Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Roadmap on nanoscale magnetic resonance imaging

Abstract The field of nanoscale magnetic resonance imaging (NanoMRI) was started 30 years ago. It was motivated by the desire to image single molecules and molecular assemblies, such as proteins and virus particles, with near-atomic spatial resolution and on a length scale of 100 nm. Over the years, the NanoMRI field has also expanded to include the goal of useful high-resolution nuclear magnetic resonance (NMR) spectroscopy of molecules under ambient conditions, including samples up to the micron-scale. The realization of these goals requires the development of spin detection techniques that are many orders of magnitude more sensitive than conventional NMR and MRI, capable of detecting and controlling nanoscale ensembles of spins. Over the years, a number of different technical approaches to NanoMRI have emerged, each possessing a distinct set of capabilities for basic and applied areas of science. The goal of this roadmap article is to report the current state of the art in NanoMRI technologies, outline the areas where they are poised to have impact, identify the challenges that lie ahead, and propose methods to meet these challenges. This roadmap also shows how developments in NanoMRI techniques can lead to breakthroughs in emerging quantum science and technology applications.

Budakian, Raffi↗

Asymmetric nanoparticle oxidation observed in-situ by the evolution of diffraction contrast

Abstract The use of transmission electron microscopy (TEM) to observe real-time structural and compositional changes has proven to be a valuable tool for understanding the dynamic behavior of nanomaterials. However, identifying the nanoparticles of interest typically require an obvious change in position, size, or structure, as compositional changes may not be noticeable during the experiment. Oxidation or reduction can often result in subtle volume changes only, so elucidating mechanisms in real-time requires atomic-scale resolution or in-situ electron energy loss spectroscopy, which may not be widely accessible. Here, by monitoring the evolution of diffraction contrast, we can observe both structural and compositional changes in iron oxide nanoparticles, specifically the oxidation from a wüstite-magnetite (FeO@Fe 3 O 4 ) core – shell nanoparticle to single crystalline magnetite, Fe 3 O 4 nanoparticle. The in-situ TEM images reveal a distinctive light and dark contrast known as the ‘Ashby-Brown contrast’, which is a result of coherent strain across the core – shell interface. As the nanoparticles fully oxidize to Fe 3 O 4 , the diffraction contrast evolves and then disappears completely, which is then confirmed by modeling and simulation of TEM images. This represents a new, simplified approach to tracking the oxidation or reduction mechanisms of nanoparticles using in-situ TEM experiments.

36 MATERIALS SCIENCE↗

Site-resolved oxygen K-edge ELNES of the layered double perovskite La{sub 2}CuSnO{sub 6}

Electron energy-loss spectroscopy (EELS) combined with scanning transmission electron microscopy (STEM) allows for the investigation of the local electronic structure with atomic column resolution, owing to the development of spherical aberration correctors. In the present research, we report B-site-resolved oxygen K-edge energy-loss near-edge structure (ELNES) measured from a double perovskite La{sub 2}CuSnO{sub 6} (LCSO) using STEM-EELS. There are two kinds of BO{sub 6} (B=Sn and Cu) octahedrons, arranged in layers in the LCSO crystal. The observed site-resolved oxygen K-edge ELNES showed different features reflecting local chemical bonding around the Sn and Cu ions. In particular, it is demonstrated that the local electronic structure in the distorted CuO{sub 6} octahedron caused by the Jahn-Teller effect can be detected by site-resolved ELNES.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High signal-to-noise ratio differential conductance spectroscopy

The scanning tunneling microscope (STM) has enabled manipulation and interrogation of surfaces with atomic-scale resolution. Electronic information about a surface is obtained by combining the imaging capability of the STM with scanning tunneling spectroscopy, i.e., measurement of current-voltage (I/V) characteristics of the surface. We propose a change in the STM feedback loop that enables capturing a higher quality dI/dV image. A high frequency dither voltage is added to the bias voltage of the sample, and the fundamental frequency component of the resulting current is demodulated. The in-phase component of this signal is then plotted along with the X and Y position data, constructing the dI/dV image. Here, we show that by incorporating notch filters in the STM feedback loop, we may utilize a high-amplitude dither voltage to significantly improve the quality of the obtained dI/dV image.

42 ENGINEERING↗

Analysis of furnace contamination on superconducting radio frequency niobium using secondary-ion mass spectrometry

Detection of surface contamination on niobium materials used in superconducting radio frequency (SRF) applications is difficult due to quantitative sensitivity and near-atomic depth resolution needed. Inspection of samples known to have experienced surface contamination was found to have inconsistent nitride coverage after high-temperature nitrogen gas exposure (“doping”). Here we compare contaminating species found on samples treated in several different vacuum furnaces, both “exposed” directly in the chamber and “protected” by containment shielding from evaporative sources with “furnace caps.” Typically, furnace caps are used to impede contamination from reaching the interior surface of cavities during the high-temperature vacuum bake that immediately precedes exposure to nitrogen gas. Although, to date, little is known about the effectiveness of these caps, SIMS results showed that they were effective in limiting contamination arising from the furnace environment. Inspection of sample surfaces by SEM showed a lack of nitrides present on contaminated specimens. TEM with energy dispersive spectroscopy performed on these samples revealed that a carbon-rich layer now existed, indicating that a relatively high contaminant load prevents the nucleation and growth of surface nitrides, while thus inhibiting interstitial nitrogen uptake. Except in extreme cases, subsequent removal of the top several micrometers of the surface via electropolishing appears to effectively eliminate any strong influence on the subsequent SRF cavity performance. With the absence of furnace cleaning, carbon contamination was found to be nearly 10× higher for protected nitrogen-doped and electropolished samples, with minimal metallic contamination detected for both processes. SIMS analysis was also performed to compare the cleanliness of samples fully prepared by such nitrogen “doping” with those prepared by a related process, involving the dissolution of niobium surface oxide and diffusion of oxygen into the surface. This oxygen doping or alloying process offers attractive advantages.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Retinal isomerization in bacteriorhodopsin captured by a femtosecond x-ray laser

Ultrafast isomerization of retinal is the primary step in photoresponsive biological functions including vision in humans and ion transport across bacterial membranes. In this study, we used an x-ray laser to study the subpicosecond structural dynamics of retinal isomerization in the light-driven proton pump bacteriorhodopsin. A series of structural snapshots with near-atomic spatial resolution and temporal resolution in the femtosecond regime show how the excited all-trans retinal samples conformational states within the protein binding pocket before passing through a twisted geometry and emerging in the 13-cis conformation. In conclusion, our findings suggest ultrafast collective motions of aspartic acid residues and functional water molecules in the proximity of the retinal Schiff base as a key facet of this stereoselective and efficient photochemical reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method to determine the strain and the nucleation sites of stacked nano-objects

We determine the compositional distribution with atomic column resolution in a horizontal nanowire from the analysis of aberration-corrected high resolution Z-contrast images. The strain field in a layer capping the analysed nanowire is determined by anisotropic elastic theory from the resulting compositional map. The reported method allows preferential nucleation sites for epitaxial nano-objects to be predicted with high spatial resolution, as required for accurate tuning of desired optical properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray probes for in situ studies of interfaces.

Surfaces and buried interfaces play critical roles in many environmental, catalytic, and tribological processes and in a wide variety of applications, including microelectronics and optoelectronics. Interfacial structure and composition are closely coupled to their surroundings, and probes that yield information about materials in situ are essential to obtain a thorough understanding of interface functions and properties. The highly brilliant, hard x-rays available from synchrotron light sources can easily penetrate through gas or liquid environments, or even solid thin-film overlayers, and enable real-time monitoring of the evolving chemistry and structure of the interface with atomic-scale resolution. Here we review the in situ study of interfaces by a variety of synchrotron x-ray scattering techniques and provide several examples of their application in electrochemical processes and thin-film island growth. We also discuss recent advances in analytical techniques and x-ray optics that are facilitating the in situ study of surfaces and buried interfaces with direct imaging.

36 MATERIALS SCIENCE↗

Open Reproducible Electron Microscopy Data Analysis

Electron microscopy (EM) is a cornerstone technique in the materials and biological sciences capable of imaging structures at nano- to atomic-scale resolution. Advances in technologies mean that one acquires datasets at increasing data rates and sizes. These advancements present enormous opportunities for researchers to understand complex systems. However, processing the resulting large-scale, complex data in a reproducible and shareable way is a real challenge for researchers. The building, managing, and maintaining complex workflows in a reproducible manner requires extensive knowledge in several areas outside the researchers’ core skill sets, such as software engineering, data science, and high-performance computing (HPC). Our work demonstrates an innovative approach to solving these problems, enabling reproducible EM data analysis through container encapsulated pipelines. Using modern container technologies, we encapsulate processing elements and connect them using shared memory. We expose user-friendly, advanced algorithms and tools to allow end users to utilize without expert programming skills. The platform enables reproducible, scalable, shareable pipelines for the analysis and visualization of EM data. Focusing on interoperability, we leverage the DOE and other agencies’ existing investments to provide a powerful software platform for EM data analysis.

Harris, Christopher↗

Time-resolved probing of laser-induced nanostructuring processes in liquids

Laser synthesis and processing of colloids (LSPC) in liquids has gained widespread applications in producing nanomaterials of different classes of solids. While the technical processes in different cases of ablation, fragmentation or colloidal fusion may look macroscopically different in each application, the underlying fundamental mechanisms are always the same cascade of laser interaction with matter, non-thermal or thermal energy deposition, phase transitions, and the subsequent structure formation processes. Disentangling these mechanisms represents a veritable challenge, as ultrafast and structurally sensitive experimental methods are required. This review presents a discussion of how state-of-the-art experimental protocols using ultrafast lasers and sensitive structural probes, such as electrons or X-rays are able to address this challenge. In particular, it is possible to investigate LSPC on single objects using single probe pulses and avoid accumulation effects in a heterogeneous sample. The presented results capture structure formation with femtosecond and atomic scale resolution. Ultrafast time-resolved probing approaches are key to revealing the transient states and pathways that govern material transformation in LSPC.

X-ray scattering↗

A scheme for handling arrays in data-flow systems

An examination of the effects of atomicity (higher resolution) on the performance of array processors (data-flow computers) is presented. Data-flow principles are reviewed, noting the reliance on parallel processing using functional languages to specify sequencing of the operations. Techniques are described for eliminating the necessity of copying whole arrays between processing steps, thereby reducing the number of store cycles. The method involves setting whole columns to specific values rather than individual elements. The individual column values can be processed in parallel, i.e., a locally optimized condition exists. A drawback of the system is the need for more low level arguments, to identify the appropriate processing sequences, and high system complexity.

Gaudiot, J.-L.↗

Laboratory Astrophysics: Enabling Scientific Discovery and Understanding

NASA's Science Strategic Roadmap for Universe Exploration lays out a series of science objectives on a grand scale and discusses the various missions, over a wide range of wavelengths, which will enable discovery. Astronomical spectroscopy is arguably the most powerful tool we have for exploring the Universe. Experimental and theoretical studies in Laboratory Astrophysics convert "hard-won data into scientific understanding". However, the development of instruments with increasingly high spectroscopic resolution demands atomic and molecular data of unprecedented accuracy and completeness. How to meet these needs, in a time of severe budgetary constraints, poses a significant challenge both to NASA, the astronomical observers and model-builders, and the laboratory astrophysics community. I will discuss these issues, together with some recent examples of productive astronomy/lab astro collaborations.

Kirby, K.↗

Column-by-column compositional mapping by Z-contrast imaging

A phenomenological method is developed to determine the composition of materials, with atomic column resolution, by analysis of integrated intensities of aberration-corrected Z-contrast scanning transmission electron microscopy images. The method is exemplified for InAsxP1!x alloys using epitaxial thin films with calibrated compositions as standards. Using this approach we have determined the composition of the two-dimensional wetting layer formed between self-assembled InAs quantum wires on InP(0 01) substrates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Unlocking the Secrets of Brain Signals (4K)

Scientists have for the first time determined, at atomic-scale resolution, the 3-D structure of a protein complex that provides the ultrafast trigger for chemicals messages sent between nerve cells in our brains. The discovery, which provides a new understanding of the molecular machinery driving brain function, builds on decades of research at Stanford University, the Stanford School of Medicine and SLAC National Accelerator Laboratory was made possible by SLAC’s Linac Coherent Light Source, an ultrabright X-ray laser.

59 BASIC BIOLOGICAL SCIENCES↗

LCLS-II: The Next Leap for X-Ray Science

This movie introduces LCLS-II, a future light source at SLAC. It will generate over 8,000 times more light pulses per second than today’s most powerful X-ray laser, LCLS, and produce an almost continuous X-ray beam that on average will be 10,000 times brighter. These unrivaled capabilities will help researchers address a number of grand challenges in science by capturing detailed snapshots of rapid processes that are beyond the reach of other light sources.

43 PARTICLE ACCELERATORS↗

Real-time sparse-sampled Ptychographic imaging through deep neural networks

Ptychography has rapidly grown in the fields of X-ray and electron imaging for its unprecedented ability to achieve nano or atomic scale resolution while simultaneously retrieving chemical or magnetic information from a sample. A ptychographic reconstruction is achieved by means of solving a complex inverse problem that imposes constraints both on the acquisition and on the analysis of the data, which typically precludes real-time imaging due to computational cost involved in solving this inverse problem. In this work we propose PtychoNN, a novel approach to solve the ptychography reconstruction problem based on deep convolutional neural networks. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. The presented results demonstrate how PtychoNN can effectively be used on experimental data, being able to generate high quality reconstructions of a sample up to hundreds of times faster than state-of-the-art ptychography reconstruction solutions once trained. By surpassing the typical constraints of iterative model-based methods, we can significantly relax the data acquisition sampling conditions and produce equally satisfactory reconstructions. Besides drastically accelerating acquisition and analysis, this capability can enable new imaging scenarios that were not possible before, in cases of dose sensitive, dynamic and extremely voluminous samples.

Cherukara, Mathew J↗

Studies of x-ray localization and thickness dependence in atomic-scale elemental mapping by STEM energy-dispersive x-ray spectroscopy using single-frame scanning method

The delocalization of x-ray signals limits the spatial resolution in atomic-scale elemental mapping by scanning transmission electron microscopy (STEM) using energy-dispersive x-ray spectroscopy (EDS). In this study, using a SrTiO 3 [001] single crystal, we show that the x-ray localization to atomic columns is strongly dependent on crystal thickness, and a thin crystal is critical for improving the spatial resolution in atomic-scale EDS mapping. A single-frame scanning technique is used in this study instead of the multiple-frame technique to avoid peak broadening due to tracking error. The strong thickness dependence is realized by measuring the full width at half maxima (FWHM) as well as the peak-to-valley (P/V) ratio of the EDS profiles for Ti K and Sr K+L, obtained at several crystal thicknesses. A FWHM of about 0.16 nm and a P/V ratio of greater than 7.0 are obtained for Ti K for a crystal thickness of less than 20 nm. In conclusion, with increasing crystal thickness, the FWHM and P/V ratio increases and decreases, respectively, indicating the advantage of using a thin crystal for high-resolution EDS mapping.

36 MATERIALS SCIENCE↗

Photoelectron angular distributions from autoionizing 4s{sup 1}4p{sup 6}6p{sup 1} states in atomic krypton probed with femtosecond time resolution

Photoelectron angular distributions (PADs) are obtained for a pair of 4s{sup 1}4p{sup 6}6p{sup 1} (a singlet and a triplet) autoionizing states in atomic krypton. A high-order harmonic pulse is used to excite the pair of states and a time-delayed 801 nm ionization pulse probes the PADs to the final 4s{sup 1}4p{sup 6} continuum with femtosecond time resolution. The ejected electrons are detected with velocity map imaging to retrieve the time-resolved photoelectron spectrum and PADs. The PAD for the triplet state is inherently separable by virtue of its longer autoionization lifetime. Measuring the total signal over time allows for the PADs to be extracted for both the singlet state and the triplet state. Anisotropy parameters for the triplet state are measured to be {beta}{sub 2}= 0.55 {+-} 0.17 and {beta}{sub 4}=-0.01 {+-} 0.10, while the singlet state yields {beta}{sub 2}= 2.19 {+-} 0.18 and {beta}{sub 4}= 1.84 {+-} 0.14. For the singlet state, the ratio of radial transition dipole matrix elements, X, of outgoing S to D partial waves and total phase shift difference between these waves, {Delta}, are determined to be X= 0.56 {+-} 0.08 and {Delta}= 2.19 {+-} 0.11 rad. The continuum quantum defect difference between the S and D electron partial waves is determined to be -0.15 {+-} 0.03 for the singlet state. Based on previous analyses, the triplet state is expected to have anisotropy parameters independent of electron kinetic energy and equal to {beta}{sub 2}= 5/7 and {beta}{sub 4}=-12/7. Deviations from the predicted values are thought to be a result of state mixing by spin-orbit and configuration interactions in the intermediate and final states; theoretical calculations are required to quantify these effects.

74 ATOMIC AND MOLECULAR PHYSICS↗