Investigation of primordial black hole bursts using interplanetary network gamma-ray bursts

The detection of a gamma-ray burst (GRB) in the solar neighborhood would have very important implications for GRB phenomenology. The leading theories for cosmological GRBs would not be able to explain such events. The final bursts of evaporating primordial black holes (PBHs), however, would be a natural explanation for local GRBs. We present a novel technique that can constrain the distance to GRBs using detections from widely separated, non-imaging spacecraft. This method can determine the actual distance to the burst if it is local. We applied this method to constrain distances to a sample of 36 short-duration GRBs detected by the Interplanetary Network (IPN) that show observational properties that are expected from PBH evaporations. These bursts have minimum possible distances in the 10 13 –10 18 cm (7–10 5 au) range, which are consistent with the expected PBH energetics and with a possible origin in the solar neighborhood, although none of the bursts can be unambiguously demonstrated to be local. Furthermore, assuming that these bursts are real PBH events, we estimate lower limits on the PBH burst evaporation rate in the solar neighborhood.

79 ASTRONOMY AND ASTROPHYSICS↗

Treatment of radioactive liquid waste by the forced-air exhaust system - 15190

A Natural Evaporation Facility (NEF) was constructed to treat low level (LL) radioactive liquid waste arising from a Radioactive Waste Treatment Facility (RWTF) at the Korea Atomic Energy Research Institute (KAERI). In order to process LL radioactive liquid waste, we investigated the influence of climate condition, mainly atmospheric humidity and temperature, on the amount of evaporation in a forced-air exhaust system in KAERI. Evaporation media were made of cotton and polyester. Air exhaust in the facility was forced by exhaust fans. The evaporation rate and the decontamination factor were calculated and reported as shown in the results section. The evaporation and air supply flow increased at the same rate. In addition, the liquid waste feed rate and temperature of supplied air increased. Regarding the relative humidity of supplied air, the evaporation rate increased as the relative humidity decreased. As the result of this study, the operating conditions for the NEF were optimized in the following areas: The air temperature above 8 deg. C, the air relative humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate 4.6 l/hr.m{sup 2}. The decontamination factor was 1.1x10{sup 3}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Response of a Lithium Vapor Divertor to Cyclical Operation

The lithium vapor divertor concept is being developed as a method to achieve detached divertor conditions in a tokamak while minimizing impurity radiation losses from the core plasma. SOLPS-ITER modeling has previously been used to identify some of the geometric constraints and required lithium evaporation rate of a lithium vapor divertor in a medium-sized tokamak during steady-state operation. Here an updated conceptual design based on these operating requirements is introduced and the thermal response of the system is modeled during cyclical operation, consistent with operation in a short-pulse tokamak. Controllability of the temperature of the lithium capillary porous system (CPS) is achieved by adopting a design where there is no line-of-sight for radiation from the plasma to reach the heated CPS surface. Operational strategies to minimize the amount of lithium evaporated between plasma discharges while achieving steady evaporation rates during plasma discharges are discussed and modeled here. The optimal feedforward control strategy demonstrated in this work is to ramp up the temperature of the evaporator as quickly as possible immediately before a plasma discharge and then reduce the heating to match the desired steady-state net evaporation rate just before the plasma discharge begins, allowing the thermal inertia of the system to stabilize the evaporation rate during the first second of the plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Falling-film thermosyphons: Application to water harvesting from humid gas streams

Water harvesting from humid gas streams is central to fresh-water production, desalination, and particulate removal from combustion gas streams. Two-phase thermosyphons are well suited for these applications due to their very low thermal resistance, but have several operating limits at the high heat flows required for such applications. This work introduces the falling-film thermosyphon for large-scale condensation applications. Working fluid is pumped to the top of the evaporator to provide the evaporating liquid film on the inner tube wall, rather than by vapor condensation. The flooding, dry-out and pool-boiling limits are eliminated, resulting in significantly higher maximum heat fluxes for the same physical evaporator size. Furthermore, the condenser no longer needs to be located vertically above the evaporator, which allows for a standard steam condenser to be used. A model for the condensation process in humid air was developed that estimates the fluid and heat transfer and is confirmed experimentally. Further benefits include the use of a high-thermal-conductivity polymer material for the evaporator section to minimize corrosion, and the ability to impose a temperature boundary condition on the evaporator, which is made possible due to the elimination of a liquid pool.

42 ENGINEERING↗

Drizzle and Turbulence below closed cellular marine stratocumulus clouds

Drizzle is ubiquitous in marine boundary layer stratocumulus clouds with much of it evaporating before reaching the surface. Ten days of observations made at the Atmospheric Radiation Measurement (ARM)’s Eastern North Atlantic (ENA) site during closed cellular stratocumulus cloud conditions are used to characterize drizzle below the cloud base and its impact on the boundary layer turbulence. Cloud and drizzle micro- and macro-physical properties were retrieved by combining the data from vertically pointing Doppler cloud radar, ceilometer, and microwave radiometer. On average the drizzle shafts were 28.14 km wide, with cloud base rain rate and modal diameter of 1.26 mm day-1 and 145.26 µm respectively. The rain rate at the surface was negligible yielding an average diabatic cooling of -30.60 Wm-2 in the sub-cloud layer. The LWP and turbulence within the boundary layer increased with an increase in the cloud top radiative cooling, however none of these variables exhibited any relationship with cloud base rain rate. For a similar amount of radiative cooling at the cloud top, the average variance of vertical velocity in the sub-cloud layer was about 10% lower during strongly precipitating conditions as compared to lightly precipitating conditions. The reduction in the variance of vertical velocity due to drizzle evaporation was primarily confined to the upper half of the sub-cloud layer and was due reduction in the strengths of the downdrafts. Collectively our results show substantial impact of drizzle evaporation on boundary layer turbulence, necessitating its accurate representation in the Earth System Models.

drizzle↗

Integrated cooling (i-Cool) textile of heat conduction and sweat transportation for personal perspiration management

Perspiration evaporation plays an indispensable role in human body heat dissipation. However, conventional textiles tend to focus on sweat removal and pay little attention to the basic thermoregulation function of sweat, showing limited evaporation ability and cooling efficiency in moderate/profuse perspiration scenarios. Here, we propose an integrated cooling (i-Cool) textile with unique functional structure design for personal perspiration management. By integrating heat conductive pathways and water transport channels decently, i-Cool exhibits enhanced evaporation ability and high sweat evaporative cooling efficiency, not merely liquid sweat wicking function. In the steady-state evaporation test, compared to cotton, up to over 100% reduction in water mass gain ratio, and 3 times higher skin power density increment for every unit of sweat evaporation are demonstrated. Besides, i-Cool shows about 3 °C cooling effect with greatly reduced sweat consumption than cotton in the artificial sweating skin test. The practical application feasibility of i-Cool design principles is well validated based on commercial fabrics. Owing to its exceptional personal perspiration management performance, we expect the i-Cool concept can provide promising design guidelines for next-generation perspiration management textiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nonsingular black holes as dark matter

It is commonly assumed that low-mass primordial black holes cannot constitute a significant fraction of the dark matter in our universe due to their predicted short lifetimes from the conventional Hawking radiation and evaporation process. Assuming physical black holes are nonsingular—likely due to quantum gravity or other high-energy physics—we demonstrate that a large class of nonsingular black holes have finite evaporation temperatures. This can lead to slowly evaporating low-mass black holes or to remnant mass states that circumvent traditional evaporation constraints. As a proof of concept, we explore the limiting curvature hypothesis and the evaporation process of a nonsingular black hole solution in two-dimensional dilaton gravity. We identify generic features of the radiation profile and compare them with known regular black holes, such as the Bardeen solution in four dimensions. Remnant masses are proportional to the fundamental length scale, and we argue that slowly evaporating low-mass nonsingular black holes, or remnants, are viable dark matter candidates. Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS↗

Clumped isotope constraints on changes in latest Pleistocene hydroclimate in the northwestern Great Basin: Lake Surprise, California

Abstract During the Last Glacial Maximum (LGM) and subsequent deglaciation, the Great Basin in the southwestern United States was covered by numerous extensive closed-basin lakes, in stark contrast with the predominately arid climate observed today. This transition from lakes in the Late Pleistocene to modern aridity implies large changes in the regional water balance. Whether these changes were driven by increased precipitation rates due to changes in atmospheric dynamics, decreased evaporation rates resulting from temperature depression and summer insolation changes, or some combination of the two remains uncertain. The factors contributing to these large-scale changes in hydroclimate are critical to resolve, given that this region is poised to undergo future anthropogenic-forced climate changes with large uncertainties in model simulations for the 21st century. Furthermore, there are ambiguous constraints on the magnitude and even the sign of changes in key hydroclimate variables between the Last Glacial Maximum and the present day in both proxy reconstructions and climate model analyses of the region. Here we report thermodynamically derived estimates of changes in temperature, precipitation, and evaporation rates, as well as the isotopic composition of lake water, using clumped isotope data from an ancient lake in the northwestern Great Basin, Lake Surprise (California). Compared to modern climate, mean annual air temperature at Lake Surprise was 4.7 °C lower during the Last Glacial Maximum, with decreased evaporation rates and similar precipitation rates to modern. During the mid-deglacial period, the growth of Lake Surprise implied that the lake hydrologic budget briefly departed from steady state. Our reconstructions indicate that this growth took place rapidly, while the subsequent lake regression took place over several thousand years. Using models for precipitation and evaporation constrained from clumped isotope results, we determine that the disappearance of Lake Surprise coincided with a moderate increase in lake temperature, along with increasing evaporation rates outpacing increasing precipitation rates. Concomitant analysis of proxy data and climate model simulations for the Last Glacial Maximum are used to provide a robust means to understand past climate change, and by extension, predict how current hydroclimates may respond to expected future climate forcings. We suggest that an expansion of this analysis to more basins across a larger spatial scale could provide valuable insight into proposed climate forcings, and aid in climate model process depiction. Ultimately, our analysis highlights the importance of temperature-driven evaporation as a mechanism for lake growth and retreat in this region.

Geology↗

Innovative thermal distillation method using solar heat localization

The thermal distillation uses energy to evaporate water and subsequently condense the vapor to liquid form. Waste energy from industrial processes, electricity, or solar energy are the examples of an input energy for thermal distillation systems. In this paper, we have designed, fabricated, and tested an eco-friendly and low- cost distillation system which uses solar heat localization for evaporation of water and later condense the vapor back to liquid as liquid water. The unique feature of this method is the high rate of evaporation when compared to other thermal solar distillation/desalination systems. In this method, the incoming heat is confined to the porous media where bottom layer acts a porous insulator. The capillary force in the porous structure pumps up the liquid water to the hot surface, within the porous medium, where liquid heats up and changes to vapor phase. Since there is no moving part in this method, and due to its independency to electricity, it a great candidate for deployment in remote areas that access to grid power is limited and maintenance is not feasible.

Jaladi, Divya↗

Numerical case study of the aerosol–cloud interactions in warm boundary layer clouds over the eastern North Atlantic with an interactive chemistry module

The presence of warm boundary layer stratiform clouds over the eastern North Atlantic (ENA) region is commonly influenced by the Azores High, especially during the summer season. To investigate comprehensive aerosol–cloud interactions, this study employs the Weather Research and Forecasting model coupled with a chemistry component (WRF-Chem), incorporating aerosol chemical components that are relevant to the formation of cloud condensation nuclei (CCN) and accounting for aerosol spatiotemporal variation. This study focuses on aerosol indirect effects, particularly the long-range transport of aerosols, in the ENA region under three different weather regimes: a ridge with a surface high-pressure system, a post-trough with a surface high-pressure system, and a weak trough. The WRF-Chem simulations conducted at a near-large-eddy scale offer valuable insights into the model's performance, especially in terms of its ability to use high spatial resolution to capture mesoscale cloud features across various weather regimes. Our result shows that introducing 5 times more aerosols to either non-precipitating or precipitating clouds significantly increases ambient CCN numbers, resulting in, to varying degrees, higher liquid water path (LWP) values. The substantial aerosol–cloud interaction especially occurs in the precipitating clouds and demonstrates the susceptibility of the LWP to changes in CCN under different regimes. Conversely, thin, non-rain clouds at the edges of a cloud system are prone to evaporation, exhibiting an aerosol drying effect. The aerosols released during this process transition back to the accumulation mode, facilitating future activation. This dynamic behavior is not adequately represented in prescribed-aerosol simulations.

54 ENVIRONMENTAL SCIENCES↗

Retrofit device to improve vapor compression cooling system performance by dynamic blower speed modulation

A device and method are provided to improve performance of a vapor compression system using a retrofittable control board to start up the vapor compression system with the evaporator blower initially set to a high speed. A baseline evaporator operating temperature with the evaporator blower operating at the high speed is recorded, and then the device detects if a predetermined acceptable change in evaporator temperature has occurred. The evaporator blower speed is reduced from the initially set high speed as long as there is only a negligible change in the measured evaporator temperature and therefore a negligible difference in the compressor's power consumption so as to obtain a net increase in the Coefficient of Performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refrigeration system having dual suction port compressor

A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

42 ENGINEERING↗

Cooling system having dual suction port compressor

A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

42 ENGINEERING↗

Control rod drive mechanism with heat pipe cooling

A representative cooling system for a nuclear reactor control rod drive mechanism (CRDM) includes an evaporation section located within or next to the CRDM and a condensation section fluidly coupled to the evaporation section. The cooling system includes a set of heat fins coupled to drive coils in the CRDM and heat pipes that extend through the drive coils and heat fins. A fluid evaporates while in the evaporation section of the heat pipes from heat generated by the CRDM and moves out of the evaporation section into the condensation section in the heat fins. The fluid cools and condensates while in the condensation section, recirculating back into the evaporation section. This passive natural circulation cooling system reduces or eliminates the number of water hoses, piping, and other water pumping equipment typically used for cooling a CRDM thereby increasing nuclear reactor reliability and simplifying nuclear reactor operation and maintenance.

Lobscheid, Christian↗

Simultaneous droplet impingement dynamics and heat transfer on nano-structured surfaces

This study examines the hydrodynamics and temperature characteristics of distilled deionized water droplets impinging on smooth and nano-structured surfaces using high speed (HS) and infrared (IR) imaging at We = 23.6 and Re = 1593, both based on initial drop impingement parameters. Results for a smooth and nano-structured surface for a range of surface temperatures are compared. Droplet impact velocity, transient spreading diameter and dynamic contact angle are measured. The near surface average droplet fluid temperatures are evaluated for conditions of evaporative cooling and boiling. Also included are surface temperature results using a gold layered IR opaque surface on silicon. Four stages of the impingement process are identified: impact, boiling, near constant surface diameter evaporation, and final dry-out. For the boiling conditions there is initial nucleation followed by severe boiling, then near constant diameter evaporation resulting in shrinking of the droplet height. When a critical contact angle is reached during evaporation the droplet rapidly retracts to a smaller diameter reducing the contact area with the surface. This continues as a sequence of retractions until final dry out. The basic trends are the same for all surfaces, but the nano-structured surface has a lower dissipated energy during impact and enhances the heat transfer for evaporative cooling with a 20% shorter time to achieve final dry out. (author)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Seasonal Contrasts in the Surface Energy Balance of the Sahel

Over most of the world ocean, heating of the surface by sunlight is balanced predominately by evaporative cooling. Even over land, moisture for evaporation is available from vegetation or the soil reservoir. However, at the ARM Mobile Facility in Niamey, Niger, soil moisture is so depleted that evaporation makes a significant contribution to the surface energy balance only at the height of the rainy season, when precipitation has replenished the soil reservoir. Using observations at the Mobile Facility from late 2005 to early 2007, we describe how the surface balances radiative forcing. How the surface compensates time-averaged solar heating varies with seasonal changes in atmospheric water vapor, which modulates the greenhouse effect and the ability of the surface to radiate thermal energy directly to space. During the dry season, sunlight is balanced mainly by longwave radiation and the turbulent flux of sensible heat. The ability of longwave radiation to cool the surface drops after the onset of the West African summer monsoon, when moist, oceanic air flows onshore, increasing local column moisture and atmospheric opacity at these wavelengths. After the monsoon onset, but prior to significant rainfall, solar heating is compensated mainly by the sensible heat flux. During the rainy season, the magnitude of evaporation is initially controlled by the supply of moisture from precipitation. However, by the height of the rainy season, sufficient precipitation has accumulated at the surface that evaporation is related to the flux demanded by solar radiation, and radiative forcing of the surface is balanced comparably by the latent, sensible, and longwave fluxes. Radiative forcing of the surface also varies on a subseasonal time scale due to fluctuations in water vapor, clouds, and aerosol concentration. Except at the height of the rainy season, subseasonal forcing is balanced mainly by sensible heating and longwave anomalies. The efficacy of the sensible heat flux depends upon a positive feedback, where forcing changes mixing within the boundary layer and amplifies the sensible heating anomaly. How the surface responds to radiative forcing is fundamental to the climate response to dust and carbonaceous aerosols.

14 SOLAR ENERGY↗

Modeling acid-gas generation from boiling chloride brines

This study investigates the generation of HCl and other acid gases from boiling calcium chloride dominated waters at atmospheric pressure, primarily using numerical modeling. The main focus of this investigation relates to the long-term geologic disposal of nuclear waste at Yucca Mountain, Nevada, where pore waters around waste-emplacement tunnels are expected to undergo boiling and evaporative concentration as a result of the heat released by spent nuclear fuel. Processes that are modeled include boiling of highly concentrated solutions, gas transport, and gas condensation accompanied by the dissociation of acid gases, causing low-pH condensate. Simple calculations are first carried out to evaluate condensate pH as a function of HCl gas fugacity and condensed water fraction for a vapor equilibrated with saturated calcium chloride brine at 50-150 C and 1 bar. The distillation of a calcium-chloride-dominated brine is then simulated with a reactive transport model using a brine composition representative of partially evaporated calcium-rich pore waters at Yucca Mountain. Results show a significant increase in boiling temperature from evaporative concentration, as well as low pH in condensates, particularly for dynamic systems where partial condensation takes place, which result in enrichment of HCl in condensates. These results are in qualitative agreement with experimental data from other studies. The combination of reactive transport with multicomponent brine chemistry to study evaporation, boiling, and the potential for acid gas generation at the proposed Yucca Mountain repository is seen as an improvement relative to previously applied simpler batch evaporation models. This approach allows the evaluation of thermal, hydrological, and chemical (THC) processes in a coupled manner, and modeling of settings much more relevant to actual field conditions than the distillation experiment considered. The actual and modeled distillation experiments do not represent expected conditions in an emplacement drift, but nevertheless illustrate the potential for acid-gas generation at moderate temperatures (<150 C).