Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONSISTENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

SU-E-T-133: Assessing IMRT Treatment Delivery Accuracy and Consistency On a Varian TrueBeam Using the SunNuclear PerFraction EPID Dosimetry Software

Purpose: To assess if the TrueBeam HD120 collimator is delivering small IMRT fields accurately and consistently throughout the course of treatment using the SunNuclear PerFraction software. Methods: 7-field IMRT plans for 8 canine patients who passed IMRT QA using SunNuclear Mapcheck DQA were selected for this study. The animals were setup using CBCT image guidance. The EPID fluence maps were captured for each treatment field and each treatment fraction, with the first fraction EPID data serving as the baseline for comparison. The Sun Nuclear PerFraction Software was used to compare the EPID data for subsequent fractions using a Gamma (3%/3mm) pass rate of 90%. To simulate requirements for SRS, the data was reanalyzed using a Gamma (3%/1mm) pass rate of 90%. Low-dose, low- and high gradient thresholds were used to focus the analysis on clinically relevant parts of the dose distribution. Results: Not all fractions could be analyzed, because during some of the treatment courses the DICOM tags in the EPID images intermittently change from CU to US (unspecified), which would indicate a temporary loss of EPID calibration. This technical issue is still being investigated. For the remaining fractions, the vast majority (7/8 of patients, 95% of fractions, and 96.6% of fields) are passing the less stringent Gamma criteria. The more stringent Gamma criteria caused a drop in pass rate (90 % of fractions, 84% of fields). For the patient with the lowest pass rate, wet towel bolus was used. Another patient with low pass rates experienced masseter muscle wasting. Conclusion: EPID dosimetry using the PerFraction software demonstrated that the majority of fields passed a Gamma (3%/3mm) for IMRT treatments delivered with a TrueBeam HD120 MLC. Pass rates dropped for a DTA of 1mm to model SRS tolerances. PerFraction pass rates can flag missing bolus or internal shields. Sanjeev Saini is an employee of Sun Nuclear Corporation. For this study, a pre-release version of PerFRACTION 1.1 software from Sun Nuclear Corporation was used.

60 APPLIED LIFE SCIENCES↗

SU-F-T-26: A Study of the Consistency of Brachytherapy Treatments for Vaginal Cuff

Purpose: To evaluate to treatment consistency over the total number of fractions when treatment what HDR brachytherapy using the ML cylinders. At the same time the dosimetric impact on the critical organs is monitored over the total number of fractions. Methods: A retrospective analysis of 10 patients treated with Cylinder applicators, from 2015–2016 were considered for this study. The CT scans of these patients, taken before each treatment were separately imported in to the treatment planning system and paired with the initial CT scan after completing the contouring. Two sets of CT images were fused together with respective to the applicator, using landmark registration. The doses of each plan were imported as well and a cumulative dosimetric analysis was made for bladder, bowels, and rectum and PTV. Results: No contour of any of the OAR was exactly similar when CT images were fused on each other. The PTV volumes vary from fraction to fraction. There was always a difference between the doses received by the OARs between treatments. The maximum dose varied between 5% and 30% in rectum and bladder. The minimum dose varied between 5% and 8% in rectum and bladder. The average dose varied between 15% and 20% in rectum and bladder. Deviation in placement were noticed between fractions. Conclusion: The variation in volumes of OARs and isodoses near the OARs, indicate that the estimated doses to OARs on the planning system may not be the same dose delivered to the patient in all the fractions. There are no major differences between the prescribed dose and the delivered dose over the total number of fractions. In some cases the critical organs will benefit if the consecutive plans will made after the CT scans will be registered with the initial scan and then planned.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems: GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Consistent modelling of wind turbine noise propagation from source to receiver

The unsteady nature of wind turbine noise is a major reason for annoyance. The variation of far-field sound pressure levels is not only caused by the continuous change in wind turbine noise source levels but also by the unsteady flow field and the ground characteristics between the turbine and receiver. To take these phenomena into account, a consistent numerical technique that models the sound propagation from the source to receiver is developed. Large eddy simulation with an actuator line technique is employed for the flow modelling and the corresponding flow fields are used to simulate sound generation and propagation. The local blade relative velocity, angle of attack, and turbulence characteristics are input to the sound generation model. Time-dependent blade locations and the velocity between the noise source and receiver are considered within a quasi-3D propagation model. Long-range noise propagation of a 5 MW wind turbine is investigated. Sound pressure level time series evaluated at the source time are studied for varying wind speeds, surface roughness, and ground impedances within a 2000 m radius from the turbine.

17 WIND ENERGY↗

Geodynamically corrected Pliocene shoreline elevations in Australia consistent with midrange projections of Antarctic ice loss

The Mid-Pliocene represents the most recent interval in Earth history with climatic conditions similar to those expected in the coming decades. Mid-Pliocene sea level estimates therefore provide important constraints on projections of future ice sheet behavior and sea level change but differ by tens of meters due to local distortion of paleoshorelines caused by mantle dynamics. We combine an Australian sea level marker compilation with geodynamic simulations and probabilistic inversions to quantify and remove these post-Pliocene vertical motions at continental scale. Dynamic topography accounts for most of the observed sea level marker deflection, and correcting for this effect and glacial isostatic adjustment yields a Mid-Pliocene global mean sea level of +16.0 (+10.4 to +21.5) m (50th/16th to 84th percentiles). Recalibration of recent high-end sea level projections using this revised estimate implies a more stable Antarctic Ice Sheet under future warming scenarios, consistent with midrange forecasts of sea level rise that do not incorporate a marine ice cliff instability.

54 ENVIRONMENTAL SCIENCES↗

Conformational Changes in the Hepatitis B Virus Core Protein Are Consistent with a Role for Allostery in Virus Assembly

In infected cells, virus components must be organized at the right place and time to ensure assembly of infectious virions. From a different perspective, assembly must be prevented until all components are available. Hypothetically, this can be achieved by allosterically controlling assembly. Consistent with this hypothesis, here we show that the structure of the hepatitis B virus (HBV) core protein dimer, which can spontaneously self-assemble, is incompatible with capsid assembly. Systematic differences between core protein dimer and capsid conformations demonstrate linkage between the intradimer interface and interdimer contact surface. These structures also provide explanations for the capsid-dimer selectivity of some antibodies and the activities of assembly effectors. Solution studies suggest that the assembly-inactive state is more accurately an ensemble of conformations. Simulations show that allostery supports controlled assembly and results in capsids that are resistant to dissociation. We propose that allostery, as demonstrated in HBV, is common to most self-assembling viruses.

59 BASIC BIOLOGICAL SCIENCES↗

Fungal Hyphosphere Microbiomes Are Distinct from Surrounding Substrates and Show Consistent Association Patterns

Fungi and bacteria are the most abundant and diverse organisms in soils (perhaps more so than any other habitat on earth), and together these microorganisms contribute to broad soil ecosystem processes. There is a suite of bacteria that appears consistently within the physical space called the hyphosphere, the area of influence surrounding fungal hyphae.

59 BASIC BIOLOGICAL SCIENCES↗

Self-consistent inhomogeneity of quantum wells in II-VI semiconductors

An X-ray diffraction method that uses a slightly diverging (3') beam and maximally attainable diffraction angles {theta}{sub B} (as large as 77{sup o}) was developed to study quantum wells (QWs) with widths of 5-8 nm separated by wide (100-220 nm) barrier layers. The advantage of this method compared to the use of a parallel beam is an increase by two orders of magnitude in the intensity of the beam incident on the sample and an increase in the probability of diffraction for all QWs as a unified single crystal. It is found that the growth on GaAs substrates misoriented by 10{sup o} from the (001) plane in the [111]{sub II} direction brings about monoclinization of crystal lattices of the QW layers and barrier layers in opposite directions. Inhomogeneity of composition over the thickness of each well is observed. In the case of growth of a ZnSe/ZnMgSSe structure in which the layers have a crystal-lattice period close to the lattice period of the GaAs substrate, the QWs are inhomogeneously doped with elements from the composition of the barrier layers. The inhomogeneity of QW composition observed in the growth of mismatched layers in ZnCdSe/ZnSSe and ZnCdS/ZnSSe structures is caused by the fact that mismatch between the lattice parameters of QWs and barriers stimulates the growth of self-consistent compositions; this occurs due to a decrease in the Cd concentration in the Zn{sub 1-x}Cd{sub x}Se QW in the initial stages of growth compared to the Cd concentration in the flow of gases and an increase in the Zn concentration in the Cd{sub 1-x}Zn{sub x}S QW at small values of x up to the concentration matching GaAs (x = 0.4). The mismatch stresses are partially relaxed via dislocations with the (111){sub II} glide planes, as a result of which is observed the combination of rotation of the crystal planes of the layers and QW around the [1 1-bar 0] axis and almost cylindrical bending of the entire sample around the perpendicular [110] axis. Mismatch between lattice parameters of the ZnMgSSe barrier layers and the substrate brings about decomposition of these layers into two phases; this decomposition is caused by thermodynamic instability of the alloy.

36 MATERIALS SCIENCE↗

Finite-size scaling from the self-consistent theory of localization

Accepting the validity of Vollhardt and Woelfle's self-consistent theory of localization, we derive the finite-size scaling procedure used for studying the critical behavior in the d-dimensional case and based on the consideration of auxiliary quasi-1D systems. The obtained scaling functions for d = 2 and d = 3 are in good agreement with numerical results: it signifies the absence of substantial contradictions with the Vollhardt and Woelfle theory on the level of raw data. The results {nu} = 1.3-1.6, usually obtained at d = 3 for the critical exponent{nu} of the correlation length, are explained by the fact that dependence L + L{sub 0} with L{sub 0} > 0 (L is the transversal size of the system) is interpreted as L{sup 1/{nu}} with {nu} > 1. The modified scaling relations are derived for dimensions d {>=} 4; this demonstrates the incorrectness of the conventional treatment of data for d = 4 and d = 5, but establishes the constructive procedure for such a treatment. The consequences for other finite-size scaling variants are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Current-conducting properties of paper consisting of multiwall carbon nanotubes

Electrical conductivity {sigma}(T) of the paper consisting of multiwalled carbon nanotubes (MWCNTs) is studied in the temperature range 4.2-295 K, and its magnetoresistivity {rho}(B) at various temperatures in magnetic fields up to 9 T is analyzed. The temperature dependence of the paper electrical conductivity {sigma}(T) exhibits two-dimensional quantum corrections to the conductivity below 10 K. The dependences of negative magnetoresistivity {rho}(B) measured at various temperatures are used to estimate the wavefunction phase breakdown length L{sub {phi}} of conduction electrons and to obtain the temperature dependence L{sub {phi}} = constT{sup -p/2}, where p Almost-Equal-To 1/3. Similar dependences of electrical conductivity {sigma}(T), magnetoresistivity {rho}(B), and phase breakdown length L{sub {phi}}(T) are detected for the initial MWCNTs used to prepare the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermoelectric figure of merit of a material consisting of semiconductor or metal particles

It is found that the dimensionless thermoelectric figure of merit of a material consisting of a large number of ball-shaped semiconductor or metal particles can be much more than unity. The introduction of an insulator into the space between the particles is shown to sharply increase the power of the converter of heat energy into electric current energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multifractality and quantum diffusion from self-consistent theory of localization

Multifractal properties of wave functions in a disordered system can be derived from self-consistent theory of localization by Vollhardt and Wölfle. A diagrammatic interpretation of results allows to obtain all scaling relations used in numerical experiments. The arguments are given that the one-loop Wegner result for a space dimension d = 2 + ϵ is exact, so the multifractal spectrum is strictly parabolical. The σ-models are shown to be deficient at the four-loop level and the possible reasons of that are discussed. The extremely slow convergence to the thermodynamic limit is demonstrated. The open question on the relation between multifractality and a spatial dispersion of the diffusion coefficient D(ω, q) is resolved in the compromise manner due to ambiguity of the D(ω, q) definition. Comparison is made with the extensive numerical material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-consistent description of the inner crust of a neutron star within a realistic semimicroscopic model

The self-consistent semimicroscopic fully quantum approach developed recently for describing the structure of the inner crust of a neutron star within the Wigner-Seitz method is used to perform a systematic calculation of the properties of the system under study. Only the lowest layers of the crust in the vicinity of the point where a phase transition to a uniform state occurs are excluded from our consideration. Use is made of a realistic microscopic model that treats pairing in neutron matter with allowance for corrections of many-body theory to the Bardeen-Cooper-Schrieffer approximation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Example of a self-consistent solution for a fermion on domain wall

A self-consistent solution for a fermion coupled to static scalar field in the form of a kink (domain wall) is discussed. In particular, the case when the fermion occupies an excited nonzero frequency level in the presence of the domain-wall field is studied. The effect of the domain-wall profile distortion is calculated analytically.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum transport: Self-consistent approximations

Functional methods: Generating Φ {ϕ, G } functional of Baym on Schwinger-Keldysh contour; symmetries and conservation laws; thermodynamic consistency. (See [1]. Renormalization scheme can be found in [2].) Generalized kinetic approach: gradient approximation. (See [3]. Gradient expansion diagram technique see in [4].) Some helpful examples. (See [5].)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Incidence of an electron layer on an electrically insulated body with an unsteady self-consistent positive charge

Dynamics of an electron layer incident on the surface of an electrically insulated conducting body with an unsteady self-consistent positive charge is investigated. At the initial instant, the electron velocity is directed toward the body and the electron layer is not adjacent to the body surface. One-dimensional plane, cylindrical, and spherical electron motions in vacuum and against the background of motionless ions and neutral particles are considered. Exact analytical solutions to the set of nonlinear plasma hydrodynamics equations with absorbing boundary conditions for electrons are obtained. The spatial and time dependences of the electric field, electron density, and electron velocity are found. The time evolution of the surface charge density is determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-consistent modeling of radio-frequency plasma generation in stellarators

A self-consistent model of radio-frequency (RF) plasma generation in stellarators in the ion cyclotron frequency range is described. The model includes equations for the particle and energy balance and boundary conditions for Maxwell’s equations. The equation of charged particle balance takes into account the influx of particles due to ionization and their loss via diffusion and convection. The equation of electron energy balance takes into account the RF heating power source, as well as energy losses due to the excitation and electron-impact ionization of gas atoms, energy exchange via Coulomb collisions, and plasma heat conduction. The deposited RF power is calculated by solving the boundary problem for Maxwell’s equations. When describing the dissipation of the energy of the RF field, collisional absorption and Landau damping are taken into account. At each time step, Maxwell’s equations are solved for the current profiles of the plasma density and plasma temperature. The calculations are performed for a cylindrical plasma. The plasma is assumed to be axisymmetric and homogeneous along the plasma column. The system of balance equations is solved using the Crank-Nicholson scheme. Maxwell’s equations are solved in a one-dimensional approximation by using the Fourier transformation along the azimuthal and longitudinal coordinates. Results of simulations of RF plasma generation in the Uragan-2M stellarator by using a frame antenna operating at frequencies lower than the ion cyclotron frequency are presented. The calculations show that the slow wave generated by the antenna is efficiently absorbed at the periphery of the plasma column, due to which only a small fraction of the input power reaches the confinement region. As a result, the temperature on the axis of the plasma column remains low, whereas at the periphery it is substantially higher. This leads to strong absorption of the RF field at the periphery via the Landau mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of self-consistent electrostatic potential in quantum wells with several quantum confinement levels in high magnetic fields

The effect of self-consistent electrostatic potential on the spectrum of two-dimensional electron states in high magnetic fields is studied under the conditions where more than one quantum confinement subband is filled. The cases of magnetic field directed perpendicular to the quantum well plane and tilted magnetic field are considered. In the case of perpendicular magnetic field it is shown that two or more Landau levels that belong to different quantum confinement subbands can be degenerate in some ranges of concentrations (magnetic fields). The inclination of the magnetic field with respect to the growth direction produces opening of the energy gap between these levels; however, the gap as a function of concentration (magnetic field) remains almost constant in the same range of parameters.

36 MATERIALS SCIENCE↗