Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A Multi-scale Mathematical Model of Growth and Coalescence of Bubbles Beneath the Anode in an Aluminum Reduction Cell

Modeling of bubble shapes is challenging because of the wide range of length scales in aluminum reduction cells. A 3D multi-scale mathematical model was developed to understand the nucleation, growth and coalescence of bubbles beneath the anode and to investigate the transition of bubbles from the micro- to macro level. The motion of micro-bubbles is examined using the discrete bubble model (DBM) within a Lagrangian reference. An algorithm for the transition from discrete micro-bubbles to large bubbles, which are fully resolved by the volume of fluid (VOF) approach, is achieved using a user-defined function. The two-way coupling between discrete bubbles and continuous fluids is achieved by inter-phase momentum exchange. The model involves three kinds of bubble coalescence: micro-bubble coalescence is taken into account by the DBM; large bubbles swallowing up micro-bubbles are solved by the discrete-continuum transition model; the coalescence between large bubbles is handled by the VOF method. Numerical results show that the coverage and thickness of bubbles agree well with the experimental data in the literature. Bubble thickness stops increasing when the bubble elongates with the anode bottom, which is 4.0 to 4.5 mm. Meanwhile, two asymmetrical thick heads can be observed under the anode. Bubble release frequency increases with increasing current density.

36 MATERIALS SCIENCE↗

Respiratory-Induced Haemodynamic Changes: A Contributing Factor to IVC Filter Penetration

PurposeThe purpose of the study is to evaluate the influence of respiratory-induced vena caval hemodynamic changes on filter migration/penetration.Materials and MethodsAfter placement of either a Gunther Tulip or Celect IVC filter, 101 consecutive patients scheduled for filter retrieval were prospectively enrolled in this study. Pre-retrieval CT scans were used to assess filter complications and to calculate cross-sectional area in three locations: at level of filter strut fixation, 3 cm above and 3 cm below. A 3D finite element simulation was constructed on these data and direct IVC pressure was recorded during filter retrieval. Cross-sectional areas and pressures of the vena cava were measured during neutral breathing and in Valsalva maneuver and identified filter complications were recorded. A statistical analysis of these variables was then performed.ResultsDuring Valsalva maneuvers, a 60 % decrease of the IVC cross-sectional area and a fivefold increase in the IVC pressure were identified (p < 0.001). There was a statistically significant difference in the reduction of the cross-sectional area at the filter strut level (p < 0.001) in patient with filter penetration. Difficulty in filter retrieval was higher in penetrated or tilted filters (p < 0.001; p = 0.005). 3D computational models showed significant IVC deformation around the filter during Valsalva maneuver.ConclusionCaval morphology and hemodynamics are clearly affected by Valsalva maneuvers. A physiological reduction of IVC cross-sectional area is associated with higher risk of filter penetration, despite short dwell times. Physiologic data should be used to improve future filter designs to remain safely implanted over longer dwell times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A fully 3D approach for metal artifact reduction in computed tomography

Purpose: In computed tomography imaging metal objects in the region of interest introduce inconsistencies during data acquisition. Reconstructing these data leads to an image in spatial domain including star-shaped or stripe-like artifacts. In order to enhance the quality of the resulting image the influence of the metal objects can be reduced. Here, a metal artifact reduction (MAR) approach is proposed that is based on a recomputation of the inconsistent projection data using a fully three-dimensional Fourier-based interpolation. The success of the projection space restoration depends sensitively on a sensible continuation of neighboring structures into the recomputed area. Fortunately, structural information of the entire data is inherently included in the Fourier space of the data. This can be used for a reasonable recomputation of the inconsistent projection data. Methods: The key step of the proposed MAR strategy is the recomputation of the inconsistent projection data based on an interpolation using nonequispaced fast Fourier transforms (NFFT). The NFFT interpolation can be applied in arbitrary dimension. The approach overcomes the problem of adequate neighborhood definitions on irregular grids, since this is inherently given through the usage of higher dimensional Fourier transforms. Here, applications up to the third interpolation dimension are presented and validated. Furthermore, prior knowledge may be included by an appropriate damping of the transform during the interpolation step. This MAR method is applicable on each angular view of a detector row, on two-dimensional projection data as well as on three-dimensional projection data, e.g., a set of sequential acquisitions at different spatial positions, projection data of a spiral acquisition, or cone-beam projection data. Results: Results of the novel MAR scheme based on one-, two-, and three-dimensional NFFT interpolations are presented. All results are compared in projection data space and spatial domain with the well-known one-dimensional linear interpolation strategy. Conclusions: In conclusion, it is recommended to include as much spatial information into the recomputation step as possible. This is realized by increasing the dimension of the NFFT. The resulting image quality can be enhanced considerably.

60 APPLIED LIFE SCIENCES↗

Investigation of Computational Corrections to X-Ray Computed Tomography for Dimensional Metrology of Complex Additively Manufactured Parts

X-ray computed tomography (CT) is a nondestructive evaluation technique that may be used to image complex internal features without the line-of-sight restrictions inherent in conventional optical and contact (stylus) metrology instrumentation. Applications of CT metrology include material defects (porosity), dimensions and surface texture. However, scan artifacts, such as streaking, caused primarily by beam hardening and scatter, limit the accuracy of CTbased metrology. Reduction of these artifacts would improve the accuracy material properties and dimensional metrology information. This paper reports on the development of additively manufactured (AM) Ti5553 and 316L measurement phantoms with integral lattice (lattice) structures specifically designed to exhibit these artifacts. The phantoms were scanned in three CT systems and a scanning-probe CMM measurement. Surfaces generated from uncorrected CT data exhibited “dimple” defects that are not present in the CMM measurement. Correction methods were developed in Livermore Tomography Tools (LTT) software and this paper reports on the successful correction of these artifacts. This work is expected to have application in areas where characterization of defects, dimensions and surface texture using CT are critical.

42 ENGINEERING↗

Tracking the PACE of household energy usage: Energy usage impacts of projects financed through Property Assessed Clean Energy programs in California

This report examines the household-level energy impacts of residential property assessed clean energy (R-PACE) projects using normalized metered energy consumption methods. Our analysis covers projects that occurred through an R-PACE program between 2009 and 2017 and includes more than 25,000 electricity meters and 15,000 gas meters. We employ a comparison group, drawn from other R-PACE households with similar locational and usage characteristics whose projects were implemented at different times, to control for some non-project and non-weather factors that may impact energy use. We find that projects consisting of energy efficiency technologies save, on average, about 3% of household electricity usage and 3.5% of household gas usage. R-PACE financing, however, can be used to install central heating or air conditioning equipment for the first time. These projects would be expected to increase energy consumption. Since our data do not directly indicate which projects are new installations, we develop a simple algorithm for identifying them. Removing these inferred installation projects yields average savings of about 5% for electricity and 6% for gas for those households that remain in the sample. Given the mild California climate and the results of another study of similar California projects using similar methods, these results are in line with expectations. Solar PV projects yield large reductions in grid electricity use, averaging 69% of household consumption. We estimate that, collectively, all R-PACE projects installed in California through 2019 would generate annual reductions in grid-tied electricity consumption of 506 GWh (mostly due to solar PV) and gas consumption reductions of 2 million therms in a normal weather year. These impacts are equivalent to the electricity consumption of about 74,000 California households (including both efficiency and PV generation) and the gas consumption of about 4700 California households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefit of Regional Energy Balancing Service on Wind Integration in the Western Interconnection of the United States

Interest in various wide-area balancing schemes to help integrate wind have generated significant interest. As we have shown in past work, large balancing areas not only help with wind integration, but can also increase the efficiency of operations in systems without wind. Recent work on the Western Wind and Solar Integration Study (WWSIS) has found that combining balancing over the WestConnect footprint will increase the efficiency of commitment and dispatch at wind penetrations ranging from 10-20% of annual electricity demand, and will be essential for high penetrations and small balancing areas. In addition the Northwest Wind Integration Action Plan recommended balancing area cooperation as a method to help integrate the large potential wind development. In this paper we investigate the potential impact of a proposed Energy Imbalance Service on the ability of the non-market portions of Western Electricity Coordinating Councils (WECC) United States footprint to integrate wind energy. We will utilize data adapted from the WWSIS for the Western Interconnection. The analysis uses time-synchronized wind and load data to evaluate the potential for ramp requirement reduction that could be achieved with combined operation. Chronological analysis and ramp duration analysis quantify the benefit in terms of not only the ramp sizes, but the frequency of the potentially avoided ramps that must be managed by the non-wind generation fleet. Multiple approaches that can be used to achieve these benefits will also be suggested in the paper. We also suggest other approaches that can help achieve much of the benefit of full consolidation without requiring the physical consolidation of balancing areas.

17 WIND ENERGY↗

SU-E-T-284: Dose Plan Optimization When Using Hydrogel Prostate-Rectum Spacer: A Single Institution Experience

Purpose: To describe rectal dose reduction achieved and techniques used to take advantage of the increased peri-rectal spacing provided by injected polyethylene-glycol. Methods: Thirty prostate cancer patents were 2:1 randomized during a clinical trial to evaluate the effectiveness of injected poly-ethylene glycol hydrogel (SpaceOAR System) in creating space between the prostate and the anterior rectal wall. All patients received a baseline CT/MR scan and baseline IMRT treatment plan. Patients were randomized to receive hydrogel injection (n=20) or Control (n=10), followed by another CT/MR scan and treatment plan (single arc VMAT, 6 MV photons, 79.2 Gy, 44 fractions). Additional optimization structures were employed to constrain the dose to the rectum; specifically an avoidance structure to limit V75 <15%, and a control structure to limit the maximum relative dose <105% in the interface region of the anterior rectal wall and the prostate planning target volume. Dose volumetric data was analyzed for rectal volumes receiving 60 through 80 Gy. Results: Rectal dose reduction was observed in all patients who received the hydrogel. Volumetric analysis indicates a median rectal volume and (reduction from baseline plan) following spacer application of 4.9% (8.9%) at V60Gy, 3.8% (8.1%) at V65Gy, 2.5% (7.2%) at V70Gy, 1.6% (5.8%) at V75Gy, and 0.5% (2.5%) at V80Gy. Conclusion: Relative to planning without spacers, rectal dose constraints of 5%, 4%, 3%, 2%, 1% for V60, V65, V70, V75, and V80, should be obtainable when peri-rectal spacers are used. The combined effect of increased peri-rectal space provided by the hydrogel, with strict optimization objectives, resulted in reduced dose to the rectum. To maximize benefit, strict optimization objectives and reduced rectal dose constraints should be employed when creating plans for patients with perirectal spacers. Clinical Trial for SpaceOAR product conducted by Augmenix,Inc. The research site was paid to be a participating site.

60 APPLIED LIFE SCIENCES↗

Treatment Planning Constraints to Avoid Xerostomia in Head-and-Neck Radiotherapy: An Independent Test of QUANTEC Criteria Using a Prospectively Collected Dataset

Purpose: The severe reduction of salivary function (xerostomia) is a common complication after radiation therapy for head-and-neck cancer. Consequently, guidelines to ensure adequate function based on parotid gland tolerance dose-volume parameters have been suggested by the QUANTEC group and by Ortholan et al. We perform a validation test of these guidelines against a prospectively collected dataset and compared with a previously published dataset. Methods and Materials: Whole-mouth stimulated salivary flow data from 66 head-and-neck cancer patients treated with radiotherapy at the British Columbia Cancer Agency (BCCA) were measured, and treatment planning data were abstracted. Flow measurements were collected from 50 patients at 3 months, and 60 patients at 12-month follow-up. Previously published data from a second institution, Washington University in St. Louis (WUSTL), were used for comparison. A logistic model was used to describe the incidence of Grade 4 xerostomia as a function of the mean dose of the spared parotid gland. The rate of correctly predicting the lack of xerostomia (negative predictive value [NPV]) was computed for both the QUANTEC constraints and Ortholan et al. recommendation to constrain the total volume of both glands receiving more than 40 Gy to less than 33%. Results: Both datasets showed a rate of xerostomia of less than 20% when the mean dose to the least-irradiated parotid gland is kept to less than 20 Gy. Logistic model parameters for the incidence of xerostomia at 12 months after therapy, based on the least-irradiated gland, were D{sub 50} = 32.4 Gy and and {gamma} = 0.97. NPVs for QUANTEC guideline were 94% (BCCA data), and 90% (WUSTL data). For Ortholan et al. guideline NPVs were 85% (BCCA) and 86% (WUSTL). Conclusion: These data confirm that the QUANTEC guideline effectively avoids xerostomia, and this is somewhat more effective than constraints on the volume receiving more than 40 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear Astrophysics in the Storage Ring: Background Suppressed Simultaneous Measurement of (p,γ) and (p,n) Reactions

We report the application of the new elimination of Rutherford elastic scattering technique for the measurement of proton-induced reaction cross sections utilizing stored ions decelerated to astrophysical energies. This approach results in a background reduction factor of about 1 order of magnitude, enabling the first measurement of a (p, n) cross section in a storage ring. Here, the reaction channels 124 Xe⁢(p,n) and 124 Xe⁢(p,γ) have been studied just above the neutron threshold energy. The new data provide valuable constraints for Hauser-Feshbach theory and extrapolation of the (p,γ) cross section to lower energies. Most importantly, for nuclei of limited availability, the method represents a powerful improvement to efficiently study proton-induced reactions at energies within or close to the astrophysical Gamow window, bringing many reaction measurements within reach that were previously inaccessible in the laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Stream Monitoring of Off-Gasses from Plutonium Fluorination

Technology enabling real-time analysis is currently being developed to assess and advance processes used for the fluorination of actinides, which have increasing demands in the fields of forensics and molten salt reactor applications. Well established methods of fluorination use HF, a toxic and corrosive gas, which greatly limits materials of construction for probes and interfaces and is typically incompatible with detectors at greater than part per million quantities. The technology being developed utilizes Raman spectroscopy interrogation of the off-gas stream, providing detailed instantaneous process information in conditions up to 100% HF. The real-time data not only provides detailed reaction information, but also allows for a reduction, via process optimization, in the use of HF benefitting worker health and safety, minimizing waste, and prolonging equipment life.

PuF4, actinide fluorination, Raman↗

Multi-System Verification of Registrations for Image-Guided Radiotherapy in Clinical Trials

Purpose: To provide quantitative information on the image registration differences from multiple systems for image-guided radiotherapy (IGRT) credentialing and margin reduction in clinical trials. Methods and Materials: Images and IGRT shift results from three different treatment systems (Tomotherapy Hi-Art, Elekta Synergy, Varian Trilogy) have been sent from various institutions to the Image-Guided Therapy QA Center (ITC) for evaluation for the Radiation Therapy Oncology Group (RTOG) trials. Nine patient datasets (five head-and-neck and four prostate) were included in the comparison, with each patient having 1-4 daily individual IGRT studies. In all cases, daily shifts were re-calculated by re-registration of the planning CT with the daily IGRT data using three independent software systems (MIMvista, FocalSim, VelocityAI). Automatic fusion was used in all calculations. The results were compared with those submitted from institutions. Similar regions of interest (ROIs) and same initial positions were used in registrations for inter-system comparison. Different slice spacings for CBCT sampling and different ROIs for registration were used in some cases to observe the variation of registration due to these factors. Results: For the 54 comparisons with head-and-neck datasets, the absolute values of differences of the registration results between different systems were 2.6 {+-} 2.1 mm (mean {+-} SD; range 0.1-8.6 mm, left-right [LR]), 1.7 {+-} 1.3 mm (0.0-4.9 mm, superior-inferior [SI]), and 1.8 {+-} 1.1 mm (0.1-4.0 mm, anterior-posterior [AP]). For the 66 comparisons in prostate cases, the differences were 1.1 {+-} 1.0 mm (0.0-4.6 mm, LR), 2.1 {+-} 1.7 mm (0.0-6.6 mm, SI), and 2.0 {+-} 1.8 mm (0.1-6.9 mm, AP). The differences caused by the slice spacing variation were relatively small, and the different ROI selections in FocalSim and MIMvista also had limited impact. Conclusion: The extent of differences was reported when different systems were used for image registration. Careful examination and quality assurance of the image registration process are crucial before considering margin reduction using IGRT in clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decoding diffraction and spectroscopy data with machine learning: A tutorial

This Tutorial provides a step-by-step guide on how to apply supervised machine-learning techniques to analyze diffraction and spectroscopy data. This Tutorial details four models—a reconstruction-focused model, a regression-focused model, a hybrid reconstruction/regression model, and a multimodal model—that use x-ray diffraction profiles and vibrational density of states spectra to predict various microstructural descriptors. In this Tutorial, we cover data pre-processing steps, constructions of the models via dimensionality reduction and regression, training, and analysis of these models. Comparisons of the model’s performance are provided, highlighting the strength and weakness of the various approaches utilized.

36 MATERIALS SCIENCE↗

Tunable Semiconducting Behavior and Linear-Nonlinear Optical Properties of Ag–Sn Dual-Doped Nanocrystalline CdO Thin Films for Optoelectronics

Semiconductor-based thin films have a great impact on determining the anticipated optoelectronic device construction and the advancement of cutting-edge applications. Herein, Ag and Sn dual-doped nanocrystalline transparent conducting CdO thin films were prepared on glass substrates using a cost-effective spray coating method, and their structural, morphological, optical, and semiconducting behaviors were investigated. The successful incorporation of Ag and Sn resulted in the polycrystalline nature of the deposited films without the additional peaks, as verified by X-ray diffraction (XRD) analysis. The XRD report also revealed the enhanced crystallinity (65%) at the higher doping level (3 wt % Ag and Sn-doped CdO film). All the deposited CdO films exhibited homogeneous, spherical, or round-shaped grains, with agglomeration revealed by scanning electron microscopy analysis. UV–visible spectroscopy was utilized to determine the linear and nonlinear optical properties of the deposited CdO thin films, and a reduction in the band gap from 3.891 to 3.772 eV was observed. A significant enhancement in the first- and third-order nonlinear susceptibility and nonlinear refractive index of the doped CdO films was also observed with increasing doping concentration. Hall effect data were collected at room temperature to investigate the electrical properties of all of the CdO films. The charge carrier concentration of CdO thin films was increased from 142.08 × 10 18 to 169.10 × 10 18 cm –3 , and the highest conductivity was found to be 192 s/cm on doping 3 wt % Ag–Sn. All the CdO thin films exhibited n-type conductivity, while an incredible n-type to p-type charge carrier transition was noticed at a higher doping level (3 wt % Ag–Sn). The findings of the current work are expected to advance the synthesis of semiconductor thin films through cost-effective spray coating methods for optoelectronic device applications.

deposition↗

Consequences of Ca multisite occupation for the conducting properties of BaTiO{sub 3}

In combination with the dielectric modulus formalism and theoretical calculations, a newly developed defect incorporation mode, which is a combination of the standard A- and B-site doping mechanisms, is used to explain the conducting properties in 5 mol% Ca-doped BaTiO{sub 3}. Simulation results for Ca solution energies in the BaTiO{sub 3} lattice show that the new oxygen vacancy inducing mixed mode exhibits low defect energies. A reduction in dc conductivity compared with undoped BaTiO{sub 3} is witnessed for the incorporation of Ca. The conducting properties of 5 mol% Ca-doped BaTiO{sub 3} are analyzed using molecular dynamics and impedance spectroscopy. The ionic conductivity activation energies for each incorporation mode are calculated and good agreement with experimental data for oxygen migration is observed. The likely existence of the proposed defect configuration is also analyzed on the basis of these methods. - Graphical abstract: Oxygen vacancy formation as a result of self-compensation in Ca-doped BaTiO{sub 3}.

36 MATERIALS SCIENCE↗

Monitoring radiation use in cardiac fluoroscopy imaging procedures

Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance associated with relocation of the equipment to a new department. When tested under simulated conditions, the EWMA chart was capable of detecting a sustained 15% increase in average radiation output within 60 cases (<1 month of operation), while a 33% increase would be signaled within 20 cases. Conclusions: This technique offers a valuable enhancement to existing quality assurance programs in radiology that rely upon the testing of equipment radiation output at discrete time frames to ensure performance security.

60 APPLIED LIFE SCIENCES↗

Evaluation of Changes to the MTR Fuel Dissolution Flowsheet to Increase the Number of L-Bundles Charged to a Dissolver

Material Test Reactor (MTR) fuels are dissolved in the H-Canyon facility using a Hg-catalyzed, HNO₃ dissolution flowsheet. The flowsheet is based on experimental work in which laboratory-scale experiments were used to provide bounding values for both offgas and H₂ generation rates. The generation of H₂ gas, primarily from the dissolution of Al, is controlled by limiting the surface area exposed to the solution. The number of L-Bundles charged and their submergence level defines the exposed surface area which is directly proportional to the H₂ generation rate. For the MTR fuel dissolution flowsheet, the maximum number of L-Bundles which can be charged to a dissolver was specified as a function of the Al concentration in the solution and the submergence level of the bundle. The MTR fuels are currently dissolved in the 6.1D dissolver. To reach the desired terminal Al concentration, a total of 12 L-Bundles of fuel are dissolved per batch. Depending on the submergence level being used in the dissolver, the 12 bundles are dissolved in three charges of four bundles per charge or in a sequence of three, four, and five bundles. However, if six L-Bundles could be dissolved in the initial charge, a dissolver batch could be completed in two dissolutions instead of three. To assess the feasibility of dissolving six bundles in the first charge, the Savannah River National Laboratory evaluated changes to the MTR flowsheet which increase the number of bundles which can be charged to a dissolver. Since the development of the existing MTR fuel dissolution flowsheet, improved offgas measurement methods have been developed to more accurately calculate the offgas composition and generation rate during laboratory-scale dissolutions. In the first part of this study, improvements in the calibration model for the Raman spectrometer (used for offgas characterization) and a more effective data smoothing routine were applied to existing data. The uncertainty in the offgas composition data used to define the MTR fuel dissolution flowsheet were subsequently re-evaluated which resulted in an approximate 50% reduction in the uncertainty of the H₂ gas concentration measurements. The reduced uncertainty was used in new calculations to define the maximum number of L-Bundles which can be charged to either the 6.1D or 6.4D dissolver as a function of the Al concentration. With the reduced uncertainty in the H₂ concentration measurements, a flowsheet was defined which supported initially charging 6 bundles to a dissolver. This flowsheet is based on the use of 0.002 M Hg, an L-Bundle immersion depth of 54 in., an air sparge/purge flowrate of 40 scfm, an iodine reactor operating temperature of 200 °C, and not exceeding 60% of the H₂ LFL in the dissolver offgas. In the second phase of this study, calculations were performed to assess the impact of changing various operating parameters to increase the number of L-Bundles charged to an H-Canyon dissolver. Applying the improved offgas measurement techniques including the reduced uncertainty in the H₂ concentration measurements to the existing data, the number of bundles of MTR fuel which can be charged to either the 6.1D or 6.4D dissolver were calculated based on varying the bundle immersion depth (44-60 in.), air sparge/purge flowrate (40-60 scfm), iodine reactor operating temperature (150-200 °C), and the percentage of the H₂ LFL which must not be exceeded (60-76%). Qualitatively, the percentage of the LFL had the largest influence on the maximum number of bundles which can be charged to a dissolver followed by the air sparge/purge flowrate, L-Bundle immersion depth, and the iodine reactor operating temperature. During the evaluation of each variable, the other variables were held at the baseline flowsheet conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Energy Savings Potential from the Use of Demand Control Ventilation Systems in General Office Spaces in California

Demand controlled ventilation (DCV) was evaluated for general office spaces in California. A medium size office building meeting the prescriptive requirements of the 2008 California building energy efficiency standards (CEC 2008) was assumed in the building energy simulations performed with the EnergyPlus program to calculate the DCV energy savings potential in five typical California climates. Three design occupancy densities and two minimum ventilation rates were used as model inputs to cover a broader range of design variations. The assumed values of minimum ventilation rates in offices without DCV, based on two different measurement methods, were 81 and 28 cfm per occupant. These rates are based on the co-author's unpublished analyses of data from EPA's survey of 100 U.S. office buildings. These minimum ventilation rates exceed the 15 to 20 cfm per person required in most ventilation standards for offices. The cost effectiveness of applying DCV in general office spaces was estimated via a life cycle cost analyses that considered system costs and energy cost reductions. The results of the energy modeling indicate that the energy savings potential of DCV is largest in the desert area of California (climate zone 14), followed by Mountains (climate zone 16), Central Valley (climate zone 12), North Coast (climate zone 3), and South Coast (climate zone 6). The results of the life cycle cost analysis show DCV is cost effective for office spaces if the typical minimum ventilation rates without DCV is 81 cfm per person, except at the low design occupancy of 10 people per 1000 ft{sup 2} in climate zones 3 and 6. At the low design occupancy of 10 people per 1000 ft{sup 2}, the greatest DCV life cycle cost savings is a net present value (NPV) of $0.52/ft{sup 2} in climate zone 14, followed by $0.32/ft{sup 2} in climate zone 16 and $0.19/ft{sup 2} in climate zone 12. At the medium design occupancy of 15 people per 1000 ft{sup 2}, the DCV savings are higher with a NPV $0.93/ft{sup 2} in climate zone 14, followed by $0.55/ft{sup 2} in climate zone 16, $0.46/ft{sup 2} in climate zone 12, $0.30/ft{sup 2} in climate zone 3, $0.16/ft{sup 2} in climate zone 3. At the high design occupancy of 20 people per 1000 ft{sup 2}, the DCV savings are even higher with a NPV $1.37/ft{sup 2} in climate zone 14, followed by $0.86/ft{sup 2} in climate zone 16, $0.84/ft{sup 2} in climate zone 3, $0.82/ft{sup 2} in climate zone 12, and $0.65/ft{sup 2} in climate zone 6. DCV was not found to be cost effective if the typical minimum ventilation rate without DCV is 28 cfm per occupant, except at high design occupancy of 20 people per 1000 ft{sup 2} in climate zones 14 and 16. Until the large uncertainties about the base case ventilation rates in offices without DCV are reduced, the case for requiring DCV in general office spaces will be a weak case.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

P-model v1.0: an optimality-based light use efficiency model for simulating ecosystem gross primary production

Terrestrial photosynthesis is the basis for vegetation growth and drives the land carbon cycle. Accurately simulating gross primary production (GPP, ecosystem-level apparent photosynthesis) is key for satellite monitoring and Earth system model predictions under climate change. While robust models exist for describing leaf-level photosynthesis, predictions diverge due to uncertain photosynthetic traits and parameters which vary on multiple spatial and temporal scales. Here, we describe and evaluate a GPP (photosynthesis per unit ground area) model, the P-model, that combines the Farquhar–von Caemmerer–Berry model for C 3 photosynthesis with an optimality principle for the carbon assimilation–transpiration trade-off, and predicts a multi-day average light use efficiency (LUE) for any climate and C 3 vegetation type. The model builds on the theory developed in Prentice et al. (2014) and Wang et al. (2017a) and is extended to include low temperature effects on the intrinsic quantum yield and an empirical soil moisture stress factor. The model is forced with site-level data of the fraction of absorbed photosynthetically active radiation (fAPAR) and meteorological data and is evaluated against GPP estimates from a globally distributed network of ecosystem flux measurements. Although the P-model requires relatively few inputs, the R 2 for predicted versus observed GPP based on the full model setup is 0.75 (8 d mean, 126 sites) – similar to comparable satellite-data-driven GPP models but without predefined vegetation-type-specific parameters. The R 2 is reduced to 0.70 when not accounting for the reduction in quantum yield at low temperatures and effects of low soil moisture on LUE. The R 2 for the P-model-predicted LUE is 0.32 (means by site) and 0.48 (means by vegetation type). Applying this model for global-scale simulations yields a total global GPP of 106–122 Pg C yr –1 (mean of 2001–2011), depending on the fAPAR forcing data. The P-model provides a simple but powerful method for predicting – rather than prescribing – light use efficiency and simulating terrestrial photosynthesis across a wide range of conditions. The model is available as an R package (rpmodel).

54 ENVIRONMENTAL SCIENCES↗