency contributions during image-based DMLC tracking. Methods: A prototype DMLC tracking system integrated with a linear accelerator was used for tracking a phantom with an embedded fiducial marker during treatment delivery. The phantom performed a sinusoidal motion. Real-time target localization was based on x-ray images acquired either with a portal imager or a kV imager mounted orthogonal to the treatment beam. Each image was stored in a file on the imaging workstation. A marker segmentation program opened the image file, determined the marker position in the image, and transferred it to the DMLC tracking program. This program estimated the three-dimensional target position by a single-imager method and adjusted the MLC aperture to the target position. Imaging intervals {Delta}T{sub image} from 150 to 1000 ms were investigated for both kV and MV imaging. After the experiments, the recorded images were synchronized with MLC log files generated by the MLC controller and tracking log files generated by the tracking program. This synchronization allowed temporal analysis of the information flow for each individual image from acquisition to completed MLC adjustment. The synchronization also allowed investigation of the MLC adjustment dynamics on a considerably finer time scale than the 50 ms time resolution of the MLC log files. Results: For {Delta}T{sub image}=150 ms, the total time from image acquisition to completed MLC adjustment was 380{+-}9 ms for MV and 420{+-}12 ms for kV images. The main part of this time was from image acquisition to completed image file writing (272 ms for MV and 309 ms for kV). Image file opening (38 ms), marker segmentation (4 ms), MLC position calculation (16 ms), and MLC adjustment (52 ms) were considerably faster. For {Delta}T{sub image}=1000 ms, the total time from image acquisition to completed MLC adjustment increased to 1030{+-}62 ms (MV) and 1330{+-}52 ms (kV) mainly because of delayed image file writing. The MLC adjustment duration was constant 52 ms ({+-}3 ms) for MLC adjustments below 1.1 mm and increased linearly for larger MLC adjustments. Conclusions: A method for detailed time analysis of each individual real-time position signal for DMLC tracking has been developed and applied to image-based tracking. The method allows identification of the major contributors to latency and therefore a focus for reducing this latency. The method could be an important tool for the reconstruction of the delivered target dose during DMLC tracking as it provides synchronization between target motion and MLC motion.

60 APPLIED LIFE SCIENCES↗

Reconstruction of implanted marker trajectories from cone-beam CT projection images using interdimensional correlation modeling

Purpose: Cone-beam CT (CBCT) is a widely used imaging modality for image-guided radiotherapy. Most vendors provide CBCT systems that are mounted on a linac gantry. Thus, CBCT can be used to estimate the actual 3-dimensional (3D) position of moving respiratory targets in the thoracic/abdominal region using 2D projection images. The authors have developed a method for estimating the 3D trajectory of respiratory-induced target motion from CBCT projection images using interdimensional correlation modeling. Methods: Because the superior–inferior (SI) motion of a target can be easily analyzed on projection images of a gantry-mounted CBCT system, the authors investigated the interdimensional correlation of the SI motion with left–right and anterior–posterior (AP) movements while the gantry is rotating. A simple linear model and a state-augmented model were implemented and applied to the interdimensional correlation analysis, and their performance was compared. The parameters of the interdimensional correlation models were determined by least-square estimation of the 2D error between the actual and estimated projected target position. The method was validated using 160 3D tumor trajectories from 46 thoracic/abdominal cancer patients obtained during CyberKnife treatment. The authors’ simulations assumed two application scenarios: (1) retrospective estimation for the purpose of moving tumor setup used just after volumetric matching with CBCT; and (2) on-the-fly estimation for the purpose of real-time target position estimation during gating or tracking delivery, either for full-rotation volumetric-modulated arc therapy (VMAT) in 60 s or a stationary six-field intensity-modulated radiation therapy (IMRT) with a beam delivery time of 20 s. Results: For the retrospective CBCT simulations, the mean 3D root-mean-square error (RMSE) for all 4893 trajectory segments was 0.41 mm (simple linear model) and 0.35 mm (state-augmented model). In the on-the-fly simulations, prior projections over more than 60° appear to be necessary for reliable estimations. The mean 3D RMSE during beam delivery after the simple linear model had established with a prior 90° projection data was 0.42 mm for VMAT and 0.45 mm for IMRT. Conclusions: The proposed method does not require any internal/external correlation or statistical modeling to estimate the target trajectory and can be used for both retrospective image-guided radiotherapy with CBCT projection images and real-time target position monitoring for respiratory gating or tracking.

60 APPLIED LIFE SCIENCES↗

Effect of dark pretreatment on the kinetics of response of barley pulvini to gravistimulation and hormones

Starch in pulvinus amyloplasts of barley (Hordeum vulgare cv Larker) disappears when 45-day-old, light-grown plants are given 5 days of continuous darkness. The effect of this loss on the pulvinus graviresponse was evaluated by following changes in the kinetics of response during the 5-day dark period. Over 5 days of dark pretreatment, the lag to initial graviresponse and the subsequent half-time to maximum steady state bending rate increased significantly while the maximum bending rate did not change. The change in response to applied indoleacetic acid (100 micromolar) plus gibberellic acid (10 micromolar) without gravistimulation, under identical dark pretreatments, was used as a model system for the response component of gravitropism. Dark pretreatment did not change the lag to initial response following hormone application to vertical pulvini, but both the maximum bending rate and the half-time to the maximum rate were significantly reduced. Also, after dark pretreatment, significant bending responses following hormone application were observed in vertical segments with or without added sucrose, while gravistimulation produced a response only if segments were given sucrose. These results indicate that starch-filled amyloplasts are required for the graviresponse of barley pulvini and suggest that they function in the stimulus perception and signal transduction components of gravitropism.

NASA Discipline Plant Biology↗

AUTOMATIC RETINA EXUDATES SEGMENTATION WITHOUT A MANUALLY LABELLED TRAINING SET

Diabetic macular edema (DME) is a common vision threatening complication of diabetic retinopathy which can be assessed by detecting exudates (a type of bright lesion) in fundus images. In this work, two new methods for the detection of exudates are presented which do not use a supervised learning step and therefore do not require ground-truthed lesion training sets which are time consuming to create, difficult to obtain, and prone to human error. We introduce a new dataset of fundus images from various ethnic groups and levels of DME which we have made publicly available. We evaluate our algorithm with this dataset and compare our results with two recent exudate segmentation algorithms. In all of our tests, our algorithms perform better or comparable with an order of magnitude reduction in computational time.

59 BASIC BIOLOGICAL SCIENCES↗

Designing Antifouling and Antimicrobial Interfaces: Structural Characterization using CryoEM, Automated Microscopy, and AI Image Segmentation

The design of functionalized surfaces for interactions with biological systems is critical across sectors such as healthcare, energy, and agriculture. Tailoring materials for specific applications, such as antifouling and antimicrobial surfaces, demands a comprehensive understanding of topology and chemistry across multiple length and time scales on both biological and materials systems. This work presents the development and characterization of nanostructured surfaces with controlled topographies and chemistries that enhance bacterial membrane disruption, reduce biofilm formation, and improve antimicrobial and antifouling capabilities. Two specific use cases will be presented - the use of cellulose nanocrystals (CNCs) for bacterial growth inhibition and the development of antifouling surfaces to prevent protein and bacterial adsorption [1-4]. By leveraging large language models (LLMs) for image segmentation and training [5], we enable automated analysis of terabyte-scale cryogenic electron microscopy (cryoEM) datasets. This analysis provides statistical insights into the biotic/abiotic interface and facilitates automated electron microscopy experiments to mitigate time and dose. The integration of cryogenic electron tomography (cryoET) and cryogenic focused ion beam (cryoFIB) milling enables high-resolution, near-native-state imaging and 3D reconstructions of bio/material interfaces [6]. Orthogonal characterization techniques and computational modeling further enhances our understanding, offering a robust platform for the design and optimization of next-generation functional surfaces [7].

Williams, Alexis [ORNL] (ORCID:0000000252835822)↗

Activated relaxation in supercooled monodisperse atomic and polymeric WCA fluids: Simulation and ECNLE theory

Here, we combine simulation and Elastically Collective Nonlinear Langevin Equation (ECNLE) theory to study the activated relaxation in monodisperse atomic and polymeric Weeks–Chandler–Andersen (WCA) liquids over a wide range of temperatures and densities in the supercooled regime under isochoric conditions. By employing novel crystal-avoiding simulations, metastable equilibrium dynamics is probed in the absence of complications associated with size polydispersity. Based on a highly accurate structural input from integral equation theory, ECNLE theory is found to describe well the simulated density and temperature dependences of the alpha relaxation time of atomic fluids using a single system-specific parameter, a c , that reflects the nonuniversal relative importance of local cage and collective elastic barriers. For polymer fluids, the explicit dynamical effect of local chain connectivity is modeled at the fundamental dynamic free energy trajectory level based on a different parameter, N c , that quantifies the degree of intramolecular correlation of bonded segment activated barrier hopping. For the flexible chain model studied, a physically intuitive value of N c ≈ 2 results in good agreement between simulation and theory. A direct comparison between atomic and polymeric systems reveals that chain connectivity can speed up activated segmental relaxation due to weakening of equilibrium packing correlations but can slow down relaxation due to local bonding constraints. The empirical thermodynamic scaling idea for the alpha time is found to work well at high densities or temperatures but fails when both density and temperature are low. The rich and subtle behaviors revealed from simulation for atomic and polymeric WCA fluids are all well captured by ECNLE theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of the homogeneity of the current distribution in a dielectric barrier discharge in air by means of a segmented electrode

The current distribution in a dielectric barrier discharge in atmospheric-pressure air at a natural humidity of 40–60% was studied experimentally with a time resolution of 200 ps. The experimental results are interpreted by means of numerically simulating the discharge electric circuit. The obtained results indicate that the discharge operating in the volumetric mode develops simultaneously over the entire transverse cross section of the discharge gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ground Segment Operations Concept for the Orion Artemis-2 Optical Communications System

The ACCESS Project (formerly Space Network) will implement an optical communications ground segment to support the Orion Artemis II Optical Communications (O2O) demonstration as part of the next manned human spaceflight mission to the moon, Artemis II. O2O implements laser communication (lasercomm) technology for operational use on the Orion series of spacecraft, as a development test objective (DTO), in order to demonstrate the feasibility and operational utility of lasercomm for human spaceflight missions. O2O consists of three segments: Space Segment, Ground Segment, and Operations Segment. The Space Segment consists of the Space Terminal Element and the Orion spacecraft. The Space Terminal Element effort is managed by the GSFC Laser-Enhanced Mission Communications Navigation and Operational Services (LEMNOS) project in collaboration with MIT Lincoln Laboratory. The Ground Segment consists of an optical ground terminal (GT) at the White Sands Complex (WSC), which is being developed in collaboration with MIT Lincoln Laboratory, the Ground Segment Operations and Analysis (GSOA) element and Ground Data Element (GDE), and a second optical GT in the Optical Communications Telescope Laboratory (OCTL) at the JPL Table Mountain Facility. The Operations Segment consists of the Artemis II Mission Control Center (MCC), the Lasercomm Space Terminal Console (LSTC), and the Lasercomm Link Planning & Analysis Center (LPAC), all located at the Johnson Space Center (JSC). O2O utilizes pulse-position modulation (PPM) direct-to-earth services resulting in an 80 Mbps downlink data rate from lunar orbit. The O2O concept of operations is to provide optical services for a minimum of 1 hour per day for each day of the Artemis II mission. O2O will utilize a 10-20 Mbps uplink data rate and 40-260 Mbps downlink data rate, depending on the Artemis II mission phase. The ACCESS project will also provide a centralized mission data interface for user data distribution and storage to the MCC and perform planning and scheduling of services in coordination with the Operations Segment for the O2O Ground Segment. The O2O Ground Segment will support the following O2O mission phases: Pre-Mission Planning; Daily Operations Planning; Event Execution; and Post-Pass Reporting. O2O will be used to exchange data files between Orion and the MCC and to distribute real-time video through the optical downlink service to the MCC; which would not be possible without the high-bandwidth link that O2O will provide to Orion. In this paper, I will discuss the O2O Ground Segment development approach and how it will support these critical O2O functions: plan and schedule the contact; acquire and track the optical link; flow information bidirectionally; distribute information; and control and accommodate the system.

optical communications↗

Evolution of the East Pacific Rise between 3°S and 13°S since the Middle Miocene

Since Middle Miocene time seafloor spreading activity in the southeast Pacific has shifted westward from the Galapagos Rise, then the last active segment of the Farallon Ridge system in the South Pacific, to the East Pacific Rise. This shift was accomplished by three large jumps of fracture‐zone‐bound axial sections which progressed from south to north. The jumps spanned an average distance of 750 km and occurred 8.2, 6.4 and 5.7 m.y. ago respectively. Positioning of the newly‐formed axes along the EPR trend apparently was controlled by asthenospheric rather than lithospheric phenomena.

58 GEOSCIENCES↗

The New Position Sensitive Triple Cluster Detector For AGATA

The first triple cluster detector was successfully assembled for the next generation high-resolution gamma-ray spectrometer: the Advanced Gamma Tracking Array AGATA. The core part of the detector consists of three encapsulated, 36-fold segmented, high-purity germanium detectors (HPGe) which are operated in a common cryostat. All 111 energy channels are equipped with cold FETs. They provide best energy resolution of core and segment signals. The observable energy range of the Ge detectors was extended up to 100 MeV by applying a time over threshold technique with the newly developed AGATA preamplifiers. Energy resolution for high energetic {gamma}-rays above 10 MeV is measured to be comparable with values obtained with the standard pulse height technique. Detailed cross-talk investigations were performed in order to improve position dependent pulse shape information. For the Ge detectors and its analog preamplifier circuitry a low cross-talk level was determined which compares well with the expected calculated contributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ground motion response to an ML 4.3 earthquake using co-located distributed acoustic sensing and seismometer arrays

The PoroTomo research team deployed two arrays of seismic sensors in a natural laboratory at Brady Hot Springs, Nevada in March 2016. The 1500 m (length) by 500 m (width) by 400 m (depth) volume of the laboratory overlies a geothermal reservoir. The surface Distributed Acoustic Sensing (DAS) array consisted of 8700 m of fiber-optic cable in a shallow trench, including 340 m in a well. The conventional seismometer array consisted of 238 three- component geophones. The DAS cable was laid out in three parallel zig-zag lines with line segments approximately 100 meters in length and geophones were spaced at approximately 60- meter intervals. Both DAS and conventional geophones recorded continuously over 15 days during which a moderate-sized earthquake with a local magnitude of 4.3 was recorded on March 21, 2016. Its epicenter was approximately 150-km south-southeast of the laboratory. Several DAS line segments with co-located geophone stations were used to compare signal-to-noise (SNR) ratios in both time and frequency domains and to test relationships between DAS and geophone data. The ratios were typically within a factor of five of each other with DAS SNR often greater for P-wave but smaller for S-wave relative to geophone SNR. The SNRs measured for an earthquake can be better than for active sources, because the earthquake signal contains more low frequency energy and the noise level is also lower at those lower frequencies. Amplitudes of the sum of several DAS strain-rate waveforms matched the finite difference of two geophone waveforms reasonably well, as did the amplitudes of DAS strain waveforms with particle-velocity waveforms recorded by geophones. Similar agreement was found between DAS and geophone observations and synthetic strain seismograms. In conclusion, the combination of good SNR in the seismic frequency band, high-spatial density, large N, and highly accurate time control among individual sensors suggests that DAS arrays have potential to assume a role in earthquake seismology.

60 signal-to-noise ratio↗

Semantic segmentation with a sparse convolutional neural network for event reconstruction in MicroBooNE

We present the performance of a semantic segmentation network, SparseSSNet, that provides pixel-level classification of MicroBooNE data. The MicroBooNE experiment employs a liquid argon time projection chamber for the study of neutrino properties and interactions. SparseSSNet is a submanifold sparse convolutional neural network, which provides the initial machine learning based algorithm utilized in one of MicroBooNE's ν e -appearance oscillation analyses. The network is trained to categorize pixels into five classes, which are re-classified into two classes more relevant to the current analysis. The output of SparseSSNet is a key input in further analysis steps. This technique, used for the first time in liquid argon time projection chambers data and is an improvement compared to a previously used convolutional neural network, both in accuracy and computing resource utilization. Here, the accuracy achieved on the test sample is ≥ 99%. For full neutrino interaction simulations, the time for processing one image is ≈ 0.5 sec, the memory usage is at 1 GB level, which allows utilization of most typical CPU worker machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Updated constraints on the cosmic string tension

We reexamine the constraints on the cosmic string tension from cosmic microwave background (CMB) and matter power spectra, and also from limits on a stochastic background of gravitational waves provided by pulsar timing. We discuss the different approaches to modeling string evolution and radiation. In particular, we show that the unconnected segment model can describe CMB spectra expected from thin string (Nambu) and field theory (Abelian-Higgs) simulations using the computed values for the correlation length, rms string velocity and small-scale structure relevant to each variety of simulation. Applying the computed spectra in a fit to CMB and SDSS data we find that G{mu}/c{sup 2}<2.6x10{sup -7} (2{sigma}) if the Nambu simulations are correct and G{mu}/c{sup 2}<6.4x10{sup -7} in the Abelian-Higgs case. The degeneracy between G{mu}/c{sup 2} and the power spectrum slope n{sub S} is substantially reduced from previous work. Inclusion of constraints on the baryon density from big bang nucleosynthesis (BBN) imply that n{sub S}<1 at around the 4{sigma} level for both the Nambu and Abelian-Higgs cases. As a by-product of our results, we find there is ''moderate-to-strong'' Bayesian evidence that the Harrison-Zel'dovich spectrum is excluded (odds ratio of {approx}100 ratio 1) by the combination of CMB, SDSS, and BBN when compared to the standard 6 parameter fit. Using the contribution to the gravitational wave background from radiation era loops as a conservative lower bound on the signal for specific values of G{mu}/c{sup 2} and loop production size, {alpha}, we find that G{mu}/c{sup 2}<7x10{sup -7} for {alpha}c{sup 2}/({Gamma}G{mu})<<1 and G{mu}/c{sup 2}<5x10{sup -11}/{alpha} for {alpha}c{sup 2}/({Gamma}G{mu})>>1.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-A-BRF-03: Evaluation of Synthetic CTs Generated Using MR-SIM Data

Purpose: To describe and evaluate a novel algorithm for generating synthetic CT images from MR-SIM data for dose calculations in MR-only treatment planning. Methods: A voxel-based weighted summation method was implemented to generate synthetic CT (synCT) images. MR data were acquired using Philips 1.0T Panorama high-field open MR-SIM. Retrospective patient data from seven prostate patients and one brain patient (three lesions) enrolled in an IRB-approved study were used. 3D T1-weighted fast field echo and 3D T2-weighted turbo spin echo sequences were utilized for all patients. A 3D balanced turbo field echo sequence using spectral presaturation with inversion recovery was acquired for prostate patients, but 3D ultra-short echo time (UTE)-DIXON was instead acquired for the brain patient to amplify bone signal for semi-automatic bone segmentation. Weight optimization was performed using a training subset of patients. HU value differences between planning CT and synCTs were analyzed using mean absolute error (MAE). Original patient CT-based treatment plans were mapped onto synCTs, dose was recalculated using original leaf motion and MU values, and DRRs were generated. Dosevolume metrics and gamma analysis were used for dosimetric evaluation. Results: Average whole-body MAE of synCTs across all patients was 75+12 HU. In prostate cancer patients, average HU difference between planning and synCTs was 0.9±1.0% for soft tissue structures and 4.3±2.5% for bony structures. DRRs were generated from synCTs and qualitatively showed good geometric agreement with planning CT-generated DRRs. D99, mean dose, and maximum dose to CTV calculated using the synCT remained within 1.2% of planning CT-based dose calculations. All gamma analysis evaluated at 2%/2mm dose difference/distance to agreement) pass rates were greater than 95% with an average of 99.9±0.1% for prostate patients and 98.4±2.2% for three brain lesions. Conclusion: SynCTs were generated with clinically acceptable accuracy comparable to planning CTs, enabling dose computations for MR-only simulation. Research supported in part by a grant from Philips HealthCare (Best, Netherlands)

60 APPLIED LIFE SCIENCES↗