The ATLAS Fast TracKer system

The ATLAS Fast TracKer (FTK) was designed to provide full tracking for the ATLAS high-level trigger by using pattern recognition based on Associative Memory (AM) chips and fitting in high-speed field programmable gate arrays. The tracks found by the FTK are based on inputs from all modules of the pixel and silicon microstrip trackers. The as-built FTK system and components are described, as is the online software used to control them while running in the ATLAS data acquisition system. Also described is the simulation of the FTK hardware and the optimization of the AM pattern banks. An optimization for long-lived particles with large impact parameter values is included. A test of the FTK system with the data playback facility that allowed the FTK to be commissioned during the shutdown between Run 2 and Run 3 of the LHC is reported. The resulting tracks from part of the FTK system covering a limited $\eta$-$\phi$ region of the detector are compared with the output from the FTK simulation. It is shown that FTK performance is in good agreement with the simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation, Refurbishment, and Characterization of Fast Neutron Scintillators for the TREAT Fuel Motion Monitoring System

This paper details work being performed at the Idaho National Laboratory (INL) to evaluate, refurbish, and characterize proton-recoil scintillation (PRS) detectors utilized in a 360 channel array for the measurement of fast neutrons in a standalone system historically called a hodoscope located in the Transient Reactor Test Facility (TREAT). The TREAT hodoscope serves as the primary Fuel Motion Monitoring System for documenting real time fuel displacement during transient experiments. The detectors in the hodoscope have stood dormant for over 20 years and significant degradation must be addressed before the system can be brought back to operational status. The refurbishment process begins by decoupling the PRS from their matched photo multiplier tubes (PMTs) and treating the PRS with ethanol. This process cleans the surfaces, removing paint and legacy labels/ markings. During this procedure many physical variations can be observed. After cleaning, the PRS are physically measured using a digital caliper and the dimensions documented. Following this, a well-controlled 280nm LED light source is used to stimulate the PRS to produce an emission spectrum inside an integration sphere. This emission spectrum is then measured using a UV enhanced optical spectrometer. Spectral measurements are recorded from 185 nm to 580 nm in 0.4 nm steps. The PRS are then lightly sanded on the non-PMT mating surfaces and painted with commercially available reflective paint. A final emission spectrum is recorded for each PRS after painting.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

System and method for adaptive optical tracking with selectable tracking modes

The present disclosure relates to an adaptive, free-space optical system. The system may have a controller and a digital micromirror (DMM) array responsive to the controller. The digital micromirror may include a plurality of independently controllable micromirror elements forming a receiver for receiving optical signals from an environmental scene. At least two of the plurality of independently controllable micromirror elements are steerable in different directions to receive optical signals emanating from two or more locations within the environmental scene. A beam steering subsystem forms a portion of the micromirror array and is in communication with the controller for receiving control signals from the controller. A detector is used to receive an incoming free space optical signal imaged by at least one of the micromirror elements.

Panas, Robert Matthew↗

Regolith Volatile Characterization (RVC) in RESOLVE

Resource investigation in the lunar poles is of importance to the potential impact of in-situ resource utilization (ISRU). The RESOLVE project developed a payload to investigate the permanently shadowed areas of the lunar poles and demonstrate ISRU technology. As a part of the RESOLVE project, the regolith volatile characterization (RVC) subsystem was designed to examine the release of volatiles from sample cores. The test sample was heated in the reactor to release the volatiles where they were analyzed with gas chromatography. Subsequently, the volatile sample was introduced into the lunar water resource demonstration (LWRD) subsystem where the released hydrogen and water were selectively captured. The objective of the Regolith Volatile Characterization (RVC) subsystem was to heat the crushed core sample and determine the desorption of volatile species of interest. The RVC subsystem encompasses the reactor and the system for volatile analysis. The system was designed to analyze H2, He, CO, CO2, N2, 02, CH4, H2S and H2O. The GC chosen for this work is a Siemens MicroSAM process GC with 3 columns and 8 TCD detectors. Neon was chosen as the carrier gas to enhance the analysis of hydrogen and helium.The limit of detection for the gases is approx.1000ppm for H2, CO. CO2 , N2, O2 and H2 S. The limit of detection for CH4 is approx.4000ppm and the water limit of detection is -10000 ppm with a sample analysis time of 2-3 minutes. These values (with the exception of water and H2S) were determined by dilution of a six gas mixture from Scott Gas (5% CO2, CO, O2, N2, 4% CH4 and H2) using mass flow controllers (MFC5). Water was calibrated at low levels using an in house relative humidity (RH) generator. H 2S and high concentrations of H2 were calibrated by diluting a pure stream of gas with MFCs. Higher concentrations of N2 and 02 were calibrated using Air again diluting with MFCs. There were three modification goals for the GC in EBU2 that would allow this process GC to be used in the field demo for RESOLVE. The first modification was to decrease the weight associated with the GC, this included eliminating the explosion proof case (Figure 1) and replacing it with a lightweight case as well as using an on board COPV tank for the neon carrier gas. The next goal was to add a second oven for the molecular sieve column to allow for dual temperature control during GC operation; the separation of hydrogen and helium is optimum at lower temperatures while the water analysis required higher temperatures creating a competing design requirement. The second oven also allows a lower limit of detection for water quantification and avoids the possibility of water condensing in the GC which could ruin the column characteristics. The final goal was to modify the column arrangement to optimize the system for our specific application. Figure 2 shows the internal details of the module optimized optimized for our field application. The modifications and performance of the gas analysis system will be discussed in detail.

Captain, Janine↗

Development of a soft-X ray detector for energy resolved 2D imaging by means of a Gas Pixel Detector with highly integrated microelectronics

Soft-X ray 2-D imaging on ITER is not considered yet. We propose a new approach, based on a gas detector with a gas electron multiplier (GEM) as amplifying structure and with a two-dimensional readout fully integrated with the front end electronics, through an ASIC developed on purpose. The concept has been already tested by means of a prototype, with 128 pixels, carried out in Frascati in collaboration with INFN-Pisa and tested on FTU in 2001 and NSTX in 2002-2004. Thanks to the photon counting mode, it provides 2-D imaging with high time resolution (sub millisecond), high sensitivity and signal to noise ratio. Its capability of energy discrimination allows the acquisition of pictures in X-ray energy bands or to perform a spectral scan in the full energy interval. We propose the realisation of such kind a detector with a readout microchip (ASIC) equipped with 105600 hexagonal pixels arranged at 70 {mu}m pitch in a 300x352 honeycomb matrix, corresponding to an active area of 2.1x2.1 cm{sup 2}, with a pixel density of 240 pixels/ mm{sup 2}. Each pixel is connected to a charge sensitive amplifier followed by a discriminator of pulse amplitude and counter. The chip integrates more than 16.5 million transistors and it is subdivided in 64 identical clusters, to be read independently each other. An important part of the work will be also the design of the whole detector to fulfil all the constraints and requirements as plasma diagnostic in a tokamak machine. Since the detector has high and controllable intrinsic gain, it works well even at very low photon energy, ranging from 0.2 keV to 10 keV (X-VUV region). This range appears therefore particularly suitable for ITER to monitor the outer part of the plasma. In particular pedestal physics, edge modes, localization and effects of additional heating, boundary plasma control etc. The capability of this proposed detector to work in this energy range is further valuable because solid state detectors are not favorite at low energy because of the lack of intrinsic gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A data acquisition system for longitudinal beam properties in a rapid cycling synchrotron

A longitudinal beam properties, data acquisition system has been commissioned to operate in the Fermilab booster ring. This system captures real time information including beam synchronous phase, bunch length, and coupled bunch instability amplitudes as the beam is accelerated from 400 MeV to 8 GeV in 33 ms. The system uses an off-the-shelf Tektronix oscilloscope running Labview software and a synchronous pulse generator. This paper describes the hardware configuration and the software configuration used to optimize the data processing rate. The Fermilab Booster is currently pushed to its intensity limit due to the high demand from different experiments for protons. This will continue into the era of the intensity frontier. While intensity is the most critical parameter, emittance must be controlled as well. Longitudinal emittance is an important parameter for optimizing the slip stacking process in the Main Injector. Longitudinal instabilities can spoil the emittance, so it is important to monitor bunch lengths and bunch phase oscillations in the Booster. The Booster presents a special challenge when it comes to measuring beam properties. The acceleration ramp is short (33ms), and the RF frequency varies from 38-52.8 MHz. Standard instrumentation like spectrum analyzers and network analyzers cannot effectively measure beam properties, because they cannot track the changing frequencies. Early instrumentation involved a series of tracking oscillators, mixers, and diode detectors that would require vigilant calibration. There was a demand for a more robust means of gathering beam parameters.

43 PARTICLE ACCELERATORS↗

Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance

Purpose: Monte Carlo simulations play a vital role in the understanding of the fundamental limitations, design, and optimization of existing and emerging medical imaging systems. Efforts in this area have resulted in the development of a wide variety of open-source software packages. One such package, hybridMANTIS, uses a novel hybrid concept to model indirect scintillator detectors by balancing the computational load using dual CPU and graphics processing unit (GPU) processors, obtaining computational efficiency with reasonable accuracy. In this work, the authors describe two open-source visualization interfaces, webMANTIS and visualMANTIS to facilitate the setup of computational experiments via hybridMANTIS. Methods: The visualization tools visualMANTIS and webMANTIS enable the user to control simulation properties through a user interface. In the case of webMANTIS, control via a web browser allows access through mobile devices such as smartphones or tablets. webMANTIS acts as a server back-end and communicates with an NVIDIA GPU computing cluster that can support multiuser environments where users can execute different experiments in parallel. Results: The output consists of point response and pulse-height spectrum, and optical transport statistics generated by hybridMANTIS. The users can download the output images and statistics through a zip file for future reference. In addition, webMANTIS provides a visualization window that displays a few selected optical photon path as they get transported through the detector columns and allows the user to trace the history of the optical photons. Conclusions: The visualization tools visualMANTIS and webMANTIS provide features such as on the fly generation of pulse-height spectra and response functions for microcolumnar x-ray imagers while allowing users to save simulation parameters and results from prior experiments. The graphical interfaces simplify the simulation setup and allow the user to go directly from specifying input parameters to receiving visual feedback for the model predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm{sup 2} (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam line for top-to-bottom exposures. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Programmer-guided reliability for extreme-scale applications

We present “programmer-guided reliability” (PGR) as a systematic conceptual approach to address the expected rise in soft errors in coming extreme-scale systems at the application level. The approach involves instrumentation of the application with code to detect data corruption errors. The location and nature of these error detectors are at the discretion of the programmer, who uses their knowledge and experience with the problem domain, the application, the solution algorithms, etc., to determine the most vulnerable areas of the code and the most appropriate ways to detect data corruption. To illustrate the approach, we provide examples of error detectors from four different benchmark-scale applications. We also describe a simple control framework that allows for runtime configuration of the error detectors without recompilation of the application, as well as dynamic reconfiguration during the execution of the application. Lastly, we discuss a number of future directions building on the basic PGR approach, including the incorporation of some general error detectors into the programming environment in order to make them more easily usable by the programmer.

97 MATHEMATICS AND COMPUTING↗

Online and Offline Analytical Techniques to Quantify Chloride Salts

This report serves as the deliverable for Milestone- M3FT-26AN080502017: Summary of Accomplishments for Online and Offline Analytical Qualification of Chloride Fuel Salts. The qualification of chloride fuel salts is a critical challenge for the development and deployment of molten salt reactors (MSRs), requiring precise control and verification of chemical and isotopic composition to ensure predictable neutronics, manageable radiological behavior, and safe plant operation. Currently, there is no universally accepted standard for fuel salt qualification, particularly for chloride-based systems, which underscores the need for robust, science-based analytical methodologies. This report presents a comprehensive evaluation of both online and offline techniques for quantifying chloride fuel salts, including multielectrode array voltammetry, differential thermal analysis (DTA) probes, inert gas fusion (IGF) analyzers, and gamma spectrometry using the Mirion NAIS-2x2 NaI(Tl) detector. The integration of these methods enables real-time monitoring of actinide concentrations, redox state, and thermophysical properties, as well as high-precision measurement of impurities and isotopic composition. The acquisition of advanced instruments such as the Bruker Leonardo G6 for IGF and the Mirion NaI detector enhances analytical capabilities, supporting the establishment of operational envelopes and impurity thresholds. These approaches provide essential data for neutronic impact evaluation, feedstock documentation, and compliance with nuclear safety standards. The methodologies developed and validated in this report lay the groundwork for future standardized protocols, bridging the gap between laboratory research and commercial reactor operation, and advancing the safe and efficient deployment of chloride-fueled MSRs.

Polke, Amber↗

ATCA/muTCA for Physics

ATCA/{mu}TCA platforms are attractive because of the modern serial link architecture, high availability features and many packaging options. Less-demanding availability applications can be met economically by scaling back speed and redundancy. The ATCA specification was originally targeted for the Telecom industry but has gained recently a much wider user audience. The purpose of this paper is to report on present hardware and software R and D efforts where ATCA and {mu}TCA are planned, already being used or in development using selected examples for accelerator and detectors in the Physics community. It will present also the status of a proposal for physics extensions to ATCA/{mu}TCA specifications to promote inter-operability of laboratory and industry designs for physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling and Control Using Stochastic Distribution Control Theory for Intersection Traffic Flow

In this work, we investigated stochastic distribution control theory-based traffic signal optimization to achieve a smooth and uniform flow of vehicles through signalized intersections. In this context, the static and linear dynamic stochastic distribution models were developed to express the relationship between the signal timing and the traffic queue length together with its probability density function. Two stochastic distribution control algorithms were designed to control the signal timing at intersections such that the probability density function of the traffic queue of each intersection road segment is made as narrow and as small as possible. Also, a recursive input-output traffic queue estimation model was proposed, which is data-driven and dynamic in nature, to calculate real-time traffic queue length using traffic signal timings and loop-detector data. The control algorithms were evaluated for a one-signal corridor, two-signal corridor, and 2 x 2 network of signalized intersections. MATLAB simulation examples are provided to demonstrate the use of the proposed algorithms and comparison to the existing widely-used semi-actuated control has been made. Desired results were obtained.

97 MATHEMATICS AND COMPUTING↗

Estimation of Arrivals on Green at Signalized Intersections Using Stop-Bar Video Detection

Across the world, traffic congestion is increasing with alarming rapidity. Traffic signal control effectiveness, in coordinated networks, is often investigated in relation to the type of vehicle arrivals at the signalized intersections. Recently, several transportation agencies have switched from traditional loop detectors to video detection. When video cameras are accompanied by computer vision, one can extract more information about traffic “dynamics” than by using traditional inductive loop detectors. Collecting arrival times of multiple vehicles after the first arrival at the stop-bar detector might be challenging when using inductive loop detectors (since after the first arrival, detector status is always occupied). However, emerging video detection systems allow tracking of each vehicle’s entrance time in the detection zone, departure time from the detection zone, and the type of vehicle. This information can be used to estimate vehicular arrival and departure times, which then can be fed into machine learning algorithms to estimate arrivals on green (AOG). However, such research ideas have not been documented so far. Thus, this paper presents an estimation model for AOG, which was developed using multigene genetic programming. A robust experimental dataset was collected from a highly calibrated and validated microsimulation model of an 11-intersection corridor in Chattanooga, TN. The results of the model’s performance analysis showed the high accuracy of the training-, testing-, and validation datasets. The practical benefit of this model is that it can be applied to estimate arrival types at intersections where only stop-bar video detection exists.

Engineering↗

Code regenerative clean-up loop transponder for a mu-type ranging system

A loop transponder for regenerating the code of a mu type ranging system is disclosed. It includes a phase locked loop, a code generator, and a loop detector. The function of the phase locked loop is to provide phase lock between a received component wk of the range signal and a replica rafter wk of the received component, provided by the code generator. The code generator also provides a replica of the next component rafter w(w+1). The loop detector responds to wk rafler wk and rafter w(k+1) to determine when the next component w(k+1) is received and controls the code generator to supply w(k+1) to the phase locked loop and to generate a replica rafter w(k+2) of the next component.

Hurd, W. J.↗

Development of an advanced combined iodine dispenser/detector

Injection of iodine into water is widely used to control microbial growth. An entirely automated device for I2 injection has been developed for spacecraft application. Transfer of I2 into the water from a concentrated form is controlled electrochemically via feedback from an integrated photometric I2 level detector. All components are contained within a package weighing only 1.23 kg (2.7 lb) dry, which occupies only 1213 cu cm (74 cu in) of space, and which has the capacity to iodinate 10,900 kg (24,000 lb) of water of 5 ppm. These features exceed design specifications. The device performed satisfactorily during extended testing at variable water flow rates and temperatures. Designed to meet specifications of the Shuttle Orbiter, the device will find application in the regenerative water systems of advanced spacecraft.

Lantz, J. B.↗

Active-Interrogation Measurements of Induced-Fission Neutrons from Low-Enriched Uranium

Protection and control of nuclear fuels is paramount for nuclear security and safeguards; therefore, it is important to develop fast and robust controlling mechanisms to ensure the safety of nuclear fuels. Through both passive- and active-interrogation methods we can use fast-neutron detection to perform real-time measurements of fission neutrons for process monitoring. Active interrogation allows us to use different ranges of incident neutron energy to probe for different isotopes of uranium. With fast-neutron detectors, such as organic liquid scintillation detectors, we can detect the induced-fission neutrons and photons and work towards quantifying a sample’s mass and enrichment. Using MCNPX-PoliMi, a system was designed to measure induced-fission neutrons from U-235 and U-238. Measurements were then performed in the summer of 2010 at the Joint Research Centre in Ispra, Italy. Fissions were induced with an associated particle D-T generator and an isotopic Am-Li source. The fission neutrons, as well as neutrons from (n, 2n) and (n, 3n) reactions, were measured with five 5” by 5” EJ-309 organic liquid scintillators. The D-T neutron generator was available as part of a measurement campaign in place by Padova University. The measurement and data-acquisition systems were developed at the University of Michigan utilizing a CAEN V1720 digitizer and pulse-shape discrimination algorithms to differentiate neutron and photon detections. Low-enriched uranium samples of varying mass and enrichment were interrogated. Acquired time-of-flight curves and cross-correlation curves are currently analyzed to draw relationships between detected neutrons and sample mass and enrichment. In the full paper, the promise of active-interrogation measurements and fast-neutron detection will be assessed through the example of this proof-of-concept measurement campaign. Additionally, MCNPX-PoliMi simulation results will be compared to the measured data to validate the MCNPX-PoliMi code when used for active-interrogation simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of Nuclear Material Accounting Data and Process Monitoring Data for Improvement on Detection Probability in Safeguarding Electrochemical Processing Facilities (Final Technical Report)

The KAERI advanced spent fuel conditioning process (ACP) process is a critical component of the US- South Korean nuclear cooperation and the following “123 Agreement.” Its development has received considerable attention in both countries. The ACP is an electrochemical processing (pyroprocessing) that recycles over 96% of the used nuclear fuel (UNF). It is also intrinsically proliferation-resistant in theory. In normal operation, the U/TRU product is very hot radiologically. In addition, the Cm provides a high level of spontaneous neutrons, making the product unsuitable for weapon use. However, as pointed in some study, “the need for safeguards to protect against the diversion and misuse of separated plutonium applies essentially equally to all grades of plutonium.” As pointed by many studies, the well-established traditional Nuclear Material Accounting (NMA) approach cannot be directly applied to electrochemical processing because of the lack of an input accountability tank, the non-continuous material flow, and the unsatisfactory level of confidence in sampling methods. Therefore, nuclear safeguards remain a grand challenge in the developing of commercial electrochemical separations facilities, especially around the heart of such facilities, the electrorefiner (ER) systems. In contrast to NMA data, process monitoring (PM) data is normally an indirect measurement of the SNM and is acquired much more frequently. In a broad sense, PM includes monitoring by various types of equipment, e.g. radiation detectors, cameras, voltage, current sensors. Because it is already being collected by the operator, the additional cost to safeguards is low. It has long been believed that PM data can supplement NMA data and help improve safeguards, although the benefits are hard to quantify. The U.S. DOE’s Material Protection, Accounting, and Control Technology (MPACT) campaign has made substantial investments into innovative PM sensor technology and predictive model development for real- or near real-time measurement and prediction of molten salt density and level, salt composition and actinide concentration especially Pu, the cell voltage, and the cell current to supplement traditional NMA. For aqueous-based reprocessing facilities, it is reported that PM, integrated with traditional NMA, have a high detection probability for specific diversions. For electrochemical reprocessing, preliminary studies have shown that PM data can support traditional NMA in various ways by providing a basis to estimate some of the in-processing nuclear material inventories. Despite early success, further studies on fusion of PM data and NMA data are still needed, which is the goal of this proposed work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.