Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Computational Assessment of the Impact of Gamma-ray Detector Material Properties on Spectroscopic Performance

Abstract Pacific Northwest National Laboratory (PNNL) is performing a computational assessment of the impact of several important gamma-ray detector material properties (e.g. energy resolution and intrinsic detection efficiency) on the scenario-specific spectroscopic performance of these materials. The research approach combines 3D radiation transport calculations, detector response modeling, and spectroscopic analysis of simulated energy deposition spectra to map the functional dependence of detection performance on the underlying material properties. This assessment is intended to help guide formulation of performance goals for new detector materials within the context of materials discovery programs, with an emphasis on applications in the threat reduction, nonproliferation, and safeguards/ verification user communities. The research results will also provide guidance to the gamma-ray sensor design community in estimating relative spectroscopic performance merits of candidate materials for novel or notional detectors.

Jordan, David V.↗

Design and Calibration of Autonomous Coherent Doppler Lidar for Space Missions

Developed a new algorithm for the simulation of three dimensional homogeneous turbulent velocity fields. For typical atmospheric conditions it is impossible to produce a simulated velocity field that simultaneously satisfy a given spatial correlation and the corresponding spatial spectrum because of spectral aliasing. The new algorithms produce a turbulent velocity field which has accurate spatial correlations which is required for performance predictions from space-based systems. Developed a new algorithm for extracting the spatial statistics of the atmospheric velocity field using coherent Doppler lidar. The performance of the algorithm was compared with past methods and the new algorithm produces useful results for space-based data, which was not possible before. Developed new methods for verification of the errors in ground-based and space-based Doppler lidar wind measurements. These new methods do not require independent in situ data. This is an important issue for the verification of space-based Doppler lidar measurements of the global wind field. The performance of the new algorithm was compared with past results for both space-based and ground-based operation. The new algorithm has the best performance and is the only algorithm that performed satisfactory for spacebased operation. The performance of coherent Doppler lidar for a space missions with various scanning geometries was determined using computer simulation which contained the effects of random instrumental velocity errors, wind shear, wind variability along the range-gate and from shot-to-shot, and random variations in atmospheric aerosol backscatter over the measurement volume. The bias in the velocity estimates was small and the accuracy in the is typically less than 0.5 m/s for high signal conditions. For a large number of shot per velocity estimate, the threshold signal level for acceptable estimates is proportional to the number of shots to the minus one half power. This agrees with previous results determined for ground-based measurements. The use of multi-element optical detectors for autonomous operation of coherent Doppler lidar was shown to be a very promising technique. Optimal detector geometries were determined by computer simulation of performance: for ground-based testing with a fixed calibration target and for space-based operation using the random surface returns. The effects of refractive turbulence on ground-based calibration of coherent Doppler lidar was determined by computer simulations and compared with theoretical predictions. New techniques were required to correctly predict performance for the focused beam geometry commonly used for verification of space-based operation. An improved velocity estimator was evaluated for space-based applications were signal shot measurements are used to produce vector wind measurements. This permits more accurate measurements when the signal level is not known a priori or not available from multiple shot measurements. The average Doppler lidar signal spectrum including the effects of velocity turbulence was derived and calculated. This permits new estimation algorithms for turbulence based on spectral estimates. In situ atmospheric measurements were conducted and analyzed using an instrumented kite-platform. This work helps provide the required in situ data for verification of Doppler lidar velocity statistics.

Frehlich, Rod G.↗

Development of shashlik electromagnetic calorimeter prototype for SoLID

A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. In conclusion, a prototype of that module will be tested soon with an electron beam at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameter Estimation for Compact Binaries with Ground-Based Gravitational-Wave Observations Using the LALInference

The Advanced LIGO and Advanced Virgo gravitational wave (GW) detectors will begin operation in the coming years, with compact binary coalescence events a likely source for the first detections. The gravitational waveforms emitted directly encode information about the sources, including the masses and spins of the compact objects. Recovering the physical parameters of the sources from the GW observations is a key analysis task. This work describes the LALInference software library for Bayesian parameter estimation of compact binary signals, which builds on several previous methods to provide a well-tested toolkit which has already been used for several studies. We show that our implementation is able to correctly recover the parameters of compact binary signals from simulated data from the advanced GW detectors. We demonstrate this with a detailed comparison on three compact binary systems: a binary neutron star (BNS), a neutron star - black hole binary (NSBH) and a binary black hole (BBH), where we show a cross-comparison of results obtained using three independent sampling algorithms. These systems were analysed with non-spinning, aligned spin and generic spin configurations respectively, showing that consistent results can be obtained even with the full 15-dimensional parameter space of the generic spin configurations. We also demonstrate statistically that the Bayesian credible intervals we recover correspond to frequentist confidence intervals under correct prior assumptions by analysing a set of 100 signals drawn from the prior. We discuss the computational cost of these algorithms, and describe the general and problem-specific sampling techniques we have used to improve the efficiency of sampling the compact binary coalescence (CBC) parameter space.

gravitational wave↗

Enhancing Neutrino Event Reconstruction with Pixel-Based 3D Readout for Liquid Argon Time Projection Chambers

In this paper we explore the potential improvements in neutrino event reconstruction that a 3D pixelated readout could offer over a 2D projective wire readout for liquid argon time projection chambers. We simulate and study events in two generic, idealized detector configurations for these two designs, classifying events in each sample with deep convolutional neural networks to compare the best 2D results to the best 3D results. In almost all cases we find that the 3D readout provides better reconstruction efficiency and purity than the 2D projective wire readout, with the advantages of 3D being particularly evident in more complex topologies, such as electron neutrino charged current events. We conclude that the use of a 3D pixelated detector could significantly enhance the reach and impact of future liquid argon TPC experiments physics program, such as DUNE.

Adams, C↗

Correlated Production and Analog Transport of Fission Neutrons and Photons Using Fission Models FREYA, FIFRELIN, and the Monte Carlo Code TRIPOLI-4

Fission modeling in general-purpose Monte Carlo transport codes often relies on average nuclear data provided by the international evaluation libraries. As such, only average fission multiplicities are available and correlations between fission neutrons and photons are missing. Whereas uncorrelated fission physics is usually sufficient for standard reactor core and radiation shielding calculations, correlated fission secondaries are required for specialized nuclear instrumentation and detector modeling. For coincidence counting detector optimization for instance, the precise simulation of fission neutrons and photons that remain correlated in time from birth to detection is essential. New developments were recently integrated into the Monte Carlo transport code TRIPOLI-4 to model fission physics more precisely, the purpose being to access event-by-event fission events from two different fission models: Fission Reaction Event Yield Algorithm (FREYA) and Fission Fragment Evaporation Leading to an Investigation of Nuclear Data (FIFRELIN). TRIPOLI-4 simulations can now be performed, either by connecting via an application programming interface to the Lawrence Livermore National Laboratory fission library including FREYA, or by reading the external fission event data files produced by FIFRELIN beforehand. These new capabilities enable us to easily compare results from the Monte Carlo transport calculations using the two fission models in a nuclear instrumentation application. In the first part of this paper, the broad underlying principles of the two fission models are recalled. We then present the experimental measurements of neutron angular correlations for 252 Cf(sf) and 240 Pu(sf). The correlations were measured for several neutron kinetic energy thresholds. In the latter part of this paper, simulation results are compared with the experimental data. Spontaneous fissions in 252 Cf and 240 Pu are modeled by FREYA or FIFRELIN. Emitted neutrons and photons are subsequently transported to an array of scintillators by TRIPOLI-4 in the analog mode to preserve their correlations. Angular correlations between fission neutrons obtained independently from these TRIPOLI-4 simulations, using either FREYA or FIFRELIN, are compared with the experimental results. In conclusion, for 240 Pu(sf), the measured correlations were used to tune one of the FREYA model parameters. Similarly, different sets of parameters have been tested in FIFRELIN to try to improve the agreement with the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. The new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the Advantages and Limitations of Stationary Imaging Fourier Transform Spectrometer

New developments in infrared sensor technology have potentially made possible a new space-based system which can measure far-infrared radiation at lower costs (mass, power and expense). The Stationary Imaging Fourier Transform Spectrometer (SIFTS) proposed by NASA Langley Research Center, makes use of new detector array technology. A mathematical model which simulates resolution and spectral range relationships has been developed for analyzing the utility of such a radically new approach to spectroscopy. Calculations with this forward model emulate the effects of a detector array on the ability to retrieve accurate spectral features. Initial computations indicate significant attenuation at high wavenumbers.

Beecken, Brian P.↗

Beam test evaluation of electromagnetic calorimeter modules made from proton-damaged PbWO 4 crystals

The performance of electromagnetic calorimeter modules made of proton-irradiated PbWO 4 crystals has been studied in beam tests. The modules, similar to those used in the Endcaps of the CMS electromagnetic calorimeter (ECAL), were formed from 5×5 matrices of PbWO 4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between 2.1 × 10 13 and 1.3 × 10 14 cm –2 . These correspond to the predicted charged-hadron fluences in the ECAL Endcaps at pseudorapidity η = 2.6 after about 500 fb –1 and 3000 fb –1 respectively, corresponding to the end of the LHC and High Luminosity LHC operation periods. The irradiated crystals have a lower light transmission for wavelengths corresponding to the scintillation light, and a correspondingly reduced light output. A comparison with four crystals irradiated in situ in CMS showed no significant rate dependence of hadron-induced damage. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The latter is interpreted, through comparison with simulation, as a side-effect of the degradation in light transmission. In conclusion, the experimental results obtained can be used to estimate the long term performance of the CMS ECAL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Feynman Variance-To-Mean Measurements Using Measured and Simulated Data

Measured and simulated list-mode data from the NPOD detector system were compared for subcritical systems. Five BeRP ball configurations reflected by polyethylene are investigated in this work. The simulated data were calculated using the MCNP multiplication patch developed at LANL. In addition to comparing the moments of the counting distributions, a full analysis was conducted to infer the multiplication of each system using both the Hansen-Dowdy and Hage-Cifarelli formulisms. Several of the parameters that are input into these methods were also varied to determine their affect on the system multiplication. The main parameters investigated included the system source strength, reflector transmission, and the average number of neutrons released per 239 Pu fission ($\nu$). It is shown that when comparing the measured and simulated data while using the same method and parameters the inferred multiplication values agree within 5%. The measured and simulated multiplication values differ more as the reflector thickness increases. The moments for the simulated data were higher than the measured data for all of the configurations and also disagreed more as the reflector thickness increased. The analysis method and parameters used can lead to a large spread of inferred multiplication values. In the future more configurations will be analyzed in a similar manner and a detailed uncertainty analysis will be performed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Measured and Simulated List-Mode Data for Subcritical Systems

Measured and simulated list-mode data from the NPOD detector system were compared for subcritical systems. Five BeRP ball configurations reflected by polyethylene are investigated in this work. The simulated data were calculated using the MCNP list-mode patch developed at LANL. In addition to comparing the moments of the counting distributions, a full analysis was conducted to infer the multiplication of each system using both the Hansen-Dowdy and Hage-Cifarelli formulisms of the Feynman Variance-to-Mean Method. Several of the parameters that are input into these methods were also varied to determine their affect on the system multiplication. The main parameters investigated included the system source strength and reflector transmission. It is shown that when comparing the measured and simulated data while using the same method and parameters the multiplication values agree within 5.5%. The measured and simulated multiplication values differ more as the reflector thickness increases. The moments for the simulated data were higher than the measured data for all of the configurations and also disagreed more as the reflector thickness increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Fukushima Daiichi reactors with muons

A study of imaging the Fukushima Daiichi reactors with cosmic-ray muons to assess the damage to the reactors is presented. Muon scattering imaging has high sensitivity for detecting uranium fuel and debris even through thick concrete walls and a reactor pressure vessel. Technical demonstrations using a reactor mockup, detector radiation test at Fukushima Daiichi, and simulation studies have been carried out. These studies establish feasibility for the reactor imaging. A few months of measurement will reveal the spatial distribution of the reactor fuel. The muon scattering technique would be the best and probably the only way for Fukushima Daiichi to make this determination in the near future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data-driven precision determination of the material budget in ALICE

The knowledge of the material budget with a high precision is fundamental for measurements of direct photon production using the photon conversion method due to its direct impact on the total systematic uncertainty. Moreover, it influences many aspects of the charged-particle reconstruction performance. In this article, two procedures to determine data-driven corrections to the material-budget description in ALICE simulation software are developed. One is based on the precise knowledge of the gas composition in the Time Projection Chamber. The other is based on the robustness of the ratio between the produced number of photons and charged particles, to a large extent due to the approximate isospin symmetry in the number of produced neutral and charged pions. Both methods are applied to ALICE data allowing for a reduction of the overall material budget systematic uncertainty from 4.5% down to 2.5%. Using these methods, a locally correct material budget is also achieved. The two proposed methods are generic and can be applied to any experiment in a similar fashion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-201-02: Quantitative Small-Animal SPECT Without Scatter Correction Using High-Purity Germanium Detectors

Purpose: To evaluate the impact of the exceptional energy resolution of germanium detectors for preclinical SPECT in comparison to conventional detectors. Methods: A cylindrical water phantom was created in GATE with a spherical Tc-99m source in the center. Sixty-four projections over 360 degrees using a pinhole collimator were simulated. The same phantom was simulated using air instead of water to establish the true reconstructed voxel intensity without attenuation. Attenuation correction based on the Chang method was performed on MLEM reconstructed images from the water phantom to determine a quantitative measure of the effectiveness of the attenuation correction. Similarly, a NEMA phantom was simulated, and the effectiveness of the attenuation correction was evaluated. Both simulations were carried out using both NaI detectors with an energy resolution of 10% FWHM and Ge detectors with an energy resolution of 1%. Results: Analysis shows that attenuation correction without scatter correction using germanium detectors can reconstruct a small spherical source to within 3.5%. Scatter analysis showed that for standard sized objects in a preclinical scanner, a NaI detector has a scatter-to-primary ratio between 7% and 12.5% compared to between 0.8% and 1.5% for a Ge detector. Preliminary results from line profiles through the NEMA phantom suggest that applying attenuation correction without scatter correction provides acceptable results for the Ge detectors but overestimates the phantom activity using NaI detectors. Due to the decreased scatter, we believe that the spillover ratio for the air and water cylinders in the NEMA phantom will be lower using germanium detectors compared to NaI detectors. Conclusion: This work indicates that the superior energy resolution of germanium detectors allows for less scattered photons to be included within the energy window compared to traditional SPECT detectors. This may allow for quantitative SPECT without implementing scatter correction, reducing uncertainties introduced by scatter correction algorithms. Funding provided by NIH/NIBIB grant R01EB013677; Todd Peterson, Ph.D., has had a research contract with PHDs Co., Knoxville, TN.

07 ISOTOPE AND RADIATION SOURCES↗

Charge Transport and Space-Charge Formation in Cd 1 - x Zn x Te 1 - y Se y Radiation Detectors

The electron- and hole-transport properties in cadmium zinc telluride selenide (CZTS) crystals are studied using a laser-induced transient-current technique with pulsed and dc bias. The internal electric field profile and velocity of surface recombination are determined by Monte Carlo simulations of electron and hole transient currents combined with a numerical solution of the drift-diffusion equation coupled with Poisson’s equation. Electron and hole drift mobilities of μe = 830 cm 2 /Vs and μh = 40 cm 2 /Vs, respectively, are determined. We also develop a simple technique for evaluating surface recombination directly from measured current waveforms without the need for numerical simulation. The good quality of the prepared detector at pulsed bias, with electron- and hole-mobility-lifetime products of (μτ)e = 1.9 × 10 -3 cm 2 /V and (μτ)h = 1.4 × 10 -4 cm 2 /V, respectively, are observed. The formation of a positive space charge, originating from hole injection combined with a recombination level, is found. We observe a significant position dependence of the lifetime of electrons and holes in dc bias due to hole injection. The experiment is successfully fitted by a simple model dominated by a single deep recombination level with an energy of E t =E C -0.73eV; concentration of 7.3 × 10 11 cm -3 ; and electron- and hole-capture cross sections of 3.5 × 10 -14 cm 2 and 6.5 × 10 -14 cm 2 , respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-328: The Volume Effect Correction of Probe-Type Dosimetric Detectors Derived From the Convolution Model

Purpose: To derive and introduce a new correction factor kV, the “volume effect correction factor”, that accounts for not only the dose averaging over the detector's sensitive volume but also the secondary electron generation and transport inclusive of the disturbance of the field of secondary electrons within the detector. Materials and Methods: Mathematical convolutions and Fourier's convolution theorem have been used. Monte Carlo simulations of photon pencil beams were performed using EGSnrc. Detector constructions were adapted from manufacturers' information. Results: For the calculation of kV, the three basic convolution kernels have to be taken into account: the dose deposition kernel KD(x) (fluence to dose), the photon fluence response kernel KM(x) (photon fluence to detector signal) and the “dose response kernel” K(x) (dose to detector signal). K(x) is calculated from FT[K(x)] = [1/sqrt(2”)]FT[KM(x)]/FT[KD(x)], where the magnitude of kV(x) can be thereby calculated for arbitrary photon beam profiles and the areanormalized K(x). Conclusions: n order to take into account for the dimensions of dosimetric detectors in narrow photon beams, the “volume effect correction factor” kV has been introduced into the fundamental equation of probe-type dosimetry, and the convolution method has proven to be a method for the derivation of its numerical values. For narrow photon beams, whose width is comparable to the secondary electron ranges, kV can reach very high values, but it can be shown that the signals of small diamond detectors are well representing the absorbed dose to water averaged over the detector volume.

07 ISOTOPE AND RADIATION SOURCES↗

Teledyne H1RG, H2RG, and H4RG Noise Generator

This paper describes the near-infrared detector system noise generator (NG) that we wrote for the James Webb Space Telescope (JWST) Near Infrared Spectrograph (NIRSpec). NG simulates many important noise components including; (1) white "read noise", (2) residual bias drifts, (3) pink 1/f noise, (4) alternating column noise, and (5) picture frame noise. By adjusting the input parameters, NG can simulate noise for Teledyne's H1RG, H2RG, and H4RG detectors with and without Teledyne's SIDECAR ASIC IR array controller. NG can be used as a starting point for simulating astronomical scenes by adding dark current, scattered light, and astronomical sources into the results from NG. NG is written in Python-3.4.

H2RG↗

Geant4 simulations of sampling and homogeneous hadronic calorimeters with dual readout for future colliders

Calorimeters with dual readout measure both scintillation and Cherenkov light produced in their active media. They offer improvements in energy resolution and, therefore, have become increasingly interesting due to the need for precision jet measurements at Higgs factories. Furthermore, this paper presents GEANT4 simulations of single-particle responses in sampling and homogeneous calorimeters, and demonstrates the effect of inclusion of Cherenkov light in the reconstruction of energies.

Detector modeling and simulations↗