Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Autonomous elemental characterization enabled by a low cost robotic platform built upon a generalized software architecture

Despite the rapidly growing applications of robots in industry, the use of robots to automate tasks in scientific laboratories is less prolific due to the lack of generalized methodologies and the high cost of hardware. This paper focuses on the automation of characterization tasks necessary for reducing cost while maintaining generalization and proposes a software architecture for building robotic systems in scientific laboratory environments. A dual-layer (Socket.IO and ROS) action server design is the basic building block, which facilitates the implementation of a web-based front end for user-friendly operation and the use of ROS Behavior Trees for convenient task planning and execution. A robotic platform for automating mineral and material sample characterization is built upon the architecture, with an open-source, low-cost three-axis computer numerical control gantry system serving as the main robot. A handheld laser induced breakdown spectroscopy (LIBS) analyzer is integrated with a 3D printed adapter, enabling (1) automated 2D chemical mapping and (2) autonomous sample measurement (with the support of an RGB-Depth camera). We demonstrate the utility of automated chemical mapping by scanning the surface of a spodumene-bearing pegmatite core sample with a 1071-point dense hyperspectral map acquired at a rate of 1520 bits per second. Furthermore, we showcase the autonomy of the platform in terms of perception, dynamic decision-making, and execution, through a case study of LIBS measurement of multiple mineral samples. The platform enables controlled and autonomous chemical quantification in the laboratory that complements field-based measurements acquired with the same handheld device, linking resource exploration and processing steps in the supply chain for lithium-based battery materials.

Cao, Xuan [Lawrence Berkeley National Laboratory (↗

Feature-based characterization of motion-contaminated calcified plaques in cardiac multidetector CT

In coronary calcium scoring, motion artifacts affecting calcified plaques are commonly characterized using descriptive terms, which incorporate an element of subjectivity in their interpretations. Quantitative indices may improve the objective characterization of these motion artifacts. In this paper, an automated method for generating 12 quantitative indices, i.e., features that characterize the motion artifacts affecting calcified plaques, is presented. This method consists of using the rapid phase-correlated region-of-interest (ROI) tracking algorithm for reconstructing ROI images of calcified plaques automatically from the projection data obtained during a cardiac scan, and applying methods for extracting features from these images. The 12 features include two dynamic, six morphological, and four intensity-based features. The two dynamic features are three-dimensional (3D) velocity and 3D acceleration. The six morphological features include edge-based volume, threshold-based volume, sphericity, irregularity, average margin gradient, and variance of margin gradient. The four intensity-based features are maximum intensity, mean intensity, minimum intensity, and standard deviation of intensity. The 12 features were extracted from 54 reconstructed sets of simulated four-dimensional images from the dynamic NCAT phantom involving six calcified plaques under nine heart rate/multi-sector gating combinations. In order to determine how well the 12 features correlated with a plaque motion index, which was derived from the trajectory of the plaque, partial correlation coefficients adjusted for heart rate, number of gated sectors, and mean feature values of the six plaques were calculated for all 12 features. Features exhibiting stronger correlations (|r| set-membership sign [0.60,1.00]) with the motion index were 3D velocity, maximum intensity, and standard deviation of intensity. Features demonstrating stronger correlations (|r| set-membership sign [0.60,1.00]) with other features mostly involved intensity-based features. Edge-based volume/irregularity and average margin gradient/variance of margin gradient were the only two feature pairs out of 12 with stronger correlations that did not involve intensity-based features. Automatically extracted features of the motion artifacts affecting calcified plaques in cardiac computed tomography images potentially can be used to develop models for predicting image assessability with respect to motion artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A computational implementation and comparison of several intensity modulated proton therapy treatment planning algorithms

The authors present a comparative study of intensity modulated proton therapy (IMPT) treatment planning employing algorithms of three-dimensional (3D) modulation, and 2.5-dimensional (2.5D) modulation, and intensity modulated distal edge tracking (DET) [A. Lomax, Phys. Med. Biol. 44, 185-205 (1999)] applied to the treatment of head-and-neck cancer radiotherapy. These three approaches were also compared with 6 MV photon intensity modulated radiation therapy (IMRT). All algorithms were implemented in the University of Florida Optimized Radiation Therapy system using a finite sized pencil beam dose model and a convex fluence map optimization model. The 3D IMPT and the DET algorithms showed considerable advantages over the photon IMRT in terms of dose conformity and sparing of organs at risk when the beam number was not constrained. The 2.5D algorithm did not show an advantage over the photon IMRT except in the dose reduction to the distant healthy tissues, which is inherent in proton beam delivery. The influences of proton beam number and pencil beam size on the IMPT plan quality were also studied. Out of 24 cases studied, three cases could be adequately planned with one beam and 12 cases could be adequately planned with two beams, but the dose uniformity was often marginally acceptable. Adding one or two more beams in each case dramatically improved the dose uniformity. The finite pencil beam size had more influence on the plan quality of the 2.5D and DET algorithms than that of the 3D IMPT. To obtain a satisfactory plan quality, a 0.5 cm pencil beam size was required for the 3D IMPT and a 0.3 cm size was required for the 2.5D and the DET algorithms. Delivery of the IMPT plans produced in this study would require a proton beam spot scanning technique that has yet to be developed clinically.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-156: Preclinical Inverstigation of Dynamic Tumor Tracking Using Vero SBRT Linear Accelerator: Motion Phantom Dosimetry Study

Purpose: Following the ‘end-to-end testing’ paradigm of Dynamic Target Tracking option in our Image-Guided dedicated SBRT VeroTM linac, we verify the capability of the system to deliver planned dose to moving targets in the heterogeneous thorax phantom (CIRSTM). The system includes gimbaled C-band linac head, robotic 6 degree of freedom couch and a tumor tracking method based on predictive modeling of target position using fluoroscopically tracked implanted markers and optically tracked infrared reflecting external markers. Methods: 4DCT scan of the motion phantom with the VisicoilTM implanted marker in the close vicinity of the target was acquired, the ‘exhale’=most prevalent phase was used for planning (iPlan by BrainLabTM). Typical 3D conformal SBRT treatment plans aimed to deliver 6-8Gy/fx to two types of targets: a)solid water-equivalent target 3cm in diameter; b)single VisicoilTM marker inserted within lung equivalent material. The planning GTV/CTV-to-PTV margins were 2mm, the block margins were 3 mm. The dose calculated by MonteCarlo algorithm with 1% variance using option Dose-to-water was compared to the ion chamber (CC01 by IBA Dosimetry) measurements in case (a) and GafchromicTM EBT3 film measurements in case (b). During delivery, the target 6 motion patterns available as a standard on CIRSTM motion phantom were investigated: in case (a), the target was moving along the designated sine or cosine4 3D trajectory; in case (b), the inserted marker was moving sinusoidally in 1D. Results: The ion chamber measurements have shown the agreement with the planned dose within 1% under all the studied motion conditions. The film measurements show 98.1% agreement with the planar calculated dose (gamma criteria: 3%/3mm). Conclusion: We successfully verified the capability of the SBRT VeroTM linac to perform real-time tumor tracking and accurate dose delivery to the target, based on predictive modeling of the correlation between implanted marker motion and external surrogate of breathing motion.

60 APPLIED LIFE SCIENCES↗

Structural variability in Cu(I) and Ag(I) coordination polymers with a flexible dithione ligand: Synthesis, crystal structure, microbiological and theoretical studies

Two new compounds namely [Cu(SCN)(µ-L)]{sub n} (1) and ([Ag (µ{sub 2}-L)](ClO{sub 4})){sub n} (2) have been synthesized at room temperature by one-pot reactions between the 1,1-(1,4-butanediyl)bis(1,3-dihydro-3-methyl-1H-imidazole- 2-thione) (L) and appropriate copper(I) and silver(I) salts. These polymers have been characterized by single crystal X-ray diffraction, XRPD, TGA, elemental analysis, infrared spectroscopy, antibacterial activity and scanning probe microscopy studies. In the crystal structure of 1, copper atoms have a distorted trigonal planar geometry with a CuS{sub 2}N coordination environment. Each of the ligands in the structure of 1 acting as a bidentate S-bridging ligand to form a 1D chain structure. Additionally, the adjacent 1D chains are interconnected by the intermolecular C-H…S interactions to create a 2D network structure. In contrast to 1, in the cationic 3D structure of 2 each of the silver atoms exhibits an AgS{sub 4} tetrahedral geometry with 4-membered Ag{sub 2}S{sub 2} rings. In the structure of 2, the flexible ligand adopts two different conformations; gauche-anti-gauche and anti-anti-anti. The antibacterial studies of these polymers showed that polymer 2 is more potent antibacterial agent than 1. Scanning probe microscopy (SPM) study of the treated bacteria was carried out to investigate the structural changes cause by the interactions between the polymers and target bacteria. Theoretical study of polymer 1 investigated by the DFT calculations indicates that observed transitions at 266 nm and 302 nm in the UV–vis spectrum could be attributed to the π→π* and MLCT transitions, respectively. - Graphical abstract: Two new Cu(I) and Ag(I) coordination polymers have been have been synthesized by one-pot reactions. Copper complex has a 2D non-covalent structure, but silver compound is a 3D coordination compound. These compounds have effective antibacterial activity. - Highlights: • Cu(I) and Ag(I) based coordination polymers have different network structures. • Ag(I) polymer has more antibacterial activity than Cu(I) polymer. • DFT calculations of Cu(I) polymer has been investigated. • Cu(I) and Ag(I) polymers can destroy the structure of chromosomal and plasmid DNA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Height control of self-assembled quantum dots by strain engineering during capping

Strain engineering during the capping of III-V quantum dots has been explored as a means to control the height of strained self-assembled quantum dots. Results of Kinetic Monte Carlo simulations are confronted with cross-sectional Scanning Tunnel Microscopy (STM) measurements performed on InAs quantum dots grown by molecular beam epitaxy. We studied InAs quantum dots that are capped by In{sub x}Ga{sub (1−x)}As layers of different indium compositions. Both from our realistic 3D kinetic Monte Carlo simulations and the X-STM measurements on real samples, a trend in the height of the capped quantum dot is found as a function of the lattice mismatch between the quantum dot material and the capping layer. Results obtained on additional material combinations show a generic role of the elastic energy in the control of the quantum dot morphology by strain engineering during capping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Light-Dependent Impedance Spectra and Transient Photoconductivity in a Ruddlesden–Popper 2D Lead–Halide Perovskite Revealed by Electrical Scanned Probe Microscopy and Accompanying Theory

Electric force microscopy was used to record the light-dependent impedance spectrum and the probe transient photoconductivity of a film of butylammonium lead iodide, BA 2 PbI 4 , a 2D Ruddlesden–Popper perovskite semiconductor. The impedance spectrum of BA 2 PbI 4 showed modest changes as the illumination intensity was varied up to 1400 mW cm –2 , in contrast with the comparatively dramatic changes seen for 3D lead–halide perovskites under similar conditions. BA 2 PbI 4 ’s light-induced conductivity had a rise time and decay time of ~100 μs, 10 4 slower than expected from direct electron–hole recombination yet 10 5 faster than the conductivity-recovery times recently observed in 3D lead–halide perovskites and attributed to the relaxation of photogenerated vacancies. What sample properties are probed by electric force microscope measurements remains an open question. A Lagrangian-mechanics treatment of the electric force microscope experiment was recently introduced by Dwyer, Harrell, and Marohn which enabled the calculation of steady-state electric force microscope signals in terms of a complex sample impedance. Here this impedance treatment of the tip–sample interaction is extended, through the introduction of a time-dependent transfer function, to include time-resolved electrical scanned probe measurements. Here, it is shown that the signal in a phase-kick electric force microscope experiment, and therefore also the signal in a time-resolved electrostatic force microscope experiment, can be written explicitly in terms of the sample’s time-dependent resistance (i.e., conductivity).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-H-207A-03: CT Hounsfield Unit Accuracy: Effect of Beam Hardening On Phantom and Clinical Whole-Body CT Images

Purpose: To assess the effect of beam hardening on measured CT HU values. Methods: An anthropomorphic knee phantom was scanned with the CT component of a GE Discovery 690 PET/CT scanner (120kVp, 300mAs, 40?0.625mm collimation, pitch=0.984, FOV=500mm, matrix=512?512) with four different scan setups, each of which induces different degrees of beam hardening by introducing additional attenuation media into the field of view. Homogeneous voxels representing “soft tissue” and “bone” were segmented by HU thresholding followed by a 3D morphological erosion operation which removes the non-homogenous voxels located on the interface of thresholded tissue mask. HU values of segmented “soft tissue” and “bone” were compared.Additionally, whole-body CT data with coverage from the skull apex to the end of toes were retrospectively retrieved from seven PET/CT exams to evaluate the effect of beam hardening in vivo. Homogeneous bone voxels were segmented with the same method previously described. Total In-Slice Attenuation (TISA) for each CT slice, defined as the summation of HU values over all voxels within a CT slice, was calculated for all slices of the seven whole-body CT datasets and evaluated against the mean HU values of homogeneous bone voxels within that slice. Results: HU values measured from the phantom showed that while “soft tissue” HU values were unaffected, added attenuation within the FOV caused noticeable decreases in the measured HU values of “bone” voxels. A linear relationship was observed between bone HU and TISA for slices of the torso and legs, but not of the skull. Conclusion: Beam hardening effect is not an issue of concern for voxels with HU in the soft tissue range, but should not be neglected for bone voxels. A linear relationship exists between bone HU and the associated TISA in non-skull CT slices, which can be exploited to develop a correction strategy.

60 APPLIED LIFE SCIENCES↗

Ion-beam-induced bending of freestanding amorphous nanowires: The importance of the substrate material and charging

Ion-beam irradiation offers great flexibility and controllability in the construction of freestanding nanostructures with multiple advanced functionalities. Here, we present and discuss the bending of free-standing nanowires, against, towards, and ultimately parallel to a flux of directional ion irradiation. Bending components both along and perpendicular to the incident ion beam were observed, and the bending behavior was found to depend both on the ion beam scanning strategy and on the conductivity of the supporting substrate. This behavior is explained by an ion-irradiation-related electrostatic interaction. Our findings suggest the prospect of exploiting this technique to engineer 3D nanostructures for advanced applications.

36 MATERIALS SCIENCE↗

Note: Design and development of an integrated three-dimensional scanner for atomic force microscopy

A compact scanning head for the Atomic Force Microscope (AFM) greatly enhances the portability of AFM and facilitates easy integration with other tools. This paper reports the design and development of a three-dimensional (3D) scanner integrated into an AFM micro-probe. The scanner is realized by means of a novel design for the AFM probe along with a magnetic actuation system. The integrated scanner, the actuation system, and their associated mechanical mounts are fabricated and evaluated. The experimentally calibrated actuation ranges are shown to be over 1 μm along all the three axes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections

Purpose: Implanted markers are commonly used in radiotherapy for x-ray based target localization. The projected marker position in a series of cone-beam CT (CBCT) projections can be used to estimate the three dimensional (3D) target trajectory during the CBCT acquisition. This has important applications in tumor motion management such as motion inclusive, gating, and tumor tracking strategies. However, for irregularly shaped markers, reliable segmentation is challenged by large variations in the marker shape with projection angle. The purpose of this study was to develop a semiautomated method for robust and reliable segmentation of arbitrarily shaped radiopaque markers in CBCT projections. Methods: The segmentation method involved the following three steps: (1) Threshold based segmentation of the marker in three to six selected projections with large angular separation, good marker contrast, and uniform background; (2) construction of a 3D marker model by coalignment and backprojection of the threshold-based segmentations; and (3) construction of marker templates at all imaging angles by projection of the 3D model and use of these templates for template-based segmentation. The versatility of the segmentation method was demonstrated by segmentation of the following structures in the projections from two clinical CBCT scans: (1) Three linear fiducial markers (Visicoil) implanted in or near a lung tumor and (2) an artificial cardiac valve in a lung cancer patient. Results: Automatic marker segmentation was obtained in more than 99.9% of the cases. The segmentation failed in a few cases where the marker was either close to a structure of similar appearance or hidden behind a dense structure (data cable). Conclusions: A robust template-based method for segmentation of arbitrarily shaped radiopaque markers in CBCT projections was developed.

60 APPLIED LIFE SCIENCES↗

Critical assessment of intramodality 3D ultrasound imaging for prostate IGRT compared to fiducial markers

Purpose: A quantitative 3D intramodality ultrasound (US) imaging system was verified for daily in-room prostate localization, and compared to prostate localization based on implanted fiducial markers (FMs).Methods: Thirteen prostate patients underwent multiple US scans during treatment. A total of 376 US-scans and 817 matches were used to determine the intra- and interoperator variability. Additionally, eight other patients underwent daily prostate localization using both US and electronic portal imaging (EPI) with FMs resulting in 244 combined US-EPI scans. Scanning was performed with minimal probe pressure and a correction for the speed of sound aberration was performed. Uncertainties of both US and FM methods were assessed. User variability of the US method was assessed.Results: The overall US user variability is 2.6 mm. The mean differences between US and FM are: 2.5 {+-} 4.0 mm (LR), 0.6 {+-} 4.9 mm (SI), and -2.3 {+-} 3.6 mm (AP). The intramodality character of this US system mitigates potential errors due to transducer pressure and speed of sound aberrations.Conclusions: The overall accuracy of US (3.0 mm) is comparable to our FM workflow (2.2 mm). Since neither US nor FM can be considered a gold standard no conclusions can be drawn on the superiority of either method. Because US imaging captures the prostate itself instead of surrogates no invasive procedure is required. It requires more effort to standardize US imaging than FM detection. Since US imaging does not involve a radiation burden, US prostate imaging offers an alternative for FM EPI positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical instability at moving keyhole tip generates porosity in laser melting

Laser powder bed fusion is a dominant metal 3D printing technology. However, porosity defects remain a challenge for fatigue-sensitive applications. Some porosity is associated with deep and narrow vapor depressions called keyholes, which occur under high-power, low–scan speed laser melting conditions. High-speed x-ray imaging enables operando observation of the detailed formation process of pores in Ti-6Al-4V caused by a critical instability at the keyhole tip. We found that the boundary of the keyhole porosity regime in power-velocity space is sharp and smooth, varying only slightly between the bare plate and powder bed. The critical keyhole instability generates acoustic waves in the melt pool that provide additional yet vital driving force for the pores near the keyhole tip to move away from the keyhole and become trapped as defects.

47 OTHER INSTRUMENTATION↗

A Theoretical Insight into the Catalytic Effect of a Mixed-Metal Oxide at the Nanometer Level: The Case of the Highly Active metal/CeOx/TiO2 (110) Catalysts

The structural and electronic properties of CeO{sub x} species supported on the rutile TiO{sub 2}(110) surface have been examined by means of periodic density-functional calculations that use a generalized gradient approximation functional including a Hubbard-like type correction. Deposition of Ce atoms leads in a first step to Ce{sup 3+} ions bound to the surface through bridge and in-plane oxygen atoms, the released electrons occupying the Ti 3d empty orbitals. Further addition of Ce and molecular oxygen gives place to Ce{sub 2}O{sub 3} dimers diagonally arranged on the surface, in agreement with the spots observed in the scanning tunnel microscope images. The formation process of CeO{sub x} nanoparticles (NPs) on the TiO{sub 2} surface is highly exothermic and our calculations show that the redox properties of the Ce(III)-Ce(IV) couple are significantly altered when it is supported on TiO{sub 2}. In particular the reactivity against CO/O{sub 2} indicates that on the surface the presence of Ce(III) is favored over Ce(IV) species. Our results also indicate that the CeO{sub x}/TiO{sub 2} interface should be seen like a real mixed-metal oxide rather than a supported NP of ceria. Finally, in the context of the high catalytic activity of the M/CeO{sub x}/TiO{sub 2} (M = Au,Cu,Pt) systems in the water-gas shift reaction, we have examined the dissociation of water on the CeO{sub x}/TiO{sub 2} surface and estimated a barrier as small as 0.04 eV, i.e. {approx}8 times smaller than that computed for a TiO{sub 2} oxygen vacancy. This result agrees with the experimental superior catalytic activity of the M/CeO{sub x}/TiO{sub 2} systems over M/TiO{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation and visible light photocatalytic activity of Bi{sub 2}O{sub 3}/Bi{sub 2}WO{sub 6} heterojunction photocatalysts

The Bi{sub 2}O{sub 3}/Bi{sub 2}WO{sub 6} heterojunction photocatalysts were prepared by a two-step solvothermal process using Bi(NO{sub 3}){sub 3}-ethylene glycol solution as Bi source. The catalysts were characterized by X-ray diffraction, scanning and transmission electron microscopy, X-ray photoelectron spectroscopy, and UV-vis diffuse reflection spectroscopy. The heterostructure catalysts are composed of Bi{sub 2}O{sub 3} nanoparticles as modifier and 3D Bi{sub 2}WO{sub 6} microspheres as substrate. Bi{sub 2}O{sub 3} nanoparticles with diameters of about 10-15 nm are tightly grown on the lateral surface of the Bi{sub 2}WO{sub 6} microspheres. The hierarchical Bi{sub 2}O{sub 3}/Bi{sub 2}WO{sub 6} microspheres exhibit higher photocatalytic activity than the single phase Bi{sub 2}WO{sub 6} or Bi{sub 2}O{sub 3} for the degradation of rhodamine B under visible light illumination ({lambda}>420 nm). The enhancement of the photocatalytic activity of the Bi{sub 2}O{sub 3}/Bi{sub 2}WO{sub 6} heterojunction catalysts can be ascribed to their improved light absorption property and the reduced recombination of the photoexcited electrons and holes during the photocatalytic reaction. The effect of loading amount of Bi{sub 2}O{sub 3} on the catalytic performance of the heterojunction catalysts was also investigated and the optimal content of Bi{sub 2}O{sub 3} is 3 wt%. The Bi{sub 2}O{sub 3}/Bi{sub 2}WO{sub 6} heterojunction photocatalysts are essentially stable during the photocatalytic process. - Graphical abstract: The Bi{sub 2}O{sub 3}/Bi{sub 2}WO{sub 6} heterojunction catalysts were constructured with improved photocatalytic activity, which can be ascribed to their improved light absorption property and the reduced recombination rate between photoexcited electrons and holes. Highlights: > Bi{sub 2}O{sub 3}/Bi{sub 2}WO{sub 6} heterojunction photocatalysts. > Effective separation of photoexcited electrons and holes. > High visible light photocatalytic activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Modeling of Hydraulic Properties of a Sheared Single Rock Fracture

Flow through a single mechanically sheared Marcellus shale fracture was investigated computationally and experimentally. To provide a better understanding of the variation of hydraulic and geometrical characteristics of a fracture subjected to shearing, coupled shear flow tests on the fracture for four shearing displacement steps under constant normal stress were performed. At the end of each shearing step, computed tomography (CT) scans with resolution 26.8 μm were obtained and the corresponding fracture geometries were evaluated. The CT images were used to generate full aperture maps of the fracture configuration. In addition, average aperture maps were also created by averaging the full-resolution data over 10 × 10 pixels, smoothing out fine structural details. Computational modeling of water flow through the fractures at different shearing steps was performed using a modified local cubic law approach and the 3D full Navier–Stokes equations with the use of the ANSYS-Fluent software. Both the average aperture maps and full maps were used in these simulations. The experimental pressure drops of the fracture at shearing step 1, which has very small apertures, poorly matched the numerical results, quite likely because the fracture structure was inadequately captured by the scanning resolution. Shearing typically increased the aperture height of the fracture, whose features were then better captured by the CT scan. Good agreement between the experimental data and the numerical results of the full map for shearing step 2 was observed. The simulations were performed for both full and average aperture maps, and the effects of scan resolution and surface roughness on the accuracy of the results were studied. The modified local cubic law and full Navier–Stokes simulations of the averaged map fracture were found to be in good agreement. It was conjectured that this was because the nonlinear losses were insignificant for the smoothed out averaged map fracture. Similar comparisons with those of the full map showed agreement in trends, but there were some quantitative differences. The averaged fracture map simulations also predicted lower pressure drops compared to the full map, particularly for high flow rates. These differences were due to the fine-scale geometrical complexity (surface roughness) of fracture geometry that affects the fluid flow in the fracture. In conclusion, an improved cubic law model was also proposed, and its accuracy was verified by comparing its predictions with those of the Navier–Stokes simulations.

58 GEOSCIENCES↗

SU-F-T-181: Proton Therapy Tissue-Equivalence of 3D Printed Materials

Purpose: This work investigated the proton tissue-equivalence of various 3D printed materials. Methods: Three 3D printers were used to create 5 cm cubic phantoms made of different plastics with varying percentages of infill. White resin, polylactic acid (PLA), and NinjaFlex plastics were used. The infills ranged from 15% to 100%. Each phantom was scanned with a CT scanner to obtain the HU value. The relative linear stopping power (RLSP) was then determined using a multi-layer ion chamber in a 200 MeV proton beam. The RLSP was measured both parallel and perpendicular to the print direction for each material. Results: The HU values of the materials ranged from lung-equivalent (−820 HU σ160) when using a low infill, to soft-tissue-equivalent 159 (σ12). The RLSP of the materials depended on the orientation of the beam relative to the print direction. When the proton beam was parallel to the print direction, the RLSP was generally higher than the RLSP in the perpendicular orientation, by up to 45%. This difference was smaller (less than 6%) for the materials with 100% infill. For low infill cubes irradiated parallel to the print direction, the SOBP curve showed extreme degradation of the beam in the distal region. The materials with 15–25% infill had wide-ranging agreement with a clinical HU-RLSP conversion curve, with some measurements falling within 1% of the curve and others deviating up to 45%. The materials with 100% infill all fell within 7% of the curve. Conclusion: While some materials tested fall within 1% of a clinical HU-RLSP curve, caution should be taken when using 3D printed materials with proton therapy, as the orientation of the beam relative to the print direction can result in a large change in RLSP. Further investigation is needed to measure how the infill pattern affects the material RLSP. This work was supported by PHS grant CA180803.

60 APPLIED LIFE SCIENCES↗