In-Line Method for Calculating Peak Neutron Absorption by Fission Products Following a Change in Reactor Power
When the power level in an operating reactor is reduced the concentration of xenon-135 and samarium-149 temporarily increases as the nuclides (and their immediate precursors) equilibrate to the new power level. During this period, the increased inventory of these fission products causes an insertion of negative reactivity that can last for tens of hours. Understanding and predicting this transient reactivity effect is important in reactor design and operation. Explicit depletion calculations are often used to predict the reactivity behavior following a power change. However, these calculations require many time-steps to fully resolve the reactivity trend, and are correspondingly expensive. In 2010 an in-line method for estimating the peak xenon mass in a core following shutdown was described. However, there is no guarantee that the peak negative reactivity condition for a core will occur at peak xenon mass. Therefore, in this summary, we extend this original work using a new method that can predict the peak neutron absorption rate in the core due to {sup 135}Xe and {sup 149}Sm following any reduction in power. The proposed method can also be used to calculate the peak positive reactivity transient due to an increase in reactor power, but this scenario is of less interest in most reactor design applications. (authors)