Ultra-Sensitive Nuclear Measurements Initiative: Opportunities for Decay Counting of Environmental Radioisotopes Using Ultra-low-background Detection Systems

Executive Summary We present results from a scoping study whose intent was to define challenge measurements to be pursued on the Ultra-Sensitive Nuclear Measurements Initiative. Potential challenge measurements using new radiation detection technology in the shallow underground laboratory that would have substantial impact in environmental science were the focus of this study.

Runkle, Robert C.↗

Detection, Classification and Estimation of Radioactive Contraband from Uncertain Low-Count Measurements

In this final report we discuss the development of the Statistical Radiation Detection System (SRaDS), the next-generation radiation detection software system capable of extracting all available physics information, photon-by-photon, employing Bayesian model-based sequential statistical processing techniques and capable of making a decision when statistically justified. It is a system of computational algorithms consisting of a simple photoelectron processor for the basic system with a combined photoelectron/downscatter processor for the advanced system. Both algorithms have been demonstrated on laboratory data and are available for integration into standard radiation detectors and acquisition systems as well as specialized embedded processing hardware for real-time operations. This report incorporates the basic research performed leading to the development of SRaDS in the form of attached publications discussing the theory, development and validation of the processor and subsequent designs for this powerful solution to the detection problem plaguing the radiation area for a long time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of Uranium Molecular Deposition for Alpha-Counting Sources

Method development for molecular deposition of uranium onto aluminum 1100 plates was conducted with custom plating cells at Lawrence Livermore National Laboratory. The method development focused primarily on variation of electrode type, which was expected to directly influence plated sample homogeneity. Solid disc platinum and mesh platinum anodes were compared and data revealed that solid disc platinum anodes produced more homogenous uranium oxide films. However, the activity distribution also depended on the orientation of the platinum electrode relative to the aluminum cathode, starting current, and material composition of the plating cell. Experiments demonstrated these variables were difficult to control under the conditions available. Variation of plating parameters among a series of ten deposited plates yielded variations up to 30% in deposition efficiency. Teflon particles were observed on samples plated in Teflon cells, which poses a problem for alpha activity measurements of the plates. Preliminary electropolishing and chemical polishing studies were also conducted on the aluminum 1100 cathode plates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Scintillation Counting - Packard Triple-Label Calibration

The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Energy Efficiency Roadmap for Uganda, Making Energy Efficiency Count. Executive Summary

Like many countries in Sub-Saharan Africa, Uganda has focused its energy sector investments largely on increasing energy access by increasing energy supply. The links between energy efficiency and energy access, the importance of energy efficiency in new energy supply, and the multiple benefits of energy efficiency for the level and quality of energy available, have been largely overlooked. Implementing energy efficiency in parallel with expanding both the electricity grid and new clean energy generation reduces electricity demand and helps optimize the power supply so that it can serve more customers reliably at minimum cost. Ensuring efficient appliances are incorporated into energy access efforts provides improved energy services to customers. Energy efficiency is an important contributor to access to modern energy. This Energy Efficiency Roadmap for Uganda (Roadmap) is a response to the important role that electrical energy efficiency can play in meeting Uganda’s energy goals. Power Africa and the United Nations Sustainable Energy for All (SEforALL) initiatives collaborated with more than 24 stakeholders in Uganda to develop this document. The document estimates that if the most efficient technologies on the market were adopted, 2,224 gigawatt hours could be saved in 2030 across all sectors, representing 31% of the projected load. This translates into 341 megawatts of peak demand reductions, energy access to an additional 6 million rural customers and reduction of carbon dioxide emissions by 10.6 million tonnes in 2030. The Roadmap also finds that 91% of this technical potential is cost-effective, and 47% is achievable under conservative assumptions. The Roadmap prioritizes recommendations for implementing energy efficiency and maximizing benefits to meet the goals and priorities established in Uganda’s 2015 SEforALL Action Agenda. One important step is to create and increase demand for efficiency through long-term enabling policies and financial incentives combined with development of technical expertise in the labor force to allow for the promotion of new business models, such as energy service companies. A combination of enabling policies, financial schemes, regulations, enforcement, and skill development are needed to open the energy efficiency market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Modular and Flexible High-Frequency-Link Transformer with a Reduced Device Count and Zero High-Side Devices

In general, large power transformers (LPTs) are not interchangeable with each other and their high costs prohibit extensive spare inventories more so considering that on an average only 1.3 LPTs are manufactured for individual design. The latter pose a further challenge since given that the several existing LPTs are reaching their end of service lives, loss of plurality of such LPTs, that form the backbone of U.S. power grid, will clearly run into the problem of energy security related to the non-availability of sufficient spares (and extended lead time) exacerbated further by the fact that these spares are not interchangeable for installations at different locations. Conventional LPT cost millions of dollars and weighs significantly between approximately 100 and 400 tons. Two raw materials—copper and electrical steel—account for over 50 percent of the total cost of an LPT. In recent years, the price volatility of these two commodities in the global market has affected the manufacturing conditions and procurement strategy for LPTs. Transportation is also an important element of the total LPT cost, because an LPT can weigh significantly and often requires long-distance transport. Transporting an LPT is challenging—its large dimensions and heavy weight pose unique requirements to ensure safe and efficient transportation. Current road, rail, and port conditions are such that transportation is taking more time and becoming more expensive. Conventional low-frequency LPTs typically follow a monolithic approach to design due to historical reasons that need to transition to more modular and flexible (e.g., in voltage, impedance, and power flow) designs with ability to seamlessly/near-seamlessly scale. They should also have the ability to incorporate new technologies without in all cases redoing a LPT design from scratch. Given that the cost of raw materials has continued to increase, next-generation LPTs need to pursue avenues for reducing these costs. An added necessity is to reduce the transportability cost, which is significant in conventional LPTs. Further, given that LPTs are for the long term, they need to be durable, efficient, and fault tolerant with overloading capability. Given this backdrop, the objective and accomplishment of this one-year DOE (SPONSOR) R&D project, led by small business NextWatt LLC (PRIME, Lead PI: Dr. Sudip K. Mazumder) and University of Arkansas at Fayetteville (SUBAWARDEE, PI: Dr. Juan Balda) were to explore the design of a (8 – 20 kHz) high-frequency-link (HFL) based 100-MVA LPT with nominal voltage of 115/69 kV, with $15 - $22 dollars US per kVA when manufactured in “moderate” volume, with 99% energy-conversion efficiency, with 300% reduction in both volume and weight compared to a conventional LPT with the same electrical ratings, with impedance variation greater than 5%, with direct AC/AC power conversion capability, with very-high energy-conversion efficiency (using wide-bandgap SiC based field effect MOSFET devices) over a wide operating temperature, with reduction in both volume and weight with regard to conventional low frequency LPT, and with significant reduction in number of devices compared to state of the art solid state transformer topology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Counts in the ORTEC Detective X neutron channel

The ORTEC Detective X is a new radiation detector being produced and sold by AMTEK ORTEC. The main detector (for gamma radiation energy) is a High Purity Germanium (HPGe) crystal. A Geiger-Müller (GM) tube is used for radiation exposure measurements above about 2 mR/hr. As an available option, a Li6 F/ZnS neutron detector module can be attached to the Detective X to measure neutrons.