Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗

Third-order correlator for measuring the time profile of petawatt laser pulses

A third-order correlator with a single-shot time window and a full dynamic range of 10{sup 8} is developed. The time contrast of radiation from the front-end system of a petawatt femtosecond laser complex measured with the correlator within time windows {+-}1 ps and {+-}100 ps was 10{sup 4} and more than 10{sup 8}, respectively. Based on the theoretical analysis of the cross-correlator operation, a number of requirements providing the optimal functioning of the cross-correlator are found. The reasons restricting the technical parameters of the correlator are discussed. (measurement of parameters of laser radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative analysis of 2D spatio-temporal visualisation techniques for the pulsed THz-radiation field using an electro-optic crystal

Two 2D techniques for visualising the field of pulsed THz radiation (‘shadow’ and ‘interferometric’), which are based on the linear electro-optical effect with application of a ZnTe detector crystal 1 × 1 cm in size, are compared. The noise level and dynamic range for the aforementioned techniques are analysed and their applicability limits are discussed. (thz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technique for measuring basic characteristics of electron-optical cameras

A procedure is described for determining the basic parameters of linear-sweep electron-optical cameras. The techniques are considered for measuring the limiting temporal resolution and dynamic range of the PS-1/S1 camera using a femtosecond laser and sinusoidal-modulated laser radiation. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive nonequilibrium design of actin-based metamaterials: Fundamental and practical limits of control

The adaptive and surprising emergent properties of biological materials self-assembled in far-from-equilibrium environments serve as an inspiration for efforts to design nanomaterials. In particular, controlling the conditions of self-assembly can modulate material properties, but there is no systematic understanding of either how to parameterize external control or how controllable a given material can be. Here, we demonstrate that branched actin networks can be encoded with metamaterial properties by dynamically controlling the applied force under which they grow and that the protocols can be selected using multi-task reinforcement learning. These actin networks have tunable responses over a large dynamic range depending on the chosen external protocol, providing a pathway to encoding “memory” within these structures. Interestingly, we obtain a bound that relates the dissipation rate and the rate of “encoding” that gives insight into the constraints on control—both physical and information theoretical. Taken together, these results emphasize the utility and necessity of nonequilibrium control for designing self-assembled nanostructures.

59 BASIC BIOLOGICAL SCIENCES↗

Dissecting neurofilament tail sequence-phosphorylation-structure relationships with multicomponent reconstituted protein brushes

Neurofilaments (NFs) are multisubunit, bottlebrush-shaped intermediate filaments abundant in the axonal cytoskeleton. Each NF subunit contains a long intrinsically disordered tail domain, which protrudes from the NF core to form a “brush” surrounding each NF. Precisely how the tails’ variable charge patterns and repetitive phosphorylation sites mediate their conformation within the brush remains an open question in axonal biology. We address this problem by grafting recombinant NF tail protein constructs NF-Light, -Medium, and -Heavy (NFL, NFM, and NFH) to surfaces, yielding protein brushes of defined stoichiometry that can be phosphorylated in vitro. Atomic force microscopy measurements reveal that brush height depends on composition monotonically but not always linearly for binary NFL:NFM or NFL:NFH systems, and that NFM-based brushes are highly extended, while brushes incorporating the much larger NFH are surprisingly compact even after multisite phosphorylation. Complementary self-consistent field theory (SCFT) predicts multilayer brush morphologies for NFM and phosphorylated NFH brushes. Further experiments and SCFT analysis with designed mutants reveal that N-terminal negative charges in the NFH tail repel phosphorylated residues to generate the multilayer morphology, while the C-terminal charge-neutral region contributes to multilayer brush morphology but not total brush height. Charge-shuffled NFM variants show that charge segregation promotes brush collapse near physiological ionic strengths. Collectively, this study supports a role for NFM in establishing a dynamic range for NF brush conformation, lending insight into previous in vitro and in vivo findings. More broadly, this work establishes a platform for dissecting contributions of disordered protein sequence to conformation at interfaces.

Science & Technology - Other Topics↗

Bistable random momentum transfer in a linear on-chip resonator

Optical switches and bifurcation rely on the nonlinear response of materials. Here, we demonstrate linear temporal bifurcation responses in a passive multimode microresonator, with strongly coupled chaotic and whispering gallery modes (WGMs). In microdisks, the chaotic modes exhibit broadband transfer within the deformed cavities, but their transient response is less explored and yields a random output of the analog signal distributed uniformly from “0” to “1.” Here, we build chaotic states by perturbing the multimode microring resonators with densely packed silicon nanocrystals on the waveguide surface. In vivo measurements reveal random and “digitized” output that ONLY populates around 0 and 1 intensity levels. The bus waveguide mode couples first to chaotic modes, then either dissipates or tunnels into stable WGMs. This binary pathway generates high-contrast, digitized outputs. In conclusion, the fully passive device enables real-time conversion of periodic clock signals into binary outputs with contrasts exceeding 12.3 dB, data rates of up to 10 7 · bits per second, and 20 dB dynamic range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advancing the High Throughput Identification of Liver Fibrosis Protein Signatures Using Multiplexed Ion Mobility Spectrometry

Rapid diagnosis of disease states using less invasive, safer, and more clinically acceptable approaches than presently employed is an imperative goal for the field of medicine. While mass spectrometry (MS)-based proteomics approaches have attempted to meet these objectives, challenges such as the enormous dynamic range of protein concentrations in clinically relevant biofluid samples coupled with the need to address human biodiversity have slowed their employment. Herein, we report on the use of a new platform that addresses these challenges by coupling technical advances in rapid gas phase multiplexed ion mobility spectrometry (IMS) separations [1, 2] with liquid chromatography (LC) and MS to dramatically increase measurement sensitivity and throughput, further enabling future MS-based clinical applications. An initial application of the LC-IMS-MS platform for the analysis of blood serum samples from stratified post-liver transplant patients with recurrent fibrosis progression illustrates its potential utility for disease characterization and use in personalized medicine [3, 4].

Environmental Molecular Sciences Laboratory↗

Enhancements to the New TREAT Automatic Reactor Control System (ARCS)

The Transient Reactor Test (TREAT) facility recently replaced the automatic reactor control system (ARCS). Here, this paper discusses some of the enhancements that were made during the ARCS replacement such as calculations to take into account the nonadiabatic effects and increasing the dynamic range for power and period indication. This paper also discusses upgrades that had been planned but were unable to implemented and potential upgrades for the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

Emerging protein sequencing technologies: proteomics without mass spectrometry?

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been a leading method for proteomics for 30 years. Advantages provided by LC-MS/MS are offset by significant disadvantages, including cost. Recently, several non-mass spectrometric methods have emerged, but little information is available about their capacity to analyze the complex mixtures routine for mass spectrometry. Areas Covered: We review recent non-mass-spectrometric methods for sequencing proteins and peptides, including those using nanopores, sequencing by degradation, reverse translation, and short-epitope mapping, with comments on bioinformatics challenges, fundamental limitations, and areas where new technologies will be more or less competitive with LC-MS/MS. In addition to conventional literature searches, instrument vendor websites, patents, webinars, and preprints were also consulted to give a more up-to-date picture. Expert Opinion: Many new technologies are promising. However, demonstrations that they outperform mass spectrometry in terms of peptides and proteins identified have not yet been published, and astute observers note important disadvantages, especially relating to the dynamic range of single-molecule measurements of complex mixtures. Still, even if the performance of emerging methods proves inferior to LC-MS/MS, their low cost could create a different kind of revolution: a dramatic increase in the number of biology laboratories engaging in new forms of proteomics research.

59 BASIC BIOLOGICAL SCIENCES↗

THE UNAM-KIAS CATALOG OF ISOLATED GALAXIES

A new catalog of isolated galaxies from the Sloan Digital Sky Survey Data Release 5 (SDSS DR5) is presented. A total of 1520 isolated galaxies were found in 1.4 sr of sky. The selection criteria in this UNAM-KIAS catalog are a variation on the criteria developed by Karachentseva, including full redshift information. Through an image processing pipeline that takes advantage of the high-resolution ({approx}0.''4 pixel{sup -1}) and high dynamic range of the SDSS images, a uniform g-band morphological classification for all these galaxies is presented. We identify 80% (Sa-Sm) spirals (50% later than Sbc types) on one hand, and a scarce population of early-type E (6.5%) and S0 (8%) galaxies amounting to 14.5% on the other hand. This magnitude-limited catalog is {approx}80% complete at 16.5, 15.6, 15.2, 14.6, and 14.4 mag in the ugriz bands, respectively. Some representative physical properties including SDSS magnitudes and color distributions, color-color diagrams, absolute magnitude-color, and concentration-color diagrams as a function of morphological type are presented. The UNAM-KIAS Morphological Atlas is also released along with this paper. For each galaxy of a type later than Sa, a mosaic is presented that includes (1) a g-band logarithmic image, (2) a g-band filtered-enhanced image where a Gaussian kernel of various sizes was applied, and (3) a red giant branch color image from the SDSS database. For E/S0/Sa galaxies, in addition to the images in (1), (2), and (3), plots of r-band surface brightness and geometric profiles (ellipticity {epsilon}, position angle PA, and A{sub 4}/B{sub 4} coefficients of the Fourier series expansions of deviations of a pure ellipse) are provided. The size of the sample, the redshift completeness, the availability of high-quality multicolor photometric data and detailed morphological and spectroscopic information make the UNAM-KIAS catalog of isolated galaxies a suitable sample to address important issues such as (1) comparative studies of environmental effects, (2) constraining the currently competing scenarios of galaxy formation and evolution, (3) the nature and evolution of elliptical and spiral galaxies in the field, (4) the spectral properties of a statistically significant number of isolated galaxies and their evolution as a function of redshift, and (5) the fraction of active galactic nuclei in isolated environments, among other important topics. The optimization and estimation of new structural parameters as well as important information to complement existing ones in other wavelengths is being carried out.

79 ASTRONOMY AND ASTROPHYSICS↗

ABSORPTION-LINE PROBES OF THE PREVALENCE AND PROPERTIES OF OUTFLOWS IN PRESENT-DAY STAR-FORMING GALAXIES

We analyze star-forming galaxies drawn from SDSS DR7 to show how the interstellar medium (ISM) Na I {lambda}{lambda}5890, 5896 (Na D) absorption lines depend on galaxy physical properties, and to look for evidence of galactic winds. We combine the spectra of galaxies with similar geometry/physical parameters to create composite spectra with signal-to-noise {approx}300. The stellar continuum is modeled using stellar population synthesis models, and the continuum-normalized spectrum is fit with two Na I absorption components. We find that (1) ISM Na D absorption lines with equivalent widths EW > 0.8 A are only prevalent in disk galaxies with specific properties-large extinction (A{sub V} ), high star formation rates (SFR), high SFR per unit area ({Sigma}{sub SFR}), or high stellar mass (M{sub *}); (2) the ISM Na D absorption lines can be separated into two components: a quiescent disk-like component at the galaxy systemic velocity and an outflow component; (3) the disk-like component is much stronger in the edge-on systems, and the outflow component covers a wide angle but is stronger within 60{sup 0} of the disk rotation axis; (4) the EW and covering factor of the disk component correlate strongly with dust attenuation, highlighting the importance that dust shielding may play in the survival of Na I; (5) the EW of the outflow component depends primarily on {Sigma}{sub SFR} and secondarily on A{sub V} ; and (6) the outflow velocity varies from {approx}120 to 160 km s{sup -1} but shows little hint of a correlation with galaxy physical properties over the modest dynamic range that our sample probes (1.2 dex in log {Sigma}{sub SFR} and 1 dex in log M{sub *}).

79 ASTRONOMY AND ASTROPHYSICS↗

ESTIMATING THE STAR FORMATION RATE AT 1 kpc SCALES IN NEARBY GALAXIES

Using combinations of H{alpha}, ultraviolet (UV), and infrared (IR) emission, we estimate the star formation rate (SFR) surface density, {Sigma}{sub SFR}, at 1 kpc resolution for 30 disk galaxies that are targets of the IRAM HERACLES CO survey. We present a new physically motivated IR spectral-energy-distribution-based approach to account for possible contributions to 24 {mu}m emission not associated with recent star formation. Considering a variety of 'reference' SFRs from the literature, we revisit the calibration of the 24 {mu}m term in hybrid (UV+IR or H{alpha}+IR) tracers. We show that the overall calibration of this term remains uncertain at the factor of two level because of the lack of wide-field, robust reference SFR estimates. Within this uncertainty, published calibrations represent a reasonable starting point for 1 kpc-wide areas of star-forming disk galaxies, but we re-derive and refine the calibration of the IR term in these tracers to match our resolution and approach to 24 {mu}m emission. We compare a large suite of {Sigma}{sub SFR} estimates and find that above {Sigma}{sub SFR} {approx} 10{sup -3} M{sub Sun} yr{sup -1} kpc{sup -2} the systematic differences among tracers are less than a factor of two across two orders of magnitude dynamic range. We caution that methodology and data both become serious issues below this level. We note from simple model considerations that when focusing on a part of a galaxy dominated by a single stellar population, the intrinsic uncertainty in H{alpha}- and FUV-based SFRs is {approx}0.3 and {approx}0.5 dex.

79 ASTRONOMY AND ASTROPHYSICS↗

Galaxy Mergers with Adaptive Mesh Refinement: Star Formation and Hot Gas Outflow

In hierarchical structure formation, merging of galaxies is frequent and known to dramatically affect their properties. To comprehend these interactions high-resolution simulations are indispensable because of the nonlinear coupling between pc and Mpc scales. To this end, we present the first adaptive mesh refinement (AMR) simulation of two merging, low mass, initially gas-rich galaxies (1.8 x 10{sup 10} M{sub {circle_dot}} each), including star formation and feedback. With galaxies resolved by {approx} 2 x 10{sup 7} total computational elements, we achieve unprecedented resolution of the multiphase interstellar medium, finding a widespread starburst in the merging galaxies via shock-induced star formation. The high dynamic range of AMR also allows us to follow the interplay between the galaxies and their embedding medium depicting how galactic outflows and a hot metal-rich halo form. These results demonstrate that AMR provides a powerful tool in understanding interacting galaxies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HARD X-RAY IMAGING OF SOLAR FLARES USING INTERPOLATED VISIBILITIES

RHESSI produces solar flare images with the finest angular and spectral resolutions ever achieved at hard X-ray energies. Because this instrument uses indirect, collimator-based imaging techniques, the 'native' output of which is in the form of 'visibilities' (two-dimensional spatial Fourier components of the image), the development and application of robust, accurate, visibility-based image reconstruction techniques is required. Recognizing that the density of spatial-frequency (u, v) coverage by RHESSI is much sparser than that normally encountered in radio astronomy, we therefore introduce a method for image reconstruction from a relatively sparse distribution of sampled visibilities. The method involves spline interpolation at spatial frequencies less than the largest sampled frequency and the imposition of a positivity constraint on the image to reduce the ringing effects resulting from an unconstrained Fourier transform inversion procedure. Using simulated images consisting both of assumed mathematical forms and of the type of structure typically associated with solar flares, we validate the fidelity, accuracy, and robustness with which the new procedure recovers input images. The method faithfully recovers both single and multiple sources, both compact and extended, over a dynamic range of approx10:1. The performance of the method, which we term as uv{sub s}mooth, is compared with other RHESSI image reconstruction algorithms currently in use and its advantages summarized. We also illustrate the application of the method using RHESSI observations of four solar flares.

79 ASTRONOMY AND ASTROPHYSICS↗