Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Determining Individual Phase Flow Properties in a Quench and Partitioning Steel with In Situ High-Energy X-Ray Diffraction and Multiphase Elasto-Plastic Self-Consistent Method

The micromechanical properties of the constituent phases were characterized for an advanced high strength steels (AHSS) produced by a quenching and partitioning (Q&P) process with in-situ tensile loading under Synchrotron-based high energy X-ray diffraction. The constituent phases present are retained austenite and three martensites (tempered, untempered and freshly formed martensites). For the material investigated, the 200 and 220 lattice strains of the retained austenite phase were calculated by examining the changes of the X-ray diffraction peak positions during deformation. The 200 and 211 lattice strains of the various martensitic phases with similar crystal structures were determined by separating their overlapped diffraction peaks. Apart from tempered and untempered martensite, the diffraction peaks of freshly formed martensite as a result of austenite to martensite transformation can also be able separated due to high initial austenite volume fraction. The phase stresses are first estimated with an empirical relationship through the X-ray diffraction elastic constants (XREC). A multi-phase elasto-plastic self constant model (EPSC) is next used for more accurate determination of the constitutive behaviors of the various phases by comparing the predicted lattice strain distributions and global stress-strain curves with the measured ones. The determined constitutive laws will be used for microstructure-based modeling for sheet formability of the Q&P AHSS steel.

Hu, Xiaohua↗

Inference of the phase-to-mechanical property link via coupled X-ray spectrometry and indentation analysis: Application to cement-based materials

A novel approach for the chemo-mechanical characterization of cement-based materials is presented, which combines the classical grid indentation technique with elemental mapping by scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDS). It is illustrated through application to an oil-well cement system with siliceous filler. The characteristic X-rays of major elements (silicon, calcium and aluminum) are measured over the indentation region and mapped back on the indentation points. Measured intensities together with indentation hardness and modulus are considered in a clustering analysis within the framework of Finite Mixture Models with Gaussian component density function. The method is able to successfully isolate the calcium-silica-hydrate gel at the indentation scale from its mixtures with other products of cement hydration and anhydrous phases; thus providing a convenient means to link mechanical response to the calcium-to-silicon ratio quantified independently via X-ray wavelength dispersive spectroscopy. A discussion of uncertainty quantification of the estimated chemo-mechanical properties and phase volume fractions, as well as the effect of chemical observables on phase assessment is also included.

36 MATERIALS SCIENCE↗

Phase assemblage of composite cements

The phase assemblage of binary Portland cements with 45 wt% replacement by calcareous fly ash and slag has been investigated by experiment, mass balance and thermodynamic simulations. The input for these calculations was based on clinker reaction measured by XRD-Rietveld refinement, on SCM reaction measured by SEM-EDS full element mapping and on C-S-H composition by SEM-EDS point analyses. A sensitivity analysis estimates the uncertainty of determination of phase volume as at best ± 2 cm{sup 3}/100 cm{sup 3}, and thus of rather semi-quantitative character. The differences between experiment and calculations regarding AFt/AFm, C-S-H and portlandite were assessed. Gel/space ratios computed using the volumes of all hydrates showed a clear correlation to compressive strength, which was unaffected by the mix composition. This suggests that the type of hydrates formed has little or no influence on the compressive strength and that the key factor is the space filling.

36 MATERIALS SCIENCE↗

Margin on Gross Tumor Volume and Risk of Local Recurrence in Head-and-Neck Cancer

Purpose: To determine whether the method or extent of construction of the high-dose clinical target volume (CTV) and high-dose planning target volume (PTV) in intensity-modulated radiation therapy (IMRT) for head-and-neck cancer are associated with an increased risk of locoregional failure. Materials and Methods: Patients with nasopharyngeal, oropharyngeal, oral cavity, hypopharyngeal, or laryngeal squamous cell carcinomas treated definitively with IMRT were included. All patients without local relapse had a minimum follow-up of 12 months. Median follow-up for all patients was 24 months. Treatment plans of 85 available patients were reviewed, and the gross tumor volume (GTV) to PTV expansion method was estimated. Results: The GTVs were expanded volumetrically in 71 of 85 patients, by a median of 15 mm (range, 4-25 mm). An anatomic component to the expansion of GTV was used in 14 of 85 patients. Eighteen patients failed locoregionally, for an actuarial locoregional control rate of 77.2% at 2 years. There was no significant difference in locoregional control between patients with GTVs expanded volumetrically vs. those with a component of anatomic expansion. In patients with GTVs expanded volumetrically, no increase in risk of local failure was seen in patients with a total GTV expansion of <=15 mm. Conclusion: In this retrospective study, there was not an increased risk of local failure using smaller margins or expanding GTVs volumetrically when treating head-and-neck cancer patients definitively with IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Markerless Technique to Evaluate Daily Lung Tumor Motion Based on Conventional Cone-Beam CT Projection Data

Purpose: In this study, we present a novel markerless technique, based on cone beam computed tomography (CBCT) raw projection data, to evaluate lung tumor daily motion. Method and Materials: The markerless technique, which uses raw CBCT projection data and locates tumors directly on every projection, consists of three steps. First, the tumor contour on the planning CT is used to create digitally reconstructed radiographs (DRRs) at every projection angle. Two sets of DRRs are created: one showing only the tumor, and another with the complete anatomy without the tumor. Second, a rigid two-dimensional image registration is performed to register the DRR set without the tumor to the CBCT projections. After the registration, the projections are subtracted from the DRRs, resulting in a projection dataset containing primarily tumor. Finally, a second registration is performed between the subtracted projection and tumor-only DRR. The methodology was evaluated using a chest phantom containing a moving tumor, and retrospectively in 4 lung cancer patients treated by stereotactic body radiation therapy. Tumors detected on projection images were compared with those from three-dimensional (3D) and four-dimensional (4D) CBCT reconstruction results. Results: Results in both static and moving phantoms demonstrate that the accuracy is within 1 mm. The subsequent application to 22 sets of CBCT scan raw projection data of 4 lung cancer patients includes about 11,000 projections, with the detected tumor locations consistent with 3D and 4D CBCT reconstruction results. This technique reveals detailed lung tumor motion and provides additional information than conventional 4D images. Conclusion: This technique is capable of accurately characterizing lung tumor motion on a daily basis based on a conventional CBCT scan. It provides daily verification of the tumor motion to ensure that these motions are within prior estimation and covered by the treatment planning volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Predictors of Patient-Reported Xerostomia and Dysphagia With Deintensified Chemoradiation Therapy for HPV-Associated Oropharyngeal Squamous Cell Carcinoma

Purpose/Objective(s): To estimate the association between different dose-volume metrics of the salivary glands and pharyngeal constrictors with patient reported severity of xerostomia/dysphagia in the setting of deintensified chemoradiation therapy (CRT). Methods and Materials: Forty-five patients were treated on a phase 2 study assessing the efficacy of deintensified CRT for favorable-risk, HPV-associated oropharyngeal squamous cell carcinoma. Patients received 60 Gy intensity modulated radiation therapy with concurrent weekly cisplatin (30 mg/m{sup 2}), and reported the severity of their xerostomia/dysphagia (before and after treatment) using the patient-reported outcome version of the Common Terminology Criteria for Adverse Events (CTCAE) (PRO-CTCAE). Individual patient dosimetric data of the contralateral parotid and submandibular glands and pharyngeal constrictors were correlated with changes in PRO-CTCAE severity. A change in severity (from baseline) of ≥2 was considered clinically meaningful. Associations between dose-volume metrics and patient outcomes were assessed with receiver operating characteristic (ROC) curve and logistic regression model. Results: Six months after CRT, patients reporting <2 change in xerostomia severity (n=14) had an average D{sub mean} = 22 ± 9 Gy to the sum of the contralateral glands (parotid + submandibular) compared with the patients reporting ≥2 change (n=21), who had an average D{sub mean} = 34 ± 8 Gy. V15 to V55 for the combined contralateral glands showed the strongest association with xerostomia (area under the curve [AUC] = 0.83-0.86). Based on the regression analysis, a 20% risk of toxicity was associated with V15 = 48%, V25 = 30%, and D{sub mean}=21 Gy. Six months after CRT, patients reporting <2 change in dysphagia severity (n=26) had an average V55 = 76 ± 13 (%) to the superior pharyngeal constrictor compared with the patients reporting ≥2 change in severity (n=9), who had average V55 = 89 ± 13 (%). V55to V60 had the strongest association with dysphagia (AUC = 0.70-0.75). Based on the regression analysis, a 20% risk of toxicity was associated with V55 = 78%, V60 = 40%. The findings at 12 months were similar. Conclusions: After deintensified CRT, the rate of patient-reported xerostomia/dysphagia appears to be associated with the V15 of the combined contralateral salivary glands and V55 to V60 of the superior pharyngeal constrictors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probabilistic evaluation of shallow groundwater resources at a hypothetical carbon sequestration site

Carbon sequestration in geologic reservoirs is an important approach for mitigating greenhouse gases emissions to the atmosphere. This study first develops an integrated Monte Carlo method for simulating CO 2 and brine leakage from carbon sequestration and subsequent geochemical interactions in shallow aquifers. Then, we estimate probability distributions of five risk proxies related to the likelihood and volume of changes in pH, total dissolved solids, and trace concentrations of lead, arsenic, and cadmium for two possible consequence thresholds. The results indicate that shallow groundwater resources may degrade locally around leakage points by reduced pH and increased total dissolved solids (TDS). The volumes of pH and TDS plumes are most sensitive to aquifer porosity, permeability, and CO 2 and brine leakage rates. The estimated plume size of pH change is the largest, while that of cadmium is the smallest among the risk proxies. Plume volume distributions of arsenic and lead are similar to those of TDS. The scientific results from this study provide substantial insight for understanding risks of deep fluids leaking into shallow aquifers, determining the area of review, and designing monitoring networks at carbon sequestration sites.

58 GEOSCIENCES↗

Experimental Tests of Lateral Bedload Transport Induced by a Yawed Submerged Vane Array in Open-Channel Flows

This work proposes the use of an array of yawed porous vanes to control the lateral bedload transport by locally steering bedform migration and maximize the amount of sediments redirected toward a potential sediment extraction system or bypass channel. A laboratory experiment was conducted in a quasifield-scale channel with an array of permeable vanes installed on one side, in live-bed conditions under bedload dominant regime, i.e., negligible suspended load. A baseline experiment without vanes was also performed for comparison. The evolution of migrating bedforms of different scales was tracked in space and time using a high-resolution, state-of-the-art laser scanning device. The bedload transport rate in the streamwise direction was first calculated using bedforms’ geometry and migration velocity, and then spatially distributed over the entire monitored area using a new Eulerian-averaged grid-mapping method. This allowed us to introduce a new methodology to estimate the lateral bedload transport using control volume theory and applying mass conservation. Quantitative assessments of lateral bedload transport along the channel yield consistent results, suggesting that the vanes effectively move sediments laterally as intended. Under the investigated setup, the maximum lateral sediment transport rate ranges from 9% to 18% of the whole domain-averaged streamwise transport rate. The developed methodology also allowed to identify the location where sediment capture could be maximized for the given vane spatial distribution.

42 ENGINEERING↗

Determination of optical conductivity and different optical energy losses for non-crystalline Vanadyl tetra tert-butyl 2,3 Naphthalocyanine thinfilms

Amorphous Vanadyl Tetra Tert Butyl 2, 3 naphthalocyanine thin films (VTTBNc) have been deposited using Physical Vapor Deposition technique. By analyzing the X-ray diffraction, the structure of as deposited films is found to be non-crystalline. Different optical properties of these thin films have been investigated by means of optical absorption and reflection spectra. Various optical constants like band gap energy, E{sub g} the width of band tails of localized states into the gap, E{sub U} and steepness parameter, {beta} gets calculated and the variation of different optical parameters like refractive index, extinction coefficient, dielectric constants, optical conductivity and surface and volume energy losses with photon energy are estimated.

36 MATERIALS SCIENCE↗

Atomic scale observation of phase separation and formation of silicon clusters in Hf higk-{kappa} silicates

Hafnium silicate films were fabricated by RF reactive magnetron sputtering technique. Fine microstructural analyses of the films were performed by means of high-resolution transmission electron microscopy and atom probe tomography. A thermal treatment of as-grown homogeneous films leads to a phase separation process. The formation of SiO{sub 2} and HfO{sub 2} phases as well as pure Si one was revealed. This latter was found to be amorphous Si nanoclusters, distributed uniformly in the film volume. Their mean diameter and density were estimated to be about 2.8 nm and (2.9 {+-} 0.4) x 10{sup 17} Si-ncs/cm{sup 3}, respectively. The mechanism of the decomposition process was proposed. The obtained results pave the way for future microelectronic and photonic applications of Hf-based high-{kappa} dielectrics with embedded Si nanoclusters.

36 MATERIALS SCIENCE↗

Relaxation behavior of oxygen deficient strontium manganite

Conduction behavior of nanocrystalline oxygen deficient ceramic-SrMnO{sub 3–δ}(δ∼0.14) has been studied. The structural analysis of nano-SrMnO{sub 2.86} follows hexagonal unit cell structure with P6{sub 3}/mmc (194) space group belonging to 6/mmm point group with 4H – layered type hexagonal-cubic layers. The system have lattice parameters; a = 5.437(92) Å, c = 9.072(92) Å, c/a∼1.66 (85) with α =90° γ= 120° and cell volume, V= 232.35(18). The relaxation times estimated from complex impedance and modulus relaxation spectrum, show the thermally activated system with corresponding activation energies as 0.66 eV and 0.51 eV The stretching factor ‘β’ from the scaled modulus spectrum shows the poly-dispersive non-Debye nature of the system. The hopping number ‘n’ shows the influence of ionic charge carriers which controls the conduction mechanism of nano-SrMnO{sub 2.86}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics in poly vinyl alcohol (PVA) based hydrogel: Neutron scattering study

Results of quasielastic neutron scattering measurements carried out on Poly Vinyl Alcohol (PVA) based hydrogels are reported here. PVA hydrogels are formed using Borax as a cross-linking agent in D{sub 2}O solvent. This synthetic polymer can be used for obtaining the hydrogels with potential use in the field of biomaterials. The aim of this paper is to study the dynamics of polymer chain in the hydrogel since it is known that polymer mobility influences the kinetics of loading and release of drugs. It is found that the dynamics of hydrogen atoms in the polymer chain could be described by a model where the diffusion of hydrogen atoms is limited within a spherical volume of radius 3.3 Å. Average diffusivity estimated from the behavior of quasielastic width is found to be 1.2 × 10{sup −5} cm{sup 2}/sec.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EVOLUTIONARY STATUS OF BRIGHTEST AND YOUNGEST SOURCE IN THE ORION MOLECULAR CLOUD -3 REGION

The brightest continuum source in the Orion molecular cloud-3 region (OMC-3), MMS 6, was observed with the Very Large Array (VLA), the Nobeyama Millimeter Array (NMA), and the Submillimeter Array (SMA). Our data were supplemented by near- to mid-infrared archival data taken by Spitzer Space Telescope. The compact continuum source, MMS 6-main, was detected with an H{sub 2} mass of 3.0 M {sub sun} with a size of 510 AU. Despite its compact and well-condensed appearance, neither clear CO outflow, radio jet, nor infrared sources (at a wavelength shorter than 8 mum) were detected at MMS 6-main even with the present high angular resolution and high-sensitivity observations. The derived H{sub 2} column density, 2.6 x 10{sup 25} cm{sup -2}, corresponds to a visual extinction of A{sub v} approx 15, 000 mag, and the derived number density is at least two orders of magnitude higher than for the other OMC-2/3 continuum sources. The volume density profile of the source was estimated to have a power-law index of 2 or steeper down to a radius of approx450 AU. The timescale to form a protostar at the center or the timescale elapsed after its formation is estimated to be 830 to 7600 yr. This is much shorter than the typical lifetime of the Class 0/I protostars, which is approx10{sup 4}-10{sup 5} yr, suggesting that MMS 6-main is probably in either the earliest stage of the protostellar core or in the latest stage of the prestellar phase.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional physics and the pressure of hot QCD

We update Monte Carlo simulations of the three-dimensional SU(3)+adjoint Higgs theory, by extrapolating carefully to the infinite volume and continuum limits, in order to estimate the contribution of the infrared modes to the pressure of hot QCD. The sum of infrared contributions beyond the known 4-loop order turns out to be a smooth function, of a reasonable magnitude and specific sign. Unfortunately, adding this function to the known 4-loop terms does not improve the match to four-dimensional lattice data, in spite of the fact that other quantities, such as correlation lengths, spatial string tension, or quark number susceptibilities, work well within the same setup. We outline possible ways to reduce the mismatch.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Primordial Black Holes with QCD Color Charge

We describe a realistic mechanism whereby black holes with significant QCD color charge could have formed during the early Universe. Primordial black holes (PBHs) could make up a significant fraction of the dark matter if they formed well before the QCD confinement transition. Such PBHs would form by absorbing unconfined quarks and gluons and hence could acquire a net color charge. We estimate the number of PBHs per Hubble volume with near-extremal color charge for various scenarios and discuss possible phenomenological implications. Published by the American Physical Society 2024

Physics↗

A Perspective on Data and Privacy for AI in Healthcare [Industrial and Governmental Activities]

As large language models continue to push the bounds of AI model size, they are also being trained on unprecedented volumes of data. While individual hospitals are estimated to produce petabytes of data per year, only a small fraction is currently being used for developing AI models. Additionally, with such data resources available, healthcare is well-positioned to benefit from the current trends in AI. Moreover, the inherently multi-modal and longitudinal nature of clinical data – from omics to imaging to unstructured notes – provides a fertile ground for the development and application of cutting-edge architectures like foundation models.

Gounley, John [Oak Ridge National Laboratory (ORNL↗

TU-A-12A-12: Improved Airway Measurement Accuracy for Low Dose Quantitative CT (qCT) Using Statistical (ASIR), at Reduced DFOV, and High Resolution Kernels in a Phantom and Swine Model

Purpose: Quantitative accuracy of Iodine Hounsfield Unit (HU) in conventional single-kVp scanning is susceptible to beam-hardening effect. Dual-energy CT has unique capabilities of quantification using monochromatic CT images, but this scanning mode requires the availability of the state-of-the-art CT scanner and, therefore, is limited in routine clinical practice. Purpose of this work was to develop a beam-hardening-correction (BHC) for single-kVp CT that can linearize Iodine projections at any nominal energy, apply this approach to study Iodine response with respect to keV, and compare with dual-energy based monochromatic images obtained from material-decomposition using 80kVp and 140kVp. Methods: Tissue characterization phantoms (Gammex Inc.), containing solid-Iodine inserts of different concentrations, were scanned using GE multi-slice CT scanner at 80, 100, 120, and 140 kVp. A model-based BHC algorithm was developed where Iodine was estimated using re-projection of image volume and corrected through an iterative process. In the correction, the re-projected Iodine was linearized using a polynomial mapping between monochromatic path-lengths at various nominal energies (40 to 140 keV) and physically modeled polychromatic path-lengths. The beam-hardening-corrected 80kVp and 140kVp images (linearized approximately at effective energy of the beam) were used for dual-energy material-decomposition in Water-Iodine basis-pair followed by generation of monochromatic images. Characterization of Iodine HU and noise in the images obtained from singlekVp with BHC at various nominal keV, and corresponding dual-energy monochromatic images, was carried out. Results: Iodine HU vs. keV response from single-kVp with BHC and dual-energy monochromatic images were found to be very similar, indicating that single-kVp data may be used to create material specific monochromatic equivalent using modelbased projection linearization. Conclusion: This approach may enable quantification of Iodine contrast enhancement and potential reduction in injected contrast without using dual-energy scanning. However, in general, dual-energy scanning has unique value in material characterization and quantification, and its value cannot be discounted. GE Healthcare Employee.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-601: Equivalence of CyberKnife and TrueBeam STx for Spine Irradiation

Purpose: To evaluate the equivalence of spine SBRT treatment plans created in Eclipse for the TrueBeam STx (Varian Medical System, Palo Alto, CA) compared to plans using CyberKnife and MultiPlan (Accuray, Sunnyvale, CA). Methods: CT data and contours for 23 spine SBRT patients previously treated using CyberKnife (CK) were exported from MultiPlan treatment planning system into Eclipse where they were planned using static IMRT 6MV coplanar beams. Plans were created according to the original prescription dose and fractionation schedule while limiting spinal dose according to the RTOG 0631 protocol and maintaining target coverage comparable to the original CK plans. Plans were evaluated using new conformity index (nCI), homogeneity index (HI), dose-volume histogram data, number of MU, and estimated treatment time. To ensure all Eclipse plans were deliverable, standard clinical IMRT QA was performed. The plan results were matched with their complimentary CK plans for paired statistical analysis. Results: Plans generated in Eclipse demonstrated statistically significant (p<0.01) improvements compared to complimentary CK plans in median values of maximum spinal cord dose (17.39 vs. 18.12 Gy), RTOG spinal cord constraint dose (14.50 vs. 16.93 Gy), nCI (1.28 vs. 1.54), HI (1.13 vs. 1.27), MU (3918 vs. 36416), and estimated treatment time (8 vs. 48 min). All Eclipse generated plans passed our clinically used protocols for IMRT QA. Conclusion: CK spine SBRT replanned utilizing Eclipse for LINAC delivery demonstrated dosimetric advantages. We propose improvements in plan quality metrics reviewed in this study may be attributed to dynamic MLCs that facilitate treatment of complicated geometries as well as posterior beams ideal for centrally located and/or posterior targets afforded by gantry-based RT delivery.

60 APPLIED LIFE SCIENCES↗