Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

E1 and E2 cross sections of the {sup 12}C({alpha},{gamma}{sub 0}){sup 16}O reaction using pulsed {alpha} beams

We measured the {gamma}-ray angular distribution from {sup 12}C({alpha},{gamma}{sub 0}){sup 16}O to the ground state of {sup 16}O using a pulsed {alpha} beam at E{sub eff}=1.6 and 1.4 MeV. True events of {sup 12}C({alpha},{gamma}{sub 0}){sup 16}O were discriminated from background events with a time-of-flight method because of neutrons from {sup 13}C({alpha},n){sup 16}O. The obtained {gamma}-ray spectrum with anti-Compton NaI(Tl) spectrometers showed a characteristic line shape from {sup 12}C({alpha},{gamma}{sub 0}){sup 16}O: the Doppler broadening and energy loss of {alpha} particles in {sup 12}C targets. A Rutherford backscattering spectrum of {alpha} particles from enriched {sup 12}C targets was measured during beam irradiation to obtain the target thickness and incident {alpha}-beam intensities. The astrophysical S factors for E1 and E2,S{sub E1}({gamma}{sub 0}:E{sub eff}) and S{sub E2}({gamma}{sub 0}:E{sub eff}), derived from the present cross sections are in excellent agreement with the values derived by R-matrix calculation of the {beta}-delayed {alpha} spectrum of {sup 16}N, and by using the asymptotic normalization constant in the R-matrix fit.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of anisotropic suprathermal ion distributions using multidirectional measurements of escaping neutral atom fluxes

A feasible approach in obtaining experimental data on the angular dependence of the ion distribution function in a fusion plasma is to perform angle-resolved measurements of kinetic energy spectra of escaping neutral atoms. A general calculation scheme has been developed and realized as a FORTRAN code that has a predictive force to simulate the experimentally measurable anisotropic distributions and random samples of escaping neutral atom kinetic energies for any given angle-dependent ion distribution law, electron density, and temperature profiles, plasma composition, magnetic surface structure, and experiment geometry on any toroidal plasma device with magnetic confinement. As a particular application of the method to a specific experiment, measured signals for all 20 channels of the angle-resolved multisightline neutral particle analyzer on Large Helical Device have been numerically simulated for certain predefined model fast ion distribution functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Finite element analysis of the impact of beam heating mode in molten salt corrosion experiments employing simultaneous ion irradiation

Finite element analysis was used to investigate the temperature and stress profiles that develop in 316L stainless steel membranes being irradiated using different proton beam conditions in contact with a molten salt environment. It was shown that in addition to a nonuniform irradiation profile, a focused 2 MeV proton beam leads to very strong temperature and stress gradients in the membrane, introducing highly localized driving forces that complicate and even compromise the integrity and reliability of the experimental results of corrosion studies. Here, the use of a focused beam in corrosion studies can create experimental artifacts that may misrepresent the true corrosion behavior. In contrast, the use of a rastered beam is shown to distribute the protons and resulting radiation damage uniformly across the membrane face, and more importantly, results in temperature and stress profiles that are not only very uniform but are of much lower magnitude. The use of a rastered beam during molten salt corrosion experiments is therefore recommended to achieve uniform damage rates, thereby reducing both gradients and magnitudes of the temperature and stress distributions.

43 - PARTICLE ACCELERATORS↗

Poster — Thur Eve — 14: Improving Tissue Segmentation for Monte Carlo Dose Calculation using DECT

Purpose: To improve Monte Carlo dose calculation accuracy through a new tissue segmentation technique with dual energy CT (DECT). Methods: Electron density (ED) and effective atomic number (EAN) can be extracted directly from DECT data with a stoichiometric calibration method. Images are acquired with Monte Carlo CT projections using the user code egs-cbct and reconstructed using an FDK backprojection algorithm. Calibration is performed using projections of a numerical RMI phantom. A weighted parameter algorithm then uses both EAN and ED to assign materials to voxels from DECT simulated images. This new method is compared to a standard tissue characterization from single energy CT (SECT) data using a segmented calibrated Hounsfield unit (HU) to ED curve. Both methods are compared to the reference numerical head phantom. Monte Carlo simulations on uniform phantoms of different tissues using dosxyz-nrc show discrepancies in depth-dose distributions. Results: Both SECT and DECT segmentation methods show similar performance assigning soft tissues. Performance is however improved with DECT in regions with higher density, such as bones, where it assigns materials correctly 8% more often than segmentation with SECT, considering the same set of tissues and simulated clinical CT images, i.e. including noise and reconstruction artifacts. Furthermore, Monte Carlo results indicate that kV photon beam depth-dose distributions can double between two tissues of density higher than muscle. Conclusions: A direct acquisition of ED and the added information of EAN with DECT data improves tissue segmentation and increases the accuracy of Monte Carlo dose calculation in kV photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

A Distributed Simulation-to-Flight Framework to Support Investigating Trust/Trustworthiness in Multi-Agent Systems

As autonomous systems continue to grow both in use and complexity, the necessity for robust and extensible simulation-to-flight methods is paramount for establishing an effective architecture for autonomous systems. A fundamental objective of the ATTRACTOR (Autonomy Teaming and TRAjectories for Complex Trusted Operational Reliability) project was to design and develop a distributed mixed-reality simulation environment to begin establishing a basis for certification of autonomous systems via research into trust and trustworthiness. In this paper, we present an autonomous systems architecture and development framework paired with a persistent distributed modeling and simulation environment for test and evaluation of autonomous systems. The Autonomous Entity Operations Network (AEON) framework enables autonomous system development with an easily extensible collection of libraries and plug-n-play nodes facilitated by the Data Distribution Service (DDS) communication protocol standard. The Baseline Environment for Autonomous Modeling (BEAM) simulation environment is a distributed mixed-reality Unity™-based environment built around the same DDS communication paradigm allowing for easy integration with AEON-based autonomous applications. They were designed under ATTRACTOR in order to measure and establish trustworthiness and trust in single- and multi-agent human-machine systems whether these machines are fixed-wing general aviation, rotary-wing Unmanned Aerial Vehicles (UAVs), ground rovers, or even spacecraft. Together AEON and BEAM enable sim-to-flight with minimal configuration changes. By using AEON and BEAM, source code that runs in simulation ports directly to hardware and has successfully flown in the lab and in the National Airspace System (NAS) at NASA LaRC many times over the lifetime of ATTRACTOR.

Benjamin N Kelley↗

A Distributed Simulation-to-Flight Framework to Support Investigating Trust/Trustworthiness in Multi-Agent Systems

As autonomous systems continue to grow both in use and complexity, the necessity for robust and extensible simulation-to-flight methods is paramount for establishing an effective architecture for autonomous systems. A fundamental objective of the ATTRACTOR (Autonomy Teaming and TRAjectories for Complex Trusted Operational Reliability) project was to design and develop a distributed mixed-reality simulation environment to begin establishing a basis for certification of autonomous systems via research into trust and trustworthiness. In this paper, we present an autonomous systems architecture and development framework paired with a persistent distributed modeling and simulation environment for test and evaluation of autonomous systems. The Autonomous Entity Operations Network (AEON) framework enables autonomous system development with an easily extensible collection of libraries and plug-n-play nodes facilitated by the Data Distribution Service (DDS) communication protocol standard. The Baseline Environment for Autonomous Modeling (BEAM) simulation environment is a distributed mixed-reality Unity™-based environment built around the same DDS communication paradigm allowing for easy integration with AEON-based autonomous applications. They were designed under ATTRACTOR in order to measure and establish trustworthiness and trust in single- and multi-agent human-machine systems whether these machines are fixed-wing general aviation, rotary-wing Unmanned Aerial Vehicles (UAVs), ground rovers, or even spacecraft. Together AEON and BEAM enable sim-to-flight with minimal configuration changes. By using AEON and BEAM, source code that runs in simulation ports directly to hardware and has successfully flown in the lab and in the National Airspace System (NAS) at NASA LaRC many times over the lifetime of ATTRACTOR.

Benjamin N Kelley↗

Alpha Resonances in {sup 13}C Excited by the {sup 9}Be ({sup 6}Li,d) Reaction

The {sup 9}Be({sup 6}Li,d){sup 13}C reaction was used to investigate alpha resonant states in {sup 13}C up to 13 MeV of excitation. The reaction was measured at a bombarding energy of 25.5 MeV employing the Sao Paulo Pelletron-Enge-Spectrograph facility and the nuclear emulsion detection technique. The resolution of 50 keV allowed for the separation of the resonant contributions to the known 7/2{sup -} at 10.753 MeV and (5/2{sup -}) at 10.818 MeV {sup 13}C states. The alpha resonance seen at the (3alpha+n) threshold was not previously reported. The experimental angular distributions are presented in comparison with DWBA predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam Propagation Through Atmospheric Turbulence Using an Altitude-Dependent Structure Profile with Non-Uniformly Distributed Phase Screens

Modeling the effects of atmospheric turbulence on optical beam propagation is a key element in the design and analysis of free-space optical communication systems. Numerical wave optics simulations provide a particularly useful technique for understanding the degradation of the optical field in the receiver plane when the analytical theory is insufficient for characterizing the atmospheric channel. Motivated by such an application, we use a split-step method modeling the turbulence along the propagation path as a series of thin random phase screens with modified von Karman refractive index statistics using the Hufnagel-Valley turbulence profile to determine the effective structure constant for each screen. In this work, we employ a space-to-ground case study to examine the irradiance and phase statistics for both uniformly and non-uniformly spaced screens along the propagation path and compare to analytical results. We find that better agreement with the analytical theory is obtained using a non-uniform spacing with the effective structure constant for each screen chosen to minimize its contribution to the scintillation in the receiver plane. We evaluate this method as a flexible alternative to other standard layered models used in astronomical imaging applications.

Chahine, Yousef K.↗

Investigation of {sup 88}Sr in the reaction Sr(n, n'{gamma})

With the aid of a beam of fast reactor neutrons, the gamma-ray spectrum and angular distributions of gamma rays with respect to the neutron-beam axis are measured in the reaction Sr(n, n'{gamma}) along with the lifetimes of {sup 88}Sr levels. Values of the multipole-mixture parameter {delta} are found for gamma transitions between levels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generation of Terawatt Attosecond Pulses from Relativistic Transition Radiation

When a femtosecond duration and hundreds of kiloampere peak current electron beam traverses the vacuum and high-density plasma interface, a new process, that we call here relativistic transition radiation (RTR), generates an intense ~ 100 as pulse containing ~ 1 terawatt power of coherent vacuum ultraviolet (VUV) radiation accompanied by several smaller femtosecond duration satellite pulses. This pulse inherits the radial polarization of the incident beam field and has a ring intensity distribution. This RTR is emitted when the beam density is comparable to the plasma density and the spot size much larger than the plasma skin depth. Physically, it arises from the return current or backward relativistic motion of electrons starting just inside the plasma that Doppler up shifts the emitted photons. The number of RTR pulses is determined by the number of groups of plasma electrons that originate at different depths within the first plasma wake period and emit coherently before phase mixing.

43 PARTICLE ACCELERATORS↗

SU-E-T-215: Comparison of VMAT-SABR Treatment Plans with Flattened Filter (FF) Beam and Flattening Filter-Free (FFF) Beam for Localized Prostate Cancer

Purpose: The purpose of this study is to access VMAT-SABR plan using flattening filter (FF) and flattening filter-free (FFF) beam, and compare the verification results for all pretreatment plans. Methods: SABR plans for 20 prostate patients were optimized in the Eclipse treatment planning system. A prescription dose was 42.7 Gy/7 fractions. Four SABR plans for each patient were calculated using Acuros XB algorithm with both FF and FFF beams of 6- and 10-MV. The dose-volume histograms (DVH) and technical parameters were recorded and compared. A pretreatment verification was performed and the gamma analysis was used to quantify the agreement between calculations and measurements. Results: For each patient, the DVHs are closely similar for plans of four different beams. There are small differences showed in dose distributions and corresponding DVHs when comparing the each plan related to the same patient. Sparing on bladder and rectum was slightly better on plans with 10-MV FF and FFF than with 6-MV FF and FFF, but this difference was negligible. However, there was no significance in the other OARs. The mean agreement of 3%/3mm criteria was higher than 97% in all plans. The mean MUs and deliver time employed was 1701±101 and 3.02±0.17 min for 6-MV FF, 1870±116 and 1.69±0.08 min for 6-MV FFF, 1471±86 and 2.68±0.14 min for 10-MV FF, and 1619±101 and 0.98±0.04 min for 10-MV FFF, respectively. Conclusion: Dose distributions on prostate SABR plans using FFF beams were similar to those generated by FF beams. However, the use of FFF beam offers a clear benefit in delivery time when compared to FF beam. Verification of pretreatment also represented the acceptable and comparable results in all plans using FF beam as well as FFF beam. Therefore, this study suggests that the use of FFF beam is feasible and efficient technique for prostate SABR.

60 APPLIED LIFE SCIENCES↗

Electromagnetic instability in an electron beam-ion channel system

The transverse electromagnetic instability in the electron beam-ion channel system is investigated using kinetic theory. The equilibrium distribution function of a relativistic electron beam, which takes into account a strong ion channel effect, is obtained. The linearized Vlasov equation is solved and the dispersion relation of the system is derived by perturbing the equilibrium with a high frequency electromagnetic wave (EMW). Analysis of the dispersion relation shows that the coupling of the electron beam with the transverse high frequency EMW is achieved through the deflection of the beam electrons due to the synergistic effects of the transverse high frequency EMW and transverse betatron oscillation. The numerical calculation finds that a branch of slow wave instability (SWI) with a wide frequency band is excited. The attenuation index of the SWI increases and its frequency band broadens as the normalized beam radii increases. Besides, the SWI will be suppressed as the longitudinal velocity of the electron beam increases to a certain value; meanwhile, a bunch of fast wave instability (FWI) is excited, which is equal to the increase of the relativistic factor. Also both the SWI and the FWI reach maximum when the EMW frequency meets a resonance condition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TDM/FM/FDMA - A modulation technique for multiple-beam satellites which precludes cochannel interference and allows non-uniform geographic distribution of user channels

The technique outlined in this paper is intended to eliminate the problems of cochannel interference and uniform geographic distribution of user channels which arise in conventional designs for a multiple spot beam communication satellite to serve mobile telephony users across the CONUS. By time multiplexing FM/FDMA signal ensembles so that only those beams operating on distinct frequency subbands are allowed to transmit concurrently, cochannel interference arising from simultaneous frequency subband reuse is precluded. Thus, time disjoint frequency reuse is accomplished over a repetitive sequence of fixed time slots. By assigning different size subbands to each time slot, a market of nonuniform users can be accommodated. The technique results in a greatly simplified antenna feed system design for the satellite, at a cost of imposing the need for time slot synchronization on the mobile FM receivers whose ability for rejecting adjacent channel interference is somewhat diminished.

Springett, J. C.↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of charge breeding of rubidium using Monte Carlo charge breeding code and generalized ECRIS model

A Monte Carlo charge breeding code (MCBC) is being developed by FAR-TECH, Inc. to model the capture and charge breeding of 1+ ion beam in an electron cyclotron resonance ion source (ECRIS) device. The ECRIS plasma is simulated using the generalized ECRIS model which has two choices of boundary settings, free boundary condition and Bohm condition. The charge state distribution of the extracted beam ions is calculated by solving the steady state ion continuity equations where the profiles of the captured ions are used as source terms. MCBC simulations of the charge breeding of Rb+ showed good agreement with recent charge breeding experiments at Argonne National Laboratory (ANL). MCBC correctly predicted the peak of highly charged ion state outputs under free boundary condition and similar charge state distribution width but a lower peak charge state under the Bohm condition. The comparisons between the simulation results and ANL experimental measurements are presented and discussed.

43 PARTICLE ACCELERATORS↗

Attosecond x-ray free-electron lasers utilizing an optical undulator in a self-selection regime

Accelerator-based x-ray free-electron lasers (XFELs) are the latest addition to the revolutionary tools of discovery for the 21st century. The two major components of an XFEL are an accelerator-produced electron beam and a magnetic undulator, which tend to be kilometer-scale long and expensive. A proof-of-principle demonstration of free-electron lasing at 27 nm using beams from compact laser wakefield accelerators was shown recently by using a magnetic undulator. However, scaling these concepts to x-ray wavelengths is far from straightforward as the requirements on the beam quality and jitters become much more stringent. Here, we present an ultracompact scheme to produce tens of attosecond x-ray pulses with several GW peak power utilizing a novel aspect of the FEL instability using a highly chirped, prebunched, and ultrabright tens of MeV electron beam from a plasma-based accelerator interacting with an optical undulator. The FEL resonant relation between the prebunched period and the energy selects resonant electrons automatically from the highly chirped beam which leads to a stable generation of attosecond x-ray pulses. Furthermore, two-color attosecond pulses with subfemtosecond separation can be produced by adjusting the energy distribution of the electron beam so that multiple FEL resonances occur at different locations within the beam. Such a tunable coherent attosecond x-ray sources may open up a new area of attosecond science enabled by x-ray attosecond pump/probe techniques. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗