Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Motion coherence affects human perception and pursuit similarly

Pursuit and perception both require accurate information about the motion of objects. Recovering the motion of objects by integrating the motion of their components is a difficult visual task. Successful integration produces coherent global object motion, while a failure to integrate leaves the incoherent local motions of the components unlinked. We compared the ability of perception and pursuit to perform motion integration by measuring direction judgments and the concomitant eye-movement responses to line-figure parallelograms moving behind stationary rectangular apertures. The apertures were constructed such that only the line segments corresponding to the parallelogram's sides were visible; thus, recovering global motion required the integration of the local segment motion. We investigated several potential motion-integration rules by using stimuli with different object, vector-average, and line-segment terminator-motion directions. We used an oculometric decision rule to directly compare direction discrimination for pursuit and perception. For visible apertures, the percept was a coherent object, and both the pursuit and perceptual performance were close to the object-motion prediction. For invisible apertures, the percept was incoherently moving segments, and both the pursuit and perceptual performance were close to the terminator-motion prediction. Furthermore, both psychometric and oculometric direction thresholds were much higher for invisible apertures than for visible apertures. We constructed a model in which both perception and pursuit are driven by a shared motion-processing stage, with perception having an additional input from an independent static-processing stage. Model simulations were consistent with our perceptual and oculomotor data. Based on these results, we propose the use of pursuit as an objective and continuous measure of perceptual coherence. Our results support the view that pursuit and perception share a common motion-integration stage, perhaps within areas MT or MST.

NASA Center ARC↗

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure

Aim: The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF). Methods: Fifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting {sup 99m}Tc-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and {sup 18}F-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually. Results: There was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT. Conclusion: CZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Human and Technology Integration Evaluation of Advanced Automation and Data Visualization

While the existing United States (U.S.) light water reactors are highly reliable, safe, and provide a significant proportion of carbon-free electricity, the cost of operating and maintaining them has become less competitive compared to other electricity generating sources. The reason for the gap in operating and maintenance (O&M) costs can be at least in part attributed to the advent of new digital technologies that other electricity generating industries are currently using. Advanced capabilities including digital instrumentation and control (I&C) systems, advanced automation and analytics, and greater span of data integration (i.e., connectedness) across these non-nuclear plants has transformed the way work is performed and ultimately given them a competitive advantage in terms of the cost required for operating, maintaining, and supporting them. To reduce O&M cost and address obsolescence of the aging I&C infrastructure of the existing U.S. light water reactors, the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program Plant Modernization Pathway is conducting targeting multidisciplinary research that 1) delivers a sustainable business model to enable a cost-competitive U.S. nuclear industry and 2) is developing technology modernization solutions that address aging and obsolescence challenges. The work described in this report supports these two objectives and describes the demonstration of human and technology integration across recent industry collaborations to support their large-scale digital I&C modifications. This technical report describes the demonstration of the human and technology integration methodology in performing full-scale performance-based human-in-the-loop tests to evaluate plant-specific advanced automation and data visualization applications within these collaborators’ digital modifications. This technical report also documents future applications of human and technology integration that expand beyond main control room modernization and digital I&C upgrades, which have been a central focus to date. Thus, this technical report discusses how to implement human and technology integration across new business opportunities and how to develop an evaluation plan that defines measures and criteria, and documents key assumptions to support full plant modernization.

99 GENERAL AND MISCELLANEOUS↗

Lost in space: Onboard star identification using CCD star tracker data without an a priori attitude

There are many algorithms in use today which determine spacecraft attitude by identifying stars in the field of view of a star tracker. Some methods, which date from the early 1960's, compare the angular separation between observed stars with a small catalog. In the last 10 years, several methods have been developed which speed up the process and reduce the amount of memory needed, a key element to onboard attitude determination. However, each of these methods require some a priori knowledge of the spacecraft attitude. Although the Sun and magnetic field generally provide the necessary coarse attitude information, there are occasions when a spacecraft could get lost when it is not prudent to wait for sunlight. Also, the possibility of efficient attitude determination using only the highly accurate CCD star tracker could lead to fully autonomous spacecraft attitude determination. The need for redundant coarse sensors could thus be eliminated at substantial cost reduction. Some groups have extended their algorithms to implement a computation intense full sky scan. Some require large data bases. Both storage and speed are concerns for autonomous onboard systems. Neural network technology is even being explored by some as a possible solution, but because of the limited number of patterns that can be stored and large overhead, nothing concrete has resulted from these efforts. This paper presents an algorithm which, by descretizing the sky and filtering by visual magnitude of the brightness observed star, speeds up the lost in space star identification process while reducing the amount of necessary onboard computer storage compared to existing techniques.

Ketchum, Eleanor A.↗

Spatial updating in human parietal cortex

Single neurons in monkey parietal cortex update visual information in conjunction with eye movements. This remapping of stimulus representations is thought to contribute to spatial constancy. We hypothesized that a similar process occurs in human parietal cortex and that we could visualize it with functional MRI. We scanned subjects during a task that involved remapping of visual signals across hemifields. We observed an initial response in the hemisphere contralateral to the visual stimulus, followed by a remapped response in the hemisphere ipsilateral to the stimulus. We ruled out the possibility that this remapped response resulted from either eye movements or visual stimuli alone. Our results demonstrate that updating of visual information occurs in human parietal cortex.

NASA Discipline Neuroscience↗

The effect of a hyperdynamic environment on the development of the rat retina

The effects of a 2 G field on the retinal development of the layers in the rat and central visual system nuclei are investigated. The thickness of the retinal layers, ganglion cells, and brains of male and female Wistar rats suspended from an 18 foot diameter centrifuge creating a 2 G field are evaluated and compared with a control group. A decrease in the thickness of the outer nuclear layer (ONL) of 37.1 percent, of 58.5 percent in the inner nuclear layer (INL), and of 28.8 percent in the inner plexiform layer (IPL), and a reduction in body weight are observed in the 2-G rats. The data reveal that the ganglion cells and visual system nuclei activity correspond well with the control data; however, the medial terminal nucleus (MTN) activity is inhibited in the 2-G rats. It is concluded that the differences in ONL and IPL are attributed to body weight reduction, but the INL and MTN are affected by the 2-G conditions.

Murakami, D. M.↗

Contrast-Enhanced Proton Radiography for Patient Set-up by Using X-Ray CT Prior Knowledge

Purpose: To obtain a contrasted image of the tumor region during the setup for proton therapy in lung patients, by using proton radiography and x-ray computed tomography (CT) prior knowledge. Methods and Materials: Six lung cancer patients' CT scans were preprocessed by masking out the gross tumor volume (GTV), and digitally reconstructed radiographs along the planned beam's eye view (BEV) were generated, for a total of 27 projections. Proton radiographies (PR) were also computed for the same BEV through Monte Carlo simulations. The digitally reconstructed radiograph was subtracted from the corresponding proton image, resulting in a contrast-enhanced proton radiography (CEPR). Michelson contrast analysis was performed both on PR and CEPR. The tumor region was then automatically segmented on CEPR and compared to the ground truth (GT) provided by physicians in terms of Dice coefficient, accuracy, precision, sensitivity, and specificity. Results: Contrast on CEPR was, on average, 4 times better than on PR. For 10 lateral projections (±45° off of 90° or 270°), although it was not possible to distinguish the tumor region in the PR, CEPR offers excellent GTV visibility. The median ± quartile values of Dice, precision, and accuracy indexes were 0.86 ± 0.03, 0.86 ± 0.06, and 0.88 ± 0.02, respectively, thus confirming the reliability of the method in highlighting tumor boundaries. Sensitivity and specificity analysis demonstrated that there is no systematic over- or underestimation of the tumor region. Identification of the tumor boundaries using CEPR resulted in a more accurate and precise definition of GTV compared to that obtained from pretreatment CT. Conclusions: In most proton centers, the current clinical protocol is to align the patient using kV imaging with bony anatomy as a reference. We demonstrated that CEPR can significantly improve tumor visualization, allowing better patient set-up and permitting image guided proton therapy (IGPT)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

174P/Echeclus and Its Blue Coma Observed Post-outburst

It has been suggested that centaurs may lose their red surfaces and become bluer due to the onset of cometary activity, but the way in which cometary outbursts affect the surface composition and albedo of active centaurs is poorly understood. We obtained consistent visual-near-infrared (VNIR) reflectance spectra of the sporadically active centaur 174P/Echeclus during a period of inactivity in 2014 and six weeks after its outburst in 2016 to see if activity had observably changed the surface properties of the nucleus. We observed no change in the surface reflectance properties of Echeclus following the outburst compared to before, indicating that, in this case, any surface changes due to cometary activity were not sufficiently large to be observable from Earth. Our spectra and post-outburst imaging have revealed, however, that the remaining dust coma is not only blue compared to Echeclus, but also bluer than solar, with a spectral gradient of −7.7 ± 0.6% per 0.1 μm measured through the 0.61--0.88 μm wavelength range that appears to continue up to λ∼1.3 μm before becoming neutral. We conclude that the blue visual color of the dust is likely not a scattering effect, and instead may be indicative of the dust’s carbon-rich composition. Deposition of such blue, carbon-rich, comatic dust onto a red active centaur may be a mechanism by which its surface color could be neutralized.

79 ASTRONOMY AND ASTROPHYSICS↗

2022 Prentice Award Lecture: Advancing Retinal Imaging and Visual Function in Patient Management and Disease Mechanisms

Patient-based research plays a key role in probing basic visual mechanisms. Less-well recognized is the role of patient-based retinal imaging and visual function studies in elucidating disease mechanisms, which are accelerated by advances in imaging and function techniques and are most powerful when combined with the results from histology and animal models. A patient's visual complaints can be one key to patient management, but human data are also key to understanding disease mechanisms. Unfortunately, pathological changes can be difficult to detect. Before advanced retinal imaging, the measurement of visual function indicated the presence of pathological changes that were undetectable with existing clinical examination. Over the past few decades, advances in retinal imaging have increasingly revealed the unseen. This has led to great strides in the management of many diseases, particularly diabetic retinopathy and macular edema, and age-related macular degeneration. It is likely widely accepted that patient-based research, as in clinical trials, led to such positive outcomes. Both visual function measures and advanced retinal imaging have clearly demonstrated differences among retinal diseases. Contrary to initial thinking, sight-threatening damage in diabetes occurs to the outer retina and not only to the inner retina. This has been clearly indicated in patient results but has only gradually entered the clinical classifications and understanding of disease etiology. There is strikingly different pathophysiology for age-related macular degeneration compared with photoreceptor and retinal pigment epithelial genetic defects, yet research models and even some treatments confuse these. It is important to recognize the role that patient-based research plays in probing basic visual mechanisms and elucidating disease mechanisms, combining these findings with the concepts from histology and animal models. Thus, this article combines sample instrumentation from my laboratory and progress in the fields of retinal imaging and visual function.

60 APPLIED LIFE SCIENCES↗

Minimizing development costs for efficient many-core visualization using MCD3

Scientific visualization software increasingly needs to support many-core architectures. However, development time is a significant challenge due to the breadth and diversity of both visualization algorithms and architectures. With this work, we introduce a development environment for visualization algorithms on many-core devices that extends the traditional data-parallel primitive (DPP) approach with several existing constructs and an important new construct: meta-DPPs. We refer to our approach as MCD 3 — Meta-DPPs, Convenience routines, Data management, DPPs, and Devices. The twin goals of MCD 3 are to reduce developer time and to deliver efficient performance on many-core architectures, and our evaluation considers both of these goals. For development time, we study 57 algorithms implemented in the VTK-m software library and determine that MCD 3 leads to significant savings. For efficient performance, we survey ten studies looking at individual algorithms and determine that the MCD 3 hardware-agnostic approach leads to performance comparable to hardware-specific approaches: sometimes better, sometimes worse, and better in the aggregate. In total, we find that MCD 3 is an effective approach for scientific visualization libraries to support many-core architectures.

97 MATHEMATICS AND COMPUTING↗

Differences in Pre and Post Vascular Patterning of Retinas from ISS Crew Members and HDT Subjects by VESGEN Analysis

Accelerated research by NASA [1] has investigated the significant risks for visual and ocular impairments Spaceflight Associated Neuro-Ocular Syndrome /Visual Impairment/Intracranial Pressure (SANS/VIIP) incurred by microgravity spaceflight, especially long-duration missions. Our study investigates the role of blood vessels in the incidence and etiology of SANS/VIIP within the retinas of Astronaut crewmembers pre-and post-flight to the International Space Station (ISS) by NASA's VESsel GENeration Analysis (VESGEN). The response of retinal vessels in crewmembers to microgravity was compared to that of retinal vessels to Head-Down Tilt (HDT) in subjects undergoing 70-Day Bed Rest. The study tests the proposed hypothesis that cephalad fluid shifts missions, resulting in ocular and visual impairments, are necessarily mediated in part by retinal blood vessels, and are therefore accompanied by significant remodeling of retinal vasculature.Vascular patterns in the retinas of crew members and HDTBR subjects extracted from 30° infrared (IR) Heidelberg Spectralis® images collected pre/postflight and pre/post HDTBR, respectively, were analyzed by VESGEN (patent pending). a mature, automated software developed as a research discovery tool for progressive vascular diseases in the retina and other tissues [2]. The weighted, multi-parametric VESGEN analysis generates maps of branching arterial and venous trees and quantification by parameters such as the fractal dimension (Df, a modern measure of vascular space-filling capacity), vessel diameters, and densities of vessel length and number classified into specific branching generations by vascular physiological branching rules [2,3]. The retrospective study approved by NASA’s Institutional Review Board included six HDT subjects (NASA Flight Analogs Research Unit [FARU] Campaign 11; for example, [4]) and eight ISS crewmembers monitored by routine occupational surveillance who provided their study consents to NASA’s Lifetime Surveillance of Astronaut Health (LSAH). For the initial blinded VESGEN phase, ophthalmic retinal images were masked as to subject identity and pre- and post-status. In the second unblinded phase, VESGEN results were analyzed according to the pre- and post-status of left and right retinas matched to each subject. To complete our study, vascular results will be subjected to NASA biostatistical analysis and correlated with other ophthalmic and medical findings. Preliminary results for changes in the pre- to post-status of vascular patterning in the retinas of crewmembers and HDT subjects are strikingly opposite. By Df and other vascular branching measures, the space-filling capacity of arterial and venous trees decreased in a substantial subset of crewmembers (11/16 retinas). In contrast, vascular densities increased in a substantial subset of HDT subjects by the same parameters (6/10 retinas, currently excluding one anomalous subject). To conclude the study, biostatistical and medical analyses will be of critical importance for investigating the validity of these vascular findings. Vascular densities appeared to decrease in the retinas of crewmembers following ISS Missions, and increase in subjects after HDT. The vascular increases and decreases most likely derive primarily from limits of resolution to the ophthalmic imaging that does not capture the smallest vessels, rather than from vessel growth or atrophy. Differences in arterial and venous response to cephalad fluid shifts induced by ISS and HDT may have resulted from a long-duration conditioning phenomenon (for example, 6-month ISS missions compared to 70-day HDT), or the presence of gravity in HDT compared to microgravity onboard the ISS. To conclude our study, the biostatistical and medical analyses will be of critical importance for investigating the validity and significance of the VESGEN findings.

Murray, M. C.↗

Open Chemistry, JupyterLab, REST, and quantum chemistry

Quantum chemistry must evolve if it wants to fully leverage the benefits of the internet age, where the worldwide web offers a vast tapestry of tools that enable users to communicate and interact with complex data at the speed and convenience of a button press. The Open Chemistry project has developed an open-source framework that offers an end-to-end solution for producing, sharing, and visualizing quantum chemical data interactively on the web using an array of modern tools and approaches. These tools build on some of the best open-source community projects such as Jupyter for interactive online notebooks, coupled with 3D accelerated visualization, state-of-the-art computational chemistry codes including NWChem and Psi4, and emerging machine learning and data mining tools such as ChemML and ANI. They offer flexible formats to import and export data, along with approaches to compare computational and experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A High Energy–Density, Cobalt–Free, Low–Nickel LiNi 0.7 Mn 0.25 Al 0.05 O 2 Cathode with a High–Voltage Electrolyte for Lithium–Metal Batteries

Cobalt-free cathode materials have garnered increased attention for applications in next-generation batteries for electric vehicles, as cobalt is considered to have at a high supply chain risk. Here, the use of a localized saturated electrolyte (LSE) to enable stable cycling of a cobalt-free, low-nickel layered-oxide cathode LiNi 0.7 Mn 0.25 Al 0.05 O 2 (NMA-70) to higher voltages (4.6 V) in a lithium-metal battery is demonstrated. Compared to the baseline LP57 electrolyte, the LSE extends the cycle life from ≈100 cycles to ≈400 cycles before reaching 80% capacity retention. Visual indicators of cell degradation, such as product deposition, are observed on electrodes cycled in LP57. It is shown that cycling NMA-70 in LSE reduces the overall active material loss and overpotential growth during extended cycling. This is attributed to the formation of a beneficial fluorinated interphase layer, a lower degree of rock-salt phase formation, and a reduction in the gas evolution from the cathode surface. The decrease in gas evolution from the cathode cycled in LSE reflects a lower degree of electrolyte reactivity and an overall improvement in the safety characteristics of the cell. Furthermore, this study highlights the importance of a stable electrolyte to enable the high-voltage cycling of alternative, lower nickel, and cobalt-free cathodes.

25 ENERGY STORAGE↗

Coupling of Independent Electrochemical Reactions and Fluorescence at Closed Bipolar Interdigitated Electrode Arrays

Electrochemical reactions occurring at the opposite ends of bipolar electrodes (BPEs) are necessarily coupled, enabling electron transfer events at one end to be read out optically, for example, by coupling to fluorogenic reactions at the other end. In order to explore the potential of this technique for studying multiple redox events, arrays of parallel BPE interdigitated electrode arrays (IDEAs) were fabricated and integrated with separate analytical and reporter microfluidic channels, respectively, in a closed BPE configuration. The apparatus was initially evaluated employing Fe(CN) 6 3/4- in the analytical channel coupled to weakly emissive resazurin and strongly emissive resorufin as the fluorogenic redox reporter pair. We then used the device to investigate a proton-coupled electron transfer reaction, hydroquinone (QH 2 ) oxidation, in structures with an integrated pH modulation electrode (PME). A pH-sensitive dye, fluorescein, was co-introduced into the analytical channel to monitor PME modulation of solution pH, and its coupling to QH 2 oxidation, thereby permitting changes in solution pH, and consequently QH 2 oxidation rate, to be monitored directly in the analytical channel and compared to the fluorescence in the reporter channel. Additionally, diffusion of OH - generated at the PME produced a spatial pH profile that was visualized via fluorescein emission, and, because the oxidation of QH 2 at each BPE is strongly dependent on the local pH, via the coupled fluorogenic reaction at the opposite pole of the corresponding BPE digit in the reporter channel. Thus, BPE IDEAs support the coupling of independent redox reactions and the use of fluorescence imaging to explore a diverse set of spatially varying electrochemical phenomena realized in a variety of electrochemical geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural imaging of nanoscale phonon transport in ferroelectrics excited by metamaterial-enhanced terahertz fields

Nanoscale phonon transport is a key process that governs thermal conduction in a wide range of materials and devices. Creating controlled phonon populations by resonant excitation at terahertz (THz) frequencies can drastically change the characteristics of nanoscale thermal transport and allow a direct real-space characterization of phonon mean-free paths. Using metamaterial-enhanced terahertz excitation, we tailored a phononic excitation by selectively populating low-frequency phonons within a nanoscale volume in a ferroelectric BaTiO 3 thin film. Real-space time-resolved x-ray diffraction microscopy following THz excitation reveals ballistic phonon transport over a distance of hundreds of nm, two orders of magnitude longer than the averaged phonon mean-free path in BaTiO 3 . On longer length scales, diffusive phonon transport dominates the recovery of the transient strain response, largely due to heat conduction into the substrate. The measured real-space phonon transport can be directly compared with the phonon mean-free path as predicted by molecular dynamics modeling. In conclusion, this time-resolved real-space visualization of THz-matter interactions opens up opportunities to engineer and image nanoscale transient structural states with new functionalities.

36 MATERIALS SCIENCE↗

Intubation Containment System for Improved Protection From Aerosolized Particles During Airway Management

Worldwide efforts to protect front line providers performing endotracheal intubation during the COVID-19 pandemic have led to innovative devices. Authors evaluated the aerosol containment effectiveness of a novel intubation aerosol containment system (IACS) compared with a recently promoted intubation box and no protective barrier. In a simulation center at the authors’ university, the IACS was compared to no protective barrier and an intubation box. Aerosolization was simulated using a commercial fog machine and leakage of aerosolize mist was visually assessed. The IACS appeared to contain the aerosolized mist, while the intubation box allowed for mist to contact the laryngoscopist and contaminate the clinical space through arm port holes and the open caudal end. Both devices protected the laryngoscopist better than no protective barrier. The IACS with integrated sleeves and plastic drape appears to offer superior protection for the laryngoscopist and assistant providers from aerosolized particles.

aerosols↗

TU-F-12A-06: BEST IN PHYSICS (IMAGING) - A Novel Catheter-Based Radionuclide Imaging System to Characterize Atherosclerotic Plaque

Purpose: Atherosclerosis underlies coronary artery diseases, the leading cause of death in the United States and worldwide. In this study, we developed a novel catheter-based radionuclide imaging (CRI) system to image 18F-fluorodeoxyglucose (18F-FDG), a radionuclide, a marker of vascular inflammation, in murine carotid arteries and characterized the system for spatial resolution from multiple scintillating materials. Methods: The catheter system includes 35 mm and 8 mm fixed focal length lenses, which are subsequently connected to a CMOS camera and fiber holder. The distal ferrule of an image bundle is terminated with a wide-angle lens. The novelty of this system is a scintillating balloon with a crystal tip in the front of the wide angle lens to image light from the decay of 18F-FDG emission signal. The scintillating balloon is fabricated from 1mL of silicone RTV catalyst mixed with 1 mL base and 50 mg/mL calcium fluoride doped with Europium (CaF2:Eu). To identify the optimal scintillating materials with respect to resolution, we calculated modulation transfer function (MTF) of Yttrium Aluminum Garnet doped with Cerium (YAG:Ce), anthracene, and CaF2:Eu phosphors using a thin line optical phantom (Fig. 1a-1b). Macrophage-rich FVB murine atherosclerotic carotid plaque model (n = 4) was used in ex vivo experiments. Confirmatory imaging was also performed by an external optical imaging system (IVIS-200). Results: Analysis of the different phosphors (Fig 1b) showed that CaF2:Eu enabled the best resolution of 1.2μm. The CRI system visualized 18F-FDG in atherosclerotic plaques (Fig. 1d). The ligated left carotid (LR) artery exhibited 4× higher 18F-FDG signal intensity compared to the non-ligated right carotid (negative control) artery (1.65×10{sup 2} ±4.07×10{sup 1} vs. 4.44×10{sup 1}±2.17×10{sup 0}, A.U., p = 0.005) and confirmed with IVIS-200 (Fig. 1d). Conclusion: This CRI system enables high-resolution and sensitive detection of 18F-FDG uptake by murine atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

ShapeShop: Towards Understanding Deep Learning Representations via Interactive Experimentation

Deep learning is the driving force behind many recent technologies; however, deep neural networks are often viewed as “black-boxes” due to their internal complexity that is hard to understand. Little research focuses on helping people explore and understand the relationship between a user’s data and the learned representations in deep learning models. We present our ongoing work, ShapeShop, an interactive system for visualizing and understanding what semantics a neural network model has learned. Built using standard web technologies, ShapeShop allows users to experiment with and compare deep learning models to help explore the robustness of image classifiers.

Hohman, Frederick M.↗