Search NASA⌕ Search

SEARCH · Search NASA

Results for “Discriminant Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Evaluation of the Lactate-to-N-Acetyl-aspartate Ratio Defined With Magnetic Resonance Spectroscopic Imaging Before Radiation Therapy as a New Predictive Marker of the Site of Relapse in Patients With Glioblastoma Multiforme

Purpose: Because lactate accumulation is considered a surrogate for hypoxia and tumor radiation resistance, we studied the spatial distribution of the lactate-to-N-acetyl-aspartate ratio (LNR) before radiation therapy (RT) with 3D proton magnetic resonance spectroscopic imaging (3D-{sup 1}H-MRSI) and assessed its impact on local tumor control in glioblastoma (GBM). Methods and Materials: Fourteen patients with newly diagnosed GBM included in a phase 2 chemoradiation therapy trial constituted our database. Magnetic resonance imaging (MRI) and MRSI data before RT were evaluated and correlated to MRI data at relapse. The optimal threshold for tumor-associated LNR was determined with receiver-operating-characteristic (ROC) curve analysis of the pre-RT LNR values and MRI characteristics of the tumor. This threshold was used to segment pre-RT normalized LNR maps. Two spatial analyses were performed: (1) a pre-RT volumetric comparison of abnormal LNR areas with regions of MRI-defined lesions and a choline (Cho)-to- N-acetyl-aspartate (NAA) ratio ≥2 (CNR2); and (2) a voxel-by-voxel spatial analysis of 4,186,185 voxels with the intention of evaluating whether pre-RT abnormal LNR areas were predictive of the site of local recurrence. Results: A LNR of ≥0.4 (LNR-0.4) discriminated between tumor-associated and normal LNR values with 88.8% sensitivity and 97.6% specificity. LNR-0.4 voxels were spatially different from those of MRI-defined lesions, representing 44% of contrast enhancement, 64% of central necrosis, and 26% of fluid-attenuated inversion recovery (FLAIR) abnormality volumes before RT. They extended beyond the overlap with CNR2 for most patients (median: 20 cm{sup 3}; range: 6-49 cm{sup 3}). LNR-0.4 voxels were significantly predictive of local recurrence, regarded as contrast enhancement at relapse: 71% of voxels with a LNR-0.4 before RT were contrast enhanced at relapse versus 10% of voxels with a normal LNR (P<.01). Conclusions: Pre-RT LNR-0.4 in GBM indicates tumor areas that are likely to relapse. Further investigations are needed to confirm lactate imaging as a tool to define additional biological target volumes for dose painting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping coastal vegetation, land use and environmental impact from ERTS-1

The author has identified the following significant results. Vegetation map overlays at a scale of 1:24,000 compiled by multispectral analysis from NASA aircraft imagery for all of Delaware's wetlands are being used as ground truth for ERTS-1 mapping and by state agencies for wetlands management. Six major vegetation species were discriminated and mapped, including percentages of minor species. Analogue enhancements of wetlands vegetation and dredge-fill operations have been produced using General Electric's GEMS data processing and ERTS-1 false color composites. Digital, thematic land use, and vegetation mapping of entire Delaware Bay area is in progress using Bendix Corporation's Earth Resources Data System and ERTS-1 digital tapes. Statistical evaluation of target-group selection reliability has been completed. Three papers have been published on ERTS-1 coastal vegetation and land use. Local and state officials are participating in the ERTS-1 program as co-investigators.

Klemas, V.↗

Frequency noise measurement of diode-pumped Nd:YAG ring lasers

The combined frequency noise spectrum of two model 120-01A nonplanar ring oscillator lasers was measured by first heterodyne detecting the IF signal and then measuring the IF frequency noise using an RF frequency discriminator. The results indicated the presence of a 1/f-squared noise component in the power-spectral density of the frequency fluctuations between 1 Hz and 1 kHz. After incorporating this 1/f-squared into the analysis of the optical phase tracking loop, the measured phase error variance closely matches the theoretical predictions.

Chen, Chien-Chung↗

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani↗

In-Situ XRD/XRF to Support Life Detection on Mars

X-ray diffraction / X-ray fluorescence (XRD/XRF) analysis provides the most comprehensive mineralogical / compositional characterization of rocks and soils of any flight-capable technique. XRD data provide quantitative mineralogy (including abundance of X-ray amorphous materials) and crystal chemistry (structure, elemental composition and valence state), and XRF data provide complimentary major, minor, and some trace element abundances. Both types of data are important in evaluating habitability (environment of formation) and biosignature preservation/degradation (post-depositional diagenetic change). Whether or not a relict biosignature is detected, the mineral assemblage and its geochemistry can be used to determine the habitability of an ancient environment (e.g., salinity, pH, temperature), and to identify potential sources of energy for life (e.g., elements in different redox states). In this respect, a null result (a habitable environment lacking evidence of life) can play an important role in constraining the parameters of the search. Conversely, diagenetic alteration (taphonomic change) resulting from post-depositional variations in temperature, pressure or fluid chemistry can preserve evidence of biogenicity, erase such evidence completely or indeed can provide for post-depositional habitable conditions in the subsurface. XRD / XRF data are critical to these determinations. The CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover is the first XRD instrument flown in space. CheMin operates in transmission geometry with a Co X-ray source to minimize fluorescence from iron. Diffracted photons are collected with an energy-sensitive charge-coupled device (CCD). The position of the diffracted photons provides structural information for minerals, whereas the energy of sample-generated X-ray fluorescence photons provides elemental information, though these XRF data are qualitative. Mineralogical data from the CheMin XRD identified the three circumstances above: habitable depositional environments (e.g., Yellowknife Bay), habitable subsurface/diagenetic environments (e.g., throughout the Murray formation), and diagenetic conditions that may destroy evidence of habitability (e.g., oxidative and acidic environments at Vera Rubin ridge). Technological advances in X-ray technology and lessons learned from the operation of CheMin on Mars have resulted in a next-generation XRD/XRF, called CheMinX. Replacement of CheMin’s CCD with an array of hybrid pixel detectors and improvements in focusing optics dramatically decrease analysis time (15 minutes vs. 22 hours for MSL-CheMin) and result in a better angular resolution (0.18 vs. 0.30 °2θ for MSL-CheMin). This increased resolution improves mineral detection, including discrimination between types of pyroxenes, which is not possible with MSL-CheMin data. The hybrid pixel detectors do not require cooling like the MSL-CheMin CCD, therefore reducing the power needed to operate CheMinX. CheMinX has a silicon-drift detector (SDD) to measure fluoresced photons, enabling the quantification of major, minor, and some trace elements via XRF. XRD/XRF data are collected simultaneously in CheMinX, obviating the need for multiple compositional instruments. The CheMinX design also improves upon MSL-CheMin’s sample handling. Instead of sample cells on wheel, which are often not reusable and add complexity in commanding the instrument, CheMinX has single-use cells in a cartridge/dispenser configuration. Because of these improvements, CheMinX is an ideal instrument for Discovery-class life-detection missions, including Mars Life Explorer that was recommended for development in the Planetary Science and Astrobiology Decadal Survey 2023-2032.

E B Rampe↗

A Deep Generative Deconvolutional Image Model

A deep generative model is developed for representation and analysis of images, based on a hierarchical convolutional dictionary-learning framework. Stochastic unpooling is employed to link consecutive layers in the model, yielding top-down image generation. A Bayesian support vector machine is linked to the top-layer features, yielding max-margin discrimination. Deep deconvolutional inference is employed when testing, to infer the latent features, and the top-layer features are connected with the max-margin classifier for discrimination tasks. The model is efficiently trained using a Monte Carlo expectation-maximization (MCEM) algorithm; the algorithm is implemented on graphical processor units (GPU) to enable large-scale learning, and fast testing. Excellent results are obtained on several benchmark datasets, including ImageNet, demonstrating that the proposed model achieves results that are highly competitive with similarly sized convolutional neural networks.

convolutional neural network↗

Hyperspectral imaging of minerals in the longwave infrared: the use of laboratory directional-hemispherical reference measurements for field exploration data

Hyperspectral Imaging (HSI) continues to grow as a method for remote detection of vegetation, materials, minerals, and pure chemicals. We have used a longwave infrared (7.7 - 11.8 µm) imaging spectrometer in a static outdoor experiment to collect HSI data from 24 minerals and background materials to determine the efficacy with which HSI can remotely detect and distinguish both pure minerals and mineral mixtures at three solar angles (25°, 35°, and 45° relative to ground) as well as varying backgrounds and other sample effects. Measurements were obtained separately for the minerals and materials mounted directly both on a bare plywood board and a plywood board coated with aluminum foil: 19 powders (3 mixtures and 16 pure mineral powders) held in polyethylene bottle lids as well as 5 samples in rock form were taped directly to the boards. The primary goal of the experiment was to demonstrate that a longwave infrared (LWIR) library of solids and minerals collected as directional-hemispherical reflectance spectra in the laboratory can be used directly for HSI field identification. Prior to the experiment, all 24 mineral/inorganic samples were measured in the laboratory using a Fourier transform infrared spectrometer (FTIR) equipped with a gold-coated IR integrating sphere; the spectra were assimilated as part of a larger reference library of 21 pure minerals, 3 mixtures, and the polyethylene lid. Principal components analysis (PCA) with mean-centering was used in an exploratory analysis of the HSI images and showed that for the aluminum coated board, the first principal component captured the difference between signal that resembled a blackbody and the highly reflective aluminum background. In contrast, principal components PC 2, 3, and 4 were able to discriminate the materials including phosphates, sulfates, silicates, carbonates, and the mixtures. Results from generalized least squares target detection clearly showed that laboratory reference spectra of minerals could be utilized as targets with high fidelity for field detection, both for pure and mixed samples.

47 OTHER INSTRUMENTATION↗

Machine Learning Correlation of Electron Micrographs and ToF-SIMS for the Analysis of Organic Biomarkers in Mudstone

The spatial distribution of organics in geological samples can be used to determine when and how these organics were incorporated into the host rock. Mass spectrometry (MS) imaging can rapidly collect a large amount of data, but ions produced are mixed without discrimination, resulting in complex mass spectra that can be difficult to interpret. Here, we apply unsupervised and supervised machine learning (ML) to help interpret spectra from time-of-flight-secondary ion mass spectrometry (ToF-SIMS) of an organic-carbon-rich mudstone of the Middle Jurassic of England (UK). It was previously shown that the presence of sterane molecular biomarkers in this sample can be detected via ToF-SIMS (Pasterski, M. J. et al., Astrobiology 2023, 23, 936). We use unsupervised ML on scanning electron microscopy–electron dispersive spectroscopy (SEM-EDS) measurements to define compositional categories based on differences in elemental abundances. We then test the ability of four ML algorithms─k-nearest neighbors (KNN), recursive partitioning and regressive trees (RPART), eXtreme gradient boost (XGBoost), and random forest (RF)─to classify the ToF-SIM spectra using (1) the categories assigned via SEM-EDS, (2) organic and inorganic labels assigned via SEM-EDS, and (3) the presence or absence of detectable steranes in ToF-SIMS spectra. In terms of predictive accuracy and balanced accuracy, KNN was the best performing model and RPART the worst. The feature importance, or the specific features of the ToF-SIM spectra used by the models to make classifications, cannot be determined for KNN, preventing posthoc model interpretation. Nevertheless, the feature importance extracted from the other models was useful for interpreting spectra. In conclusion, we determined that some of the organic ions used to classify biomarker containing spectra may be fragment ions derived from kerogen which is abundant in this mudstone sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the estimation of the correlation dimension and its application to radar reflector discrimination

Recently, system theorists have recognized that low order systems of nonlinear differential equations can give rise to solutions which are neither periodic, constant, nor predictable in steady state, but which are nonetheless bounded and deterministic. This behavior, which was first described in the study of weather systems, has been termed 'chaotic.' Much study of chaotic systems has concentrated on analysis of the systems' phase space attractors. It has been recognized that invariant measures of the attractor possess inherent information about the system. One such measure is the dimension of the attractors. The dimension of a chaotic attractor has been shown to be noninteger, leading to the term 'strange attractor;' the attractor is said to have a fractal structure. The correlation dimension has become one of the most popular measures of dimension. However, many problems have been identified in correlation dimension estimation from time sequences. The most common methods for obtaining the correlation dimension have been least squares curves fitting to find the slope of the correlation integral and the Takens Estimator. However, these estimates show unacceptable sensitivity to the upper limit on the distance chosen. Here, a new method is proposed which is shown to be rather insensitive to the upper limit and to perform in a very stable manner, at least in the absence of noise. The correlation dimension is also shown to be an effective discriminant in distinguishing between radar returns resulting from weather and those from the ground. The weather returns are shown to have a correlation dimension generally between 2.0 and 3.0, while ground returns have a correlation dimension exceeding 3.0.

Barnett, Kevin D.↗

Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security

Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and {gamma} rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/{gamma}-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flash point and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/{gamma} separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3 x 10{sup 6} events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting Olivine (Fo-Fa) Compositions from Raman Spectral Peak Positions

Olivine and pyroxene are two major basaltic minerals that have been identified at Gusev Crater and Meridiani Planum by the Mars Exploration Rovers. Full petrologic characterization of a sample (rock or soil), however, requires determining the range of mineral compositions, extent of zoning, range of grain sizes, mineral associations, presence of xenocrysts, etc. Information of this sort will aid the interpretation of sample crystallization and differentiation histories and help discriminate between lithologies. In Raman spectroscopic experiments, minerals are identified by their spectral patterns and mineral compositions can be inferred from the peak positions. Instruments currently in use or slated for impending surface exploration missions provide only average elemental compositions for relatively large rock or soil targets or bulk mineral analysis. No techniques currently in use or scheduled for flight can characterize both structure and composition of individual mineral grains, in-situ, like the Mars Microbeam Raman Spectrometer (MMRS). The MMRS is designed to take 100 spectra along a 1 cm linear traverse on the surface of a sample, with contributions from one or a few mineral phases per spectrum. We presented a method to extract structural and compositional information from the Raman spectra of quadrilateral pyroxenes. The pyroxene calibration was applied to a Raman spectroscopic study of Martian meteorite EETA79001 along with a preliminary olivine calibration, where we demonstrated the capability to discriminate related lithologies using Raman point counts. This paper presents an improved olivine calibration that will further aid sample characterization and the study of alteration processes.

Kuebler, K.↗

Liquid Scintillation Counting of Environmental Radioisotopes: A Review of the Impact of Background Reduction

Liquid scintillation counting (LSC) is a versatile and commonplace method for radiometric measurement of charged particle emitting radionuclides. The LSC method provides utility in a range of environmental science applications including hydrological studies of water transport, anthropogenic releases of radionuclides into the environment, and vertical mixing rates within oceans. Instrumental measurement background is one limiting factor of radiometric measurement sensitivity. As part of the development of a custom low background LSC system located in a shallow underground laboratory at Pacific Northwest National Laboratory, a number of measurement applications of LSC have been considered and are summarized here. The focus is on determining which aspects of such measurements would gain the greatest benefit from the reduction of LSC backgrounds by a factor of 10-100 relative to values reported in the literature. Examples of benefits include lowering the minimum detectable activity, reducing the sample size required, and shortening the elapsed timeline of the processing and analysis sequence. In particular tritium, strontium, and actinium isotopes are examined as these isotopes cover a range of requirements related to the LSC measurement method (e.g., 3H: low energy; Sr: spectral deconvolution; Ac: alpha/beta discrimination).

actinium↗

Effect of Radiotherapy and Chemotherapy on the Risk of Mucositis During Intensity-Modulated Radiation Therapy for Oropharyngeal Cancer

Purpose: To define the roles of radiotherapy and chemotherapy on the risk of Grade 3+ mucositis during intensity-modulated radiation therapy (IMRT) for oropharyngeal cancer. Methods and Materials: 164 consecutive patients treated with IMRT at two institutions in nonoverlapping treatment eras were selected. All patients were treated with a dose painting approach, three dose levels, and comprehensive bilateral neck treatment under the supervision of the same radiation oncologist. Ninety-three patients received concomitant chemotherapy (cCHT) and 14 received induction chemotherapy (iCHT). Individual information of the dose received by the oral mucosa (OM) was extracted as absolute cumulative dose-volume histogram (DVH), corrected for the elapsed treatment days and reported as weekly (w) DVH. Patients were seen weekly during treatment, and peak acute toxicity equal to or greater than confluent mucositis at any point during the course of IMRT was considered the endpoint. Results: Overall, 129 patients (78.7%) reached the endpoint. The regions that best discriminated between patients with/without Grade 3+ mucositis were found at 10.1 Gy/w (V10.1) and 21 cc (D21), along the x-axis and y-axis of the OM-wDVH, respectively. On multivariate analysis, D21 (odds ratio [OR] = 1.016, 95% confidence interval [CI], 1.009-1.023, p < 0.001) and cCHT (OR = 4.118, 95% CI, 1.659-10.217, p = 0.002) were the only independent predictors. However, V10.1 and D21 were highly correlated (rho = 0.954, p < 0.001) and mutually interchangeable. cCHT would correspond to 88.4 cGy/w to at least 21 cc of OM. Conclusions: Radiotherapy and chemotherapy act independently in determining acute mucosal toxicity; cCHT increases the risk of mucosal Grade 3 toxicity Almost-Equal-To 4 times over radiation therapy alone, and it is equivalent to an extra Almost-Equal-To 6.2 Gy to 21 cc of OM over a 7-week course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inclusive Search for the SM Higgs Boson in the H{yields}{gamma}{gamma} channel at the LHC

A prospective for the inclusive search of the Standard Model Higgs boson in the decay channel H{yields}{gamma}{gamma} is presented with the CMS experiment at the LHC. The analysis relies on a strategy to determine the background characteristics and systematics from data. The strategy is applied to a Monte Model of the QCD background, with full simulation of the detector response. The discrimination between signal and background exploits information on photon isolation and kinematics. The resolution for the reconstructed Higgs boson mass profits from the excellent energy resolution of the CMS crystal calorimeter. A discovery significance above 5 sigma is expected at integrated LHC luminosities below 30 fb{sup -1} for Higgs boson masses below 140 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of intrinsic and induced lateral conduction in space dielectric materials

Characterization of lateral charge carrier conduction in space dielectrics is of high importance for the prediction of charging behavior and electrostatic discharges on satellites. In the present paper, a new experimental approach for the analysis of surface conduction, which is not well understood and characterized in the literature, is established and discussed. Though this method, based on the use of two Kelvin probes, we have been able to discriminate between lateral and bulk charge transports and to reveal the presence of an intrinsic lateral conductivity on Teflon{sup ®} FEP irradiated with low energy electron beam. We demonstrated that lateral intrinsic conductivity is enhanced when incident current density increases and when approaching the sample surface. The experimental results are analyzed through trapping/detrapping and hopping models. Depending on radiation configuration mode, we have revealed as well the presence of a lateral conductivity that is enhanced by radiation ionization processes, and explained as well with a trapping/recombination model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal neutron imaging in an active interrogation environment

We have developed a thermal-neutron coded-aperture imager that reveals the locations of hydrogenous materials from which thermal neutrons are being emitted. This imaging detector can be combined with an accelerator to form an active interrogation system in which fast neutrons are produced in a heavy metal target by means of xcitation by high energy photons. The photo-induced neutrons can be either prompt or delayed, depending on whether neutronemitting fission products are generated. Provided that there are hydrogenous materials close to the target, some of the photo-induced neutrons slow down and emerge from the surface at thermal energies. These neutrons can be used to create images that show the location and shape of the thermalizing materials. Analysis of the temporal response of the neutron flux provides information about delayed neutrons from induced fission if there are fissionable materials in the target. The combination of imaging and time-of-flight discrimination helps to improve the signal-to-background ratio. It is also possible to interrogate the target with neutrons, for example using a D-T generator. In this case, an image can be obtained from hydrogenous material in a target without the presence of heavy metal. In addition, if fissionable material is present in the target, probing with fast neutrons can stimulate delayed neutrons from fission, and the imager can detect and locate the object of interest, using appropriate time gating. Operation of this sensitive detection equipment in the vicinity of an accelerator presents a number of challenges, because the accelerator emits electromagnetic interference as well as stray ionizing radiation, which can mask the signals of interest.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Discriminating semiarid vegetation using airborne imaging spectrometer data - A preliminary assessment

A preliminary assessment was made of Airborne Imaging Spectrometer (AIS) data for discriminating and characterizing vegetation in a semiarid environment. May and October AIS data sets were acquired over a large alluvial fan in eastern California, on which were found Great Basin desert shrub communities. Maximum likelihood classification of a principal components representation of the May AIS data enabled discrimination of subtle spatial detail in images relating to vegetation and soil characteristics. The spatial patterns in the May AIS classification were, however, too detailed for complete interpretation with existing ground data. A similar analysis of the October AIS data yielded poor results. Comparison of AIS results with a similar analysis of May Landsat Thematic Mapper data showed that the May AIS data contained approximately three to four times as much spectrally coherent information. When only two shortwave infrared TM bands were used, results were similar to those from AIS data acquired in October.

Thomas, Randall W.↗