Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Selective Detection of Intermediate-Amplitude Motion by Solid-State NMR

The coexistence of rigid and mobile molecules or molecular segments abounds in biomolecular assemblies. Examples include the carbohydrate-rich cell walls of plants and intrinsically disordered proteins that contain rigid β-sheet cores. In solid-state nuclear magnetic resonance (NMR) spectroscopy, dipolar polarization transfer experiments are well suited for detecting rigid components, whereas scalar-coupling experiments are well suited for detecting highly mobile components. However, few NMR methods are available to detect the segments that undergo intermediate-amplitude fast motion. Here, we introduce two NMR experiments, a two-dimensional T 2H -filtered CP-hCH correlation and a three-dimensional J-INADEQUATE CCH correlation, to observe this intermediate-amplitude motion. Both experiments involve 1 H detection under fast magic-angle spinning (MAS). By combining 1 H transverse relaxation (T 2H ) filters with dipolar polarization transfer, we suppress the signals of both highly rigid and highly mobile species, thus revealing the signals of intermediate mobile species. 1 H detection under fast MAS is crucial for distinguishing the different motional amplitudes. Here, we demonstrate these techniques on several plant cell wall samples and show that they allow the selective detection and resolution of certain hemicellulose and pectin signals, which are usually masked by the signals of the rigid cellulose and the highly dynamic pectins in purely dipolar and scalar NMR spectra.

59 BASIC BIOLOGICAL SCIENCES↗

Redox-Based Electrochemical Affinity Sensor for Detection of Aqueous Pertechnetate Anion

Rapid, selective, in-situ detection of TcO4- in multicomponent matrices consisting of interfering anions such as the ubiquitous NO3- and Cl- or the isostructural and isoelectronic CrO42- is challenging. Present sensors mostly lack the selectivity to exclude these interferences, or the sensitivity to meet the detection limits that are lower than the drinking water standards across the globe. This work presents an affinity based electrochemical sensor for TcO4- detection that relies on selective reductive precipitation of aqueous TcO4- induced by a capture probe immobilized on an electrode platform. This results in a direct decrease of the electron transfer current, the magnitude of the decrease being proportional to the amount of TcO4- added. Using this approach, we were able to achieve a detection limit of 1x10-10 M, which is lower than the drinking water standard of 5.2x10-10 M set by United States Environmental Protection Agency. Our proposed approach also allowed us to detect TcO4- from a multicomponent groundwater sample obtained from a well at the Hanford site in Washington (well 299-W19-36) that also contained NO3- , Cl- and CrO42-, without discernably affecting the detection limits.

Chatterjee, Sayandev↗

An End-To-End Earthquake Detection Method for Joint Phase Picking and Association Using Deep Learning

Earthquake monitoring by seismic networks typically involves a workflow consisting of phase detection/picking, association, and location tasks. In recent years, the accuracy of these individual stages has been improved through the use of machine learning techniques. Here, in this study, we introduce a new end-to-end approach that improves overall earthquake detection accuracy by jointly optimizing each stage of the detection pipeline. We propose a neural network architecture for the task of multi-station processing of seismic waveforms recorded over a seismic network. This end-to-end architecture consists of three sub-networks: a backbone network that extracts features from raw waveforms, a phase picking sub-network that picks P- and S-wave arrivals based on these features, and an event detection sub-network that aggregates the features from multiple stations to associate and detect earthquakes across a seismic network. We use these sub-networks together with a shift-and-stack module based on back-projection that introduces kinematic constraints on arrival times, allowing the neural network model to generalize to different velocity models and to variable station geometry in seismic networks. We evaluate our proposed method on the STanford EArthquake Dataset (STEAD) and on the 2019 Ridgecrest, CA earthquake sequence. The results demonstrate that our end-to-end approach can effectively pick P- and S-wave arrivals and achieve earthquake detection accuracy rivaling that of other state-of-the-art approaches. Because our approach preserves information across tasks in the detection pipeline, it has the potential to outperform approaches that do not.

58 GEOSCIENCES↗

An Overview of ARTMIP's Tier 2 Reanalysis Intercomparison: Uncertainty in the Detection of Atmospheric Rivers and Their Associated Precipitation

Atmospheric rivers, or long but narrow regions of enhanced water vapor transport, are an important component of the hydrologic cycle as they are responsible for much of the poleward transport of water vapor and result in precipitation, sometimes extreme in intensity. Despite their importance, much uncertainty remains in the detection of atmospheric rivers in large datasets such as reanalyses and century scale climate simulations. To understand this uncertainty, the Atmospheric River Tracking Method Intercomparison Project (ARTMIP) developed tiered experiments, including the Tier 2 Reanalysis Intercomparison that is presented here. Eleven detection algorithms submitted hourly tags--binary fields indicating the presence or absence of atmospheric rivers--of detected atmospheric rivers in the Modern Era Retrospective Analysis for Research and Applications, version 2 (MERRA-2) and European Centre for Medium-Range Weather Forecasts' Reanalysis Version 5 (ERA5) as well as six-hourly tags in the Japanese 55-year Reanalysis (JRA-55). Due to a higher climatological mean for integrated water vapor transport in MERRA-2, atmospheric rivers were detected more frequently relative to the other two reanalyses, particularly in algorithms that use a fixed threshold for water vapor transport. The finer horizontal resolution of ERA5 resulted in narrower atmospheric rivers and an ability to detect atmospheric rivers along resolved coastlines. We found that the fraction of hemispheric area covered by ARs varies throughout the year in all three reanalyses, with different atmospheric river detection tools having different seasonal cycles.

54 ENVIRONMENTAL SCIENCES↗

Summertime Continental Shallow Cumulus Cloud Detection Using GOES‐16 Satellite and Ground‐Based Ceilometer at North Alabama

Abstract Accurate simulations of boundary layer cloud processes remain challenging in Earth system modeling. Observations are essential to evaluate and improve models of such processes. This study introduces a comprehensive validation framework for a satellite‐based detection algorithm of continental shallow cumulus (ShCu) clouds during the daytime, which was initially developed using ground‐based observations of stereo cameras at the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains site (J. Tian et al., 2021, https://doi.org/10.3390/rs13122309 , 2022, https://doi.org/10.1029/2021gl097070 ). To validate this algorithm, the framework employs ground‐based ceilometer measurements from North Alabama (NA) where ShCu populations are prevalent. This study first generates clear‐sky surface reflectance maps at NA and identifies ShCu pixels with a detection threshold using Geostationary Operational Environmental Satellite (GOES) reflectance data. The obtained cloud fractions (CFs) are then compared against CFs from a ground‐based ceilometer, considering factors such as observed area differences, satellite parallax issue, and systematic biases. We found that with a detection threshold (∆R) of 0.05, the ShCu detection algorithm is effective for NA, enabling the reproduction of hourly ShCu CFs using GOES. Our framework is straightforward and easily repeatable to evaluate the effectiveness of a ∆R threshold for detecting ShCu clouds in various geographic regions where ceilometers are deployed. This satellite detection of ShCu provides a crucial regional context for ground‐based measurements, facilitating the tracking of convection initiation and its coupling with land surface conditions. Integrating localized ground‐based and regional satellite data will enhance our ability to conduct thorough studies of cloud morphology and land‐atmosphere interactions in North Alabama.

54 ENVIRONMENTAL SCIENCES↗

PECAN: library-free peptide detection for data-independent acquisition tandem mass spectrometry data

Data-independent acquisition (DIA) is an emerging mass spectrometry (MS)-based technique for unbiased and reproducible measurement of protein mixtures. DIA tandem mass spectrometry spectra are often highly multiplexed, containing product ions from multiple cofragmenting precursors. Detecting peptides directly from DIA data is therefore challenging; most DIA data analyses require spectral libraries. Here we present PECECAN (http://pecan.maccosslab.org), a library-free, peptide-centric tool that robustly and accurately detects peptides directly from DIA data. PECECAN reports evidence of detection based on product ion scoring, which enables detection of low-abundance analytes with poor precursor ion signal. We demonstrate the chromatographic peak picking accuracy and peptide detection capability of PECECAN, and we further validate its detection with data-dependent acquisition and targeted analyses. Lastly, we used PECECAN to build a plasma proteome library from DIA data and to query known sequence variants.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗

Automatic detection of methane emissions in multispectral satellite imagery using a vision transformer

Curbing methane emissions is among the most effective actions that can be taken to slow down global warming. However, monitoring emissions remains challenging, as detection methods have a limited quantification completeness due to trade-offs that have to be made between coverage, resolution and detection accuracy. Here we show that deep learning can overcome the trade-off in terms of spectral resolution that comes with multi-spectral satellite data, resulting in a methane detection tool with global coverage and high temporal and spatial resolution. We compare our detections with airborne methane measurement campaigns, which suggests that our method can detect methane point sources in Sentinel-2 data down to plumes of 0.01 km 2 , corresponding to 200 to 300 kg CH 4 /h -1 sources. Our model shows an order of magnitude improvement over the state-of-the-art, providing a significant step towards the automated, high resolution detection of methane emissions at a global scale, every few days.

54 ENVIRONMENTAL SCIENCES↗

An optimized microfabricated platform for the optical generation and detection of hyperpolarized 129 Xe

Low thermal-equilibrium nuclear spin polarizations and the need for sophisticated instrumentation render conventional nuclear magnetic resonance (NMR) spectroscopy and imaging (MRI) incompatible with small-scale microfluidic devices. Hyperpolarized 129 Xe gas has found use in the study of many materials but has required very large and expensive instrumentation. Recently a microfabricated device with modest instrumentation demonstrated all-optical hyperpolarization and detection of 129 Xe gas. This device was limited by 129 Xe polarizations less than 1%, 129 Xe NMR signals smaller than 20 nT, and transport of hyperpolarized 129 Xe over millimeter lengths. Higher polarizations, versatile detection schemes, and flow of 129 Xe over larger distances are desirable for wider applications. Here we demonstrate an ultra-sensitive microfabricated platform that achieves 129 Xe polarizations reaching 7%, NMR signals exceeding 1 μT, lifetimes up to 6 s, and simultaneous two-mode detection, consisting of a high-sensitivity in situ channel with signal-to-noise of 10 5 and a lower-sensitivity ex situ detection channel which may be useful in a wider variety of conditions. 129 Xe is hyperpolarized and detected in locations more than 1 cm apart. Our versatile device is an optimal platform for microfluidic magnetic resonance in particular, but equally attractive for wider nuclear spin applications benefitting from ultra-sensitive detection, long coherences, and simple instrumentation.

36 MATERIALS SCIENCE↗

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES↗

Online data-driven changepoint detection for high-dimensional dynamical systems

In this study, the detection of anomalies or transitions in complex dynamical systems is of critical importance to various applications. In this study, we propose the use of machine learning to detect changepoints for high-dimensional dynamical systems. Here, changepoints indicate instances in time when the underlying dynamical system has a fundamentally different characteristic—which may be due to a change in the model parameters or due to intermittent phenomena arising from the same model. We propose two complementary approaches to achieve this, with the first devised using arguments from probabilistic unsupervised learning and the latter devised using supervised deep learning. To accelerate the deployment of transition detection algorithms in high-dimensional dynamical systems, we introduce dimensionality reduction techniques. Our experiments demonstrate that transitions can be detected efficiently, in real-time, for the two-dimensional forced Kolmogorov flow and the Rössler dynamical system, which are characterized by anomalous regimes in phase space where dynamics are perturbed off the attractor at potentially uneven intervals. Finally, we also demonstrate how variations in the frequency of detected changepoints may be utilized to detect a significant modification to the underlying model parameters by utilizing the Lorenz-63 dynamical system.

97 MATHEMATICS AND COMPUTING↗

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation↗

Detecting Clandestine Reprocessing Activities in the Middle East

Nuclear reprocessing plants release krypton-85 that can be detected in the atmospheric air downwind from the facility. Atmospheric transport modelling is applied to determine the area over which krypton-85 emissions from undeclared reprocessing activities in the Middle East would still be detectable against the background. This is used to assess the feasibility of monitoring known reprocessing plants and detecting unknown reprocessing plants. The annual wind flow over Dimona is analyzed and it is concluded that a known reprocessing plant could be monitored with one or a few fixed monitoring stations. Unknown reprocessing plants are more difficult to detect due to the high background levels of krypton-85 and fixed stations would not be feasible. Instead, the number of air samples that have to be taken at random locations for a successful detection is calculated. Taking random air samples can present a logistical effort but can yield reliable and timely detection of clandestine reprocessing plants. This could be used for verification of an international treaty that prohibits the separation of plutonium in the Middle East.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A CONNECTION BETWEEN APPARENT VLBA JET SPEEDS AND INITIAL ACTIVE GALACTIC NUCLEUS DETECTIONS MADE BY THE FERMI GAMMA-RAY OBSERVATORY

In its first three months of operations, the Fermi Gamma-Ray Observatory has detected approximately one quarter of the radio-flux-limited MOJAVE sample of bright flat-spectrum active galactic nuclei (AGNs) at energies above 100 MeV. We have investigated the apparent parsec-scale jet speeds of 26 MOJAVE AGNs measured by the Very Long Baseline Array (VLBA) that are in the LAT bright AGN sample (LBAS). We find that the {gamma}-ray bright quasars have faster jets on average than the non-LBAS quasars, with a median of 15c, and values ranging up to 34c. The LBAS AGNs in which the LAT has detected significant {gamma}-ray flux variability generally have faster jets than the nonvariable ones. These findings are in overall agreement with earlier results based on nonuniform EGRET data which suggested that {gamma}-ray bright AGNs have preferentially higher Doppler boosting factors than other blazar jets. However, the relatively low LAT detection rates for the full MOJAVE sample (24%) and previously known MOJAVE EGRET-detected blazars (43%) imply that Doppler boosting is not the sole factor that determines whether a particular AGN is bright at {gamma}-ray energies. The slower apparent jet speeds of LBAS BL Lac objects and their higher overall LAT detection rate as compared to quasars suggest that the former are being detected by Fermi because of their higher intrinsic (unbeamed) {gamma}-ray to radio luminosity ratios.

79 ASTRONOMY AND ASTROPHYSICS↗

A SPITZER SURVEY OF MID-INFRARED MOLECULAR EMISSION FROM PROTOPLANETARY DISKS. I. DETECTION RATES

We present a Spitzer InfraRed Spectrometer search for 10-36 {mu}m molecular emission from a large sample of protoplanetary disks, including lines from H{sub 2}O, OH, C{sub 2}H{sub 2}, HCN, and CO{sub 2}. This paper describes the sample and data processing and derives the detection rate of mid-infrared molecular emission as a function of stellar mass. The sample covers a range of spectral type from early M to A, and is supplemented by archival spectra of disks around A and B stars. It is drawn from a variety of nearby star-forming regions, including Ophiuchus, Lupus, and Chamaeleon. Spectra showing strong emission lines are used to identify which lines are the best tracers of various physical and chemical conditions within the disks. In total, we identify 22 T Tauri stars with strong mid-infrared H{sub 2}O emission. Integrated water line luminosities, where water vapor is detected, range from 5 x 10{sup -4} to 9 x 10{sup -3} L{sub sun}, likely making water the dominant line coolant of inner disk surfaces in classical T Tauri stars. None of the five transitional disks in the sample show detectable gaseous molecular emission with Spitzer upper limits at the 1% level in terms of line-to-continuum ratios (apart from H{sub 2}), but the sample is too small to conclude whether this is a general property of transitional disks. We find a strong dependence on detection rate with spectral type; no disks around our sample of 25 A and B stars were found to exhibit water emission, down to 1%-2% line-to-continuum ratios, in the mid-infrared, while more than half of disks around late-type stars (M-G) show sufficiently intense water emission to be detected by Spitzer, with a detection rate approaching 2/3 for disks around K stars. Some Herbig Ae/Be stars show tentative H{sub 2}O/OH emission features beyond 20 {mu}m at the 1%-2% level, however, and one of them shows CO{sub 2} in emission. We argue that the observed differences between T Tauri disks and Herbig Ae/Be disks are due to a difference in excitation and/or chemistry depending on spectral type and suggest that photochemistry may be playing an important role in the observable characteristics of mid-infrared molecular line emission from protoplanetary disks.

79 ASTRONOMY AND ASTROPHYSICS↗

The potential for detecting gamma-ray burst afterglows from population III stars with the next generation of infrared telescopes

We investigate the detectability of a proposed population of gamma-ray bursts (GRBs) from the collapse of Population III (Pop III) stars. The James Webb Space Telescope (JWST) and Space Infrared Telescope for Cosmology and Astrophysics (SPICA) will be able to observe the late time infrared afterglows. We have developed a new method to calculate their detectability, which takes into account the fundamental initial mass function and formation rates of Pop III stars, from which we find the temporal variability of the afterglows and ultimately the length of time JWST and SPICA can detect them. In the range of plausible Pop III GRB parameters, the afterglows are always detectable by these instruments during the isotropic emission, for a minimum of 55 days and a maximum of 3.7 yr. The average number of detectable afterglows will be 2.96× 10{sup –5} per SPICA field of view (FOV) and 2.78× 10{sup –6} per JWST FOV. These are lower limits, using a pessimistic estimate of Pop III star formation. An optimal observing strategy with SPICA could identify a candidate orphan afterglow in ∼1.3 yr, with a 90% probability of confirmation with further detailed observations. A beamed GRB will align with the FOV of the planned GRB detector Energetic X-ray Imaging Survey Telescope once every 9 yr. Pop III GRBs will be more easily detected by their isotropic emissions (i.e., orphan afterglows) rather than by their prompt emissions.

79 ASTRONOMY AND ASTROPHYSICS↗