Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Analytical and experimental spur gear tooth temperature as affected by operating variables

A gear tooth temperature analysis was performed using a finite element method combined with a calculated heat input, calculated oil jet impingement depth, and estimated heat transfer coefficients. Experimental measurements of gear tooth average surface temperatures and instanteous surface temperatures were made with a fast response infrared radiometric microscope. Increased oil jet pressure had a significant effect on both average and peak surface temperatures at both high load and speeds. Increasing the speed at constant load and increasing the load at constant speed causes a significant rise in average and peak surface temperatures of gear teeth. The oil jet pressure required for adequate cooling at high speed and load conditions must be high enough to get full depth penetration of the teeth. Calculated and experimental results were in good agreement with high oil jet penetration but showed poor agreement with low oil jet penetration depth.

Townsend, D. P.↗

Analytical and experimental spur gear tooth temperature as affected by operating variables

A gear tooth temperature analysis was performed using a finite element method combined with a calculated heat input, calculated oil jet impingement depth, and estimated heat transfer coefficients. Experimental measurements of gear tooth average surface temperatures and instantaneous surface temperatures were made with a fast response infrared radiometric microscope. Increased oil jet pressure had a significant effect on both average and peak surface temperatures at both high load and speeds. Increasing the speed at constant load and increasing the load at constant speed causes a significant rise in average and peak surface temperatures of gear teeth. The oil jet pressure required for adequate cooling at high speed and load conditions must be high enough to get full depth penetration of the teeth. Calculated and experimental results were in good agreement with high oil jet penetration but showed poor agreement with low oil jet penetration depth.

Townsend, D. P.↗

Data-Driven Chance-Constrained Design of Voltage Droop Control for Distribution Networks: Preprint

This paper addresses the design of local control methods for voltage control in distribution networks with high level of distributed energy resources (DERs). The designed control methods adapt the active and reactive power output of distributed energy resources proportional to the deviation of the local measured voltage magnitudes from a reference voltage, which is referred to as droop control. Thus, the design focuses on determining the droop characteristics which satisfy network-wide voltage magnitude constraints. The uncertainty and variability of DERs renders the design of optimal droop controls very challenging. Hence, this paper proposes chance constraints to limit the risk from intermittent DERs, by designing droop control coefficients that guarantee the satisfaction of network operational constraints with a specific probability. In addition, the proposed approach relies entirely on historical data rather than assuming knowledge of the probability distributions that characterize the uncertainty of DERs. The efficacy of the proposed method is demonstrated on a 37-bus distribution feeder.

chance-constrained optimization↗

The electron diffusion coefficient in Jupiter's magnetosphere

A steady-state model of Jupiter's electron radiation belt is developed. The model includes injection from the solar wind, radial diffusion, energy degradation by synchrotron radiation, and absorption at Jupiter's surface. A diffusion coefficient of the form D sub RR/R sub J squared = k times R to the m-th power is assumed, and then observed data on synchrotron radiation are used to fit the model. The free parameters determined from this fit are m = 1.95 plus or minus 0.5, k = 1.7 plus or minus 0.5 x 10 to the 9th power per sec, and the magnetic moment of injected particles equals 770 plus or minus 300 MeV/G. The value of m shows quite clearly that the diffusion is not caused by magnetic pumping by a variable solar wind or by a fluctuating convection electric field. The process might be field line exchange driven by atmospheric-ionospheric winds; our diffusion coefficient has roughly the same radial dependence but is considerably smaller in magnitude than the upper bound diffusion coefficients recently suggested for this process by Brice and McDonough (1973) and Jacques and Davis (1972).

Birmingham, T.↗

Variability of collagen crosslinks: impact of sample collection period

Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P < 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.

Specimen Handling/methods↗

Theory versus experiment for the rotordynamic coefficients of labyrinth gas seals. I - A two control volume model

The basic equations are derived for a two-control-volume model for compressible flow in a labyrinth seal. The recirculation velocity in the cavity is incorporated into the model for the first time. The flow is assumed to be completely turbulent and isoenergetic. The wall friction factors are determined using the Blasius formula. Jet flow theory is used for the calculation of the recirculation velocity in the cavity. Linearized zeroth- and first-order perturbation equations are developed for small motion about a centered position by an expansion in the eccentricity ratio. The zeroth-order pressure distribution is found by satisfying the leakage equation while the circumferential velocity distribution is determined by satisfying the momentum equations. The first-order equations are solved by a separation of variable solution. Integration of the resultant pressure distribution along and around the seal defines the reaction force developed by the seal and the corresponding dynamic coefficients.

Scharrer, J. K.↗

Computational thermodynamics and its applications

Thermodynamics is a science concerning the state of a system, whether it is stable, metastable or un- stable, when interacting with the surroundings. In this overview, fundamentals of thermodynamics are briefly reviewed through the combination of first and second laws of thermodynamics for open and nonequilibrium systems to demonstrate that the reversible equilibrium and irreversible nonequilibrium thermodynamics can be integrated to enhance the power and utilities of thermodynamics. The recent progresses in computational thermodynamics, the remaining challenges, and potential impacts in broad scientific fields are discussed here. It is shown that computational thermodynamics enables the modeling of thermodynamics of a state as a function of both external and internal variables and quantitative calculations of a broad range of properties of a multicomponent system in terms of first and second derivatives of energy, including not only equilibrium states when there are no driving forces for any internal processes and but also non-equilibrium states with driving forces for internal processes. Consequently, external constraints such as fixed strain and internal degree of freedoms such as ordering and defects can be described in a coherent framework and applied to materials design. Furthermore, two important but largely overlooked aspects in thermodynamics will be discussed, i.e. the rigorous application of statistical thermodynamics with the probability of configurations and their contributions to system properties, and the applications of second derivatives of energy with respect to either two extensive variables or two potentials or a mixture of them in terms of understanding and predicting emergent behaviors, critical phenomena, kinetic coefficients, and mechanical properties.

36 MATERIALS SCIENCE↗

Scalable domain decomposition solvers for stochastic PDEs in high performance computing

Stochastic spectral finite element models of practical engineering systems may involve solutions of linear systems or linearized systems for non-linear problems with billions of unknowns. For stochastic modeling, it is therefore essential to design robust, parallel and scalable algorithms that can efficiently utilize high-performance computing to tackle such large-scale systems. Domain decomposition based iterative solvers can handle such systems. And though these algorithms exhibit excellent scalabilities, significant algorithmic and implementational challenges exist to extend them to solve extreme-scale stochastic systems using emerging computing platforms. Intrusive polynomial chaos expansion based domain decomposition algorithms are extended here to concurrently handle high resolution in both spatial and stochastic domains using an in-house implementation. Sparse iterative solvers with efficient preconditioners are employed to solve the resulting global and subdomain level local systems through multi-level iterative solvers. We also use parallel sparse matrix–vector operations to reduce the floating-point operations and memory requirements. Numerical and parallel scalabilities of these algorithms are presented for the diffusion equation having spatially varying diffusion coefficient modeled by a non-Gaussian stochastic process. Scalability of the solvers with respect to the number of random variables is also investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions

Purpose: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiplexed Cancer Biomarker Detection Using Quartz-based Photonic Crystal Surfaces

A photonic crystal (PC) surface is demonstrated as a high-sensitivity platform for detection of a panel of 21 cancer biomarker antigens using a sandwich enzyme-linked immunosorbent assay (ELISA) microarray format. A quartz-based PC structure fabricated by nanoimprint lithography, selected for its low autofluorescence, supports two independent optical resonances that simultaneously enable enhancement of fluorescence detection of biomarkers and label-free quantification of the density of antibody capture spots. A detection instrument is demonstrated that supports fluorescence and label-free imaging modalities, with the ability to optimize the fluorescence enhancement factor on a pixel-by-pixel basis throughout the microarray using an angle-scanning approach for the excitation laser that automatically compensates for variability in surface chemistry density and capture spot density. Measurements show that the angle-scanning illumination approach reduces the coefficient of variation of replicate assays by 20–99% compared to ordinary fluorescence microscopy, thus supporting reduction in limits of detectable biomarker concentration. Using the PC resonance, biomarkers in mixed samples were detectable at the lowest concentrations tested (2.1–41 pg/mL), resulting in a three-log range of quantitative detection.

Huang, Cheng-Sheng↗

Thermophysical properties of liquid Ni around the melting temperature from molecular dynamics simulation

Thermophysical properties of liquid nickel (Ni) around the melting temperature are investigated by means of classical molecular dynamics (MD) simulation, using three different embedded atom method potentials to model the interactions between the Ni atoms. Melting temperature, enthalpy, static structure factor, self-diffusion coefficient, shear viscosity, and thermal diffusivity are compared to recent experimental results. Using ab initio MD simulation, we also determine the static structure factor and the mean-squared displacement at the experimental melting point. For most of the properties, excellent agreement is found between experiment and simulation, provided the comparison relative to the corresponding melting temperature. We discuss the validity of the Hansen-Verlet criterion for the static structure factor as well as the Stokes-Einstein relation between self-diffusion coefficient and shear viscosity. The thermal diffusivity is extracted from the autocorrelation function of a wavenumber-dependent temperature fluctuation variable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gravitational, shear and matter waves in Kantowski-Sachs cosmologies

A general treatment of vorticity-free, perfect fluid perturbations of Kantowski-Sachs models with a positive cosmological constant are considered within the framework of the 1+1+2 covariant decomposition of spacetime. The dynamics is encompassed in six evolution equations for six harmonic coefficients, describing gravito-magnetic, kinematic and matter perturbations, while a set of algebraic expressions determine the rest of the variables. The six equations further decouple into a set of four equations sourced by the perfect fluid, representing forced oscillations and two uncoupled damped oscillator equations. The two gravitational degrees of freedom are represented by pairs of gravito-magnetic perturbations. In contrast with the Friedmann case one of them is coupled to the matter density perturbations, becoming decoupled only in the geometrical optics limit. In this approximation, the even and odd tensorial perturbations of the Weyl tensor evolve as gravitational waves on the anisotropic Kantowski-Sachs background, while the modes describing the shear and the matter density gradient are out of phase dephased by π /2 and share the same speed of sound.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical Analysis of 2-D and 3-D MHD Flows Relevant to Fusion Applications

Here, the analysis of many fusion applications such as liquid-metal blankets requires application of computational fluid dynamics (CFD) methods for electrically conductive liquids in geometrically complex regions and in the presence of a strong magnetic field. A current state of the art general purpose CFD code allows modeling of the flow in complex geometric regions, with simultaneous conjugated heat transfer analysis in liquid and surrounding solid parts. Together with a magnetohydrodynamics (MHD) capability, the general purpose CFD code will be a valuable tool for the design and optimization of fusion devices. This paper describes an introduction of MHD capability into the general purpose CFD code CFX, part of the ANSYS Workbench. The code was adapted for MHD problems using a magnetic induction approach. CFX allows introduction of user-defined variables using transport or Poisson equations. For MHD adaptation of the code three additional transport equations were introduced for the components of the magnetic field, in addition to the Poisson equation for electric potential. The Lorentz force is included in the momentum transport equation as a source term. Fusion applications usually involve very strong magnetic fields, with values of the Hartmann number of up to tens of thousands. In this situation a system of MHD equations become very rigid with very large source terms and very strong variable gradients. To increase system robustness, special measures were introduced during the iterative convergence process, such as linearization using source coefficient for momentum equations. The MHD implementation in general purpose CFD code was tested against benchmarks, specifically selected for liquid-metal blanket applications. Results of numerical simulations using present implementation closely match analytical solutions for a Hartmann number of up to 1500 for a 2-D laminar flow in the duct of square cross section, with conducting and nonconducting walls. Results for a 3-D test case are also included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-159: Intra-Patient Deformable Image Registration Uncertainties Quantified Using the Distance Discordance Metric

Purpose: The quantitative evaluation of deformable image registration (DIR) is currently challenging due to lack of a ground truth. In this study we test a new method proposed for quantifying multiple-image based DIRrelated uncertainties, for DIR of pelvic images. Methods: 19 patients were analyzed, each with 6 CT scans, who previously had radiotherapy for prostate cancer. Manually delineated structures for rectum and bladder, which served as ground truth structures, were delineated on the planning CT and each subsequent scan. For each patient, voxel-by-voxel DIR-related uncertainties were evaluated, following B-spline based DIR, by applying a previously developed metric, the distance discordance metric (DDM; Saleh et al., PMB (2014) 59:733). The DDM map was superimposed on the first acquired CT scan and DDM statistics were assessed, also relative to two metrics estimating the agreement between the propagated and the manually delineated structures. Results: The highest DDM values which correspond to greatest spatial uncertainties were observed near the body surface and in the bowel due to the presence of gas. The mean rectal and bladder DDM values ranged from 1.1–11.1 mm and 1.5–12.7 mm, respectively. There was a strong correlation in the DDMs between the rectum and bladder (Pearson R = 0.68 for the max DDM). For both structures, DDM was correlated with the ratio between the DIR-propagated and manually delineated volumes (R = 0.74 for the max rectal DDM). The maximum rectal DDM was negatively correlated with the Dice Similarity Coefficient between the propagated and the manually delineated volumes (R= −0.52). Conclusion: The multipleimage based DDM map quantified considerable DIR variability across different structures and among patients. Besides using the DDM for quantifying DIR-related uncertainties it could potentially be used to adjust for uncertainties in DIR-based accumulated dose distributions.

60 APPLIED LIFE SCIENCES↗

A fast numerical method for determining the optimum SNR of an array subject to a Q factor constraint.

The problem of finding the optimum current excitations for a point-detector array which extracts a signal from background noise using the criterion of maximizing the SNR subject to a constraint on the supergain ratio (or Q factor) has recently been solved. The formulation reduced the problem to one of solving for the roots of a polynomial whose coefficients are, in general, complex. We demonstrate that by making a certain transformation, it becomes possible to employ a state variable technique which changes the problem into one of finding the eigenvalues of a real matrix which is considerably faster to do.

Winkler, L. P.↗

Statistical methods for astronomical data with upper limits. II - Correlation and regression

Statistical methods for calculating correlations and regressions in bivariate censored data where the dependent variable can have upper or lower limits are presented. Cox's regression and the generalization of Kendall's rank correlation coefficient provide significant levels of correlations, and the EM algorithm, under the assumption of normally distributed errors, and its nonparametric analog using the Kaplan-Meier estimator, give estimates for the slope of a regression line. Monte Carlo simulations demonstrate that survival analysis is reliable in determining correlations between luminosities at different bands. Survival analysis is applied to CO emission in infrared galaxies, X-ray emission in radio galaxies, H-alpha emission in cooling cluster cores, and radio emission in Seyfert galaxies.

Isobe, T.↗

The global structure of the annual and semiannual sea surface height variability from Geosat altimeter data

Two years of data from the Geosat Exact Repeat Mission are employed to study the annual and semiannual variability of sea-surface height on a global basis. The data are treated with atmospheric corrections and interpolations, and the orbit error of about 40 cm RMS is purged. The spatial variability of the Geosat data is constructed for particular frequencies, and the estimate of the M2 tidal error indicates that the error is aliased to 1.15 cycles/yr and has an unusual spatial pattern. Sine and cosine coefficients are derived for the annual and semiannual frequencies by means of a least squares fit yielding the amplitude and phase of the changes in sea-surface height. A 180-deg phase difference is noted between the Northern and Southern Hemispheres for the annual variability, and large-scale westward propagating waves are identified. The Geosat data also indicate the phase relationships between major current systems and the systems of variations at work in the Intertropical Convergence Zone.

Jacobs, Gregg A.↗

Comparison of experimental with theoretical total-pressure loss in parallel-walled turbojet combustors

An experimental investigation of combustor total-pressure loss was undertaken to confirm previous theoretical analyses of effects of geometric and flow variables and of heat addition. The results indicate that a reasonable estimate of cold-flow total-pressure-loss coefficient may be obtained from the theoretical analyses. Calculated total-pressure loss due to heat addition agreed with experimental data only when there was no flame ejection from the liner at the upstream air-entry holes.

Dittrich, Ralph T↗