Search NASA⌕ Search

SEARCH · Search NASA

Results for “CF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Neutron counting and gamma spectroscopy with PVT detectors.

Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare {sup 252}Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for {sup 252}Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Confinement Vessel Assay System: Design and Implementation Report

Los Alamos National Laboratory has a number of spherical confinement vessels remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1- to 2-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. We have developed a neutron assay system for the purposes of Materials Control and Accountability (MC&A) measurements of the vessel prior to and after cleanout. We present our approach to confronting the challenges in designing, building, and testing such a system. The system was designed to meet a set of functional and operational requirements. A Monte Carlo model was developed to aid in optimizing the detector design as well as to predict the systematic uncertainty associated with confinement vessel measurements. Initial testing was performed to optimize and determine various measurement parameters, and then the system was characterized using 252 Cf placed a various locations throughout the measurement system. Measurements were also performed with a 252 Cf source placed inside of small steel and HDPE shells to study the effect of moderation. These measurements compare favorably with their MCNPX model equivalent, making us confident that we can rely on the Monte Carlo simulation to predict the systematic uncertainty due to variations in response to material that may be localized at different points within a vessel.

36 MATERIALS SCIENCE↗

Progress in the Measurement of Prompt Neutron Output in Neutron-Induced Fission of 239 Pu: The Chi-Nu Project

Knowledge of the prompt neutron output from neutron-induced fission of 239 Pu is essential to nuclear defense and energy applications. Because the experimental data base is inadequate to constrain models of the spectrum of neutrons from fission, we have embarked on a multi-year program of new measurements of the prompt fission neutron spectrum as a function of the energy of the incident neutron that induces the fission. This is a joint LANL-LLNL project with participation by four university groups in advanced detector development. In the past year much progress has been achieved. The building housing the experiment has been completed and the flight paths including one for this experiment are now constructed. A parallel-plate avalanche counter (PPAC) containing 235 U is installed and working in the beam line. Neutron detectors for both low (<1 MeV) and high (> 0.5 MeV) neutrons have been assembled. The data acquisition system based on waveform digitizers has undergone extensive development and now can handle 10 PPAC channels and 10 neutron detectors simultaneously. In addition, a detector test station centered on a 252 Cf spontaneous fission chamber has been commissioned so that we can characterize our neutron detectors in a well understood experimental environment. Analysis of experiments at this facility has helped us understand the performance of several types of neutron detectors. In addition, the analysis work uncovered that the “standard” 252 Cf fission neutron spectrum in MCNPX disagrees significantly from that presently accepted by the international standards community. One year ago we submitted a report (LA-UR-11-05576) on the accuracies that could be reached under certain assumptions. Several sources of possible systematic uncertainties were identified, and procedures to control these uncertainties were suggested. This report is included as an appendix to this report. One element missing from these estimates was the contribution of backgrounds. It could not be quantified because, at that time, the building and flight path for the experiments had not been constructed. We now have made some measurements of the background and can now add this component to the accuracy projections. This report summarizes the progress in the past year. It also discusses measurements reported in the literature and some factors that should be considered when using these data to optimize parameters in nuclear model codes used in constructing evaluated nuclear data bases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Integrate Improved Systems for Nuclear Facility Ventilation and Exhaust Operations

Objective: The objective of this R&D project would complete the development of three new systems and integrate them into a single experimental effort. However, each of the three systems has stand-alone applicability across the DOE complex. At US DOE nuclear facilities, indoor air is filtered and ventilated for human occupancy, and exhaust air to the outdoor environment must be regulated and monitored. At least three technical standards address these functions, and the Los Alamos National Laboratory would complete an experimental facility to answer at least three questions: (1) Can the drag coefficient of a new Los Alamos air mixer be reduced for better operation in nuclear facility exhaust stacks? (2) Is it possible to verify the accuracy of a new dilution method for HEPA filter test facilities? (3) Is there a performance-based air flow metric (volumetric flow or mass flow) for operating HEPA filters? In summary, the three new systems are: a mixer, a diluter and a performance-based metric, respectively. The results of this project would be applicable to at least four technical standards: ANSI N13.1 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities; ASTM F1471 Standard Test Method for Air Cleaning Performance of a High-Efficiency Particulate Air Filter System, ASME N511: In-Service Testing of Nuclear Air Treatment, Heating, Ventilating, and Air-Conditioning Systems, and ASME AG-1: Code On Nuclear Air And Gas Treatment. All of the three proposed new systems must be combined into a single experimental device (i.e. to develop a new function of the Los Alamos aerosol wind tunnel). Technical Approach: The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally (2006) designed to evaluate small air samplers (cf. US EPA 40 CFR 53.42). In 2009, the tunnel was modified for exhaust stack verifications per the ANSI N13.1 standard. In 2010, modifications were started on the wind tunnel for testing HEPA filters (cf. ASTM F1471 and ASME N511). This project involves three systems that were developed for testing the 24*24*11 (inch) HEPA filters (i.e. the already mentioned mixer, diluter and metric). Prototypes of the mixer and the diluter have been built and individually tested on a preliminary basis. However, the third system (the HEPA metric method) has not been tested, since that requires complete operability of the aerosol wind tunnel device. (The experimental wind tunnel has test aerosol injection, control and measurement capabilities, and can be heated for temperature dependent measurements.) Benefits: US DOE facilities that use HEPA filters and/or require exhaust stacks from their nuclear facility buildings will benefit from access to the new hardware (mixer and diluter) and performance-based metric (for HEPA filter air flow).

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiological Characterization Technical Report on Californium-252 Sealed Source Transuranic Debris Waste for the Off-Site Source Recovery Project at Los Alamos National Laboratory

This document describes the development and approach for the radiological characterization of Cf-252 sealed sources for shipment to the Waste Isolation Pilot Plant. The report combines information on the nuclear material content of each individual source (mass or activity and date of manufacture) with information and data on the radionuclide distributions within the originating nuclear material. This approach allows for complete and accurate characterization of the waste container without the need to take additional measurements. The radionuclide uncertainties, developed from acceptable knowledge (AK) information regarding the source material, are applied to the summed activities in the drum. The AK information used in the characterization of Cf-252 sealed sources has been qualified by the peer review process, which has been reviewed and accepted by the Environmental Protection Agency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results For the Fourth Quarter 2013 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: SRR WAC targets or limits were met for all analyzed chemical and radioactive contaminants unless noted in this section. 59 Ni, 94 Nb, 247 Cm, 249 Cf, and 251 Cf are above the requested SRR target concentrations. However, they are below the detection limits established by SRNL. Norpar 13 and Isopar L have higher detection limits compared with the Saltstone WAC. The data provided in this report is based upon the concentrations in the sub-sample, and due to the limited solubility of these materials in aqueous solution, may not represent the concentrations of the analytes in Tank 50. The low insoluble solids content increases the measurement uncertainty for insoluble species. The semivolatile organic analysis (SVOA) method employed in the measurement of Norpar 13 and tributyl phosphate (TBP) has resulted in the erroneous reporting of a variety of small chain alcohols, including 4-methyl-3-hexanol and 5-methyl-3-hexanol, in previous quarterly sample reports. It has now been determined that these alcohols are an artifact of the sample preparation. Further work is being conducted in SRNL to delineate the conditions that produce these alcohols, and these findings will be reported separately.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Third Quarter 2013 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. 1 Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: SRR WAC targets or limits were met for all analyzed chemical and radioactive contaminates unless noted in this section. 59 Ni, 94 Nb, 247 Cm, 249 Cf, and 251 Cf are above the requested SRR target concentrations. 2 However, they are below the detection limits established by SRNL. 3 Norpar 13 and Isopar L have higher detection limits4 compared with the Saltstone WAC. 1 The data provided in this report is based upon the concentrations in the sub-sample, and due to the limited solubility in aqueous solution, may not represent the concentrations of the analytes in Tank 50. Finally, the low insoluble solids content increases the measurement uncertainty for insoluble species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample Results from Routine Salt Batch 7 Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 7B have been analyzed for 238 Pu, 90 Sr, 137 Cs, Inductively Coupled Plasma Emission Spectroscopy (ICPES), and Ion Chromatography Anions (IC-A). The results from the current microbatch samples are similar to those from earlier samples from this and previous macrobatches. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal, and there is a distinct positive trend in Cs removal, due to the use of the Next Generation Solvent (NGS). The Savannah River National Laboratory (SRNL) notes that historically, most measured Concentration Factor (CF) values during salt processing have been in the 12-14 range. However, recent processing gives CF values closer to 11. This observation does not indicate that the solvent performance is suffering, as the Decontamination Factor (DF) has still maintained consistently high values. Nevertheless, SRNL will continue to monitor for indications of process upsets. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Global Carbon Fiber Composites. Supply Chain Competitiveness Analysis

The objective of this study is to identify key opportunities in the carbon fiber (CF) supply chain where resources and investments can help advance the clean energy economy. The report focuses on four application areas—wind energy, aerospace, automotive, and pressure vessels—that top the list of industries using CF and carbon fiber reinforced polymers (CFRP) and are particularly relevant to the mission of U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (DOE EERE). For each of the four application areas, the report addresses the supply and demand trends within that sector, supply chain, and costs of carbon fiber and components.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Report on Developing Microstructure-Property Correlation in Reactor Materials using in situ High-Energy X-rays

This report provides a summary of research activities on understanding microstructure – property correlation in reactor materials using in situ high-energy X-rays. The report is a Level 2 deliverable in FY16 (M2CA-13-IL-AN_-0403-0111), under the Work Package CA-13-IL-AN_- 0403-01, “Microstructure-Property Correlation in Reactor Materials using in situ High Energy Xrays”, as part of the DOE-NE NEET Program. The objective of this project is to demonstrate the application of in situ high energy X-ray measurements of nuclear reactor materials under thermal-mechanical loading, to understand their microstructure-property relationships. The gained knowledge is expected to enable accurate predictions of mechanical performance of these materials subjected to extreme environments, and to further facilitate development of advanced reactor materials. The report provides detailed description of the in situ X-ray Radiated Materials (iRadMat) apparatus designed to interface with a servo-hydraulic load frame at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermal-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. We conducted several case studies using the iRadMat to obtain a better understanding of deformation and fracture mechanisms of irradiated materials. In situ X-ray measurements on neutron-irradiated pure metal and model alloy and several representative reactor materials, e.g. pure Fe, Fe-9Cr model alloy, 316 SS, HT-UPS, and duplex cast austenitic stainless steels (CASS) CF-8 were performed under tensile loading at temperatures of 20-400°C in vacuum. A combination of wide-angle X-ray scattering (WAXS), small-angle X-ray scattering (SAXS), and imaging techniques were utilized to interrogate microstructure at different length scales in real time while the specimen was subject to thermal-mechanical loading. In addition, in situ X-ray studies were complemented and benchmarked by ex situ characterization using advanced electron microscopy, atom probe tomography (APT) and micro/nano-indentation. The report presented in situ tensile test results on neutron-irradiated pure Fe, Fe-9Cr model alloy, 316 SS and CASS CF-8. These in situ experiments demonstrate the broad applications of the new capability in understanding several outstanding issues related to irradiated materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on FY19 Testing in Support of Integrated EPP-SMT Design Methods Development

Experiments in support of the development of the integrated Elastic–Perfectly Plastic (EPP) analysis and Simplified Model Test (SMT) design methodology continued in FY 2019. Major progress was made in the verification of the newly developed two-bar SMT and single-bar SMT (SBSMT) methods by performing tests on Alloy 617 and SS 316H at high temperatures. Comparable results were achieved when the materials were tested under same conditions using both techniques. Because of its simple test configuration, SBSMT was the preferred testing technique used to evaluate elastic follow-up effect and generate data in support of SMT-based design curves. Evaluation of elastic follow-up was started with testing SS 316H at 815°C using SBSMT in this reporting period. As a result of this effort, the basic procedure and test protocol to provide data in support of the development of SMT-based design curves were established. This report also summarizes recent test results for the pressurization SMT using test articles with key features on Alloy 617 at intermediate strain ranges and at a low temperature of 850°C. Although more test results are needed in order to fully understand the effect of primary load on SMT creep-fatigue (CF) life, the limited test data indicate that the primary load reduced the SMT life at intermediate strain ranges and high temperatures. Recognizing the advantages of the newly developed SBSMT method, a new test geometry was designed to allow the elevation of the primary load effect on SMT CF life with the SBSMT technique. Additionally, selected tests were performed on SS 316H (heat 101076) to provide basic information about the heat of material. The tests performed included high-temperature tensile, fatigue, creep fatigue, and thermomechanical experiments. The results will be used to support the verification of the material constitutive model developed at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

Special Analysis for the Disposal of the Idaho National Laboratory Contact Handled Sealed Sources Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This special analysis (SA) evaluates whether the Idaho National Laboratory (INL) Contact Handled Sealed Sources waste stream is suitable for disposal by shallow land burial at the Area 5 Radioactive Waste Management Site (RWMS) on the Nevada National Security Site (NNSS). The INL Contact Handled Sealed Sources waste stream consists of sealed radioactive sources. The INL Contact Handled Sealed Sources waste stream requires an SA to determine whether the Area 5 RWMS can accept radium-226 ( 226 Ra), tritium ( 3 H), and europium-152 ( 152 Eu) at activity concentrations exceeding the NNSS Waste Acceptance Criteria Action Levels and whether to accept four long-lived radionuclides (curium-247 [ 247 Cm], 250 Cm, californium-249 [ 249 Cf], 251 Cf) without action levels.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

UFCC Calibration Measurements for UO2 Samples

The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252 Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. A customized HDPE insert was designed to position the 252 Cf source under the UO 2 sample cans. The sample enrichments varied from depleted to 93% to establish the shape of the calibration curve and the measurement uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Separation and Purification of Berkelium-249 and Einsteinium-254

Berkelium-249 ( 249 Bk) and einsteinium-254 ( 254 Es) are isotopes of great importance for the investigation of berkelium and einsteinium chemical properties and super heavy element research. Therefore, it is necessary to be able to isolate acceptable, pure quantities of both isotopes to further research capabilities. These isotopes, along with californium-252 ( 252 Cf), are synthesized through the irradiation of mixed-curium targets in the High Flux Isotope Reactor (HFIR), which has the highest continuous thermal neutron flux in the world. Once irradiated, the targets are transferred to the Radiochemical Engineering Development Center for further chemical processing and final purification to separate 249 Bk and 254 Es from the remainder of isotopes present. Several methods of separation, such as the Berkex batch solvent extraction along with cation-exchange and alpha-hydroxy-isobutyrate (AHIB) columns, are employed to achieve a clean separation of the isotopes. Production Campaigns 74–77 are discussed in depth for 252 Cf, 249 Bk, and 254 Es production and isolation of 249 Bk and 254 Es. An attempt to isolate 257 Fm in Campaign 77 is discussed as well. Table 1 summarizes the total amount of material isolated in each campaign.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

UFCC Calibration Measurements for Bulk U 3 O 8 Powder Samples

The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF 6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252 Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. The sample enrichments varied from 0.72% to 91% to establish the shape of the calibration curve and the measurement uncertainties. The measurements included the singles, doubles, and triples rates. The time correlations between the 252 Cf source and the induced fission reactions reduced the statistical error in the doubles and triples rates to be small enough for useful measurements in 5-10 minutes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Macro-physical Properties of Shallow Cumulus from Integrated ARM Observations (Final Report)

Fair-weather shallow cumuli (ShCu) play an important role in many climate-related processes. Irregular geometry of ShCu and their strong temporal and spatial variability make it challenging to observe ShCu holistically and to represent them correctly in climate models. To improve ShCu parameterizations, information on both vertically and horizontally resolved cloud properties is required. Commonly, the vertically resolved cloud properties are provided by zenith pointing lidar-radar observations with a very narrow field of view (FOV). Thus, these “pencil-beam” properties may not be representative of a larger surrounding area. Limited number of areal-averaged cloud properties, such as fractional sky cover (FSC), are offered typically by wide-FOV observations. The main goal of our project was to integrate advantages of the narrow-FOV (vertical structure of clouds) and wide-FOV (spatial arrangement of clouds) observations for an improved characterization of single-layer ShCu observed at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site for an 18-yr period (2000-2017). There are four major accomplishments of our project, First, an updated operational cloud classification for days with ShCu has been suggested and evaluated through a detailed comparison with the manually curated records. Our classification extends successfully the latest ARM cloud type Value Added Product (VAP) based on the Active Remote Sensing of Clouds (ARSCL) cloud product by incorporating both cloud fraction (CF) provided by narrow-FOV ceilometer data and FSC from wide-FOV images offered by a Total Sky Imager (TSI). Moreover, our classification allows one to identify impact of instrumentation changes at the SGP site, namely the transition to KAZRARSCL with the updated cloud radar, on the identification of periods with single-layer ShCu. Second, a new approach that resolves cloud area distributions for a given region (up to 4x4 km 2 ) has been suggested and cloud equivalent diameters (CEDs) have been estimated for the first time. These estimations have been performed over a wide range of cloud sizes (about 0.01–3.5 km) with high temporal resolution (30s) using wide-FOV TSI images and cloud base height (CBH) provided by complementary narrow-FOV lidar measurements. Our simple and computationally inexpensive approach offers a previously unavailable dataset for process studies in the convective boundary layer and evaluation of ShCu parameterizations in cloud-resolving models. Third, a long-term integrated record of ShCu macrophysical properties has been developed. The developed record represents the longest available compilation of events with ShCu and includes (i) a novel visualization of the spatial variability in cloud cover both along- and across-wind directions, (ii) updated estimates of narrow-FOV CF and wide-FOV FSC, (iii) updated narrow-FOV CBH, and (iv) complementary data, such as wind speed and direction from the 915-MHz Radar Wind Profiler (RWP) data. The developed record has been used successfully to assess conventional observational estimates of cloud cover and their sensitivity to the following two factors: (i) instrument-dependent cloud detection and data merging criteria and (ii) FOV configuration. Fourth, co-variability of the ShCu macrophysical properties and environmental parameters has been analyzed for a 3-yr period (2016-2018). Our initial analysis includes diurnal changes of FSCs obtained for clouds with small, moderate and large CEDs and several environmental parameters, such as lifted condensation level (LCL) and mixed layer height (zi). Preliminary results of our analysis suggest that the horizontal extent of ShCu is controlled substantially by the sign and magnitude of difference between these two parameters (zi-LCL): the CED tends to grow with increase of this difference (zi exceeds LCL). We have initiated relationships between the ShCu and key atmospheric parameters that control both the development and evolution of ShCu using our new data product, which combines effectively the advantages of narrow-FOV data offered by zenith pointing cloud radars and lidars and wide-FOV TSI images. While the latest instrumentation at the ARM sites may address these challenging relationships in the future, we believe that the historical ARM data at the SGP site has not yet been fully utilized. Overall, our data product can be used by researchers working on a wide range of climate-related projects. These projects may include (i) a comprehensive evaluation of outputs from the Large-Eddy Simulation (LES) and single-column models for their future improvement, (ii) the representativeness of “short-period” results obtained from the previous model and observational studies and (iii) the planning of future field campaigns with focus on improved understanding of the diurnal cycle of cumulus convection.

54 ENVIRONMENTAL SCIENCES↗

Lightweight Materials - Carbon Fiber and Polymer Composites, Integrated Computational Materials Engineering (ICME) Predictive Tools Development for Low-Cost Carbon Fiber for Lightweight Vehicles (University of Virginia) (Final Report)

This project aimed to develop low-cost alternative precursors and processing techniques through the implementation of an integrated computational materials engineering (ICME) framework to evaluate precursor conversion kinetics. Once established, this framework was then used to down-select precursors for laboratory- and pilot-scale production to validate resulting carbon fiber (CF) material properties and process cost-savings. The two most promising approaches to reduce the cost of CFs were to (1) use new low-cost precursors and (2) reduce the energy requirements of CF processing. These approaches were investigated over the course of three phases of work, spanning 3.5 years. This report describes the overall project objectives, approach, and the key accomplishments in each phase.

36 MATERIALS SCIENCE↗

Risk Assessment using Certification Framework (SECARB Phase III Work Product 3.1.1b)

The Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III 1.5 million tonne CO 2 sequestration project is taking place on the eastern side of an oilfield in southwestern Mississippi in the so-called High Volume Injection Test area (HiVIT). The source of CO 2 for the project is the natural CO 2 reservoir at Jackson Dome, Mississippi. We apply the Certification Framework (CF) approach to assess the risk of CO 2 and brine leakage from the deep reservoir to various compartments where impacts could occur. The large depth (~10,000 ft, 3,050 m) of the Tuscaloosa Formation reservoir, presence of extensive thick marine mudstone confining zone, and well-known geology, among other factors, tend to minimize the likelihood of leakage. On the other hand, the large number of plugged and abandoned (P&A) wells provides potential flow paths for leakage upward to potable aquifers and potentially to the ground surface. A review of site characteristics relevant to leakage risk, simulation of the CO 2 injection, and modeling of performance of P&A wells is presented to demonstrate the application of the Certification Framework (CF) for leakage risk assessment in the context of an enhance Oil Recovery (EOR) project.

02 PETROLEUM↗