Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Non-spectroscopic composition measurements of SrTiO 3 -La 0.7 Sr 0.3 MnO 3 multilayers using scanning convergent beam electron diffraction

The local atomic structure of a crystalline sample aligned along a zone axis can be probed with a focused electron probe, which produces a convergent beam electron diffraction pattern. The introduction of high speed direct electron detectors has allowed for experiments that can record a full diffraction pattern image at thousands of probe positions on a sample. By incoherently summing these patterns over crystalline unit cells, we demonstrate in this paper that in addition to crystal structure and thickness, we can also estimate the local composition of a perovskite superlattice sample. This is achieved by matching the summed patterns to a library of simulated diffraction patterns. Finally, this technique allows for atomic-scale chemical measurements without requiring a spectrometer or hardware aberration correction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multimode scanning X-ray diffraction microscopy for diamond anvil cell experiments

We have designed and implemented a new experimental system for fast mapping of crystal structures and other structural features of materials under high pressure at the High Pressure Collaborative Access Team, Sector 16 of the Advanced Photon Source. The system utilizes scanning X-ray diffraction microscopy (SXDM) and is optimized for use with diamond anvil cell devices. In SXDM, the X-ray diffraction (XRD) is collected in a forward scattering geometry from points on a two-dimensional grid by fly-scanning the sample with respect to a micro-focused X-ray beam. The recording of XRD is made during the continuous motion of the sample using a fast (millisecond) X-ray area detector in synchrony with the sample positioners, resulting in a highly efficient data collection for SXDM. A new computer program, X-ray Diffractive Imaging (XDI), has been developed with the SXDM system. The XDI program provides a graphical interface for constructing and displaying the SXDM images in several modes: (1) phase mapping based on structural information, (2) pressure visualization based on the equation of state, (3) microstructural features mapping based on peak shape parameters, and (4) grain size and preferred-orientation based on peak shape parameters. The XDI is a standalone program and can be generally used for displaying SXDM images. Two examples of iron and zirconium samples under high pressure are presented to demonstrate the applications of SXDM. Published under license by AIP Publishing.

47 OTHER INSTRUMENTATION↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Design and construction of a compact, high-repetition-rate ultrafast electron diffraction instrument

We present the design and performance of a compact ultrafast electron diffraction instrument. The diffractometer provides a means of examining time-resolved ultrafast dynamical properties of solids. The system’s utilization is discussed in terms of instrument parameters and diffraction data from selected condensed matter samples. Here, the difractometer’s performance is highlighted in terms of detection sensitivity, instrumental temporal resolution, and the electron beam transverse coherence length. Following specific details of the construction, we present a practical discussion of parameters such as repetition rate and provide advice on general construction approaches for laboratory-based, keV ultrafast electron diffractometers. In addition, design guidance for constructing a compact electron gun source that is well-suited for studying diffraction from hard condensed matter is given. A unique data acquisition scheme, utilizing high laser repetition rates, is presented.

47 OTHER INSTRUMENTATION↗

X-ray source characterization and sample heating on x-ray diffraction experiments at the National Ignition Facility

X-ray diffraction is a powerful measurement technique for determining material properties, and it is now possible to perform these experiments at pressures exceeding 1 TPa [Rygg et al., Rev. Sci. Instrum. 91, 043902 (2020)] at the National Ignition Facility (NIF). The x-ray source for these experiments is the quasi-monochromatic Heα emission from metal foils heated to multi-keV temperatures. A critical aspect for understanding the sample's thermodynamic state is the amount of heating caused by absorption of the probe x-rays. In this work, we characterize the performance of the Ge foil x-ray source over more than 60 NIF x-ray diffraction experiments. We use this information to constrain the level of diffraction sample heating from the x-ray source and discuss the impact on the thermodynamic state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A simple wire-coil resistive heater for high temperature radial x-ray diffraction in a diamond anvil cell

Diamond anvil cells are commonly used at synchrotron x-ray diffraction beamlines to study structural and thermoelastic properties of materials at high pressures. In a radial geometry, where the x-ray probe is oriented perpendicular to the axis of force, the deformation and strength of materials can be measured in situ. Because the anelastic and failure properties of materials depend strongly on temperature, many applications would benefit from the ability to measure high pressure radial diffraction in elevated and accurately controlled thermal environments. Previous work to introduce high temperature to radial diamond anvil cells has been largely limited to laser heating, with relatively scant efforts to resistively heat the sample. Here, we report a relatively straightforward adaptation of a simple wire coil heater, with in situ high-temperature radial diffraction performed on tungsten carbide up to 573 K at beamline 12.2.2 of the Advanced Light Source. In conclusion, the results demonstrate that the differential stress supported by WC decreases with increasing temperature: the differential stress on the basal (001) and pyramidal (101) planes decreased 6.6% and 5.5%, respectively, while the (100) plane only saw a 2.7% decrease, in agreement with previous studies.

Diamond anvil cells↗

Wide-aperture diffraction of unpolarised radiation in a system of two acousto-optic filters

Light diffraction is studied in two tandem acousto-optic cells filtering unpolarised radiation with a wide angular spectrum. It is shown that the side lobes of the ultrasonic radiation pattern of a piezoelectric transducer produce side diffraction intensity maxima at the output of the system consisting of two filters. Diffraction in paratellurite filters is studied experimentally at 1.06 {mu}m. (light modulation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional image edge enhancement in the two-phonon diffraction

We suggest using the two-phonon Bragg scattering regime for two-dimensional image edge enhancement by means of acousto-optic (AO) diffraction on a single sound wave. Image edge enhancement is demonstrated in the first diffraction order by using an AO cell made of the TeO{sub 2} single crystal. To explain this effect, a three-dimensional model of AO interaction is proposed, which takes into account the angular selectivity of diffraction both in the plane of Bragg scattering and in the plane orthogonal to it. (optical data processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral characteristics of multimode semiconductor lasers with a high-order surface diffraction grating

We have studied the spectral characteristics of multimode semiconductor lasers with high-order surface diffraction gratings based on asymmetric separate-confinement heterostructures grown by metalorganic vapour phase epitaxy (λ = 1070 nm). Experimental data demonstrate that, in the temperature range ±50 °C, the laser emission spectrum is ∼5 Å in width and contains a fine structure of longitudinal and transverse modes. A high-order (m = 15) surface diffraction grating is shown to ensure a temperature stability of the lasing spectrum dλ/dT = 0.9 Å K{sup -1} in this temperature range. From analysis of the fine structure of the lasing spectrum, we have evaluated the mode spacing and, thus, experimentally determined the effective length of the Bragg diffraction grating, which was ∼400 μm in our samples. (lasers)

36 MATERIALS SCIENCE↗

Quantum phase-sensitive diffraction and imaging using entangled photons

We propose a quantum diffraction imaging technique whereby one photon of an entangled pair is diffracted off a sample and detected in coincidence with its twin. The image is obtained by scanning the photon that did not interact with matter. We show that when a dynamical quantum system interacts with an external field, the phase information is imprinted in the state of the field in a detectable way. The contribution to the signal from photons that interact with the sample scales as ∝ I p 1 / 2 , where I p is the source intensity, compared with ∝ I p of classical diffraction. This makes imaging with weak fields possible, providing high signal-to-noise ratio, avoiding damage to delicate samples. A Schmidt decomposition of the state of the field can be used for image enhancement by reweighting the Schmidt modes contributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase diagram of the relaxor ferroelectric (1- x )Pb(Mg 1/3 Nb 2/3 )O 3 + x PbTiO 3 revisited: a neutron powder diffraction study of the relaxor skin effect

We revisit the phase diagram of the relaxor ferroelectric PMN- x PT using neutron powder diffraction to test suggestions that residual oxygen vacancies and/or strain affect the ground state crystal structure. Powdered samples of PMN- x PT were prepared with nominal compositions of x = 0:10, 0.20, 0.30, and 0.40 and divided into two identical sets, one of which was annealed in air to relieve grinding-induced strain and to promote an ideal oxygen stoichiometry. For a given composition and temperature the same structural phase is observed for each specimen. However, the distortions in all of the annealed samples are smaller than those in the as-grown samples. Further, the diffraction patterns for x = 0:10, 0.20, and 0.30 are best refined using the monoclinic Cm space group. By comparing our neutron diffraction results to those obtained on single crystals having similar compositions, we conclude that the relaxor skin effect in PMN- x PT vanishes on the Ti-rich side of the morphotropic phase boundary.

morphotropic phase boundary↗

OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. III. MEASURES BELOW THE DIFFRACTION LIMIT OF THE WIYN TELESCOPE

In this paper, we study the ability of CCD- and electron-multiplying-CCD-based speckle imaging to obtain reliable astrometry and photometry of binary stars below the diffraction limit of the WIYN 3.5 m Telescope. We present a total of 120 measures of binary stars, 75 of which are below the diffraction limit. The measures are divided into two groups that have different measurement accuracy and precision. The first group is composed of standard speckle observations, that is, a sequence of speckle images taken in a single filter, while the second group consists of paired observations where the two observations are taken on the same observing run and in different filters. The more recent paired observations were taken simultaneously with the Differential Speckle Survey Instrument, which is a two-channel speckle imaging system. In comparing our results to the ephemeris positions of binaries with known orbits, we find that paired observations provide the opportunity to identify cases of systematic error in separation below the diffraction limit and after removing these from consideration, we obtain a linear measurement uncertainty of 3-4 mas. However, if observations are unpaired or if two observations taken in the same filter are paired, it becomes harder to identify cases of systematic error, presumably because the largest source of this error is residual atmospheric dispersion, which is color dependent. When observations are unpaired, we find that it is unwise to report separations below approximately 20 mas, as these are most susceptible to this effect. Using the final results obtained, we are able to update two older orbits in the literature and present preliminary orbits for three systems that were discovered by Hipparcos.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging nanoscale lattice variations by machine learning of x-ray diffraction microscopy data

In this paper, we present a novel methodology based on machine learning to extract lattice variations in crystalline materials, at the nanoscale, from an x-ray Bragg diffraction-based imaging technique. By employing a full-field microscopy setup, we capture real space images of materials, with imaging contrast determined solely by the x-ray diffracted signal. The data sets that emanate from this imaging technique are a hybrid of real space information (image spatial support) and reciprocal lattice space information (image contrast), and are intrinsically multidimensional (5D). By a judicious application of established unsupervised machine learning techniques and multivariate analysis to this multidimensional data cube, we show how to extract features that can be ascribed physical interpretations in terms of common structural distortions, such as lattice tilts and dislocation arrays. Finally, we demonstrate this 'big data' approach to x-ray diffraction microscopy by identifying structural defects present in an epitaxial ferroelectric thin-film of lead zirconate titanate.

36 MATERIALS SCIENCE↗

Bragg coherent diffraction imaging of iron diffusion into gold nanocrystals

Understanding how diffusion takes place within nanocrystals is of great importance for their stability and for controlling their synthesis. In this study, we used the strain sensitivity of Bragg coherent diffraction imaging (BCDI) to study the diffusion of iron into individual gold nanocrystals in situ at elevated temperatures. The BCDI experiments were performed at the I-07 beamline at Diamond Light Source, UK. The diffraction pattern of individual gold nanocrystals was measured around the (11-1) Bragg peak of gold before and after iron deposition as a function of temperature and time. Phase retrieval algorithms were used to obtain real space reconstructions of the nanocrystals from their measured diffraction patterns. Alloying of iron with gold at sample temperatures of 300 °C–500 °C and dealloying of iron from gold at 600 °C were observed. The volume of the alloyed region in the nanocrystals was found to increase with the dose of iron. However, no significant time dependence was observed for the structure following each iron deposition, suggesting that the samples reached equilibrium relatively quickly. The resulting phase distribution within the gold nanocrystals after the iron depositions suggests a contraction due to diffusion of iron. Furthermore, our results show that BCDI is a useful technique for studying diffusion in three dimensions and alloying behaviour in individual crystalline grains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A large interlaboratory electron diffraction study of monolayer graphene

Standardisation of data collection and analysis is essential to enable commercialisation of 2D materials in a wide range of technologies. Selected area electron diffraction (SAED) in the transmission electron microscope (TEM) is one of the key methods for distinguishing monolayer from bilayer and few-layer graphene by comparing the 1st and 2nd order diffraction spot intensities. Yet there are many factors that can affect the reliability of data collection and interpretation, causing the measurement of monolayer samples to deviate from the literature boundary condition of $I_{\{\bar{2}110\}}$$/$$I_{\{1\bar{1}00\}}$ < 1 for monolayer graphene (1LG). Here we present the results of a large interlaboratory SAED comparison study, where 15 international laboratories measured and analysed nominally identical samples of chemical vapour deposited graphene. Large variations were observed in the measured ratios of diffraction spot intensities, with the largest variance associated with poor quality SAED data resulting from inadequate specimen handling and storage. To inform the reliable determination of monolayer thickness from SAED patterns we provide a description of best practice for specimen handling, TEM operation, data collection and analysis. This work was undertaken within VAMAS Technical Working Area 41: Graphene and related 2D materials—Project 9, the results of which have been directly incorporated into ISO/TS 21356–2 for the characterisation of graphene sheets. We find that when this methodology is followed, 1LG can be distinguished from bilayer or thicker material with high confidence where analysis of a single SAED pattern gives $I_{\{\bar{2}110\}}$$/$$I_{\{1\bar{1}00\}}$ < 1.2, even in the absence of precise specimen tilting.

2D materials↗

Adaptive sampling for accelerating neutron diffraction-based strain mapping *

Abstract Neutron diffraction is a useful technique for mapping residual strains in dense metal objects. The technique works by placing an object in the path of a neutron beam, measuring the diffracted signals and inferring the local lattice strain values from the measurement. In order to map the strains across the entire object, the object is stepped one position at a time in the path of the neutron beam, typically in raster order, and at each position a strain value is estimated. Typical dwell times at neutron diffraction instruments result in an overall measurement that can take several hours to map an object that is several tens of centimeters in each dimension at a resolution of a few millimeters, during which the end users do not have an estimate of the global strain features and are at risk of incomplete information in case of instruments outages. In this paper, we propose an object adaptive sampling strategy to measure the significant points first. We start with a small initial uniform set of measurement points across the object to be mapped, compute the strain in those positions and use a machine learning technique to predict the next position to measure in the object. Specifically, we use a Bayesian optimization based on a Gaussian process regression method to infer the underlying strain field from a sparse set of measurements and predict the next most informative positions to measure based on estimates of the mean and variance in the strain fields estimated from the previously measured points. We demonstrate our real-time measure-infer-predict workflow on additively manufactured steel parts—demonstrating that we can get an accurate strain estimate even with 30%–40% of the typical number of measurements—leading the path to faster strain mapping with useful real-time feedback. We emphasize that the proposed method is general and can be used for fast mapping of other material properties such as phase fractions from time-consuming point-wise neutron measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-angle Precession Electron Diffraction (MAPED): A Versatile Approach to 4D-STEM Precession

Precession of a converged beam during acquisition of a 4D-STEM dataset improves strain, orientation, and phase mapping accuracy by averaging over continuous angles of illumination. Precession experiments usually rely on integrated systems, where automatic alignments lead to fast, high-quality results. The dependence of these experiments on specific hardware and software is evident even when switching to nonintegrated detectors on a precession tool, as experimental set-up becomes challenging and time-consuming. Here, we introduce multi-angle precession electron diffraction (MAPED): a method to perform electron diffraction by collecting sequential 4D-STEM scans at different incident beam tilts. The multiple diffraction datasets are averaged together postacquisition, resulting in a single dataset that minimizes the impact of the curvature and orientation of the Ewald sphere relative to the crystal under study. Our results demonstrate that even four additional tilts improved measurement of material properties, namely strain and orientation, as compared to single-tilt 4D-STEM experiments. We show the versatility and flexibility of our MAPED approach with data collected on a number of microscopes with different hardware configurations and a variety of detectors.

4D-STEM↗

Diffraction-induced laser pulse splitting in a linear photonic crystal

We demonstrate analytically a linear optical property of photonic crystals--diffraction-induced incident optical pulse splitting in two pulses propagating with different group velocities in a linear photonic crystal. The reason of this phenomenon is in spatially inhomogeneous field localization within the photonic crystal in case of the Bragg diffraction at the Laue scheme. The field of the fast first pulse is mainly localized within low refractive index layers, whereas the slow second pulse field is mostly in high refractive index layers. Changing optical properties of either high-index or low-index layers of periodical multilayer structure, it is possible to control parameters of each propagating pulse separately. The distance between two transmitted and two diffractively reflected output pulses can be controlled by varying the crystal thickness and modulation depth of the refractive index.

36 MATERIALS SCIENCE↗