Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

35-Day Evolution of the Her X-1 Pulse Profile: Evidence for a Resolved Inner Disk Occultation of the Neutron Star

Ginga and RXTE observations have allowed an unprecedented view of the recurrent systematic pulse shape changes associated with the 35-day cycle of Her X-1, a phenomena currently unique among the known accretion-powered pulsars. We present observations of the pulse shape evolution. An explanation for the pulse evolution in terms of a freely precessing neutron star is reviewed and shown to have several major difficulties in explaining the observed pulse evolution pattern. Instead, we propose a phenomenlogical model for the pulse evolution based upon an occultation of the pulse emitting region by the tilted, inner edge of a precessing accretion disk. The systematic and repeating pulse shape changes require a resolved occultation of the pulse emission region. The observed pulse profile motivates the need for a pulsar beam consisting of a composite coaxial pencil and fan beam but the observed evolution pattern requires the fan beam to be focused around the neutron star and beamed in the antipodal direction. The spectral hardness of the pencil beam component suggests an origin at the magnetic polar cap, with the relatively softer fan beam emission produced by backscattering from within the accretion column, qualitatively consistent with several theoretical models for X-ray emission from the accretion column of an accreting neutron star.

Scott, D. Matthew↗

The 35 Day Evolution of the Hercules X-1 Pulse Profile: Evidence for a Resolved Inner Disk Occultation of the Neutron Star

Ginga and Rossi X-Ray Timing Explorer observations have allowed an unprecedented view of the recurrent systematic pulse shape changes associated with the 35 day cycle of Hercules X-1, a phenomenon currently unique among the known accretion-powered pulsars. We present observations of the pulse shape evolution. An explanation for the pulse evolution in terms of a freely precessing neutron star is reviewed and shown to have several major difficulties in explaining the observed pulse evolution pattern. Instead, we propose a phenomenological model for the pulse evolution based on an occultation of the pulse-emitting region by the tilted, inner edge of a precessing accretion disk. The systematic and repeating pulse shape changes require a resolved occultation of the pulse emission region. The observed pulse profile motivates the need for a pulsar beam consisting of a composite coaxial pencil and fan beam, but the observed evolution pattern requires the fan beam to be focused around the neutron star and beamed in the antipodal direction. The spectral hardness of the pencil beam component suggests an origin at the magnetic polar cap, with the relatively softer fan beam emission produced by backscattering from within the accretion column, qualitatively consistent with several theoretical models for X-ray emission from the accretion column of an accreting neutron star.

Scott, D. Matthew↗

Crater Flux Transfer Events: Highroad to the X Line?

We examine Cluster observations of a so-called magnetosphere crater FTE, employing data from five instruments (FGM, CIS, EDI, EFW, and WHISPER), some at the highest resolution. The aim of doing this is to deepen our understanding of the reconnection nature of these events by applying recent advances in the theory of collisionless reconnection and in detailed observational work. Our data support the hypothesis of a stratified structure with regions which we show to be spatial structures. We support the bulge-like topology of the core region (R3) made up of plasma jetting transverse to reconnected field lines. We document encounters with a magnetic separatrix as a thin layer embedded in the region (R2) just outside the bulge, where the speed of the protons flowing approximately parallel to the field maximizes: (1) short (fraction of a sec) bursts of enhanced electric field strengths (up to approximately 30 mV/m) and (2) electrons flowing against the field toward the X line at approximately the same time as the bursts of intense electric fields. R2 also contains a density decrease concomitant with an enhanced magnetic field strength. At its interface with the core region, R3, electric field activity ceases abruptly. The accelerated plasma flow profile has a catenary shape consisting of beams parallel to the field in R2 close to the R2/R3 boundary and slower jets moving across the magnetic field within the bulge region. We detail commonalities our observations of crater FTEs have with reconnection structures in other scenarios. We suggest that in view of these properties and their frequency of occurrence, crater FTEs are ideal places to study processes at the separatrices, key regions in magnetic reconnection. This is a good preparation for the MMS mission.

Farrugia, C. J.↗

Assessment Study of Small Space Debris Removal by Laser Satellites

Space debris in Earth orbit poses significant danger to satellites, humans in space, and future space exploration activities. In particular, the increasing number of unidentifiable objects, smaller than 10 cm, presents a serious hazard. Numerous technologies have been studied for removing unwanted objects in space. Our approach uses a short wavelength laser stationed in orbit to vaporize these small objects. This paper discusses the power requirements for space debris removal using lasers. A short wavelength laser pumped directly or indirectly by solar energy can scan, identify, position, and illuminate the target, which will then be vaporized or slow down the orbital speed of debris by laser detonation until it re-enters the atmosphere. The laser-induced plasma plume has a dispersive motion of approximately 105 m/sec with a Lambertian profile in the direction of the incoming beam [1-2]. The resulting fast ejecting jet plume of vaporized material should prevent matter recombination and condensation. If it allows any condensation of vaporized material, the size of condensed material will be no more than a nanoscale level [3]. Lasers for this purpose can be indirectly pumped by power from an array of solar cells or directly pumped by the solar spectrum [4]. The energy required for vaporization and ionization of a 10 cm cube (~ 2700 gm) of aluminum is 87,160 kJ. To remove this amount of aluminum in 3 minutes requires a continuous laser beam power of at least 5.38 MW under the consideration of 9% laser absorption by aluminum [5] and 5% laser pumping efficiency. The power needed for pumping 5.38 MW laser is approximately 108 MW, which can be obtained from a large solar array with 40% efficiency solar cells and a minimal area of 450 meters by 450 meters. This solar array would collect approximately 108 MW. The power required for system operation and maneuvering can be obtained by increasing solar panel size. This feasibility assessment covers roughly the power requirement, laser system, and a potential operational scenario.

Choi, Sang H.↗

Characterization of 4H <000-1> Silicon Carbide Films Grown by Solvent-Laser Heated Floating Zone

Commercially available bulk silicon carbide (SiC) has a high number (>2000/sq cm) of screw dislocations (SD) that have been linked to degradation of high-field power device electrical performance properties. Researchers at the NASA Glenn Research Center have proposed a method to mass-produce significantly higher quality bulk SiC. In order for this bulk growth method to become reality, growth of long single crystal SiC fibers must first be achieved. Therefore, a new growth method, Solvent-Laser Heated Floating Zone (Solvent-LHFZ), has been implemented. While some of the initial Solvent-LHFZ results have recently been reported, this paper focuses on further characterization of grown crystals and their growth fronts. To this end, secondary ion mass spectroscopy (SIMS) depth profiles, cross section analysis by focused ion beam (FIB) milling and mechanical polishing, and orientation and structural characterization by x-ray transmission Laue diffraction patterns and x-ray topography were used. Results paint a picture of a chaotic growth front, with Fe incorporation dependant on C concentration.

Woodworth, Andrew, A↗

A Flat-Panel 8x8 Sequentially Rotated Wideband Microstrip Patch Phased Array Antenna for K/Ka-band 6U CubeSat Communications Applications

Flat-panel electronically-scanned phased arrays have recently become a mainstream technology in the areas of radar and satellite applications, particularly due to their low profile and not having to steer the beams mechanically, both of which helps in realizing a lightweight phased array solution that also occupies a smaller volume. Typically for satellite applications, circularly polarized element radiators are often employed in order to deal with the signal fading problem. In this project, the main objective was to design a flat-panel phased array solution for 6U CubeSat communication applications. As for the required specifications, the array should have two operating bands: 22.55–23.55 GHz and 25.5–27.5 GHz, which span part of the K and Ka bands. For both these bands, the panel should be able to radiate dual circular polarization, in both transmit and receive modes, and with a stable gain performance. Since the individual bands are very closely spaced, it was realized that a single wideband design would be a better solution than a closely spaced dual-band design. Thus, a stacked microstrip patch configuration was selected for the element radiator design, which is known to be wideband. Now, it is rather difficult to realize both wide impedance and axial ratio bandwidths simultaneously, and at high frequencies, without complicating the element stacked patch design.. As a result, a sequential rotation technique wasemployed to significantly improves the axial ratio bandwidth and circular polarization purity of an array, all the while improving the pattern symmetry (P. S. Hall, “Application of Sequential Feeding to Wide Bandwidth, Circularly Polarised Microstrip Patch Arrays,” IEE Proc. H (Microw., Antennas Propag.), vol. 136, no. 5, pp. 390–398, Oct. 1989). The designed element radiator is a circularly-polarized probe-fed stacked patch antenna, which has a 10-dB matching bandwidth of 22.3– 30 GHz, with only a 5.14% axial ratio bandwidth around the center frequency of the required band, i.e., ~25 GHz. However, the resulting array demonstrates a very low axial ratio (≪ 3 dB) over the entire bandwidth, due to the application of the sequential rotation technique. The 8×8 array was able to scan up to ±51° and ±40° at frequencies 23.05 GHz and 26.5 GHz (center frequencies of the lower and upper bands), respectively, while maintaining a ≤ 3 dB axial ratio and a ≤ 3 dB gain drop from the corresponding peak broadside value at both the principle and the diagonal radiation planes. The designed layout for the 8×8 phased array prototype is shown in Fig. 1, which is currently undergoing fabrication and RF assembly. The antenna will be tested in the far-field anechoic chambers of the Antenna and Microwave Laboratory (AML) at San Diego State University and at NASA Glenn Research Center (GRC).

5G↗

Comparison of Doppler back-scattering and charge exchange measurements of E × B plasma rotation in the DIII-D tokamak under varying torque conditions

Measurements of the E × B toroidal angular velocity, $\omega_{E \times B}\,=\,E_\mathrm{r}/RB_\theta$ ($E_\mathrm{r}$ is the radial electric field, B θ is the poloidal magnetic field), are made using the Doppler back-scattering (DBS) and charge-exchange recombination (CER) spectroscopy diagnostics. DBS uses the Doppler shift of wavenumber-resolved density fluctuations while CER uses the Doppler shift of impurity emission lines to independently measure plasma parameters for calculating the local radial electric field. DBS and CER profiles of $\omega_{E \times B}$ as a function of normalized toroidal flux (ρ) are compared at various levels of neutral beam applied torque on the plasma. Under standard neoclassical theory $\omega_{E\times B}$ is a flux surface quantity, making it appropriate to compare across diagnostics. DBS and CER generally show good agreement when comparing $\omega_{E \times B}$ profiles at different levels of neutral beam injection-applied torque. Furthermore, the DBS values have close to the same precision as CER values when averaged over a similar time-scale and effects, such as prompt-torque are considered. DBS is able to observe the rapid ($\lt$10 ms) modification of the $E_\mathrm{r}$ profile by the diagnostic neutral beam 'blips'. This modification is most pronounced when the blip applies a large relative change in torque on the plasma. Overall, these results could have implications on transport analysis and suggests using DBS and CER in conjunction to constrain values of the E × B-shear (sometimes called $\gamma_{E \times B}$).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of MHD instabilities on neutral beam current drive

One of the primary tools foreseen for heating, current drive (CD) and q-profile control in future fusion reactors such as ITER and a Fusion Nuclear Science Facility is the neutral beam injection (NBI). However, fast ions from NBI may also provide the drive for energetic particle-driven instabilities (e.g. Alfvénic modes (AEs)), which in turn redistribute fast ions in both space and energy, thus hampering the control capabilities and overall efficiency of NB-driven current. Based on experiments on the NSTX tokamak (M. Ono et al 2000 Nucl. Fusion 40 557), the effects of AEs and other low-frequency magneto-hydrodynamic instabilities on NB-CD efficiency are investigated. When looking at the new fast ion transport model, which accounts for particle transport in phase space as required for resonant AE perturbations, is utilized to obtain consistent simulations of NB-CD through the tokamak transport code TRANSP. It is found that instabilities do indeed reduce the NB-driven current density over most of the plasma radius by up to ~50%. Moreover, the details of the current profile evolution are sensitive to the specific model used to mimic the interaction between NB ions and instabilities. Finally, implications for fast ion transport modeling in integrated tokamak simulations are briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-127: Application of TG-119 for Evaluation of Proton Spot Scanning Based Planning and Treatment Delivery

Purpose: The clinical test cases presented in AAPM TG-119 are used to evaluate the accuracy of treatment planning and delivery through spot scanning proton beams. Methods: An IBA spot scanning delivery system has been commissioned to be used with the RayStation treatment planning system. Various test cases provided in TG-119 were used for planning and delivery verification. The CT dataset and structures as provided by TG-119 were imported into a mock patient. The plans were optimized using the multi field optimization (MFO) to achieve the desired goals. The planner was given the flexibility to achieve the given dose-volume goals by creating appropriate objectives and constraints. Beams were delivered to a phantom and measurements were performed at multiple depths using the MatrixxPT detector array. The analyses were performed on beam by beam basis and quantified using the gamma index. A tolerance of 3%/3 mm in 2D was used for gamma index analysis along with dose threshold of 10%. Results: The clinical goals for targets and critical structures were met or improved for all cases except the C-Shape target with difficult constraints. The minimum gamma index using the 3%/3mm as a criterion is 93.3% for one of the planes measured for C-Shape target. Using 2%/2mm as a criterion, the minimum gamma index drops to 70%. Only Prostate target has all the planes above >90% pass using the 2%/2mm criterion. Conclusion: The overall accuracy of the treatment planning and delivery is deemed clinically acceptable. The test cases with highly modulated beams can have steep gradients in the dose profiles that can reduce the gamma index pass rate. Gamma analysis based on 3D data may be needed for routine use of 2%/2mm criterion. In addition, improvements in modelling of spot profiles in dose engine may be required for further improving the gamma index pass rate.

60 APPLIED LIFE SCIENCES↗

Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting the rotation profile in ITER

Determining the toroidal rotation for future tokamaks like ITER is a challenging and important problem. By combining empirical scalings for the intrinsic rotation at the top of the pedestal with the expected neutral beam torque and modeling of momentum transport, the toroidal rotation profile for ITER is predicted with TGYRO using TGLF (SAT0 and SAT1). On axis rotation exceeds 20 krad s –1 and the E x B shear is significant enough to reduce turbulent transport and significantly increase confinement and fusion power when comparing to cases that ignore the effect of rotation. Here, the prediction of the rotation at the top of the pedestal is made with increased confidence due to experiments and modeling in DIII-D that have determined the importance of fast-ion and neutral particle transport effects on intrinsic rotation at this location. In particular, the effect of neutral particles on momentum transport in the pedestal region is found to be insignificant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A broadband gyrotron backward-wave oscillator with tapered interaction structure and magnetic field

The gyro-monotron and gyrotron backward-wave oscillator (gyro-BWO) are the two oscillator versions of gyrotrons. While serving different functions, they are also radically different in the RF field formation mechanisms. The gyro-monotron RF field profile is essentially fixed by the resonant interaction structure, while the gyro-BWO possesses an extra degree of freedom in that the axial RF field profile is self-determined by the beam-wave interaction in a waveguide structure. The present study examines ways to utilize the latter feature for bandwidth broadening with a tapered magnetic field, while also employing a tapered waveguide to enhance the interaction efficiency. We begin with a mode competition analysis, which suggests the theoretical feasibility of broadband frequency tuning in single-mode operation. It is then shown in theory that, by controlling the RF field profile with an up- or down-tapered magnetic field, the gyro-BWO is capable of efficient operation with a much improved tunable bandwidth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parameterization of photon beam dosimetry for a linear accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modeled data, (3) the quality assurance process of a linear accelerator’s (Linac) beam characteristics, (4) the establishment of a standard data set for comparison with other data, etcetera. Parameterization of the photon beam dosimetry creates a data set that is portable and easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon beam dosimetric quantities, including percentage depth doses (PDDs), profiles, and total scatter output factors (S{sub cp}). Methods: S{sub cp}, PDDs, and profiles for different field sizes, depths, and energies were measured for a Linac using a cylindrical 3D water scanning system. All data were smoothed for the analysis and profile data were also centered, symmetrized, and geometrically scaled. The S{sub cp} data were analyzed using an exponential function. The inverse square factor was removed from the PDD data before modeling and the data were subsequently analyzed using exponential functions. For profile modeling, one halfside of the profile was divided into three regions described by exponential, sigmoid, and Gaussian equations. All of the analytical functions are field size, energy, depth, and, in the case of profiles, scan direction specific. The model’s parameters were determined using the minimal amount of measured data necessary. The model’s accuracy was evaluated via the calculation of absolute differences between the measured (processed) and calculated data in low gradient regions and distance-to-agreement analysis in high gradient regions. Finally, the results of dosimetric quantities obtained by the fitted models for a different machine were also assessed. Results: All of the differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 and 0.5 mm, respectively. The differences in the low gradient regions were 0.20% ± 0.20% (<1% for all) and 0.50% ± 0.35% (<1% for all) for PDDs and profiles, respectively. For S{sub cp} data, all of the absolute differences were less than 0.5%. Conclusions: This novel analytical model with minimum measurement requirements was proved to accurately calculate PDDs, profiles, and S{sub cp} for different field sizes, depths, and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields

Purpose: Modern radiotherapy modalities often use small or nonstandard fields to ensure highly localized and precise dose delivery, challenging conventional clinical dosimetry protocols. The emergence of preclinical spatially fractionated synchrotron radiotherapies with high dose-rate, sub-millimetric parallel kilovoltage x-ray beams, has pushed clinical dosimetry to its limit. A commercially available synthetic single crystal diamond detector designed for small field dosimetry has been characterized to assess its potential as a dosimeter for synchrotron microbeam and minibeam radiotherapy. Methods: Experiments were carried out using a synthetic diamond detector on the imaging and medical beamline (IMBL) at the Australian Synchrotron. The energy dependence of the detector was characterized by cross-referencing with a calibrated ionization chamber in monoenergetic beams in the energy range 30–120 keV. The dose-rate dependence was measured in the range 1–700 Gy/s. Dosimetric quantities were measured in filtered white beams, with a weighted mean energy of 95 keV, in broadbeam and spatially fractionated geometries, and compared to reference dosimeters. Results: The detector exhibits an energy dependence; however, beam quality correction factors (k{sub Q}) have been measured for energies in the range 30–120 keV. The k{sub Q} factor for the weighted mean energy of the IMBL radiotherapy spectrum, 95 keV, is 1.05 ± 0.09. The detector response is independent of dose-rate in the range 1–700 Gy/s. The percentage depth dose curves measured by the diamond detector were compared to ionization chambers and agreed to within 2%. Profile measurements of microbeam and minibeam arrays were performed. The beams are well resolved and the full width at halfmaximum agrees with the nominal width of the beams. The peak to valley dose ratio (PVDR) calculated from the profiles at various depths in water agrees within experimental error with PVDR calculations from Gafchromic film data. Conclusions: The synthetic diamond detector is now well characterized and will be used to develop an experimental dosimetry protocol for spatially fractionated synchrotron radiotherapy.

60 APPLIED LIFE SCIENCES↗

Doping To Reduce Base Resistances Of Bipolar Transistors

Modified doping profile proposed to reduce base resistance of bipolar transistors. A p/p+ base-doping profile reduces base resistance without reducing current gain. Proposed low/high base-doping profile realized by such low-temperature deposition techniques as molecular-beam epitaxy, ultra-high-vacuum chemical-vapor deposition, and limited-reaction epitaxy. Produces desired doping profiles without excessive diffusion of dopant.

Lin, True-Lon↗

Impact of Photon Recycling, Grain Boundaries, and Nonlinear Recombination on Energy Transport in Semiconductors

Energy carrier transport and recombination in semiconductors can be directly monitored with optical microscopy, revealing key insights into fundamental photophysics and informs efficient optoelectronic device design. Oftentimes, energy transport is measured by monitoring a time-resolved expanding carrier profile after optical excitation under a focused laser beam. Although this approach has gained widespread adoption, the presence of competing dynamic processes, such as diffusion and photon recycling, has made it difficult to accurately extract and understand important semiconductor properties. Here, we develop and apply a new framework for modeling energy transport in both excitonic and free carrier semiconductors. Here, we demonstrate that processes such as nonlinear recombination and photon recycling can have a significant impact on the apparent energy carrier profiles, especially for excitonic materials with short radiative lifetimes. Additionally, we find that film microstructure can lead to unique transport profiles that strongly depends on material boundary behavior and the difference between feature size and diffusion length. Here, these findings provide a deeper understanding of energy transport in semiconducting materials and provide new strategies for the design and optimization of electronic and optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient laser-driven proton acceleration from a petawatt contrast-enhanced second harmonic mixed-glass laser system

Efficient laser-driven plasma acceleration of ion beams requires precision control of the target–plasma profile, which is crucial to optimize the laser energy transfer. Along the laser propagation direction, this can be achieved by tailoring the temporal structure of the laser pulse. We show for the first time that frequency-doubling of a short pulse (hundreds-femtosecond range) petawatt-class mixed-glass laser system, which results in temporal intensity contrast enhancement, enables surface and volumetric laser–energy coupling, and the acceleration of proton beams from few-nanometer-thick foil targets. Experimentally, maximum ion energies and laser-to-proton energy conversion efficiencies were found to be both maximized at optimum laser and target conditions manifested when the normalized target density nearly equalizes the normalized laser vector potential, which is in agreement with theory and simulations. These signatures are recognized as a unique indication of the interaction between ultra-intense laser pulses with high temporal intensity contrast and ultra-thin nanometer-scale targets. Transverse modulations of accelerated proton beams in the form of bubble- and ring-like structures measured in the thinnest targets provide additional evidence of volumetric laser-driven particle acceleration regimes and transitional features in ultra-thin foil targets specific to laser–plasma interactions characterized by a high temporal intensity contrast. These results open avenues in the generation of high contrast laser pulses from short-pulse-femtosecond petawatt mixed-glass laser systems and demonstrate the feasibility of this technique for applications requiring high laser intensity contrast with high efficiency.

Physics↗

Lidar measurements of polar stratospheric clouds during the 1989 airborne Arctic stratospheric expedition

The Airborne Arctic Stratospheric Expedition (AASE) was conducted during January to February 1989 from the Sola Air Station, Norway. As part of this expedition, the NASA Langley Research Center's multiwavelength airborne lidar system was flown on the NASA Ames Research Center's DC-8 aircraft to measure ozone (O3) and aerosol profiles in the region of the polar vortex. The lidar system simultaneously transmitted laser beams at 1064, 603, 311, and 301.5 nm to measure atmospheric scattering, polarization and O3 profiles. Long range flights were made between Stavanger, Norway, and the North Pole, and between 40 deg W and 20 deg E meridians. Eleven flights were made, each flight lasting an average of 10 hours covering about 8000 km. Atmospheric scattering ratios, aerosol polarizations, and aerosol scattering ratio wavelength dependences were derived from the lidar measurements to altitudes above 27 km. The details of the aerosol scattering properties of lidar observations in the IR, VIS, and UV regions are presented along with correlations with the national meteorological Center's temperature profiles.

Ismail, Syed↗